Cosel DHS50A, DHS50B, DHS100A, DHS100B, DHS250B Instruction Manual

...
The information contained in this document has been carefully researched and is, to the best of our knowledge, accurate. However, we assume no liability for any product failures or damages, immediate or consequential, resulting from the use of the information provided herein. Our products are not intended for use in systems in which failures of product could result in personal injury. All trademarks mentioned herein are property of their respective owners. All specifications are subject to change without notice.
Instruction Manual
DHS-Series
Cosel
Our company network supports you worldwide with offices in Germany, Austria,
Switzerland, Great Britain and the USA. For more information please contact:
FORTEC Elektronik AG Hauptniederlassung Lechwiesenstr. 9 86899 Landsberg am Lech
Telefon: +49 (0) 8191 91172-0 Telefax: +49 (0) 8191 21770 E-Mail: sales@fortecag.de
Internet: www.fortecag.de
FORTEC Elektronik AG Büro Nord Am Hasenkamp 36 22457 Hamburg
Telefon: +49 (0) 40 54 80 56 11 Telefax: +49 (0) 40 54 80 56 13 E-Mail: nord@fortecag.de
Internet: www.fortecag.de
FORTEC Elektronik AG Büro West Hohenstaufenring 55 50674 Köln
Telefon: +49 (0) 221 272 273-0 Telefax: +49 (0) 221 272 273-10 E-Mail: west@fortecag.de Internet: www.fortecag.de
FORTEC Elektronik AG
Büro Wien Nuschinggasse 12 A-1230 Wien
Telefon: +43 1 8673492-0 Telefax: +43 1 8673492-26 E-Mail: office@fortec.at Internet: www.fortec.at
ALTRAC AG (Tochter der FORTEC): Bahnhofstraße 3 CH-5436 Würenlos
Telefon: +41 (0) 44 7446111 Telefax: +41 (0) 44 7446161 E-Mail: info@altrac.ch Internet: www.altrac.ch
DHS-14
Basic Characteristics Data
*1 Refer to Specification. *2 Refer to Instruction Manual.
Basic Characteristics Data
Model Circuit method
Switching frequency
[kHz]
Input
current
[A]
Rated
input fuse
PCB/Pattern
Series/Parallel
operation availability
Material
Single
sided
Double
sided
Series
operation
Parallel
operation
DHS50A DHS50B
Forward converter 470
*1
- Aluminum Yes Yes
*2
DHS100A DHS100B
Forward converter 470
*1
- Aluminum Yes Yes
*2
DHS200A DHS250B
Forward converter 360
*1
- Aluminum Yes Yes
*2
DHS
1 Pin Connection
DHS-16
2 Connection for Standard Use
DHS-16
6.1 Mounting method
6.2 Stress onto the pins
6.3 Cleaning
6.4 Soldering temperature
6.5 Derating
6.6 Heat sink(Optional parts)
DHS-20
DHS-21
DHS-21
DHS-21
DHS-21
DHS-22
4.1 Overcurrent protection
4.2 Overvoltage protection
4.3 Thermal protection
4.4 Remote ON/OFF
4.5 Remote sensing
4.6 Adjustable voltage range
4.7 Withstanding Voltage / Isolation Voltage
5 Series and Parallel Operation
DHS-20
5.1 Series operation
5.2 Redundancy operation
6 Implementation-Mounting Method
DHS-20
DHS-18
DHS-18
DHS-18
DHS-18
DHS-18
DHS-19
DHS-20
DHS-20
DHS-20
3 Wiring Input/Output Pin
DHS-16
3.1 Wiring input pin
3.2 Wiring output pin
DHS-16
DHS-17
4 Function
DHS-18
7
Lifetime expectancy depends on stress by temperature difference
DHS-23
DC-DC Converters Bus Converter
.
Power Module Type
DHS-15
DHS
Instruction Manual
1 Pin Connection
3.1 Wiring input pin
(1) External fuse
¡
Fuse is not built-in on input side. In order to protect the unit, install
the normal blow type fuse on input side.
¡
When the input voltage from a front end unit is supplied to multiple
units, install the normal blow type fuse in each unit.
2 Connection for
Standard Use
¡
In order to use the power supply, it is necessary to wire as shown
in Fig.2.1 and external components in table2.1.
¡
Short the following pins to turn on the power module.
-VIN
RC, +VOUT +S, and -VOUT -S (DHS200/250)
Reference: 4.4 ”Remote ON/OFF”
4.5 ”Remote sensing”
¡
The DHS Series handles only the DC input.
Avoid applying AC input directly.
It will damage the power supply.
¡
Operate with the conduction cooling(e.g. heat radiation from the
aluminum base plate to the attached heat sink).
Reference: 6.5 ”Derating”
3
Wiring Input/Output Pin
¿
DHS50/100
¿
DHS200/250
Model DHS50A/DHS100A DHS200A
Rated current 3.15A 5A
Model DHS50B/DHS100B DHS250B
Rated current 1.6A 3.15A
No.
Symbol
component Reference 1 F1 Input fuse 3.1 (1) ”External fuse” 2C
Y
Primary decoupling capacitor
3.1 (2) ”Noise fi lter/
Decoupling capacitor”
3 - Noise fi lter 4 Cin
External capacitor on the input side 3.1 (3) ”External capacitor on the input side”
5Co
External capacitor on the output side
3.2 ”Wiring output pin”
6 - Heatsink
6.5 ”Derating”
DC-DC Converters Bus Converter
.
Power Module Type
Instruction Manual
DHS-16
DHS
Table 1.1 Pin Connection and function
Fig.2.1 Connection for Standard Use
Table 3.1 Recommended fuses (Normal-blow type)
Fig.1.1 Pin Connection (bottom view)
2-FG
4 +VOUT
-VOUT6
5 TRM
-VIN
3
RC 2
+VIN 1
4-FG
5
+VOUT
-VOUT8
-S
7
TRM
6
+S
4
-VIN
3
RC 2
+VIN 1
+S, -S : DHS200/250
No.
DHS200/250
DHS50/100
Pin Connection Function
+VIN +DC input RC Remote ON/OFF
-VIN -DC input +VOUT +DC output +S +Remote sensing TRM Adjustment of output voltage
-S -Remote sensing
-VOUT -DC output Mounting hole Mounting hole
1 2 3 4 5 6 7 8
1 2 3 4
5
6
No.
DHS200/250
DHS50/100
Pin Connection Reference
+VIN RC
-VIN +VOUT +S TRM
-S
-VOUT Mounting hole 6.1 "Mounting hole"
1 2 3 4 5 6 7 8
1 2 3 4
5
6
3.1 Wiring input pin
4.4 Remote ON/OFF
3.1 Wiring input pin
3.2 Wiring output pin
4.5 Remote sensing
4.6 Adjustable voltage range
4.5 Remote sensing
3.2 Wiring output pin
+
Heatsink
o
C
Cin
FG
RC
-S
+VOUT
-VOUT
-VIN
+VIN
+S
Y
C
Load
F1
DC
input
Noise
filter
Table 2.1 External components
Loading...
+ 8 hidden pages