Corning Optical Communications Wireless, Inc. (“Corning”) warrants to the original purchaser (“Customer”) that for the
duration of the warranty period, one (1) year, commencing on the date of shipment of the Hardware, unless other wise agree d
in writing by Corning (the “Hardware Warranty Period”), the Hardware furnished by Corning shall be free in all material
respects from defects in material and workmanship, and shall conform to the applicable portions of the Specifications, as
defined below (the “Hardware Warranty”).
If notified by Customer of any such defects in material or workmanship or nonconformity with applicable portions of the
Specifications within the Hardware Warranty Period, Corning shall promptly, at its own election and expense, r epair or
replace any such Hardware proven to be defective under the terms of this Hardware Warranty.
Such repair or replacement shall be Customer’s sole remedy and Corning’s’ sole obligation in the event this Hardware
Warranty is invoked. If any components comprising a part of the Hardware are replaced or repaired during the Hardware
Warranty Period, the Hardware Warranty Period for such repaired or replaced components shall extend to the longer of (i) the
balance of the Hardware Warranty Period or (ii) three (3) months from the date of repair or replacement. For purposes of this
Warranty, “Specifications” shall mean the specifications and performance standards of the Products as set forth in documents
published by Corning and delivered to Customer which contain technical specifications or performance standards for the
Products.
If Customer invokes this Hardware Warranty, it shall notify Corning promptly of the claimed defect. Customer will allow
Corning to inspect the Hardware at Customer’s location, or to return the Hardware to Corning’ closest repair facility. For
Hardware returned to Corning’s’ repair facility, Customer shall be responsible for payment of all transportation and freight
costs (including insurance) to Corning’s’ repair facility, and Corning shall be responsible for all transportation and freight costs
(including insurance) incurred in connection with the shipment of such Hardware to other repair facilities of Corning and/or its
return to Customer.
Notwithstanding the foregoing, in no event will Corning be liable for damage to Products resulting from improper handling
during or after shipment, misuse, neglect, improper installation, operation or repair (other than by authorized C ornin g
personnel), alteration, accident, or for any other cause not attributable to defects in materials or workmanship on the part of
Corning. Corning shall not reimburse or make any allowance to Customer for any labor charges incurred by Custom er for
replacement or repair of any goods unless such charges are authorized in advance in writing by Corning.
Software Warranty
Corning warrants to the original purchaser (“Customer”) that for the duration of the warranty period, one (1) year,
commencing on the date of shipment of the Software, unless otherwise agreed in writing by Corning
(the “Software Warranty Period”), the Software shall conform with, and perform the functions set forth in the Specificat io ns ,
and shall be free from defects in material or workmanship (the “Software Warranty”). In the event the Software is proven to be
defective under the terms of this Software Warranty, Corning shall correct such defects or failure and ensure that the
Software conforms with, and performs the functions set forth in, the Specifications. Customer will allow Corning to inspect the
Software at Customer’s location or to return it to Corning’s closest repair facility. Notwithstanding the foregoing, Corning shall
have no obligation under the Software Warranty if the Software is modified or used with hardware or software not supplied or
approved by Corning or if the Software is subject to abuse, improper installation or application, accident, electrical or
environmental over-stress, negligence in use, storage, transportation or handling. Third-party software distributed with the
Software may carry certain warranties which, to the maximum extent allowed by law, Corning hereby assigns, transfers and
otherwise conveys to Customer, provided, however, that Corning itself provides no warranty of any kind, express, implied,
statutory or otherwise, for any third-party software provided hereunder.
Corning Restricted - Draft for public release
CMA-xxx-AEN Page 2
Warranties
DRAFT
Corning does not warrant any hardware, software or services not provided by Corning.
THIS WARRANTY IS THE ONLY WARRANTY MADE BY CORNING AND IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. CORNING S SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE
INCLUDING, BUT NOT LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR
IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND SERVICE HEREUNDER, OR THE PERFORMANCE,
USE OF, OR INABILITY TO USE THE GOODS, PARTS AND SERVICE. CORNING SALES AGENTS OR
REPRESENTATIVES ARE NOT AUTHORIZED TO MAKE COMMITMENTS ON WARRANTY RETURNS.
Returns
In the event that it is necessary to return any product against above warranty, the following procedure shall be followed:
1. Return authorization is to b e r ec eived f r om Corning prior to r eturning any unit. Advise Corning of the model , Seri al n umber,
and discrepancy. The unit may then be forwarded to Corning, transportation prepaid. Devices returned collect or without
authorization may not be accepted.
2. Prior to repair, Corning will advise the customer of our test results and any charges for repairing customer-caused
problems or out-of-warranty conditions etc.
3. Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment.
Limitations of Liabiliti es
Corning’s liability on any claim, of any kind, including negligence for any loss or damage arising f rom , conne c ted with, or
resulting from the purchase order, contract, quotation, or from the performance or breach thereof, or from the design,
manufacture, sale, delivery, installation, inspection, operation or use of any equipment covered by or furnished under this
contact, shall in no case exceed the purchase price of the device which gives rise to the claim.
Except as expressly provided herein, Corning makes no warranty, expressed or implied, with respec t to an y goods, parts and
services provided in connection with this agreement including, but not limited to, the implied warranties of merchantability and
fitness for a particular purpose. Corning shall not be liable for any other damage including, but not limited to, indirect, special
or consequential damages arising out of or in connection with furnishing of goods, parts and service hereunder, or the
performance, use of, or inability to use the goods, parts and service.
Reporting Defects
The units were inspected before shipment and found to be free of mechanical and electrical defects. Examine the units for
any damage that may have been caused in transit. If damage is discovered, file a claim with the freight carrier immediately.
Notify Corning as soon as possible in writing.
Note: Keep all packing material until you have completed the inspection
Corning Restricted - Draft for public release
Warranties
CMA-xxx-AEN Page 3
DRAFT
Warnings and Admonishments
There may be situations, particularly for workplace environments near high-powered RF sources, where recommended limits
for safe exposure of human beings to RF energy could be exceeded. In such cases, restrictive measures or actions may be
necessary to ensure the safe use of RF energy.
The equipment has been designed and constructed to prevent, as far as reasonably, practicable danger. Any work activity on
or near equipment involving installation, operation or maintenance must be, as far as reasonably, free from danger.
Where there is a risk of damage to electrical systems involv ing adver se w eath er, ex tr eme temperatures, wet, corrosive or
dirty conditions, flammable or explosive atmospheres, the system must be suitably installed to prevent danger.
Equipment provided for the purpose of protecting individuals from electrical risk must be suitable for the purpose and properly
maintained and used. This covers a range of activities inclu ding lif tin g, lowering, pushing, pulling, carrying, moving, holding or
restraining an object, animal or person from the equipment. It also covers activities that require the use of force or effort, such
as pulling a lever, or operating power tools.
Where some of the abovementioned activities are required, the equipment must be handled with care to avoid being
damaged.
Observe standard precautions for handling ESD-sensitive devices. Assume that all solid-state electronic devices are ESDsensitive. Ensure the use of a grounded wrist strap or equivalent while work ing with ESD-sensitive devices. Transport, store,
and handle ESD-sensitive devices in static-safe environments.
RF Safety
WARNING! To comply with FCC RF exposure compliance requirements, each individual antenna used for this transmitter
must be installed to provide a separation distance greater than 115 cm or more from all persons during normal operation and
must not be co-located with any other antenna for meeting RF exposure requirements.
WARNING! Antenna gain should not exceed 15 dBi.
WARNING! Each individual antenna used for this transmitter must be installed to provide a separation distance greater than
115 cm or more from all persons and must not be co-located with any other antenna for meeting RF exposure requirements.
WARNING! The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation
safety levels and non-environmental pollution during operation.
Compliance with RF safety requirements:
• Corning products have no inherent significant RF radiation.
• The RF level on the downlink is very low at the downlink ports. Therefore, there is no dangerous RF radiation when the
antenna is not connected.
Power requirements for DC Inputs
WARNING! Only use a special DC supply cable with connector
WARNING! Always keep DC IN connectors connected during the product operation
WARNING! Disconnect all power from the equipment by means of an external circuit breaker before connecting or
disconnecting the DC IN connectors.
Corning Restricted - Draft for public release
Warnings and Admonishments
CMA-xxx-AEN Page 4
DRAFT
Laser Safety
Fiber optic ports of the HX system emit invisible laser radiation at the 1310/1550 nm wavelength window.
The laser apertures /outputs are the green SC/APC Bulkhead adapters located on the front panel of the equipment.
The product is Class 1/Hazard level 1
External optical power is less than 10 mW, Internal optical power is less than 500 mW.
To avoid eye injury never look directly into the optical ports, patchcords or optical cables. Do not stare into beam or view
directly with optical instruments. Always assume that optical outputs are on.
Only technicians familiar with fiber optic safety practices and procedures should perform optical fiber connections and
disconnections of HX devices and the associated cables.
HX has been tested and certified as a Class 1 Laser product to IEC 60825-1. It also meets the requirements for a Hazard
Level 1 laser product to IEC 60825-2 +a2(2010) to the same degree.
Care of Fiber Optic Connectors
Do not remove the protective covers on the fiber optic connectors until a connection is ready to be made. Do not leave
connectors uncovered when not connected.
The tip of the fiber optic connector should not come into contact with any object or dust.
Regulatory Compliance Information
WARNINGS!
•This is NOT a CONSUMER device. It is designed for installation by FCC LICENCEES and QUALIFIED INSTALLERS.
You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this device. Unauthorized use
may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation.
•ANTENNAS: Use only authorized and approved antennas, cables and/or coupling devices! The use of unapproved
antennas, cables or coupling devices could cause damage and may be of violation of FCC regulations.
•It is prohibited to use unauthorized antennas, cables and/or coupling devices and the use of these devices, which is
illegal under FCC regulations, may subject the user to fines.
•Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor-only
restrictions and the system shall not be used for outdoor.
Corning Restricted - Draft for public release
Laser Safety
CMA-xxx-AEN Page 5
DRAFT
Standards and Certifications
Corning products have met the approvals of the following certifying organizations:
Category Standards
Safety
Laser Safety
Radio FCC CFR47 Part 27
EMC FCC CFR47 Part 15
RoHs RoHs 6 compliant
UL 60950-1
IEC 60825-1: 2007
Licensee Contact Information
Industrial Boosters may only be used by FCC licensees or those given express (individualized) consent of license. Corning
certifies all of the VARs listed as licensed installers for Corning. For the list of licensed VARs, please contact the Corning
Tech Support Hotline: (US) 410-553-2086 or 800-787-1266.
About this Guide
This Installation Guide describes how to perform the physical installation of the HX unit. The installation procedures of other
units (e.g. RIU, OCH, SC-450) relevant to the system are detailed in their user manuals (see Additional Relevant
Documentation below).
Additional Relevant Documents
The following documents are required if the corresponding units are included in your system.
Document Name
RIU Installation and Configurat ion Gu ide
FT-350 User Manual (includes OCH information)
System Controller (SC-450) v7.3 User Manual
MA Software Version Update Tool
Corning Restricted - Draft for public release
Standards and Certifications
CMA-xxx-AEN Page 6
DRAFT
List of Acronyms
BTS
BTSC
DL
EPM
HX
MUX
OCH
PA
PSU
RCU
RIU
RU
SC-450
UL
Base Transceiver Station
Base Transceiver Station Conditioner
Downlink
Expansion Passive Module
High Power Remote
Multiplexer
Optical Central Hub
Power Amplif ier
Power Supply Unit
Remote Control Unit
Radio Interface Unit
Remote Unit (module)
System Controller
Uplink
Limitations of Liabilities ................................................................................................................................. 3
1.1 Key Features and Capabilities ............................................................................................................ 12
1.2 System Architecture ............................................................................................................................ 13
1.3 System Monitoring and Managem ent ................................................................................................. 15
1.4 HX Unit Description ............................................................................................................................. 16
2.1 Site Considerations ............................................................................................................................. 22
Standards and Approvals ............................................................................................................................ 57
Corning Restricted - Draft for public release
Table of Contents
CMA-xxx-AEN
Page 10
Appendix B: Ordering Information ........................................................................................ 58
HX 2.5 GHz TDD is a m id-po wer, rem ote s olution des igned t o be in tegrat ed into exis ting M obileAc cess 1000 (MA1 000)
and MobileAccess2000 (M A2000) Distributed Antenna S ystems (DAS) already deployed in the f ield. It is a fiber fed,
compact and scalable multi-service platform designed to complement the MA1000/MA2000 and other HX4 and HX
WCS remotes while prov iding complete RF open space coverage f or large-scale public venues such as cam puses,
stadiums, convention centers, hotels, airports and train stations.
Using low-loss fiber opt ic c abling, r em ote units can c over d istances of up to 1.4 mi (2 km ) f rom the BT S sig nal sour ces
at the headend. HX 2.5 G Hz TDD requires minim um addition of hardware to the headend (BT SC 2500) and utili zes
existing fiber and antenn a overlay. It also includ es test ports, enabling to measure the s ignals at the remote without
disconnecting the antenna cable and affecting services on the main stream. HX 2.5 GHz TDD MIMO takes full
advantage of MIMO technology by using spatial multiplexing to deliver higher s pectral efficiency and preventi ng the
degradation of quality while significantly increasing throughput on the same spectrum.
HX 2.5 GHz TDD
Figure 1-1
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 12
1.1 Key Features and Capabilities
• Service Platform: Accommodates LTE TDD and provides SISO/MIMO configuration for the 2.5 GHz TDDband
• Cost-Effective High Power: Optimizes and reduces the number of antennas required to cover open areas by
offering up to 33 dBm (2 W) composite power per frequency band.
• Scalability: Supports either SISO or MIMO service in a single compact enclosure.
• Operator-Grade Operation: Advanced signal handling and management ensures operator-grade performance in
multi-operator deployments.
•Design and Deployment Flexibility: Antenna splitting schemes are possible due to the higher power output
capability.
•Compatibility: Connects to existing MobileAccess1000, MobileAccess2000 and additional HX4 and HX W CS
remote units to allow common antenna overlay; Shares a common headend and EMS in a single deplo yment)
•Monitoring and Web Management: All status LEDs are located on front panel; Web management via the SC-450
controller (v7.3 and higher)
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 13
1.2 System Architecture
Figure 1-2 shows an example of SISO scenarios in a system topology where the HX 2.5 GHz TDD is connected to
existing HX4 and M A2 000 Q X rem otes . The HX 2.5 GHz TD D remote is installed bet ween the ex isting remote unit ( e.g.
HX, MA2000 QX) and the optical converter unit (i.e. OCH) and interfaces them both via fiber connections.
In the downlink, at th e headend, the BTS or BDA si gnal is condit ioned by the RIU, ensuring a cons tant RF level. T he
conditioned signal is then converted by the optical central hub (OCH) to an optical signal for transport over single mode
fiber to the HX, located at the remote location. In the uplink, the process is reversed.
The system controller (SC-450 v7.3) enables local an d rem ote m anagem ent, as wel l as co ntrols all MA1000 , M A2000,
and HX elements from a single, centralized location.
HX 2.5 GHz TDD – SISO Architecture with an existing HX4 and MA2000 QX, Sharing a Common
Headend
Figure 1-2
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 14
Figure 1-4 shows an example of MIMO scenarios in a system topology where the HX 2.5 GHz TDD is connected to
existing HX4 and M A2 000 Q X rem otes . The HX 2.5 GHz TD D remote is installed bet ween the ex isting remote unit ( e.g.
HX, MA2000 QX) and the optical converter unit (i.e. OCH) and interfaces them both via fiber connections. MIMO
configurations require one line of fiber for each MIMO stream and one EPM for each stream in installations with
MA1000/MA2000 remotes.
HX 2.5 GHz TDD – MIMO Architecture with an existing HX4 and MA2000 QX, Sharing a Common
Headend
Figure 1-3
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 15
1.3 System Monitoring and Management
The HX 2.5 GHz TDD rem ote unit is centrally m anaged via the SC-450 controller (v7.3 and high er). Note that HX is
not directly connected to the control ler but managed and configur ed via the OCH to which it is connected. Figure
shows the main configuration window for the selected HX 2.5 GHz TDD unit.
Note: Refer to t he SC-450 controller user manual (v7.3 and higher) for information on how to co nfigure and manage
the HX 2.5 GHz TDD remote unit.
1-4
Example of HX 2.5GHz TDD Configuration Tab
Figure 1-4
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 16
1.4 HX Unit Description
The HX 2.5GHz TDD unit consists of the following main modules:
• RCU – Remote control unit; Includes status LEDs for each module and control ports
• ANT (MUX) – Multiplexer [ANT. 1 MUX (right) for SISO; ANT. 2 MUX (left) for MIMO] including interfaces to HX
WCS, HX4 and RF antenn as /MA 100 0/M A20 00 un its (via EPM); combines signa l sour c es additional external RF
signals (when connected to HX unit and MA1000/MA2000 remote) while providing the proper filtering into a single
antenna port
•Module – [ANT. 1 (right) for SISO; ANT. 2 (left) for MIMO] Internal module that interfaces to the optical converter
unit (OCH) connects via a single mode fiber pair and supports one service. The HX 2.5 GHz TDD module provides
the additional amplification on the DL signals routed from the OCH towards the multiplexer.
•Power Supply - DC powe r; Internal module
The unit plot plan is provided on the left side of the enclosure door:
HX 2.5 GHz TDD Unit Plot Plan
Figure 1-5
The following sections provide details on the front panel and internal module interfaces.
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 17
1.4.1 HX 2.5 GHz TDD External Interfaces
Connector
Description
ANT.
Mini DIN 4.3-10 type duplexed antenna port (one per multiplexer)
CPL.
SMA-Type female 50Ω coupling port (-40 dB ± 1.0 dB) used for RF DL test (one per
multiplexer)
WB RU
N-Type duplexed wideband remote unit expansion port for interfacing to HX4
those of the HX 2.5 GHz TDD and distributed from its antenna port
WCS RU
Mini DIN 4.3-10 Type duplexed port (one per multiplexer) for interfacing to HX WCS
TDD and distributed from its antenna port
Ext. 1 / Ext. 2
N/A (Future option)
GND
Two-hole, standard barrel grounding lug
Ext. Alarms
DB-9 female external alarm connector for external dry contact alarm connections;
Supports up to four external alarms (configurable via the Web GUI)
RS-232
D-Type 9 pin female console port used for connecting to engineering GUI
T-Sync
SMA type connector for TDD sync monitoring
Ethernet
Ethernet connection for local craft
The HX 2.5 GHz TDD front panel includes the multiplexer interfaces (e. g. antenna port, DL Tes t port, wideband RU
port), system level status LEDs and service maintenance ports.
Note: Both SISO and MIMO models include two sets of multiplexer RF interfaces. For SISO models, the RF
connections will be performed via the connectors corresponding to the installed HX remote unit module (inside chassis):
Left MUX for Left HX 2.5 G Hz Module and Right MUX for Right HX 2.5 G Hz Module. See section
modules.
1.4.2 for internal
HX 2.5 GHz TDD Front Panel Interfaces
Figure 1-6
Table 1-1 provides a description of the front panel connectors.
remote (one per multiplexer) so that additional HX4 services are combined with
RF input so that additional WCS service is combined with those of the HX 2.5 GHz
Table 1-1. HX 2.5 GHz TDD Front Panel Connectors
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 18
Refer to Figure 1-7 and Table 1-2 for description of HX status LEDs.
Service
Green
Service status is ok
Red
Any service alarm is se t
Ant.
Green
VSWR alarm is clear
Red
VSWR alarm is set
Temp.
Green
Over Temp and Temperature Protection alarms are clear
Red
Over Temp or Temperature Protection alarms is set
T-Sync
Green
TDD sync locked
Red
TDD sync error (unlocked)
Fan
Green
Fan alarm is clear
Yellow
Fan alarm is set (minor) for first fan faulty
Red
Fan alarm is set (minor or major) for more than one faulty fan
HX 2.5GHz TDD RCU Module Status LEDs
Figure 1-7
Note: Module 1 and Module 2 LEDs correspond to installed modules [Module 1 for ANT. 1 (SISO); Module 2 for ANT. 2
(MIMO)].
LED State Description
Run Steady green
Off
Power input detected
Unit power is off
Comm Green Short blink upon receiving FSK message(Off at any other time)
Link Steady green Optical link level is above normal threshold
Blinking green Optical link level is lower than normal threshold but above no-link
threshold
Off Optical link level is below No link threshold
Status Green / Yellow / Red Color according to device’s overall status
Table 1-2. HX 2.5GHz TDD RCU Status LED Descriptions
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 19
1.4.2 Internal Module Interfaces
The HX internal modules include two main modules (see Figure 1-8):
• PSU – Power supply module; includes DC In connector and status LEDs
• HX Module – one for SISO cabinets and two for MIMO (the interfaces are the same for each module); comprises
an optical module and power amplifier; interfaces to the base unit; Left HX Module 2 (MIMO) corresponds to left
HX MUX and right HX Module 1 (SISO) corresponds to right MUX.
HX (MIMO) Internal Modules – PSU (Left) and HX 2.5 GHz TDD Modules (Middle and Right)
Figure 1-8
Module Interface Description
PSU Power connector 34-48 V DC input; 8 pin DC terminal block connector
(Dinkle 2EHDRM-08P)
HX Module Optic Port SC APC fiber-optic pair connector; SM fiber; connection
towards OCH
Extension UL/DL SMA Type connector N/A (future option)
Table 1-3. HX 2.5 GHz TDD PSU and Module Connectors
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 20
Module LED Description
band input port interfaces to
ombined output ports interface to
PSU Run Steady green – required power input detected
Off – no power input
PSU Off – normal operation
Steady red – faulty PSU module; In more than 10%
difference than the rated DC output, the red LED occurs.
HX-2.5 GHz
TDD Module
Link Off – No optical link
Blinking green – Low optical link level
Steady green – Normal optical link level
Run Off – no power input
Blinking green – power input detected
Table 1-4. HX 2.5 GHz TDD PSU and Module LEDs
1.5 External Passive Module (EPM)
The external passive module (EPM) is r equ ired when in installations with an existing MA1000/MA20 00 remote unit (e.g.
MA2000 QX). T he EPM is used to com bine up to four low band outp ut wideband signals wit h the high band HX 2.5
GHz TDD output signal. The module includes a 1:4 splitter for the high band (i.e. 2.5 GHz T DD) and four internal
diplexers that combine the 2.5 GHz TDD signal with the wideband signal received from the MA1000/MA2000 remote.
The EPM interfaces to the HX 2.5 GHz TDD and to the service combiner unit (SCU) of the MA1000/MA2000 remote.
External Passive Module – Front (Top) and Rear (Bottom) Panels
Figure 1-9
Refer to Table 1-5 for a description of the EPM interfaces.
Panel Connector Description
Front HIGH I/O One Mini DIN 4.3-10 high-
additional HX or MA1000/MA2000 remote
Rear ANT Four Mini DIN 4.3-10 c
wideband antennas
LB Four N-Type low-band input ports interface to service combiner
unit (SCU) on MA1000/MA2000
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 21
Table 1-5. EPM Front and Rear Panel Interfaces
Corning Restricted - Draft for public release
Installation Guidelines
CMA-XXX-AEN
Page 22
2 Installation Guidelines
This provides guidelines for installing the HX 2.5 GHz TDD remote unit.
2.1 Site Considerations
•The distance between the HX service antenna and the coverage area should correspond to LOS (Line of Sight)
requirements for maximum coverage area.
• The maximum fiber path loss is 3 dB.
• The system delay of the optical system must be taken into consideration when there are neighboring BTS sites
overlapping in coverage.
2.2 Environmental
Humidity has an adverse effect on the reliability of the equipment. It is recommended to install the equipment in
locations having stable temperature and unrestricted air-flow.
The installation location f or the system should be well ventilated. The equipm ent has been designed t o operate at the
temperature range and hu midity level as stat ed in the produc t specifications with a relative hum idity of max. 90% and
temperatures range of -20° to +60°C (-4° to 140°F).
2.3 Installation Requirements
• Mounting surface shall be capable of supporting the weight of the equipment.
• In order to avoid electromagnetic interference, a proper mounting location must be selected to minimize
interference from electromagnetic sources such as large electrical equipment.
•Working space available for installation and maintenance for each mounting arrangement. Ensure unrestricted
airflow.
• Ensure grounding connector is within reach of the ground wire.
• Ensure a power source is within reach of the power cord and the power source has sufficient capacity.
• Where appropriate, ensure unused RF connectors are terminated.
• Do not locate the equipment near large transformers or motors that may cause electromagnetic interference.
• Reduce signal loss in feeder cable by minimizing the length and number of RF connections.
• Ensure the equipment will be operated within the stated environment (refer to datasheet).
• Where appropriate, confirm available of suitably terminated grade of RF and optical fiber.
• Observe handling of all cables to prevent damage.
Corning Restricted - Draft for public release
Installation Guidelines
CMA-XXX-AEN
Page 23
2.4 Fiber Optic Requirements
2.4.1 Authorized Optic Cables
• Only single mode fiber can be used with HX 2.5 GHz TDD product
• All fiber in a given length of fiber must be of the same core diameter.
• All bulkhead adapters must be single mode SC APC (green) adapters.
• All terminations, cross connections or patches must be direct fusion splice or Corning specified patch cords listed
below.
900 microns pathcord for splicing, 2 Meters, 2xSC/APC
Diamond p/n ENC/1045344 Beige/Brown boots, 1 Meter MA# 500001061
Diamond p/n ENC/1045345 Beige/Brown boots, 3 Meter MA# 500001062
2.4.2 Fiber Optic Rules
ATTENTION!
Please also refer to the laser safety section in the document preface.
•Fiber optic cables require proper handling. Do not stretch, puncture, or crush the fiber cable(s) with staples, heavy
equipment, doors, etc.
•Always maintain the minimum bending radius specified by the cable manufacturer. The minimum bend radius is
usually 10 times the cable's outer diameter. In the case of single optical fiber that is not in a cable, the minimum
bending radius to be observed is 30 mm.
• Use SC APC connectors (green color) 8 deg only.
• Pay special attention w hile c onnec ti ng the SC APC connectors - ensure that you hear a “click”, indicating a secure
connection
• Use minimum splicing/connectors to achieve minimum losses on the fibers.
• Use precaution while installing, bending, or connecting fiber optic cables.
• Use an optical power meter and OTDR for checking the fiber optic cables.
• Make sure the environment is clean while connecting/splicing fiber optic cables.
• All fiber optic connectors should be cleaned prior to connecting to the system
• Fiber connector protective caps should be installed on all non-terminated fibers and removed just before they are
terminated.
•Check the fiber optic connections.
Corning Restricted - Draft for public release
Installation Guidelines
CMA-XXX-AEN
Page 24
•Never look directly into the end of a fiber that may be carrying laser light. Laser light can be invisible and can
damage your eyes.
2.5 RF Coaxial Cable Guidelines
2.5.1 General Cable Installat ion Procedures
Note: The installer should be familiar with the ANSI/TIA/EIS-568 Cabling Standard guidelin es .
Observe the general cable installation procedures that m eet with the building codes in your ar ea. The building code
requires that all cablin g be installed ab ove ceiling le vel (where appl icable). The l ength of c able from the ris ers to each
antenna may need to be concealed above the ceiling.
The cable must be properly supported and maintained straight using velcro cable ties, cable trays and clamps or
hangers every 10 feet (where practical above ceiling level). Where this is not practical, the following should be
observed:
• The minimum bending radius of the supplied ½-in coax cable should be 7-in.
• Cable that is kinked or has a bending radius smaller than 7-in must be replaced.
• Cable runs that span less than two floors should be secured to suitably located mechanical structures.
• The cables should be supported only from the building structure.
• All cables shall be weather-resistant type
• Cable length - determined by the system installation plan. When calculating the cable length, take into account
excess cable slack so as not to limit the insertion paths.
.
2.5.2 RF Rules
• Use coax RG-223, 50 ohm, for RF connections between HX units and DAS antennas.
• When using the Corning system in an environment in which other indoor coverage systems are installed, it is
recommended (where possible) that the antennas are placed at least two meters apart
• When bending coax cables, verify that the bending radius does not exceed the coax specifications.
• Use wideband antennas supporting a range of 700 MHz to 2600 MHz
• Terminate all unused HX RF ports with a 50 ohm load
• Make sure that the VSWR measured at the coax cable meets the product specification The VSWR must be
measured prior to terminating the HX RF ports in the remote communication rooms.
2.5.3 Coax Cable Lengths and Losses
Use the compatible jumper to connect the coax connector to the external antenna.
Note: The required distance between the antennas (installed in the ceiling) depends on the infrastructure and
calculated path-loss.
Ensure all cables, e.g. p ower cable, feed er c able, opt ic f iber, comm issionin g cab le, connec ting are prop erl y routed and
secured so that they are not damaged.
2.6 Antenna Specifications and Guidelines
Determine the antenna installation configuration, according to the transmission and coverage requirem ents and the
installation site conditions.
2.6.1 Authorized Antennas and Couplers
• External antennas - No limitation on any vendor of available external antennas with respect to the following
requirements:
• Omni Directional or Directional
• Supported frequency range: wideband antennas supporting a range of 700 MHz to 2600 MHz
• Gain: up to 12.5 dBi
• Impedance: 50 Ohm
• Types of couplers/splitters – depends on number of splits
Corning Restricted - Draft for public release
Installation Guidelines
CMA-XXX-AEN
Page 26
•Couplers – Use N-Male to N-Female broadband coupler separately ordered from Corning (P/N AK-1COUPLER-
NM-NF) or the equivalent:
• Broadband frequency: 698 – 2700 MHz
• -40 dB coupling (QMA coupling port)
• Max. VSWR/Return Loss: 5:1 / 16 dB
• Max. Insertion Loss (dB): 0.2
• Impedance: 50 ohms
2.6.2 General Antenna Installation Guidelines
• The wideband antenna should be installed at a convenient location, free of metallic obstruction (can also be
installed in plenum spaces).
• Install the connected antenna at the designated height and tune it roughly toward the Service coverage area.
• Each individual antenna used for this transmitter must be installed to provide the separation distance as specified in
the FCC grant from all persons during normal operation and must not be co-located with any other antenna for
meeting RF exposure requirements
2.7 Grounding Requirement
Verify that the equi pment has bee n well ground ed (refer to t he grounding lug on the bott om r ight corner of th e HX 2.5
GHz T DD front panel). T his includes antennas and all cabl es connected to the s ystem. Ensure lightning pr otection for
the antennas is properly grounded. Also, see section
3.3.3.
2.8 Manual Handling
During transportation and installation, take necessary handling precautions to avoid potential physical injury to the
installation personnel and the equipment.
2.9 Installation Requi rem ents
•Working space available for installation and maintenance for each mounting arrangement. Ensure unrestricted
airflow.
• Ensure grounding connector is within reach of the ground wire.
• Ensure a power source is within reach of the power cord and the power source has sufficient capacity.
• Where appropriate, ensure unused RF connectors are terminated.
• Do not locate the equipment near large transformers or motors that may cause electromagnetic interference.
• Reduce signal loss in feeder cable by minimizing the length and number of RF connections.
• Ensure the equipment will be operated within the stated environment (Appendix A: System Specifications).
• Where appropriate, confirm available of suitably terminated grade of RF and optical fiber.
• Observe handling of all cables to prevent damage.
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 27
3 Physical Installation
HX 2.5 GHz TDD remote unit:
1
This chapter describes the mounting procedure and physical connections for the HX 2.5 GHz TDD remote unit.
3.1 Unpacking and Inspection
Unpack and inspect the cartons according to the following procedure
1. Open the shipping carton and carefully unpack each unit from the protective packing material.
2. Verify that all of the item required for installing the HX 2.5GHz TDD have been received (refer to Table
any of the listed items are missing, contact your Corning representative.
3. Check for signs of external damage. If there is any damage, c all your Corning service representative.
HX Kit Item Quantity
• HX-2500-SISO*
HX-2500-MIMO**
*SISO models include one HX-2.5 GHz TDD
Module (internal) and one slot cover (blank panel
for unoccupied HX-2.5 GHz TDD Module MIMO
slot)
Wall Mount Bracket (Belly-to-Wall) Assembly:
Bracket
Pan Head Screw Sems UNC 6-32, 12 mm;
Stainless Steel; Used for securing bracket to HX
sides
Table 3-1. HX 2.5 GHz TDD Package Items List
2
(RT/LT)
20
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 28
3.2 Mounting
The HX 2.5 GHz TDD unit is installed in the communication room via one of the following options (each type of
installation requires a different pair of brackets):
• Rack mount - rack ears preassembled
• Vertical wall mount (i.e. Belly-to-Wall; cabinet door faces side)
•HX 2.5 GHz TDD remotes should be installed in a communication room that provides access only to authorized
personnel.
• The units are maintenance free. In the event of failure, only authorized personnel should handle the units.
• Only trained and qualified personnel should be allowed to install or replace this equipment.
• Verify that ambient temperature of the environment does not exceed 65°C (149°F)
3.2.2 Rack Mount Installation
3.2.2.1 Rack Installation General Safety Instructions
Review the following guidelines to help ensure your safety and protect the equipment from damage during the
installation.
•To maintain a low center of gravity, ensure that heavier equipment is installed near the bottom of the rack and load
the rack from the bottom to the top.
•Ensure that adequate airflow and ventila tio n with in the rack and around the installed components so that the safety
of the equipment is not compromised.
• EPM (1U) should be installed beneath the HX 2.5 GHz TDD unit in order to facilitate the connections
• 2U separation distance between the EPM and the top of the MA1000/MA2000 remote unit is required
• Rack nuts and screws not provided (depend on rack type)
To mount the HX 2.5 GHz TDD in a 19-in rack:
1. Determine the location of the HX 2.5 GHz TDD in the rack.
2. Secure the unit to the communication racks’ vertical uprights via at least two bracket holes on each side (one
top and one middle) using the appropriate rack nuts and screws.
Refer to Figure
3-1 and Figure 3-4 for examples of rack installations.
Examples of HX 2.5 GHz TDD Rack Installations with Additional HX4 and MA2000 QX Remotes
Figure 3-1
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 30
Examples of HX 2.5 GHz TDD Rack Installations with Additional MA2000 TSX Remote
Figure 3-2
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 31
3.2.3 Wall-Mount Installation
IMPORTANT! The wall-mo unt installation pr ocedures in this s ection are for c oncrete/brick w alls. For other wall types,
installer is responsible for following standard practices using the appropriate tools and materials.
The following secti ons pr ovide instr uctio ns for both vertic al (“ bell y-to-wa ll”) and hor izontal ( opti onal “b ack -t o wal l”) wallmount installation types.
Note the following:
•If the HX 2.5 GHz TDD is to be installed in conjunction with the EPM, the latter must be assembled to the HX 2.5
GHz TDD unit before mounting on the wall. Refer to 3.2.3.1.
•When selecting the installation location, make sure that there is enough clearance distance from the bottom to
open the HX 2.5 GHz TDD chassis door.
3.2.3.1 Assembling EPM to HX 2.5 GHz TDD (for Configurations with EPM)
Additional required items (not provided)
Six UNC 6-32, 11 mm screws for assembling EPM onto HX 2.5 GHz TDD unit.
To assemble EPM onto HX 2.5 GHz TDD
1. Remove the factory assembled rack ears from the sides of the unit.
2. Six fixed holes on top of the EPM are used for mounting the unit onto the HX 2.5 GHz TDD. See Figure
Fixed Holes on EPM for Mounting on HX 2.5 GHz TDD
Figure 3-3
3-4.
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 32
3. Place the EPM onto the top of the H X 2.5 GHz TDD unit and using six UNC 6-32, 11 mm scre ws (not provided) ,
assemble the EPM onto the HX 2.5 GHz TDD unit. See Figure
3-4.
EPM and HX 2.5 GHz TDD Assembly
Figure 3-4
3.2.3.2 Horizont al Wall Mount Installati on
Additional required tools and materials
• Philips/electric screwdriver
• Four anchors for mounting brackets on wall (anchor type depends on surface type)
To mount the HX 2.5 GHz TDD unit on the wall:
1. Remove the factory assembled rack brackets from the sides of the HX 2.5 GHz TDD unit.
2. Using ten UNC 6-32, 12 mm screws for each bracket (provided in HX kit), assemble the wall-mount brackets to
the sides of the HX 2.5 GHz TDD as shown in Figure
3-5.
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 33
Wall-Mount Bracket Assembly
Figure 3-5
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 34
3. Referring to bracket hole dimensions in Figure 3-6 (units in mm), prepare the appropriate anchors and mount
as follows:
• Mark four holes (minimum of two on per bracket) on the wall for drilling the anchors
• Drill four holes, using a hammer drill.
• Fill the holes with silicon to help weather-proof the drilled holes and to prevent erosion.
• Tap in expanding lead shield anchors
Wall-Mount Bracket Hole Dimensions
Figure 3-6
4. Insert two bolts in top anchors and tighten until bolt head is 0.5-in from surface of wall. See Figure
3-7.
Inserting First two Bolts in Anchors
Figure 3-7
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 35
5. Hang the unit and bracket assembly onto the two bolts using the key holes.
6. Insert remaining bolts (two on each side) through remaining bracket holes into anchor.
7. Tighten all four bolts.
8. Verify that HX 2.5 GHz TDD unit is tightly secured and does not shake.
Refer to Figure
3-8 for HX 2.5 GHz TDD wall-mount examples with additional MA2000 remote.
Example of HX 2.5 GHz TDD with Assembled EPM Alongside MA2000 TSX Remote
3.2.3.3 Vertical Wall Mount Installation
The vertical wall-mount brackets are optional and ordered separately.
Figure 3-8
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 36
Unpack and inspect the carton as follows:
1. Open the shipping carton and carefully unpack each unit from the protective packing material.
2. Verify that all of the items required for wall mount installation have been received (refer to Table
3-2). If any of
the listed items are missing, contact your Corning representative.
3. Check for signs of external damage. If there is any damage, call your Corning service representative.
Wall Mount Bracket (Back-to-Wall) Assembly
Quantity
Kit
Bracket
Pan Head Screw Sems UNC 6-32, 12 mm;
2
(RT/LT)
16
Stainless Steel; Used for securing bracket to HX
sides
Table 3-2. HX 2.5 GHz TDD Wall-Mount Br ac k ets Package Items List
Additional required tools and materials
• Philips/electric screwdriver
• Hammer drill
• Two anchors for hanging brackets on wall (anchor type depends on surface type) and four bolts for secure
installation
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 37
To mount the HX 2.5GHz TDD unit on the wall:
1. Remove the factory assembled rack brackets from the sides of the HX 2.5 GHz TDD unit.
2. Using eight UNC 6-32, 12 mm screws for each bracket (provided in HX 2.5 GHz TDD kit), assemble the wallmount brackets to the rear of the HX 2.5 GHz TDD side panels.
3. Referring to Figure
3-9, prepare appropriate anchors and bolts for drilling.
Wall-Mount Bracket Dimensions
4. Using bracket holes as a template, mark holes for drilling in wall.
Figure 3-9
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 38
5. Insert two bolts in top anchors and tighten until bolt head is 0.5-in from surface of wall. See Figure 3-10.
Inserting First two Bolts in Anchors
Figure 3-10
6. Hang the unit and bracket assembly onto the two bolts using the key holes.
7. Insert remaining bolts (two on each side) through remaining bracket holes into anchor and tighten.
8. Verify that HX 2.5 GHz TDD unit is tightly secured and does not shake.
Refer to Figure
3-11 for HX 2.5 GHz TDD wall mount examples with additional MA2000 remote.
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 39
Example of HX 2.5 GHz TDD with Assembled EPM Alongside MA2000 TSX Remote
Figure 3-11
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 40
3.3 Connections
Note that the HX 2.5 GHz T DD is an upgrade unit and as suc h the RF and fiber connections also interfac e existing
HX4, HX WCS and MA1000/MA2000 remote units.
3.3.1 RF Connections
3.3.1.1 RF Connections to HX4 Remote
1. Perform the HX4 service connection as follows:
Connect From Port… To Port…
Unit: HX 2.5 GHz TDD Unit: HX4
Port Name: WB RU Port Name: (ANTENNA PORT) Port 1
Port Type: N-Type duplexed Port Type: N-T ype duplexed
Table 3-3. HX4 Services Connection
Note: For SISO installations the connections are from HX 2.5 GHz TDD ANT 1 (MUX) “WB RU” port to the HX4
‘ANTENNA PORT 1”; For MI MO instal latio ns the MIMO 2 Str eam con necti ons ar e perfor med between the H X 2.5 G Hz
TDD ANT 2 (MUX) “WB RU” port and the HX4 “‘ANTENNA PORT 2”.
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 41
RF Connections Between HX 2.5 GHz and Existing HX4 (Right-SISO; Left – MIMO)
Figure 3-12
2. Connect broadband antenna coax to the HX-2.5 GHz TDD MUX module “ANT” port (two for MIMO models) and
to broadband DAS antennas. Refer to Figure
3-13 for example.
ATTENTION! Terminate any unused RF ports with a 50 ohm termination load.
Example of HX 2.5 GHz TDD Antenna Connections (SISO)
Figure 3-13
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 42
3.3.1.2 RF Connections to HX WCS
Unit:
HX 2.5 GHz TDD
Unit:
HX WCS
1. Perform the WCS service connections as follows:
Connect From Port… To Port…
Port Name: WCS RU Port Name: ANT
Port Type: Mini DIN 4.3-10 Type duplexed Port Type: Mini DIN 4.3-10 Type duplexed
Table 3-4. WCS Service Connection
Note: For SISO install ati o ns the c on nec ti ons are fr o m HX 2.5 G H z TD D ANT 1 (MUX) “WCS RU” port to t h e H X WCS
ANT 1 (MUX) “ ANT” por t; For MIMO i nstallations the MIMO 2 Stream conn ections are performed between the HX 2.5
GHz TDD ANT 2 (MUX) “WCS RU” port and the HX WCS ANT 2 (MUX) “ANT” po rt.
RF Connections Between HX 2.5 GHz and Existing HX-WCS (Right-SISO;Left – MIMO)
Figure 3-14
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 43
2. Connect broadband antenna coax to HX-2.5 GHz TDD MUX module “ANT” port of (two for MIMO models) and
to broadband DAS antennas.
ATTENTION! Terminate any unused RF ports with a 50 ohm termination load.
Example of HX 2.5 GHz TDD Antenna Connections (SISO)
Figure 3-15
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 44
3.3.1.3 RF Connections to MA1000/MA2000 Remote
This section provides instructions on how to per form ex pansion c onnectio ns between th e HX 2.5GH z TDD unit and an
MA1000/MA2000 remote unit. The RF connections between the HX 2.5 GHz TDD unit and an MA1000/MA2000
remote require an EPM unit which interfaces between the HX 2.5 GHz TDD and the service combiner unit (SCU)
required for the MA1000/MA2000 remote.
IMPORTANT! Two EPM units are r equired for MIMO installations – each one connects to one HX 2.5 GHz TDD
“ANT.” port.
To connect expansion connections
1. Connect the HX 2.5 GHz TDD MUX “ANT” mini 4.3-10 Type duplexed RF port to the EPM front panel high
band mini DIN 4.3-10 input port, as shown in Figure
3-16.
Example of Connection between HX 2.5 GHz TDD and EPM
Figure 3-16
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 45
2. Connect the four rear panel EPM low-band N-Type input ports to the corresponding SCU N-Type ANTENNA
PORTS”.
Note: The location of the SCU “ANTENNA PORTS” differ depending on model:
• SCU-4/SCU-8 units - antenna ports located on rear panel
• SCU-F/SCU-FT - antenna ports located on front panel
Example of Connections between EPM and MA2000 TSX
Figure 3-17
3. Connect the four EPM rear panel Mini DIN 4.3-10 “ANT” output ports to the wideband antennas.
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 46
3.3.1.4 Example of Multiple RF Expansion Connections
Figure 3-17 and Figure 3-18 provide examples of connections between an HX 2.5 GHz TDD unit and multiple
expansion units.
Example of Connections between HX 2.5 GHz TDD, HX4, EPM and MA2000 QX
Figure 3-18
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 47
Example of Connections between HX 2.5 GHz TDD, HX WCS and HX4
Figure 3-19
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 48
3.3.2 Fiber Connections
HX 2.5 GHz TDD support s ingle mode fiber connecti ons and interfaces to the O CH-WDM located at the headend via
the fiber patch panel.
Note: HX 2.5 GHz TDD su pports connections to OCH -WDM, whereas the HX4 a nd HX WCS support connec tions to
BUs.
To perform fiber connections
Open cabinet door to acce ss HX 2.5 GHz TDD module(s) with the fiber optic i nterface, route the DL and UL fibers
through the front door sl ot and ( s ee Figure
the OCH port, to the cor respondin g HX 2.5 GHz TDD module SC APC “Optic Port” (MIMO models inc lude t wo service
modules with fiber connections).
IMPORTANT! Keep in mind the rules for handling and connecting F/O cables.
3-20) and connect th e f iber o ptic c a ble pi gta ils f rom splice box, leading f r om
Example of HX 2.5 GHz TDD Fiber Connections to OCH (MIMO)
Figure 3-20
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 49
3.3.3 Ground Connection
Required tools and components
The following additional (not supplied) tools and components are required for connecting the system ground:
•Grounding wire - grounding wire should be sized according to local and national installation requirements. The
provided grounding lug supports 14 AWG to 10 AWG stranded copper (or 12 AWG to 10 AWG solid) wire
conductors.
Note: The length of the grounding wire depends on the proximity to proper grounding facilities.
• Phillips-head screwdriver
• Crimping tool to crimp the grounding wire to the grounding lug.
• Wire-stripping tool to remove the insulation from the grounding wire
To ground the HX 2.5 GHz TDD remote
1. Use a wire-stripping tool to remove approximately 0.4 inch (10.9 mm) of the covering from the end of the
grounding wire.
2. Insert the stripped end of the grounding wire into the open end of the grounding lug.
3. Crimp the grounding wire in the barrel of the grounding lug. Verify that the ground wire is securely attached to
the ground lug by holding the ground lug and gently pulling on the ground wire.
4. Prepare the other end of the grounding wire and connect it to an appropriate grounding point at the site to
ensure adequate earth ground.
HX 2.5 GHz TDD Grounding Lug
Figure 3-21
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 50
3.3.4 External Alarm Connections
5
Not connected
6
-48v_Alarm Door
Black
The HX 2.5GHz TD D DB-9 “Ext. Alarm” c onnector supports up to f our dry contact alarms for which the polarity fiel d
(normally open/norm ally close circuit) and severity are conf igured via the Web managem ent GUI (SC-450 v7.2 and
higher). Refer to Figure
3-21 and Table 3-5 for connector pin out and description.
HX 2.5GHz TDD External Alarm Connector Pin Out
Pin Description Wire Color
1 +48v Common Red
2 Not connected
3 Not connected
4 Not connected
7 -48v_Alarm HEX Black
8 -48v_Alarm Future Black
9 -48v_Exist Indication Black
Table 3-5. External Alarm Connector Pin Out Description
3.3.5 Power Connections
Figure 3-22
WARNING! Before connecting or disconnecting ground or power wires to the chassis, ensure that power is
disconnected from the DC circuit. To dis connect powe r, locate the circ uit breaker on th e panel board tha t servic es the
DC circuit, and sw itch th e circ uit break er to the O FF p osition. Verify zero vo ltage at the pow er ter mina ls on the c hassis
before proceeding.
DC power specifications
• Power source rating: 34-48 V DC
• Tolerance Voltage : 28-60 V DC
• Max Consumption: SISO = 90 W (3A); MIMO = 150 W(5A)
• Compatible wire size for plug: 30~12 AWG
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 51
• No. of required pairs: Minimum of one pair (up to three)
• Max. current consumption for connector: for 20 AWG = 4.5 A; (max. 5A)
To connect DC power:
Note: The internal power connections and other connections should already be connected.
1. Open cabinet door, if not already open, to access Power Supply Unit (PSU).
HX 2.5GHz TDD PSU DC Connector
2. Connect the DC wires leading from the power source to the Dinkle 2ESDFM terminal block plug ac c ordi ng to
indicated pin out on the PSU DC terminal block:
• Identify the positive and negative terminals on power source feed positions. The wiring sequence is positive to
positive and negative to negative.
• Open the terminal block screw and insert appropriate feed into the terminal block plug
• Torque the terminal block captive screw (above the installed wire lead), using a ratcheting torque screwdriver.
Recommended torque is 0.49N•m.
• Repeat above steps for all feeds
• Insert the plug into HX 2.5GHz TDD PSU DC terminal block.
Figure 3-23
3.4 Verifying Normal Operation
1. Verify that the fans are operational.
2. Verify system normal operation via the system and service LEDs – refer to section
section
Note: The HX 2.5GHz TDD monitoring and management capabilities are performed via the host OCH unit. Refer to the
SC-450 (v7.2 and higher) User Manual for the configuration and management options.
1 Operator (Composite)3 (dBm) 33
2 Operators(dBm) 30
4 Operators(dBm) 27
8 Operators(dBm) 24
Mean Gain (dB) 1 33 31
Pin1 (dBm) 0
Input IP3 (dBm) AGC OFF
Typical
Max. Intermod Distortion (dBm) -13
NF (dB) Typical
RF Output Port Impedance 50 ohm
Gain Flatness/Ripple (dB)
2
+/- 1.5
Output Power Controll range 19 ~ 34dBm
1
Factory set mean gain OCH without RIU. May be field adjusted using controller system.
2
Gain Flatness/Ripple is specified for the non-duplexed port of the system.
-13
6
Corning Restricted - Draft for public release
Appendix A: System Specifications
CMA-XXX-AEN
Page 53
RF Adjustment
#
Alarm name
Severity
Raise
Clear
Event
SNMP
LED
(RF Power reading)
power -20)
(Max output power -18)
(Max output)
(RF Power reading)
power +2)
DL RF Over
protection
(RF Power reading)
power +3)
DL RF
Adjustment
DL RF Adjustment =
Fail
DL RF Adjustment =
Success / NA
HX 2.5GHz TDD UNIT shall be capable of performing DL RF adjustment upon user request.
Adjustment targets shall be user-configurable within valid working range according to MRD (19 to 34dBm)
A change in adjus tment tar get valu e shall s et "Adjus tm ent Result" t o "N/A" ( rega rdless pre vious adj ustment result was
"Success" or "Fail")
HX2500-TDD UNIT shall be able to perform successful DL RF adjustment upon the following conditions:
- input power to OCH unit shall be -20dBm on OPTM DL port during calibration
- Optical loss on optical connection is within valid loss range defined
- Successful adjustment shall comply with target RF output power set by user
- Successful adjustment shall update time and date for adjusted device
- Upon failure in adjustm ent process DCA value s hall revert to def ault state or last good k nown configurat ion if
available, adjustment date shall be N/A
- Failure in adjustment shall include the information:
- For failure due to overpow er : “Adjustment failed due to over power, po wer exceed max value by (calculate
gap between desired value and achieve d value)
- For failure due to u nder po wer : “A dj us tment failed due to under p o wer, po wer exceed max value b y (ca lcu la te
gap between desired value and achieve d value)
Units that was never adjusted shall display N/A in adjustment information fields
DL RF Under
1
Power
DL RF Over
2
power
3
power
4
Major
Major
Major
Minor
< (Max output
> (Max output
> (Max output
< (RF Power reading) <
(RF Power reading) <
(Max output)
(RF Power reading) <
(Max output)
yes yes service
yes yes service
yes yes service
yes yes service
Corning Restricted - Draft for public release
Appendix A: System Specifications
CMA-XXX-AEN
Page 54
OverPower Protection Mechanism
HX 2.5GHz-TDD have limiter mechanism in order to limit and maintain the output level to level.
DL limiter threshold shall be the same as “Max output target” value and the range shall be at least 6dB.
To prevent HX 2.5GHz-TDD UNIT system from damage due to output over power, an automatic shutdown mechanism shall be
implemented into the HX 2.5GHz-TDD UNIT and it shall continuously monitor its output power.
Overpower criteria - In case DL output power is higher than Max output power by more than 3dB for more than 5 seconds or HX
2.5GHz-TDD UNIT Overpower state identified - unit shall turn off service in order to prevent damage.
Recovery from overpower protection shall occur by estimating Output RF power by measuring input power and taking
attenuation status into account. If estimated output power is < (Max output power -3) than service shall be recovered.
Power Down Mechanism
• Over Current Protection ( OCP)
In order to avoid danger from overcurrent due to output load failure or short-circuit, over current protection is triggered at the
range above 110% of maximum output current in which turns the power to output current down. It will automatically recover the
current at normal current range (below 100% current load). (RCU + 12V)
In case of SLOT1 and SLOT2, E-FUSE mechanism blocks the current. (3.3A~3.6A/Each mechanism works independently.) and must
be recovered by actuating signal of RCU.
• Over Voltage Protection (OVP)
When output current are being operated above the rated voltage within the range of input current, over voltage protection are
triggered at 110% ~ 140% of rated output voltage and the device is shut down.
•
Input Terminal Circuit Protection
This circuit protects the PSU from being damaged by the over current when inverse polarity are connected to the input terminal.
• Short Circuit Protection(SCP)
Even if circuits are shorted while in operation, short circuit protection protects semiconductor devices within and in case of
SLOT1, SLOT2, E-FUSE mechanism blocks the current(3.3A~3.6A/Each mechanism works independently.) and must be recovered
by actuating signal of RCU.
RF Parameters for E x ternal Wideband and WCS Input Ports
RF Parameters Wideband RU Inport Port WCS Input Port
Frequency Range
Insertion Loss
698 – 2170 MHz
2305 – 2360 MHz
0.6 dB 0.8 dB
Isolation
Return Loss
Power Rating
50 dB Min.@ 2496-2690 MHz 50 dB Min.@ 2496~2690 MHz
15 dB Min. 16 dB Min.
Avg.100 W Avg.100 W
Corning Restricted - Draft for public release
Appendix A: System Specifications
CMA-XXX-AEN
Page 55
Optical Specifications
Max. Optical Budget
Wavelength
3 dB
Optical Connector
Fiber Type
Maximum Distance Between OCH and
Remote Cabinet
SC APC
Single-mode: 9/125µm (Minimum qualifications with ANSI/TIA/EIA-568-B
series, EN50173-1 or ISO/IEC 11801)
DL: 1310 ± 10 nm (@ 25◦ C)
UL: 1550 ± 10 nm (@ 25◦ C)
2 km
Corning Restricted - Draft for public release
Appendix A: System Specifications
CMA-XXX-AEN
Page 56
Physical Specifications
SISO Services configuration: 48 lbs (21.77 kg)
Humidity
10% to 95%, non-condensing
Interfaces
Chassis:
• One mini DIN 4.3-10 Type duplexed antenna (‘ANT’) port per multiplexer
• One mini DIN 4.3-10 Type duplexed (‘WCS RU’) port per multiplexer (one for SISO
and two for MIMO configurations) for interfacing to HX WCS RF input
•One N-Type duplexed wideband (“WB RU”) port per multiplexer for interfacing to
HX4 remote unit
•One SMA-Type female 50Ω port for DL test port per multiplexer (one for SISO and
two for MIMO configurations)
• One female RJ45 Ethernet port for local craft
• One DB-9 pin female RS232 console port (engineering GUI)
• One DB-9 female external alarm connector for external dry contact alarm
Note: The information listed below is updated up to the document publishing date. Refer to the HX 2.5 GHz TDD
datasheet (CMA-461-A EN), which can be downlo aded from the Corning Par tner Portal, for the mos t updated ordering
information.
HX 2.5 GHz TDD Remote Units
Service Supported Part Number Description
2.5 GHz TDD SISO HX-2500-SISO MobileAccessHX SISO remote with support for 2500 Spark band
2.5 GHz TDD MIMO HX-2500-MIMO MobileAccessHX MIMO remote with support for 2500 Spark band
RIU Conditioner Modules
Part Number Description
RIU-BTSC-2500 RIU-4 conditioner for 2500 Spark Band; -10 to + 36 dBm input range
RIU-12-CNDTR-2500 RIU-12 Conditioner for 2500 Spark Band; -10 to +36 dBm input range
Upgrade kits
2.5 GHz TDD Module
Accessory Kits
AK-HX-1K2K-HXN-COMB
HX-2500-MODULE
MobileAccessHX accessory kit combining 1K/2K and HX; External passive module
MobileAccess HX 2.5GHz TDD band module for
upgrade from SISO to MIMO
-436-9266 • FAX: 703-848-0280 • Tech Support Hotline: 410-553-2086 or 800-787-1266 • www.corning.com/opcomm
2015 Corning Optical Communications. All rights reserved.
_HX 2.5 GHz TDD_ 709C018801 A00_17DECEMBER2015
omm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications Wireless is ISO 9001
improve, enhance and modify the features and specifications of Corning Optical Communications Wireless
able at
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.