IMI CORNELIUS INC g One Cornelius Place g Anoka, MN 55303-6234
Telephone (800) 238-3600 Facsimile (612) 422-3246
INSTALLATION MANUAL
UNIVERSAL 750 AGITATOR MOTOR (KIT P/N 3610)
1. Open the electrical control box and disconnect the agitator motor electical leads. Unscrew the agitator
motor from the plate and remove.
2. Drop the new agitator motor into the plate with the angle opposite of the ice bank control. Mark the four
mounting holes (A) and using a #29 drill bit, drill the four holes.
3. Apply Heat Sink Compound (included) to the bottom of the bracket at point B and screw down.
4. Connect the electrical leads in the control box.
A
Correct
Operating
Angle
A
B
B
Ice Bank Control relative to
agitator motor angle.
EIMI Cornelius Inc; 1994 August 24, 1994
185211006