Cornelius IWCS224, IACS227, IWCS227, AC322, WC322 Specifications

...
built
for
the
long
haul.
ice systems
Buying an ice machine is a decision you will live with for a long time. For the money, you want an ice machine that delivers more performance for less cost, over a longer period of time. You want Cornelius.
Efficient Water/Electrical
Compressors and condensers are matched precisely to provide the perfect
balance between water and electrical use. All solid-state circuitry
maximizes reliability.
Improved Serviceability
A self-insulating ABS evaporator housing offers worry-free durability.
Flexible Capacities
22", 27", 30", 44" and 48" cabinet sizes with capacities ranging from 200 to 2,500 lbs. per day.
Future Proof™ Refrigerants
Our ice machines are engineered with Future Proof™, zero ozone depleting
refrigerants.
Limited Lifetime Warranty*
Stainless steel panels and frames are guaranteed against corrosion for life.
*See warranty for details.
BUILT FOR
BUILT FOR
*See warranty for details.
THE LONG HAUL.
THE LONG HAUL.
Self-Insulated ABS Evaporator Housing
Nickel-Plated Copper Evaporator
Insulated, Double-Wall Bulkhead
In-Line Water Pump
Microban
®
Antimicrobial Product Protection
Programmable Water Control
Quick-Change Merchandising Panel
Front-Mounted LED
Future Proof R-404a Refrigerant
Exclusive Ice Harvest System
Front Serviceable
PRODUCTION CHART
AIR-COOLED
Water Temperature (˚F)
Air Temp (˚F) 50 70 80
70 46 lbs. 41 lbs. 40 lbs.
80 44 lbs. 40 lbs. 40 lbs.
90 42 lbs. 38 lbs. 35 lbs.
Series 50†
Series 200
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
ACS50SL Air-Cooled R-134a 115/60/1 15 15 110 lbs. 100 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser Capacity
Model Rate Use Consumption Water Use Storage Bin
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. ( lbs.)
IACS224 150 25.0 10.6 n/a 77
IWCS224 145 22.0 10.5 195 77
IACS227 240 27.0 9.8 n/a 75
IWCS227 240 27.0 7.6 160 75
IACS-224 PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 251 lbs. 226 lbs. 214 lbs. 50 221 lbs. 179 lbs. 171 lbs.
70 226 lbs. 198 lbs. 177 lbs. 70 218 lbs. 165 lbs. 155 lbs.
90 167 lbs. 150 lbs. 137 lbs. 90 164 lbs. 145 lbs. 130 lbs.
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
IACS224
Air-Cooled
R-404a 115/60/1 15 15 182 lbs. 146 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
IWCS224
Water-Cooled
R-404a 115/60/1 15 15 182 lbs. 146 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
IACS227 Air-Cooled R-404a 115/60/1 20 20 230 lbs. 198 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
IWCS227
Water-Cooled
R-404a 115/60/1 20 20 230 lbs. 198 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser Capacity
Model Rate Use Consumption Water Use Storage Bin
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. (lbs.)
ACS50 38 38.5 14.3 n/a 25
DIMENSIONS/CAPACITY
Model Nominal Cabinet
Number Capacity Dimensions Finish
ACS50 46 lbs. 15"w x 24"d x 34"h E
DIMENSIONS/CAPACITY
Model Nominal Cabinet
Number Capacity Dimensions Finish
IACS224/IWCS224 251 lbs 24"w x 24"d x 39"h Polyethylene
IACS227/IWCS227 326 lbs 27"w x 28"d x 39"h SS
†Limited lifetime warranty not applicable to this model.
ACS50
IACS227
Rated in accordance with ARI Standard 810-91 and 820-88.
Rated in accordance with ARI Standard 810-91 and 820-88.
24"
15"
34 "
28 "
27 "
39 "
C U B
E
R
S
4
IACS224
24"
24"
39"
IACS-227 PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 326 lbs. 295 lbs. 271 lbs. 50 330 lbs. 300 lbs. 270 lbs.
70 312 lbs. 290 lbs. 267 lbs. 70 310 lbs. 280 lbs. 260 lbs.
90 263 lbs. 240 lbs. 220 lbs. 90 280 lbs. 240 lbs. 230 lbs.
C U B
E
R
S
5
Series 300"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC322/XAC330 269 16.7 8.5 n/a
XWC322/XWC330 269 16.7 6.8 149
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC322 342 lbs. 22"w x 24
1
2
"d x 23"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XAC330
342 lbs.30"
w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC322
334 lbs.22"
w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC330
334 lbs.30"
w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 342 326 312 50 334 302 292
70 338 310 304 70 315 287 285
90 285 269 258 90 299 281 268
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC322 Air-Cooled R-404a 115/60/1 20 20 148 lbs. 123 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC322
Water-Cooled
R-404a 115/60/1 20 20 144 lbs. 119 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC330 Air-Cooled R-404a 115/60/1 20 20 163 lbs. 136 lbs.
50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC330
Water-Cooled
R-404a 115/60/1 20 20 155 lbs. 128 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC322/XWC322
Rated in accordance with ARI Standard 810-91.
31
3
4
"
22 "
71 "
23 "
Series 322†
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
AC322 Air-Cooled R-404a 115/60/1 20 20 138 lbs. 122 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
WC322
Water-Cooled
R-404a 115/60/1 20 20 134 lbs. 118 lbs. 50°F-100°F 45°F-90°F 20-120 psi 110-126
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
AC322 270 23.9 8.7 n/a
WC322 270 23.9 8.7 170
PRODUCTION CHART
AIR-COOLED WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 359 lbs. 321 lbs. 312 lbs. 50 341 lbs. 300 lbs. 281 lbs.
70 333 lbs. 313 lbs. 277 lbs. 70 326 lbs. 289 lbs. 266 lbs.
90 305 lbs. 270 lbs. 249 lbs. 90 315 lbs. 270 lbs. 251 lbs.
AC322/B122AP
Rated in accordance with ARI Standard 810-91.
†Limited lifetime warranty does not apply to this model.
22 "
29"
397⁄8"
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
AC322 359 lbs. 22"w x 23
1
2
"
d x 16
3
8
"
h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
WC322 341 lbs. 22"w x 23
1
2
"
d x 16
3
8
"
h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
163⁄8"
231⁄2"
Series 600"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC630 547 16.3 6.9 n/a
XWC630 589 17.4 5.6 116
XRC630 547 16.3 6.9 n/a
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC630 Air-Cooled R-404a 208/230/60/1 20 20 201 lbs. 172 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC630
Water-Cooled
R-404a 208/230/60/1 20 20 197 lbs. 168 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC630
AC Remote*
R-404a 208/230/60/1 20 20 209 lbs. 180 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 722 lbs. 648 lbs. 634 lbs. 50 671 lbs. 603 lbs. 556 lbs. 50 722 lbs. 648 lbs. 634 lbs.
70 672 lbs. 609 lbs. 589 lbs. 70 661 lbs. 594 lbs. 551 lbs. 70 672 lbs. 609 lbs. 589 lbs.
90 606lbs. 547 lbs. 521 lbs. 90 652 lbs. 589 lbs. 542 lbs. 90 606 lbs. 547 lbs. 521 lbs.
XAC630/B530AP
*Use Remote Condenser CR-800.
Rated in accordance with ARI Standard 810-91.
25 "
3
2
5
1
6
"
30 "
73 "
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC630 722 lbs. 30"w x 24
1
2
"d x 25"h SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC630 671 lbs. 30"w x 24
1
2
"d x 25"h SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC630 722 lbs.
30"w x 24
1
2
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
C U B
E
R
S
6
Series 500"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC522/XAC530 475 17.0 6.7 n/a
XWC522/XWC530 475 17.0 5.8 133
XRC522/XRC530 475 17.0 6.7 n/a
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC522 600 lbs. 22"w x 24
1
2
"d x 23"h SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC522
600 lbs.
22"w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC522
540 lbs.
22"w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XAC530
540 lbs.
30"w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC530
600 lbs.
30"w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC530
600 lbs.
30"w x 24
1
2
"
d x 23"hSS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC522 Air-Cooled R-404a 115/60/1 20 20 162 lbs. 135 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC522
Water-Cooled
R-404a 115/60/1 20 20 145 lbs. 117 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XRC522
AC Remote*
R-404a 115/60/1 20 20 165 lbs. 141 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC530 Air-Cooled R-404a 115/60/1 20 20 170 lbs. 143 lbs.
50°F-100°F 45°F-90°F 20-80 psi 110-126
XWC530
Water-Cooled
R-404a 115/60/1 20 20 153 lbs. 125 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XRC530
AC Remote*
R-404a 115/60/1 20 20 180 lbs. 149 lbs. 50°F-100°F 45°F-90°F 20-80 psi 110-126
XAC522/XAC530
Rated in accordance with ARI Standard 810-91.
23 "
32
5
1
6
"
30 "
61 "
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 600 596 542 50 540 515 489 50 600 596 542
70 597 549 536 70 540 494 475 70 597 549 536
90 513 475 454 90 532 475 454 90 513 475 454
* Use Remote Condenser CR-500.
Series 800"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC830 666 16.3 6.9 n/a
XWC830 700 17.4 5.6 116
XRC830 666 16.3 6.9 n/a
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC830 Air-Cooled R-404a 208/230/60/1 20 20 211 lbs. 182 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC830
Water-Cooled
R-404a 208/230/60/1 20 20 207 lbs. 178 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC830
AC Remote*
R-404a 208/230/60/1 20 20 223 lbs. 194 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 771 lbs. 752 lbs. 740 lbs. 50 780 lbs. 742 lbs. 715 lbs. 50 771 lbs. 752 lbs. 740 lbs.
70 747 lbs. 730 lbs. 712 lbs. 70 761 lbs. 724 lbs. 693 lbs. 70 747 lbs. 730 lbs. 712 lbs.
90 703 lbs. 666 lbs. 621 lbs. 90 736 lbs. 700 lbs. 676 lbs. 90 703 lbs. 666 lbs. 621 lbs.
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 950 lbs. 901 lbs. 890 lbs. 50 959 lbs. 916 lbs. 873 lbs. 50 950 lbs. 901 lbs. 890 lbs.
70 918 lbs. 877 lbs. 860 lbs. 70 939 lbs. 904 lbs. 869 lbs. 70 918 lbs. 877 lbs. 860 lbs.
90 854 lbs. 830 lbs. 799 lbs. 90 900 lbs. 887 lbs. 861 lbs. 90 854 lbs. 830 lbs. 799 lbs.
XAC830/B842SS
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-800.
25 "
32 "
30 "
42 "
73 "
C U B
E
R
S
7
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC830 771 lbs. 30"w x 24
1
2
"d x 25"h SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC830 780 lbs. 30"w x 24
1
2
"d x 25"h SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC830 771 lbs.
30"w x 24
1
2
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
Series 1000"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1030 830 13.2 7.0 n/a
XWC1030 887 13.2 5.5 112.7
XRC1030 830 13.2 7.0 n/a
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1030 Air-Cooled R-404a 208/230/60/1 20 20 226 lbs. 197 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1030
Water-Cooled
R-404a 208/230/60/1 20 20 215 lbs. 186 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1030
AC Remote*
R-404a 208/230/60/1 20 20 225 lbs. 196 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XAC1030/B1048SS
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-1200.
32 "
48 "
30 "
73"
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1030 950 lbs. 30"w x 25" d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC1030 959 lbs.
30"w x 25" d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC1030 950 lbs.
30"w x 25" d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
25"
Series 1400"Xtreme"
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1444 Air-Cooled R-404a 208/230/60/1 30 30 317 lbs. 274 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1444
Water-Cooled
R-404a 208/230/60/1 30 30 295 lbs. 252 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1444
AC Remote*
R-404a 208/230/60/1 30 30 308 lbs. 265 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1444 1275 14.3 6.8 n/a
XWC1444 1374 14.3 5.5 130
XRC1444 1275 14.3 6.8 n/a
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-1400.
XAC1444/B1048SS
44"
73 "
32 "
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1444 1630 lbs. 44"w x 24
3
4
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC
1444
1505 lbs.
44"w x 24
3
4
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC
1444
1630 lbs.
44"w x 24
3
4
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
25 "
C U B
E
R
S
8
Series 1200"Xtreme"
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1230 1019 14.6 6.5 n/a
XWC1230 1029 14.6 5.2 79.8
XRC1230 1019 14.6 6.5 n/a
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1230 Air-Cooled R-404a 208-230/60/1 20 20 258 lbs. 229 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1230
Water-Cooled
R-404a 208-230/60/1 20 20 234 lbs. 205 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1230 AC Remote* R-404a 208-230/60/1 20 20 247 lbs. 218 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-1200.
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1230 1177 lbs. 30"w x 24
1
2
"d x 28"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC1230 1062 lbs.
30"w x 24
1
2
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC1230 1177 lbs.
30"w x 24
1
2
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XAC1230/B1048SS
32 "
48 "
30 "
76 "
25” (water / remote cooled)
28 " (air-cooled)
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 1177 lbs. 1137 lbs. 1070 lbs. 50 1062 lbs. 1055 lbs. 1042 lbs. 50 1177 lbs. 1137 lbs. 1070 lbs.
70 1143 lbs. 1098 lbs. 1039 lbs. 70 1059 lbs. 1046 lbs. 1027 lbs. 70 1143 lbs. 1098 lbs. 1039 lbs.
90 1076 lbs. 1019 lbs. 977 lbs. 90 1052 lbs. 1029 lbs. 1006 lbs. 90 1076 lbs. 1019 lbs. 977 lbs.
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 1630 lbs. 1505 lbs. 1470 lbs. 50 1505 lbs. 1391 lbs. 1362 lbs. 50 1630 lbs. 1505 lbs. 1470 lbs.
70 1537 lbs. 1416 lbs. 1380 lbs. 70 1473 lbs. 1385 lbs. 1346 lbs. 70 1537 lbs. 1416 lbs. 1380 lbs.
90 1340 lbs. 1275 lbs. 1198 lbs. 90 1409 lbs. 1374 lbs. 1315 lbs. 90 1340 lbs. 1275 lbs. 1198 lbs.
C U B
E
R
S
C H U N K
L E T S
9
Series 2448
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
IRC2448 AC Remote* R-404a
208-230/60/1
30 30 396 lbs. 335 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-235
IRC2448-3PH AC Remote* R-404a
208-230/60/3
30 30 396 lbs. 335 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-235
IWC2448 Water-Cooled R-404a
208-230/60/1
30 30 388 lbs. 327 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-235
IRC2448/B1048SS
32"
48"
76"
PRODUCTION CHART
REMOTE AIR-COOLED REMOTE WATER-COOLED
Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 2460 lbs. 2288 lbs. 2224 lbs. 50 2534 lbs. 2240 lbs. 2138 lbs.
70 2401 lbs. 2244 lbs. 2186 lbs. 70 2500 lbs. 2221 lbs. 2096 lbs.
90 2163 lbs. 2024 lbs. 1938 lbs. 90 2283 lbs. 2200 lbs. 2057 lbs.
DIMENSIONS/CAPACITY
Model Nominal Cabinet
Number Capacity Dimensions Finish
IRC2448 2460 lbs. 48w x 23
1
2
"d x 28"h SS
IRC2448-3PH 2460 lbs. 48w x 23
1
2
"d x 28"h SS
IWC2448
2534 lbs.
48w x 23
1
2
"d x 28"h
SS
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
IRC2448 2024 15.0 8.0 n/a
IRC2448-3PH 2024 15.0 8.0 n/a
IWC2448 2200 15.0 6.0 135
*Use Remote Condenser CR-2400.
28"
48"
Series 1800"Xtreme"
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
XAC1844 Air-Cooled R-404a 208/230/60/1 30 30 367 lbs. 324 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XWC1844
Water-Cooled
R-404a 208/230/60/1 30 30 345 lbs. 302 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
XRC1844
AC Remote*
R-404a 208/230/60/1 30 30 358 lbs. 315 lbs. 50°F-100°F 45°F-90°F 20-80 psi 198-253
ARI CERTIFIED PERFORMANCE
Ice Harvest Potable Water KWH Condenser
Model Rate Use Consumption Water Use
Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs.
XAC1844 1600 14.5 7.3 n/a
XWC1844 1610 14.5 6.0 150
XRC1844 1600 14.5 7.3 n/a
Rated in accordance with ARI Standard 810-91.
*Use Remote Condenser CR-2400.
XAC1844/B1048SS
44"
73 "
32 "
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
XAC1844 1947 lbs. 44"w x 24
3
4
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XWC
1844
1700 lbs.
44"w x 24
3
4
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
XRC
1844
1947 lbs.
44"w x 24
3
4
"d x 25"h
SS
3
8
" male flare
9
16
" I.D. x
3
4
" O.D.
7
8
" diameter hole
25 "
PRODUCTION CHART
AIR-COOLED WATER-COOLED REMOTE AIR-COOLED
Water Temperature (˚F) Water Temperature (˚F) Water Temperature (˚F)
Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80 Air Temp (˚F) 50 70 80
50 1947 lbs. 1637 lbs. 1328 lbs. 50 1700 lbs. 1650 lbs. 1610 lbs. 50 1947 lbs. 1637 lbs. 1328 lbs
70 1928 lbs. 1619 lbs. 1309 lbs. 70 1660 lbs. 1630lbs. 1580 lbs. 70 1928 lbs. 1619 lbs. 1309 lbs.
90 1909 lbs. 1600 lbs. 1290 lbs. 90 1640 lbs. 1610 lbs. 1550 lbs. 90 1909 lbs. 1600 lbs. 1290 lbs.
C H U N K
L E T S
10
Series 1000
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCC-1001A 1015 lbs. 22"w x 24"d x 27"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-1001W 1015 lbs. 22"w x 24"d x 27"h SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-1001R 1015 lbs. 22"w x 24"d x 27"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 1015 lbs. 909 lbs. 856 lbs.
70ºF 940 lbs. 839 lbs. 790 lbs.
90ºF 831 lbs. 748 lbs. 711 lbs.
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCC-1001A
Air-Cooled R-404a 208-230/60/1 15 15 210 lbs. 194 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCC-1001W
Water-Cooled
R-404a 208-230/60/1 15 15 210 lbs. 194 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCC-1001R*
AC Remote
R-404a 208-230/60/1 15 15 210 lbs. 194 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
*Use Remote Condenser WC1.
Series 700
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCC-700A 636 lbs. 14
1
2
"w x 25"d x 24
1
2
"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-700W
636 lbs. 14
1
2
"w x 25"d x 24
1
2
"h
SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-700R
636 lbs. 14
1
2
"w x 25"d x 24
1
2
"h
SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCC-700A Air-Cooled R-404a 115/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCC-700W
Water-Cooled
R-404a 115/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCC-700R*
AC Remote
R-404a 115/60/1 20 20 138 lbs. 126 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCC-701A
Air-Cooled R-404a 208-230/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCC-701W
Water-Cooled
R-404a 208-230/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
*Use Remote Condenser WCU.
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 636 lbs. 570 lbs. 536 lbs.
70ºF 616 lbs. 550 lbs. 518 lbs.
90ºF 570 lbs. 513 lbs. 489 lbs.
WCC700/B842SS
32"
42"
14
1
2
"
721⁄2
"
241⁄2"
WCC1001/B1048SS
32"
48"
2
2
"
75"
27"
Series 500
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCC-500A 391 lbs. 14
1
2
"w x 25"d x 24
1
2
"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-500W
391 lbs. 14
1
2
"w x 25"d x 24
1
2
"h
SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCC-500A Air-Cooled R-404a 115/60/1 15 15 154 lbs. 142 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCC-500W
Water-Cooled
R-404a 115/60/1 15 15 154 lbs. 142 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 391 lbs. 351 lbs. 330 lbs.
70ºF 369 lbs. 329 lbs. 310 lbs.
90ºF 317 lbs. 285 lbs. 271 lbs.
32
5
1
6
"
WCC500/B530SS
30"
141⁄2"
721⁄2"
241⁄2"
C H U N K
L E T S
F
L
A K
E
R
S
11
Series 2000
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCC-2001A 1999 lbs. 30"w x 24"d x 28"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-2001W 1999 lbs. 30"w x 24"d x 28"h SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCC-2001R 1999 lbs. 30"w x 24"d x 28"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 1999 lbs. 1790 lbs. 1684 lbs.
70ºF 1735 lbs. 1549 lbs. 1458 lbs.
90ºF 1403 lbs. 1262 lbs. 1201 lbs.
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCC-2001A
Air-Cooled R-404a 208-230/60/1 15 15 342 lbs. 317 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCC-2001W
Water-Cooled
R-404a 208-230/60/1 15 15 342 lbs. 317 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCC-2001R*
AC Remote
R-404a 208-230/60/1 15 15 342 lbs. 317 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
*Use Remote Condenser CR-1200.
Series 200 & Series 525
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
AF200PSCR Air-Cooled R-404a 115/60/1 15 15 220 lbs. 190 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
AF525PSCR Air-Cooled R-404a 115/60/1 20 20 282 lbs. 240 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
AF200PSCR
AF525PSCR
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water
Number Capacity Dimensions Finish Bin Capacity Inlets/Outlets Drainhose
AF200PSCR 219 lbs. 25"w x 26
1
2
"
d x 40"h E or SS 75 lbs.
1
4
"
male flare
5
8
"
O.D. x
1
2
"
O.D.
25 "
40 "
26
1
2
"
38
3
4
"
40 "
26
1
2
"
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 219 lbs. 188 lbs. 175 lbs.
70ºF 208 lbs. 174 lbs. 166 lbs.
90ºF 161 lbs. 130 lbs. 117 lbs.
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 654 lbs. 588 lbs. 552 lbs.
70ºF 639 lbs. 563 lbs. 521 lbs.
90ºF 562 lbs. 479 lbs. 448 lbs.
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Condensate
Number Capacity Dimensions Finish Bin Capacity Inlets/Outlets Drain Bin Drain
AF525PSCR 654 lbs. 38
3
4
"w x 26
1
2
"
d x 40"h E or SS 175 lbs.
3
8
"
male flare
1
2
"
O.D. tube
3
4
"
FPT
WCC2001/B1048SS
32"
48"
30"
76"
28"
F
L A K
E
R
S
12
Series 725
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
AF725PSCR Air-Cooled R-404a 115/60/1 20 20 334 lbs. 300 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
AF725PSCR
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Condensate
Number Capacity Dimensions Finish Bin Capacity Inlets/Outlets Drain Bin Drain
AF725PSCR 654 lbs. 48"w x 30"d x 40"h E or SS 300 lbs.
3
8
"
male flare
1
2
"
O.D. tube
3
4
"
FPT
48 "
40 "
30 "
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 654 lbs. 588 lbs. 552 lbs.
70ºF 639 lbs. 563 lbs. 521 lbs.
90ºF 562 lbs. 479 lbs. 448 lbs.
Series 500
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCF-510A 460 lbs. 14
1
2
"w x 25"d x 24
1
2
"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-510W
460 lbs. 14
1
2
"w x 25"d x 24
1
2
"h
SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCF-510A Air-Cooled R-404a 115/60/1 15 15 154 lbs. 142 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCF-510W
Water-Cooled
R-404a 115/60/1 15 15 154 lbs. 142 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 460 lbs. 412 lbs. 388 lbs.
70ºF 442 lbs. 394 lbs. 371 lbs.
90ºF 407 lbs. 367 lbs. 349 lbs.
Series 700
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCF-710A 936 lbs. 14
1
2
"w x 25"d x 24
1
2
"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-710W
936 lbs. 14
1
2
"w x 25"d x 24
1
2
"h
SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-710R
936 lbs. 14
1
2
"w x 25"d x 24
1
2
"h
SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCF-710A Air-Cooled R-404a 115/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCF-710W
Water-Cooled
R-404a 115/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCF-710R*
AC Remote
R-404a 115/60/1 20 20 138 lbs. 126 lbs. 50°F-100°F 50°F-90°F 20-120 psi 110-126
WCF-710A
Air-Cooled R-404a 208-230/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCF-710W
Water-Cooled
R-404a 208-230/60/1 20 20 163 lbs. 152 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
*Use Remote Condenser WCU.
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 936 lbs. 838 lbs. 789 lbs.
70ºF 892 lbs. 796 lbs. 750 lbs.
90ºF 779 lbs. 701 lbs. 667 lbs.
WCF710/B842SS
32"
42"
14
1
2
"
721⁄2"
241⁄2"
32
5
1
6
"
WCF510/B530SS
30"
14
1
2
"
721⁄2"
241⁄2"
F
L A K
E
R
S
D
I S
P
E
N
S E
R
S
13
Series 2000
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCF-2201A 2506 lbs. 30"w x 24"d x 28"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-2201W 2506 lbs. 30"w x 24"d x 28"h SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-2201R 2506 lbs. 30"w x 24"d x 28"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 2506 lbs. 2244 lbs. 2112 lbs.
70ºF 2280 lbs. 2036 lbs. 1916 lbs.
90ºF 1901 lbs. 1711 lbs. 1628 lbs.
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCF-2201A
Air-Cooled R-404a 208-230/60/1 15 15 342 lbs. 317 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCF-2201W
Water-Cooled
R-404a 208-230/60/1 15 15 342 lbs. 317 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCF-2201R*
AC Remote
R-404a 208-230/60/1 15 15 342 lbs. 317 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
*Use Remote Condenser CR1200.
Series 1000
DIMENSIONS/CAPACITY PLUMBING
Model Nominal Cabinet Water Electrical Service
Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening
WCF-1101A 1559 lbs. 22"w x 24"d x 27"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-1101W 1559 lbs. 22"w x 24"d x 27"h SS
1
4
" MF /
3
8
" FPT
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
WCF-1101R 1559 lbs. 22"w x 24"d x 27"h SS
1
4
" male flare
3
8
" I.D. x
9
16
" O.D.
7
8
" diameter hole
PRODUCTION CHART
AIR-TEMPERATURE WATER-TEMPERATURE
50ºF 70ºF 80ºF
50ºF 1559 lbs. 1396 lbs. 1314 lbs.
70ºF 1426 lbs. 1273 lbs. 1198 lbs.
90ºF 1260 lbs. 1134 lbs. 1079 lbs.
SPECIFICATIONS OPERATING LIMITS
Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water Voltage
Number Condenser Type Electrical Capacity Fuse Size Weight Weight Temperature Temperature Pressure Range
WCF-1101A
Air-Cooled R-404a 208-230/60/1 15 15 210 lbs. 194 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCF-1101W
Water-Cooled
R-404a 208-230/60/1 15 15 210 lbs. 194 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
WCF-1001R*
AC Remote
R-404a 208-230/60/1 15 15 210 lbs. 194 lbs. 50°F-100°F 50°F-90°F 20-120 psi 198-253
*Use Remote Condenser WC1.
DPP-230
DP-230
Nominal Shipping Operating Standard Method of
Model Storage Capacity Dimensions Cabinet Finish Weight Weight Electrical Dispensing
DPP-230
200 lbs.
30"w x 30"d x 59
3
8
"hAll Polyethylene 200 lbs. 170 lbs. 115/60/1 Push Button
161467000
200 lbs.
30"w x 30"d x 59
3
8
"hAll Polyethylene 202 lbs. 172 lbs. 115/60/1
Coin/Token
161467001
200 lbs.
30"w x 30"d x 59
3
8
"hAll Polyethylene 200 lbs. 170 lbs. 115/60/1
Key Operated
161467002
200 lbs.
30"w x 30"d x 59
3
8
"hAll Polyethylene 200 lbs. 170 lbs. 115/60/1 Card Key
Bin Drain: 1" vinyl tube
Drain Connection:
1
2
" FPT
Use with any 22" or 30" “I” Series cube icemaker.
30 "
593⁄8 "
30 "
WCF1101/B1048SS
WCF2201/B1048SS
32"
48"
30"
76"
28"
32"
48"
2
2
"
75"
27"
D
I S
P
E
N
S E
R
S
A C C
E S
S O R
I
E
S
14
Remote Condensers
•Weatherproof housing
•High-efficiency copper and aluminum condenser
•Reduces air conditioning requirements
Cabinet Finish: Galvanized
Cornelius Bagger
•Time-saving
• No mess
• Less melting
• Convenient
• Innovative design Dimensions: 22"w x 10
1
4"d x 28
1
2"h
Shipping weight: 15 lbs.
Model Standard Shipping Operating
Number Refrigerant Electrical Weight Weight Dimensions
CR-500 R-404-A 115/60/1 72 lbs. 68 lbs.
18
1
4
"w x 14"d x 34
1
4
"
h
CR-800 R-404-A 208-230/60/1 100 lbs. 90 lbs.
28
1
2
"w x 14"d x 40
1
8
"
h
CR-1200 R-404-A 208-230/60/1 115 lbs. 105 lbs.
28
1
2
"w x 14"d x 40
1
8
"
h
CR-1400 R-404-A 208-230/60/1 130 lbs. 115 lbs.
28
1
2
"w x 14"d x 40
1
8
"
h
CR-2400 R-404-A 208-230/60/1 124 lbs. 114 lbs.
28
1
2
"w x 15"d x 37
3
4
"
h
WC-1 R-404-A 208-230/60/1 62 lbs. 57 lbs.
21
1
4
"w x 12
1
4
"d x 16
1
2
"
h
WCU R-404-A 115/60/1 128 lbs. 118 lbs.
18
1
4
"w x 25
1
4
"d x 16
1
2
"
h
Model
Number Description
B28 Bagger w/sealing tape dispenser
BG8 1000 Count 81 lb. ice bags
TR2 Sealing tape (single roll)
All Cornelius products meet appropriate agency approval, as listed below.
D-45
ED-200
ED-150/200/250/300
Model Nominal Cup Shipping Operating Standard
Number Model Dimensions Storage Capacity Cabinet Finish Clearance Weight Weight Electrical
ED-150
22"w x 30"d x 35
5
8
"
h
150 lbs. SS cabinet, ABS liner 10" 151 lbs. 135 lbs. 115/60/1
ED-200
30"w x 30"d x 35
5
8
"
h
200 lbs. SS cabinet, ABS liner 10" 197 lbs. 177 lbs. 115/60/1
ED-250
30"w x 30"d x 39
5
8
"
h
250 lbs. SS cabinet, ABS liner 10" 201 lbs. 180 lbs. 115/60/1
ED-300
44
5
8
"w x 30"d x 36
15
16
"
h
300 lbs. SS cabinet, ABS liner 10" 251 lbs. 226 lbs. 115/60/1
Drain Connection:
3
4
"
FPT
Use with Cornelius 330, 530, 630, 830, 1030 and 1230 “I” Series cube icemakers.
COMPATIBLE ICEMAKER "X" SERIES
Model
Number 322 522 330 530 630 830 1030 1230 1444
D45
D100 x x
ED150 x x
ED200 x x
ED250 x x x
ED300 x x x x
16"
28"
22"
D-45
Model Nominal Cup Shipping Operating Standard
Number Model Dimensions Storage Capacity Cabinet Finish Clearance Weight Weight Electrical
D-45
16"w x 22"d x 28"h
45 lbs. SS cabinet, ABS liner 7" 67 lbs. 53 lbs. 115/60/1
Drain Connection:
3
4
" FPT
30 "
355⁄8"
30 "
B
I
N
S
15
• Wide Selection…
Twelve models ranging from 120 to 1315 lbs. storage capacity.
• Corrosion Proof…
All Cornelius storage bins constructed of rotomolded polyethylene or 304 grade stainless steel are virtually corrosion proof. Our standard baked enamel finished bins will provide years of corrosion resistant service.
• Easy Maintenance Bin Liners…All rotomolded
polyethylene bin liners will not crack, chip, dent or rust. Our seamless design with large radius corners allows for easy cleaning and enhances ice removal.
• CFC Free Insulation…
All Cornelius bins are constructed with an average 1
1
⁄2" of rigid CFC free foam insulation, providing superior insulation efficiency.
• Extra Wide Doors…
All Cornelius storage bins are equipped with full­width urethane foam insulated stainless steel doors with chemical resistant gasketing.
• Warranty…All Cornelius
storage bins are covered by our comprehensive product warranty. Contact your local Cornelius agent for warranty details.
Bin Model Dimensions Nominal *Certified
Storage Capacity Storage Capacity Cuber Series Chunklet/Flaker Series Shipping Weight.
WD H 322 330 522 530 630 830 1030 1230 1444 1844 2448 500 700 1000 2000
B122 22" 29" 23
1
2
"* 120 lbs. 90 lbs. x 46 lbs.
B230 30" 29" 23
1
2
"* 200 lbs. 120 lbs. 1 x 1 54 lbs.
B322 22" 31
3
4
"48"* 300 lbs. 260 lbs. x x 1 1 90 lbs.
B430 30" 32
5
16
"38"* 400 lbs. 290 lbs. 1 x 1 x x 1 1 92 lbs.
B530 30" 32
5
16
"48"* 500 lbs. 400 lbs. 1 x 1 x x 1 1 108 lbs.
B842 42" 32" 48" * 800 lbs. 580 lbs. 1 1 1 1 1 1 1 160 lbs.
B1048 48" 32" 48"* 1000 lbs. 670 lbs. 1 1 1 1 1 1 x 1 1 1 1 182 lbs.
1315-SBB 48" 34" 68"* 1315 lbs. 1160 lbs. x x x x x x x 360 lbs.
FR-300SS 26
1
2
" 42" 38
1
4
"** 300 lbs. 260 lbs. xx x 285 lbs.
B122AP B430APB230AP
B530AP
B842SS
B322AP
B1048SS FR-300SS with WCF700
B1315SBB
Rated in accordance with ARI standard 820-88. 1 – Top adapter required
*
– Height dimensions include 6" adjustable legs
**
– Bin supplied with 5" casters
S
P
E
C
I F
I C A
T
I O N
G U
I D
E
16
LOCATION
Always locate the ice machine where ambient temperatures will not fall below 50˚F nor rise above 100˚F.
CLEARANCE
Always make certain the machine and storage bin will fit through all doors and hallways leading to the final installation site.
When installed, there must be a 6-inch air clearance on rear, top and right side of Cornelius modular icemakers. Air intake and
discharge areas require a 6-inch clearance on all machines. Keep in mind when selecting the icemaker location that modular
machines may be stacked to increase production capacity as requirements grow.
UTILITY CONNECTIONS
Electrical, water and drain connections must be within 6 feet of machine location. All connections must meet national,
state and local codes.
ELECTRICAL REQUIREMENTS
Separate circuits, fuses and/or breakers are required for each icemaker or dispenser. Wire, fuse and circuit breaker sizes must be
calculated by a qualified electrician, based on the model’s specifications and must meet all national, state and local codes.
PLUMBING REQUIREMENTS
Ice machines must always be connected to the building’s cold water supply. For proper operation, water temperatures must not
exceed 45˚F-90˚F and pressure must be within 20-120 psi. Icemaker drain tubing must be a minimum of 1/ 2" I.D. Bin drain tubing must be
a minimum of 3/4" I.D. Icemaker and bin drains must be vented. Separate drain lines must be used for the icemaker and bin. Water-cooled
condenser drains must not be vented nor connected to icemaker or bin drain lines. All plumbing must meet national, state and local codes.
QUICK SIZING GUIDELINES
To determine the ice usage in a bar or restaurant, count the number of chairs for customers, multiply that number by 3 lbs. of ice
per bar stool and 1.5 lbs. per table seat. This should fulfill the customer’s needs, unless they are offering self-serve beverages or there is
an exceptionally large carry-out business. If the carry-out customer is at least one-third of the in-store business, add 1 lb. of ice for
each carry-out customer. Nursing home and hospital ice needs are calculated in much the same way. It is only necessary to count the
number of beds and refer to the following amounts: Hospitals need 10 lbs. of ice per bed; nursing homes require 6 lbs. of ice per bed.
Be sure to take into consideration other uses such as cafeterias and staff dining rooms, provided these areas do not have their own
icemakers. For churches or other places that use ice only once or twice a week, a small production machine on a large bin may be
adequate and economical to fulfill an occasional need for ice. However, if this is done and two meetings are scheduled one after the
other, the machine may not have time to adequately refill the bin before the start of the second engagement. When calculating total
daily ice usage make certain to include all anticipated ice usage. The final step is to consult the Cornelius specification sheets for the
model selected to determine its production capabilities under the operating conditions at the customer’s place of business.
MECHANICAL REQUIREMENTS FOR INSTALLATION OF
CORNELIUS ICE MACHINES AND STORAGE BINS
Customers
Application Sizing Guide (daily ice use) 100 250 500 1,000 1,500
(figures below include a 20% safety factor)
Restaurant 1.5 lbs. ice per meal sold 180 450 900 1,800 2,700 Cocktail Bar 3.0 lbs. ice per seat 360 900 1,800 3,600 5,400 Water Glass 6 oz. ice per 12 oz. glass 45 113 225 450 675 Salad Bar 35 lbs. of ice per cubic foot — Beverage Only 5 oz. ice per 7-10 oz. cup 38 94 188 375 563 Beverage Only 8 oz. ice per 12-16 oz. cup 60 150 300 600 900 Beverage Only 12 oz. ice per 18-24 oz. cup 90 225 450 900 1,350 Guest Ice 5 lbs. per hotel room 600 1,500 3,000 6,000 9,000 Hotel Catering 1 lb. per person 120 300 600 1,200 1,800 Patient Ice 10 lbs. per patient 1,200 3,000 6,000 12,000 18,000 Cafeteria 1 lb. per person served 120 300 600 1,200 1,800
QUICK REFERENCE SIZING GUIDE BY CUSTOMER VOLUME
S
P
E
C
I F
I C A
T
I O N
G U
I D
E
17
The quick reference sizing guide works well in many cases; however, more and more customers’ ice needs are changing. Today’s
customers use ice for numerous applications such as product cooling, self-serve beverages, product packaging, display and, in
some cases, retail package sales. To meet customer needs, a more detailed calculation of ice usage and storage requirements is
required. Listed below are the formulas and guidelines for use in these calculations.
SIZING ICE MACHINES
SELF-SERVE BEVERAGES OR CARRY-OUT
– You need to know the size and quantity of drinks sold. Refer to the following table.
This table assumes the cups are completely filled with ice.
Cup Size (fl. oz.) Average Beverage (fl. oz.) Average Ice (oz.)
63 3
12 6 6
16 8 8
20 10 10
32 16 16
48 24 24
After establishing the number of different sized cups sold in a busy day and multiplying that number by the quantities
indicated, a fairly accurate estimate can be determined. If the establishment uses an ice-cooled beverage dispenser, iced salad
bar or some other type of display that requires ice, the amounts needed are examined separately under the Product
Display/Packing and Coldplate Cooling sections.
COLDPLATE COOLING
– To calculate the amount of ice consumed cooling the coldplate, choose the appropriate operating condi-
tion and multiply by the “average amount of beverage” in the “average cup size.”
EXAMPLE:
Find the amount of ice “burned” on a coldplate for a system that has the following operating conditions:
1. 80˚F inlet soda/syrup temperature
2. 6 vends/minute
3. 18 fl. oz. average amount of beverage drink
Therefore:
From the table choose row “6” and column “80.”
This gives a constant of 6.8.
6.8 x 18 = 122.4 lbs./ hour
PRODUCT DISPLAY/PACKING
– To size an icemaker to handle product display or packing, it is necessary to determine the
cubic feet of ice needed in 24 hours (length x width x depth). Since the calculations are done using the foot as the standard unit
of measure, the depth must be converted into feet. If the depth is less than 12 inches, divide depth required by 12 to make the
conversion to feet. A cubic foot of ice weighs approximately 35 lbs., so multiply the cubic feet of space to be used for product
display or packing by 35 to determine the ice needs for a 24-hour period.
EXAMPLE:
A supermarket has a fish display case that is 25 feet long and 3 feet deep.
They wish to set the fish in ice to a depth of 6 inches (6 inches = .50 foot).
Ice requirement for 24 hours: 25 ft. x 3 ft. x .5 ft. = 37.5 cu.ft.
37.5 cu. ft. x 35 lbs. = 1,312.5 lbs.
SAMPLE:
A restaurant has 200 table seats with 4 turns per night, 20 stools at the bar and a salad bar that measures 6 ft. x 3 ft. with a required
ice depth of 4 inches.
General ice usage: 20 (bar stools) x 3 lbs. = 60 lbs.
200 (seats) x 4 (turns) x 1.5 lbs. = 1,200 lbs.
Product display: 6 ft. x 3 ft. x .33 ft. = 5.94 cu. ft.
5.94 cu. ft. x 35 lbs. = 207.9 lbs.
Finally, add all ice usage to determine the requirement for a 24-hour period:
1,200 lbs. + 60 lbs. + 207.9 lbs. = 1,467.9 lbs. ice per day
Soda/Syrup Inlet Temperature
Drinks
per min. 50 60 70 80 90 100
20.61.11.7 2.3 2.8 3.4
41.12.33.4 4.5 5.6 6.8
61.73.45.1 6.8 8.5 10.2
82.34.56.8 9.0 11.3 13.5 10 2.6 5.6 8.5 11.3 14.1 16.9 12 3.4 6.8 10.2 13.5 16.9 20.3 14 3.9 7.9 11.8 15.8 19.7 23.7
CALCULATION METHOD FOR SIZING ICE MACHINES AND STORAGE BINS
S
P
E
C
I F
I C A
T
I O N
G U
I D
E
18
The previous sizing methods assume that the icemaker will run continuously 24 hours a day. This total utilization of the icemaker
gives the customer the most cost effective way of producing the required ice. It also requires the bin to be properly sized or the cus-
tomer will run out of ice.
The example below shows how two operations can have very different usage patterns, yet still require the same size icemaker.
Convenience Store
Restaurant
Monday 400 lbs. Closed
Tuesday 400 lbs. 200 lbs.
Wednesday 400 lbs. 200 lbs.
Thursday 400 lbs. 200 lbs.
Friday 400 lbs. 700 lbs.
Saturday 400 lbs. 800 lbs.
Sunday 400 lbs.
700 lbs.
Weekly Total 2,800 lbs. 2,800 lbs.
Using our formula - 2,800 lbs. wkly. usage ÷ 7 days x 1.2 (“safety factor”) = 480 lbs. ice/day
SIZING STORAGE BINS
When ice is used in equal amounts 7 days per week, as in our convenience store example, the storage bin can be sized to
match the production capacity of the icemaker. Each day approximately 500 lbs. will be produced and 500 lbs. will be used.
Some people think that to size the bin they need only match the bin to the highest day’s usage. This will not always work
and often results in a customer running out of ice. If we had used this method for the restaurant example above, we would
have specified an 800 lb. bin. On Friday, the restaurant would have used 700 lbs. of ice, leaving 100 lbs. in the bin. With
Saturday’s production of 500 lbs. we would have only 600 lbs. in the bin — and we would need 800 lbs. — leaving us 200 lbs.
short on Saturday and again on Sunday. The result would be an unhappy customer.
This is the case in our restaurant example. There are three days — Friday, Saturday and Sunday — when the required amount
of ice exceeds the production capacity of the icemaker (these are called “peaks”). In this case, the bin and not the icemaker should
be sized to take care of these “peak” days.
The best way to determine the size bin required is to work backwards from the last “peak” day — in this case Sunday. Take the
amount by which each day’s usage exceeds the 500 lb. daily production of the icemaker.
Sunday usage - 700 lbs. = 200 lbs. over production
Saturday usage - 800 lbs. = 300 lbs. over production
Friday usage - 700 lbs. = 200
lbs. over production
Total = 700 lbs. over production
Add the total (700 lbs.) to the daily production figure (500 lbs.) to get the bin capacity required to meet the restaurant’s
weekend demand for ice. This method tells us we need at least a 1,200 lb. bin.
Once you think you know the size of the bin required, you can check your estimate as follows:
Assuming the bin is empty Sunday evening, 500 lbs. will be produced on Monday with no usage, and another 500 lbs. on Tuesday
for a total of 1,000 lbs. in the bin. Tuesday’s usage of 200 lbs. will lower the bin contents to 800 lbs. but with 500 lbs. of production,
the bin will be full at 1,200 lbs. on Wednesday. The same will be true for Thursday. As we enter the weekend peak period on Friday
we have 1,200 lbs. in the bin from which we will use 700 lbs. This leaves 500 lbs. in the bin, plus 500 lbs. produced in 24 hours for a
total of 1,000 lbs. Saturday’s usage of 800 lbs. reduces the ice available to 200 lbs., plus 500 lbs. of production for a total of 700 lbs. -
exactly the amount needed for Sunday’s usage.
It’s always a good idea to add the same 20% “safety factor” to the bin as we did to the icemaker. This adjusts for the ice voids
and pyramiding that can occur in the bin. In the case of our restaurant, the addition of the “safety factor” means we would look for
a bin with a storage capacity of approximately 1,400 lbs. (1,200 x 1.2 = 1,440). We can see that an icemaker rated at 500 lbs. of daily
product would easily meet the needs of both of the previous examples, provided that the icemaker runs continuously.
S
P
E
C
I F
I C A
T
I O N
G U
I D
E
19
A GENERAL REVIEW OF THE RULES FOR SIZING ICEMAKERS AND BINS
1. Ice needs are seldom uniform; more ice is generally needed in summer than in winter. Understanding the ice usage of the
customer is a must to assure sufficient ice is available to meet peak demands. Remember, water temperature, as well as the
surrounding air temperature, affects the output capacity of icemakers. Determine what these factors will be during the
peak demand periods. Then verify the icemaker and storage bin selection by the preceding method and refer to the
machine’s production chart to determine the expected capacity under these conditions.
2. Determine the size of the icemaker required by dividing the “worst case” week’s total ice usage by seven. Then add in a 20%
“safety factor.”
3. If equal amounts of ice are used each day (including weekends), size the bin to match the ice production.
4. If there are peaks (where a day’s usage exceeds a day’s production), size the bin to store adequate ice to meet the peak
demand(s).
5. Remember that the per pound cost of making ice is about four times the per pound cost of storing ice.
It’s always much less expensive for the customer to meet their “peak” demands by using the storage bin when possible.
6. When sizing the bin, double-check the bin’s true capacity, using the current ARI directory.
7. A final element to take into account is the shape of the bin, the location of the icemaker(s) on the bin, and the size and
location of the icemaker(s’) ice discharge. An ice discharge opening centered on an extremely wide bin will result in much
more pyramiding and, therefore, less storage.
CUBE ICE MACHINES
Model __________ manufactured by IMI Cornelius, rated in accordance with and certified to comply to ARI Standard 810-91,
having a 24-hour production capacity of _________ lbs. at 90˚F air and 70˚F water temperatures. Cubers to be certified to NSF
Standard 12 and display symbol of certifying agency. Ice machines will include, as standard equipment, the following:
• 304-grade stainless steel frame assembly and exterior panels.
• Built-in water strainer and pressure regulating flow control.
• Self-diagnosing solid state microprocessor control system, with programmable flush cycle.
• Thermistor-type sensors for uniform ice-thickness control and condenser fan control.
• Environmentally safe R-404a refrigerant.
• Split-compartment design, isolating critical components of wet environment.
• Non-corrosive ABS evaporator compartment.
•Epoxy encapsulated proximity switch for harvest termination and full bin control.
ICE STORAGE BIN
Model ________ manufactured by IMI Cornelius, rated in accordance with and certified to comply with ARI Standard 820-88, to
have a storage capacity of _______ lbs. Exterior finish of __________, with interior liner of one-piece seamless roto-molded
polyethylene. Ice machine with storage bin will measure ______" wide, _______" deep and ______" high including 6" adjustable
legs. Storage bin to be certified to NSF Standard 12 and display symbol of certifying agency.
HOSPITALITY DISPENSER
Model ___________ dispenser manufactured by IMI Cornelius, for use with series ____________ cube ice machine. Dispenser to
be rated in accordance with and certified to comply with ARI Standard 820-88, having a storage capacity of _____ lbs. Dispenser will
be equipped to be actuated by __________ (push button, key, room card, coin/token) control. Storage bin to be classified to NSF
Standard 12 and display symbol of certifying agency. The dispenser will include, as standard equipment, the following:
• Solid state adjustable portion control.
• Adjustable automatic off-cycle agitation.
• Interior and exterior roto-molded polyethylene construction.
•6-inch adjustable legs.
FLAKE ICE MACHINES
Model ___________ manufactured by IMI Cornelius, having a 24-hour production capacity of ________lbs. at 90˚F air and 70˚F
water temperatures. Flakers to be certified to NSF Standard 12 and display symbol of certifying agency. Flakers will include, as
standard equipment, the following:
• 300 series stainless steel evaporator.
•Top-mounted auger drive mechanism.
•Manual reset auger motor overload control.
CATG 8699 © 2002 IMI Cornelius www.cornelius.com
Loading...