MANUAL INSTALLATION CONVERSION KIT
SPIRE 4.1 TO 4.2
SAFETY OVERVIEW
• Read and follow ALL SAFETY INSTRUCTIONS in this manual and any warning/caution labels on the unit (decals, labels or laminated cards).
• Read and understand ALL applicable OSHA (Occupational Safety and Health Administration) safety regula- tions before operating this unit.
SAFETY ALERT SYMBOL
This is the safety alert symbol. When you see this in the manual or on the unit, be alert to the potential of personal injury or damage to the unit.
Types of Alerts
Indicates an immediate hazardous situation which if not avoided WILL result in serious
injury, death or equipment damage.
Indicates a potentially hazardous situation which, if not avoided, COULD result in serious
injury, death, or equipment damage.
Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or
moderate injury or equipment damage.
SAFETY TIPS
Carefully read and follow all safety messages in this manual and safety signs on the unit.
Keep safety signs in good condition and replace missing or damaged items.
Learn how to operate the unit and how to use the controls.
Do not let anyone operate the unit without proper training. This appliance is not intended for use by very young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
Keep your unit in proper working condition and do not allow unauthorized modifications to the unit.
Safety Instructions
Before starting installation, read and understand all safety label and warnings on the machine. Also review and understand all safety instructions in the owners, installation and service manuals.
Failure to comply could result in serious injury, death or damage to the equipment.
Revision Date: June 7, 2019 www.cornelius.com Revision: B
©2019, Cornelius Inc. - 1 - Publication Number: 629097805INS
Manual Installation Conversion Kit 4.1 To 4.2
!
WARNING:
!
WARNING:
CAUTION:
!
CAUTION:
!
QUALIFIED SERVICE PERSONNEL
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.
All wiring and plumbing must conform to national and local codes. Failure to comply could result in serious injury, death or equipment damage.
SAFETY PRECAUTIONS
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment.
Always be sure to keep the area around the unit clean and free of clutter. Failure to keep this area clean may result in injury or equipment damage.
Note the following: This unit is not designed for use in outdoor locations. The appliance must be placed in a horizontal position. The appliance is not suitable for installation in an area where a water jet would be used.
Publication Number: 629097805INS - 2 - ©2019, Cornelius Inc.
Manual Installation Conversion Kit 4.1 To 4.2
!
WARNING
MANUAL INSTALLATION CONVERSION KIT SPIRE 4.1 TO 4.2
INSTALL KIT PART LIST:
PART NUMBER DESCRIPTION QTY
620070411 Ebox cover (pre-assembled with all required labels and
620070273 Door service cover pre-assembled w/ mounting screws
N/A AIO Display assembly (pre-assembled with bezel and
N/A LX3 mounting bracket assembly (pre-assembled w/LX3,
62058545-002 Breaker Circuit 5A
620058733-003 Ferrite Snap- On 240 Ohm
620058733-007 Ferrite Snap- On 225 Ohm
620070445 Flex Antenna Kit
620070523-200 MFV Board Assy
620070550 Bracket 3rd Circuit Breaker
620070556 Cable Clamp
629097805 Installation Instructions
TOOLS REQUIRED:
new wiring diagram)
and labels)
mounting bracket and screws)
terminal block, display on/ off switch and required wiring/ jumpers)
1
1
1
1
1
1
1
2
1
1
2
1
#2 Phillips Screwdriver
Utility Knife or side-cutting pliers
Flat Head Screwdriver
11/32” nut driver or equivalent
INSTALLATION INSTRUCTION:
1. Shut Down unit per proper shutdown procedure
2. Unplug unit from its AC Power source.
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.
All wiring and plumbing must conform to National and Local Codes. Failure to comply could result in serious injury, death or equipment damage.
Description
©2019, Cornelius Inc. - 3 - Publication Number: 629097805INS
Manual Installation Conversion Kit 4.1 To 4.2
3. Locate power cord inside unit next to the valves and add ferrite supplied on the power cord at approximate location shown.
Figure 1
4. Open door and remove translucent door service panel and discard of properly.
Figure 2
Publication Number: 629097805INS - 4 - ©2019, Cornelius Inc.
Manual Installation Conversion Kit 4.1 To 4.2
cove lighting harness
5. Unplug all connections to display, this includes the cove lighting to the LX3 board.
Figure 3
6. Remove ebox cover saving the (2) screws. Discard ebox cover.
7. Unplug all cables/harnesses from MFV board, remove and properly discard MFV board, install new MFV board supplied with the kit and reinstall previously removed cables/harnesses.
8. Remove wire bundle from the (2) most far right wire clips.
Figure 4
9. From the same wire bundle, remove the (2) USB cables that feed the MFV board, USB hub and the (1) antenna cable that
goes to the rear of the unit.
10. Carefully remove/clip off the (2) far most right wire clips from step 8 and discard.
11. Insert circuit breaker into the mounting bracket supplied.
©2019, Cornelius Inc. - 5 - Publication Number: 629097805INS