Optical Interface Unit (OIU)
Quick Installation Sheet
CMA-263-AEN
GENERAL INFORMATION
• OIMe —optical module only; ber jumper is not included —
compatible MTP®-LC APC harness cable is ordered separately
(see Section 2 of this document)
• OIU chassis is supplied empty and only includes the factory-assembled
fan module (FAM). All other modules (i.e., power supplies, controller,
OIMe, OIXs, and FMMs) are ordered separately and must be installed.
This document describes the installation and connection procedures for the Corning® optical network evolution (ONE™)
solutions optical interface unit (OIU) and relevant modules.
Note: The instructions for installing and connecting ber main modules (FMMs) in the OIU chassis are not in the scope of this
document. For details, refer to the quick installation sheet provided with the module.
. REQUIRED KITS
The following kits are required for installing the OIU. If any of the listed items are missing, contact your Corning
representative.
OIU KitQtyItem
OIU Chassis (with blank panels) —
with factory-assembled FAM and rack brackets
Fan Module (FAM) — one unit hosting four fans
(factory installed in chassis rear)
RJ45 100 Base-T Ethernet Communication Cable,
L = 2-2.15 m (P/N: 705900003) — ACM management
connection
1
2
1
Table 1. Kits Required for OIU Installation
Corning Optical Communications
Quick Installation Sheet | CMA-263-AEN | Page 1
Page 2
. REQUIRED KITS (CONTINUED)
OIM Kit (1-12 according to order)QtyItem
Optical Interface Module 1
PSM Kit (AC or DC modules —
QtyItem
1 or 2 kits according to order)
PSM-AC: 100-240 VAC Power Supply Module including
1
standard IEC 60320-1 C13 cable
PSM-DC: 48 V DC Power Supply Module; 9 A maximum.;
Includes six-pin terminal block connector
Note: For modules with ejectors (i.e., OIM, OIX, and ACM)
– verify that the ejectors are completely open when
inserting in dedicated slot and then push in until
the module clicks in to the backplane. Figure 4
shows example of module type captive screws and
ejectors.
Step 1: Refer to Figure 5 for module locations. Remove
blank panel and slide in the relevant module
(chassis slots are 100 percent mistake proof):
• (One) ACM
• (One to two) PSM – for single-power supply
installations, install the PSM in either (PSM) slot.
• (One to two) OIX – for single OIX installations,
the second OIX slot must be occupied with an
expander termination module (ETM).
• (One to 12) OIM — no need to terminate
unoccupied OIM slot.
Step 2: Secure modules into the OIU backplane by:
Figure 4.Module Ejectors
• Closing ejectors rmly (for relevant modules)
• Tightening the captive screws
. GROUND CHASSIS
The grounding connection is performed via a two-hole, standard
barrel grounding lug located on the chassis rear panel (see Figure 6).
Prise de terre du châssis OIU:
La mise à la terre est réalisée en utilisant une cosse deux trous a
œillet standard, située à l’arriè du chassis OIU (voir Figure 6).
Figure 5. Location of OIU Chassis Modules
Figure 6. Location of Chassis Grounding Lug
Corning Optical Communications
Quick Installation Sheet | CMA-263-AEN | Page 4
Page 5
. GROUND CHASSIS (CONTINUED)
Step 1: Use a wire-stripping tool to remove approximately
0.4- in (10.9 mm) of the covering from the end of
the grounding wire.
Step 2: Insert the stripped end of the grounding wire into
the open end of the grounding lug.
Step 3: Crimp the grounding wire in the barrel of the
grounding lug. Verify that the ground wire is
securely attached to the ground lug by holding the
ground lug and gently pulling on the ground wire.
Step 4: Prepare the other end of the grounding wire and
connect it to an appropriate grounding point at the
site to ensure adequate earth ground.
. FIBER CONNECTIONS
Using an MTP®-LC APC harness cable:
• Connect the harness cables’ MTP® connector to the
OIM MTP connector
• Remove the protective plastic covers and connect the
(3) LC APC connection bers to the FMU EDGE™ module
LC APC connections. See Figure 7.
ATTENTION! Take note of the ber numbering (i.e., 1/2/3).
. EXPANDER CONNECTIONS TO HEU
RF expander connections between the OIU and HEU are
performed using the ERFC cable (included in HEU order)
and are described in the HEU quick installation sheet
(CMA-267-AEN) provided with the unit. See Figure 8 for
general view of connections.
Figure 7. OIMs Fiber Connections
Figure 8. OIX-to-RIX Expander Connection
Corning Optical Communications
Quick Installation Sheet | CMA-263-AEN | Page 5
Page 6
. POWER UP
Note: Only AC power connections are decsribed in this document. Refer to PSM-DC quick
installation sheet (CMA-365-AEN) provided with PSM-DC for wiring pinout.
Figure 9. PSM-AC
Interfaces
ATTENTION!
• Approved power cable – the entire length of the
power cable (or exible cord) and the insulation must
be intact. The cable must be rmly connected to both
the electrical plug and the unit itself.
• Standard plug – the use of a standard plug is
mandatory. The use of a non-standard power plug can
cause electrocution! Also, plugging a non-standard
plug into a standard socket that does not correspond
to the plugs’ shape, can damage the socket making it
a safety hazard.
• Always disconnect all AC power sources from the unit
before servicing (i.e., maintenance).
To power up the unit:
Connect the PSM-AC power connector to the AC power
source using the provided AC power cable and turn
power switch on. See Figure 9 for AC connector location.
• Power input: 100-240 VAC
• Power consumption (fully loaded chassis):
300 W (maximum);
ATTENTION!
• Câble d’alimentation qui est approuvé —la totalité
de la longueur du câble d’alimentation (ou cordon
souple) et de l’isolation doit être intact. Le câble doit
être bien connecté à la fois à la prise électrique et
l’appareil.
• Prise électrique standard — l’utilisation d’une
che standard est obligatoire. L’utilisation d’un
cordon d’alimentation non standard peut entraîner
l’électrocution! De meme, brancher une che nonstandard sur une prise standard ne correspondant
pas à la forme de de la che, peut endommager la
Prise, ce qui en fait un danger de sécurité.
• Débrancher toujours toutes les sources
d’alimentation CA de l’unité avant l’entretien.
Pour mettre l’unité sous tension:
Branchez la prise d’alimentation du PSM-AC à la source
d’alimentation secteur à l’aide du câble d’alimentation
secteur fourni et allumer l’interrupteur. Voir Figure 9
pour l’emplacement du connecteur AC.
• Alimentation: 100-240 VAC
Corning Optical Communications
• Consommation maximale électrique
(pour les châssis entièrement charges):
300 W ; 18 W par OIM
Quick Installation Sheet | CMA-263-AEN | Page 6
Page 7
. MANAGEMENT CONNECTIONS
Using the provided RJ45/RJ45 communication cable connect
the OIU ACM control module as follows:
• Referring to Figure 10 — for congurations with one
HCM and up to four ACMs (e.g., one HEU and four OIUs),
directly connect as follows:
From any ….To any ….
ACM “INTERNAL
(TO HCM)” port
HCM “INTERNAL
(TO ACM)” port
• For congurations with one HCM and more than four
ACMs (e.g. , 4x4 HEU-OIU congurations) where there
are only four available HCM “INTERNAL” ports:
From any ….To any ….
ACM”INTERNAL
(TO ACM)” port
Other available ACM
module “INTERNAL
(TO ACM)” port
Refer to Figure 11 for schematic example of management
connections.
Note: Main HEU refers to HEU with HCM.
Figure 10. Direct OIU Management Connection
Figure 11. Schematic Example of 4x4 Management
Connections
Corning Optical Communications
Quick Installation Sheet | CMA-263-AEN | Page 7
Page 8
. VERIFY NORMAL OPERATION
If OIU chassis is powered on, verify that the OIM and ACM (see Figure 12) module LEDs indicate normal operation:
Figure 12. OIM and ACM Status LEDs
ModuleLEDDescription
PSMPWR StatusGreen steady — power input detected
Off — no power
OIMLINK 1/2/3Steady green — optical link power to/from the connected remote is normal
Off – no optical power from remote detected
RUNBlinking green — OIM software has initialized and is up and running
Off — power off
PWRSteady green — power input detected in OIMe
ACMPWRSteady green — power input detected by ACM
RUNBlinking green — ACM software up and running
SYSSteady green — overall status of the managed system OK
FANSteady green — normal operation status for all fans