Cornelius NORDIC B230-AP Installation Instructions Manual

Plastic Storage Bins Adapter Installation Instructions
!
WARNING:
!
WARNING:
!
WARNING:
CAUTION:
!
INSTALLATION INSTRUCTIONS
NORDIC B230-AP PLASTIC BINS
SAFETY
Failure to comply could result in serious injury, death or damage to the equipment.
QUALIFIED SERVICE PERSONNEL
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.
All wiring and plumbing must conform to national and local codes. Failure to comply could result in serious injury, death or equipment damage.
SAFETY PRECAUTIONS
This unit has been specifically designed to provide protection against personal injury. To ensure continued protection observe the following:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
Always be sure to keep area around the unit clean and free of clutter.
Failure to keep this area clean may result in injury or equipment damage.
Revision Date: March 17, 2014 www.cornelius.com Revision: C
© 2007-2014, Cornelius Inc. - 1 - Publication Number: 620204714INS
Plastic Storage Bins Adapter Installation Instructions
GASKET
TOP FRONT
ASSEMBLY
BIN
GASKET
GASKET
ADAPTER
1. Remove the screw at left front and set aside.
2. Set the adapter in place on the left end of the bin and mark the location. Remove the 1/4 x 5/8 gasket under the adapter and clean the surface with rubbing alcohol. Remove protective paper from the tape and set it in place on the adapter, press down firmly, and reinstall the screw.
3. Add two strips of 1/8 x 1/2 gasket on top of the adapter right side.
4. Seal the edges of the adapter with silicone, as shown.
Figure 1.
Publication Number: 620204714INS - 2 - © 2007-2014, Cornelius Inc.