Corning PC-400D, PC-410D, PC-420D, PC-600D, PC-610D Instruction Manual

...
Catalog Number
Model Product Top Plate 230 Volt 230 Volt Number Type Size 120 Volt 100 Volt (Non-Europe) (Europe)
PC-400D Hot Plate 5" x 7" 6795-400D 6797-400D 6798-400D 6796-400D
(12.7 x 17.8 cm)
PC-410D Stirrer 5" x 7" 6795-410D 6797-410D 6798-410D 6796-410D
(12.7 x 17.8 cm)
PC-420D Stirrer/ 5" x 7" 6795-420D 6797-420D 6798-420D 6796-420D
Hot Plate (12.7 x 17.8 cm)
PC-600D Hot Plate 10" x 10" 6795-600D 6797-600D 6798-600D 6796-600D
(25.4 x 25.4 cm)
PC-610D Stirrer 10" x 10" 6795-610D 6797-610D 6798-610D 6796-610D
(25.4 x 25.4 cm)
PC-620D Stirrer/ 10" x 10" 6795-620D 6797-620D 6798-620D 6796-620D
Hot Plate (25.4 x 25.4 cm)
Controller
Instruction Manual
For All Hot Plates, Stirrers,and Stirrer/Hot Plates with Digital Displays and for the
6
795
PR Temperature Controller
iiiii
Acerca de este Manual
Este manual está diseñado para ayudarlo a optimizar el uso desu nueva parrilla de calentamiento, agitador, parrilla de calentamiento/agitador ó contolador de temperatura. El manual está disponible en Inglés, Francés, Alemán, Japonés, Coreano, Mandarín Chino y Español y en la sección de literatura de productos de la página Web de Corning http://www.corning.com/lifesciences.
Voltaje de los productos
Parrillas de calentamiento, agitadores, parrillas de calentamiento/agitador están disponibles en diferentes voltajes. Antes de usarla, revise que la unidad recibida tiene el voltaje correcto para su locación.
Registro de garantía
Llene y envie por correo la tarjeta de registroo envie esta information a través de nuestra página web http://www.corning.com/lifesciences/warranty para validar por dos años la garantía de Parrillas de calentamiento, agitadores, parrillas de calentamiento/agitador.
About This Manual
This manual is designed to assist you in optimal usage of your new hot plate, stirrer, stirrer/hot plate or temperature controller. The manual is available in English, French, German, Japanese, Korean, Mandarin Chinese and Spanish in the product literature section of Corning’s website http://www.corning.com/lifesciences.
Product Voltages
Hot plates, stirrers, and stirrer/hot plates are available in different voltages. Before initial use, check that the unit you received is the correct voltage for your location.
Warranty Registration
Filling out and mailing the attached Warranty Registration Card or submitting this information online at http://www.corning.com/lifesciences/warranty will validate the hot plate, stirrer or stirrer/hot plate’s two year warranty.
Mode d’emploi
Ce mode d’emploi a pour but de vous aidez à utiliser votre nouvelle plaque chauffante, agitateur, agitateur chauffant ou contrôleur de température, de manière optimale. Il est disponible en français, anglais, allemand, espagnol, japonais et chinois. Vous pouvez également le consulter et le télécharger sur notre site dans la section «product literature». http://www.corning.com/lifesciences
Voltage des appareils
Les plaques chauffantes, agitateurs et agitateurs chauffants sont disponibles en différents voltages. Vérifiez avant la première utilisation que l’appareil fourni possède le voltage adéquat.
Garantie
Remplissez et envoyez la carte de garantie incluse ou remplissez ces renseignements en ligne sur notre site http://www.corning.com/lifesciences/warranty.
Votre garantie de deux ans sera alors activée.
Zu dieser Gebrauchsanleitung
Diese Gebrauchsanleitung wurde erstellt, um Ihnen dabei zu helfen, Ihre neu erworbenen Geräte wie Heizplatte, Rührer, Rührer/Heizplatte oder Temperaturregler optimal zu gebrauchen. Diese Gebrauchsanleitung ist in Englisch, Französisch, Deutsch, Japanisch, Koreanisch, Mandarin Chinesisch und Spanisch sowie im Abschnitt zur Produktliteratur der Corning Internetseite unter http://www.corning.com/lifesciences erhältlich.
Produkt Netzspannungen
Heizplatten, Rührer und Rührer/Heizplatten sind für verschiedene Netzspannungen erhältlich. Kontrollieren Sie bitte vor dem ersten Gebrauch, ob das Gerät, das Sie erhalten haben, über die korrekte Netzspannung für Ihren Standort verfügt.
Garantie-Registrierung
Das Ausfüllen und Zusenden der beigefügten Karte für Garantie-Registrierung oder das Einreichen dieser Information online unter http://www.corning.com/lifesciences/warranty bestätigt die zwei Jahre Garantie für Heizplatte, Rührer oder Rührer/Heizplatte.
1
Table of Contents
Safety Information . . . . . . . . . . . . . . . . . . . . . . 2
Operating Conditions . . . . . . . . . . . . . . . . . . . 3
Product Controls and Indicators . . . . . . . . . . . 4
Product Connections . . . . . . . . . . . . . . . . . . . . 4
Stirring Instructions . . . . . . . . . . . . . . . . . . . . . 5
Heating Instructions (without the External
Temperature Controller) . . . . . . . . . . . . . . . . .
6
Heating Instructions (with the External Temperature Controller, Cat. No. 6795PR) . .
6
Heating Operation Principles . . . . . . . . . . . . . 7
Heating Operation Safety . . . . . . . . . . . . . . . . 9
Product Repair . . . . . . . . . . . . . . . . . . . . . . . . . 9
Product Maintenance . . . . . . . . . . . . . . . . . . . . 9
Optional Accessories . . . . . . . . . . . . . . . . . . . 11
Replacement Parts . . . . . . . . . . . . . . . . . . . . . 12
Technical Specifications . . . . . . . . . . . . . . . . 12
Product Size and Dimensions . . . . . . . . . . . . 13
Frequently Asked Questions . . . . . . . . . . . . . 13
CE, WEEE . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Warranty Statement . . . . . . . . . . . . . . . . . . . . 15
32
Safety Information
This instruction manual contains important operating and maintenance instructions which must be read, understood, and followed by the prod­uct user. Failure to use this product according to this instruction manual may degrade or defeat the protection normally provided by this product. Read this instruction manual prior to product use and keep this instruc­tion manual for future reference.
Product Symbols
Caution - Risk of danger: Cautions that there is materi­al in the instruction manual which must be read, under­stood, and followed in order to preserve product safety features.
Caution – Hot Surface: Cautions that the top plate is too hot to touch.
Indicates that the unit is plugged into power supply.
Indicates that the accessory external temperature con­troller is properly plugged into the unit.
Warnings
Personal Injury
Do not use this product in a manner other than as stated in the
Operating Conditions section of this manual as the protection provided by the equipment may be impaired.
This product is designed for use in laboratory environments by persons
knowledgeable in safe laboratory practices.
Always wear safety glasses and other appropriate protective equipment
when operating this product.
Electric Shock
This product must be connected to a grounded power outlet for safe
functioning.
Use only the power cord supplied with the product.The power cord is the device available for full disconnect from mains
input.
Position the product for use so that the power cord can be easily dis-
connected without having to move the product.
Disconnect the power cord before moving or cleaning the unit.
Product Damage
Keep the product dry and clean.Do not immerse the product for cleaning.The ceramic top may break if impacted.The maximum gross weight placed on the top surface must not exceed
11Kg (25 lbs.)
These units are not explosion or spark proof.Do not heat or stir volatile or flammable materials.Do not operate this product near volatile or flammable materials.Do not use this product with a metal vessel.
Operating Conditions
Corning hot plates, stirrers, and stirrer/hot plates are designed to provide safe functioning under the following conditions:
Indoor useAltitude up to 2000 meters (6,500 feet)Ambient temperatures of 0°C to 30°CProduct should be placed on a flat surface at least 30.5 cm (12") from
walls, 122 cm (48") from ceilings, and 30.5 cm (12") from other hot plates if using multiple units.
Maximum relative humidity of 80% for temperatures up to 31°C,
decreasing linearly to 50% relative humidity at 40°C.
Pollution Degree 2: Any foreign matter that may accumulate on or
within the product during normal use is not electrically conductive.
Installation Category II: Product is designed for connection to an
electrical branch circuit inside a building with main supply voltage fluctuations not exceeding ±10% of the nominal voltage.
Loading...