To ensure trouble free operation it is essential that the unit is installed correctly and
sanitised prior to use.
1. The cooler should be sited on a firm level surface, in a well ventilated
position, and at a maximum distance of 2 metres from an electrical supply. To
ensure efficient and reliable operation of the refrigeration system allow75mm
clearance aro und the unit and that there is an un-impeded flow of air to and
from the condenser grilles. Allow for future access to the lid and service
panels.
2. If not already fitted, fit the appropriate electrical plug to the service cord.
Consult local Electrical legislation for correct method of installation.
WARNING – THIS APPLIANCE MUST BE EARTHED
Do not connect the cooler at this point.
3. Remove the filler cap or lid inspection panel (as appropriate) and fill the bath
with cool, clean water until the water flows from the overflow into the drip
tray. Do not use de-ionised water or add any substance to the water. Do not
leave hose pipes unattended whilst filling the water bath – the overflow will
not remove water quickly enough. Once filled with water do not move the
unit.
4. Ensure that all covers and access panels are screwed in place.
5. Ensure that the cooler is electrically safe. The cooler may now be electrically
switched on to allow it to cool whist the rest of the Installation is completed.
The cooler will displace water through the overflow as it forms its ice.
6. Electrically isolate the cooler. Connect the beer inlet line and check for leaks
before completing the installation.
7. Sanitise the unit – see User Instructions.
8. Electrically switch on the unit.
9. The system is now ready for operation but will not give best results until the
ice bank is fully formed.
MAINTENANCE
Maintenance to be carried out by a suitably trained person only. Compliance with
local Bylaws and Codes of Practice must be ensured.
The cooler requires occasional checking and cleaning as follows:-
1. Check that the water level in the tank is up to the overflow. Remove the
inspection/fill cover and observe the water level.
2. Check that the airflow to the cooler is unimpeded and clean the condenser fins.
To clean the fins – electrically isolate the unit and remove the back panel, use
a soft bristle brush to clean the condenser fins of dirt, dust, etc. Take care not
to damage the fins during cleaning.
At regular intervals to be determined by the user and/or owner of the cooler, check for
electrical safety.
If any maintenance/servicing is required, refer to the fault finding chart, wiring
diagram and exploded drawings contained in the product manual and always ensure
that the following are observed:When replacing components always use IMI Cornelius approved spare parts. Failure
to do so will invalidate the coolers warranty.