In-Building RF Distribution System
Compliant with all existing wireless voice and data services
Supports GPRS, EDGE, CDPD and WAP technologies
Easily upgradable from single band to multi band and future services, 3G ready
Single infrastructure for multiple services/ multiple ope
Built-in alarms / monitors for all channels
Singlemode fiberoptic cables connect between the system units
Easy to design, install and maintain
The Litenna™, fiberoptic based distribution system, enables wireless service operators an d
integrators to provide seamless coverage and enhanced cellular capacity f or In-building applications .
Comprised of a Base Unit that connects up t o eigh t Remo te Hub Unit s (driving up to f our antennas
each), the fiberoptic technology based system is modular and expandable to a wide variety of
structure sizes and configurations. The Litenna supports wireless voice and data applications,
offering a cost-effective and flexible solution for coverage enhancement.
rators

RF Specifications
Downlink
Link Specifications
Nominal Output Power At Antenna
Port Per Carrier per band(dBm)
Composite
2 carriers
3 carriers
10 carrie
Nominal Gain at Antenna Port (dB)
Nominal Input Power
Per Carrier per band (dBm)
Composite
2 carriers
3 carriers
10 carriers
Gain Flatness (dB)
Over Band
Over Block
Max. Second Order Intermodulation
Distortion (IMD) (dBm)
Max. Intermodulation Distortion (IMD)
(dBm)
Waveform Quality ( ) at Max. Power
Spurious Emission (BW=30kHz) (dBc)
System Group Delay (µ s)
800
14
10
9
–
14
0
-3
-5
–
±1.5
±1.2
>45@± 885 KHz
CDMA
1800
14
10
9
–
10
4
1
-1
–
±1.8
–
–
-13
>0.96
<0.1
1900
14
10
9
–
10
4
1
-1
–
±2.0
±1.4
900
11
-1
-6
±1.8
-36
GSM
Dual Band
900/1800
11
-1
-6
-30
1900
17
8
6
1
7
4
1
–
–
–
–
–
14
12
10
-3
±2.0
±1.4
-13
7
7
4
2
±1.8
-36/-30
–
-36/-30
1800
8
6
1
7
4
1
±1.8
–
–
LMR TDMA
800
10
7
–
–
7
3
0
–
–
±1.5
±1.2
–
–
–
20
17
15
10
14
-4
-13
20
17
15
10
14
1900
17
14
12
7
10
6
3
1
-4
7
4
2
-3
±2.0
±1.4
–
-13
–
–
–
800
6
3
1
±1.5
±1.2
–
–
–
–
Uplink
CDMA
Link Specifications
Nominal Gain At Antenna Port (dB)
Min. Input IP3 (dBm)
Max. NF (dB)
Gain Flatness (dB)
Over Band
Over Block
SFDR (dB)
Waveform Quality ( ) at Max. Power
Spurious Emission (BW=30kHz) (dBc)
System Group Delay (µ s)
800
±1.5
±1.2
1800
7
-2
20
20
±1.8
72
>0.96
>45@± 885 KHz
<0.1
7
-2
–
Absolute Maximum Rating
Specifications
Total Input RF Power (dBm)
Power Supply (V)
Operating Temperature (ºC)
Storage Temperature (ºC)
1. For extended temperature range (-20 to 60ºC) contact Foxcom Wireless.
1
Base Unit Remote Hub Unit
20
60
0 to +50
-40 to +85
1900
7
-2
16
±2.0
±1.4
74
900
-2
20
±1.8
GSM
Dual Band
1800
7
±1.8
–
20
65
1900
900/1800
7
-2
–
–
–
–
7
-2
16
±2.0
±1.4
10
60
0 to +50
-40 to +85
20
±1.8
65
LMR
800
7
-2
–
–
–
–
7
-2
20
±1.5
±1.2
72
–
–
–
800
7
-2
20
±1.5
±1.2
72
TDMA
1900
7
-2
16
±2.0
±1.4
74
–
–
–

General Technical Specifications
Optical Specifications
Wavelength (nm)
Max. Optical budget (dB)
Fiber type
Optical loss per mated pair connectors
Optical output power (mW)
Other Specifications
Distance between BU and RHU (m) @18AWG(1)
DC power is supplied via composite cable
DC power is supplied directly to RHU
1. Distance increases with correlation to cable diameter.
1310±10
3dB
9/125 single mode
0.5 dB maximum
≥1.0
500 @ 48VDC / 250 @ 27VDC
2000
Physical Specifications
Specifications Base Unit Remote Hub Unit
Power
Dimensions
RF Connector
Optical Connector
18-48VDC
8W max. when driving 8 RHUs
4W max. when driving 4 RHUs
19” x 1U
N Type Female
SC/APC
18-48VDC - DC input
or: 27-48VDC - fed through composite cable
10 W max. Singleband
15 W max. Dualband
11”W x 8”L x 2”H
N Type Female
SC/APC
Composite Cable Specifications
Specifications
Cable Type
Copper Diameter
Standard Compliance
Single Mode Fiber 2.8 mm Tight Buffer Jacket
18AWG
UL Listed Cable / IEC -332-33
Alarm Specifications
Base Unit Alarms
The Litenna™ Base Unit alarms are Dry Contacts and Open Collector types. The Dry Contacts opens when the alarm is active. The Open Collector will sink up to 30mA
under alarm condition. All alarms are connected to the Base Unit rear panel 25 pin D type connectors.
Alarm
Optical Link
Function
Indicates that the two direction optical link between Base Unit and Remote Hub Unit are not functioning
LED Specifications
Base Unit LEDs
The Base Unit has three types of LEDs. One type indicates the power status. One type indicates that the lasers are functioning. One type indicates the status of link
operations between the Base Unit and the RHU-one LED for every RHU. All LEDs should be on when the unit is in operation.
LED Name
Channel 1..8
Lasers 1..4
Lasers 5..8
DC
LED Function
Indicates that both directions of the optical link, between Base Unit and Remote Hub Unit,
is functioning - one LED for every RHU link.
Indicates that laser circuitry for RHU 1-4 is functioning correctly.
Indicates that laser circuitry for RHU 5-8 is functioning correctly.
Indicates that the power is on.
Remote Hub Unit LEDs
On the Front Panel of the RHU ther e ar e two LEDs . Both LEDs should be on when the unit is in oper ation.
LED Name LED Function
Opt.
DC
Indicates that the Received Optical Power is functioning within specifications.
Indicates that the power is on.

©Sadna 5/2000
Litenna™ Block Diagram
Litenna™ Base Unit
Down Link
RF In
(Sector 1)
RF In
(Sector 2 Opt.)
Up Link
RF Out
(Sector 1)
RF Out
(Sector 2 Opt.)
Mechanical Dimensions
19”
Fiberoptic
Tx #1
Fiberoptic
Tx #8
Fiberoptic
Rx #1
Fiberoptic
Rx #8
Base Unit
Base Unit Front Panel
Optical In/Out
12”
Base Unit Back Panel
RF In
Litenna™ RHU #1
Fiberoptic
Rx #1
Fiberoptic
Tx #1
RF
RF
Filters & Diplexers
HPA
LNA
Litenna™ RHU #8
Fiberoptic
Rx #8
Fiberoptic
Tx #8
RF
RF
Filters & Diplexers
HPA
LNA
Remote Hub Unit
11”
1U
RF OutAlarm
Remote Hub Unit Front Panel
Optical Out
8”
Cellular Antennas
Optical In
2”
Foxcom Wireless Ltd.
Ofek One Center - Building B
Northern Industrial Zone
Lod, Israel 71293
Tel: +972-8-918-3888
Fax: +972-8-918-3844
E-mail: sales@foxcomwireless.com
Foxcom Wireless Inc.
8150 Leesburg Pike
Suite 600
Vienna, Virginia 22182
Tel: 703-848-0200
Fax: 703-848-0280
E-mail: salesna@foxcom wireless.com
Website: www.foxcomwireless.com
Supported Standards
STANDARDS
CDMA 800
TDMA/AMPS 800
LMR 800
GSM 900
CDMA 1800
GSM 1800
CDMA 1900
TDMA 1900
GSM 1900
For Indoor use only.
All specifications are subject to change without prior notice.
UL/DL (MHz)
824-849 / 869-894
806-824 / 851-869
890-915 / 935-960
1715-1780 / 1805-1870
1710-1785 / 1805-1880
1850-1910 / 1930-1990
Ordering Information
Product
Single Band Family
9A110 = AMPS/TDMA 800
9A112= LMR 800
9A130 = CDMA 800
9A220 = GSM 900
9A320 = GSM 1800
9A330 = CDMA 1800
9A410 = TDMA 1900
9A420 = GSM 1900
9A430 = CDMA 1900
Dual Band Family
9B320 = Dual band GSM 900/1800
Available Accessories
SC/APC Jumper
Local Power Supply
Fully Redundant Power Supply
Fully Redundant Power Supply
9XXXX - XXX - XX
Part
RHU = Remote Hub Unit
B4U = Base Unit Four Ports
B8U = Base Unit Eight Ports
5m
25W
110/220V
100W
110/220V
300W
110/220V
Reserved
Order Code
SC/APC-J-5
LPS-25-48
LPS2-100-48
LPS2-300-48
© Foxcom Wireless 2000. Doc. No. 42-13-002-20-A