INSTALLING REPLACEMENT AGITATOR MOTOR
KITS (P/N 569000207 AND P/N 569000208)
ON
IMPORTANT: Only qualified Personnel should install this kit.
Unpack and inspect the kit. Make sure all kit items are present and in good condition.
Table 1. Loose-Shipped Parts
Item
No. Part No. Name Qty.
1 314072000
314150000 2 319828000 Screw, Thread Rolling, Phil Pn Hd; No. 10–24, .375 Long 3 3 560001745 Mounting Template 1 4 000268010 Drill Bit, 5/32 1
Agitator Motor Ass’y, 115 VAC (Kit P/N 569000207) Agitator Motor Ass’y, 230 VAC (Kit P/N 569000208)
REMOVING OLD AGITAT OR MOTOR ASSEMBLY
WARNING: Disconnect electrical power from the Unit to prevent personal injury before attempting any internal maintenance. Only qualified personnel should service the internal components or electrical wiring.
1. Disconnect electrical power from the Dispenser.
2. Remove hood from Dispenser, then remove cover from electrical control box (see Figure 1).
3. Disconnect old agitator motor assembly electrical wires from L1 and L2 terminals on the PC board (see Figures 1 and 4) inside the electrical control box.
4. Remove old agitator motor assembly from refrigeration deck. Discard old motor and it’s mounting screws.
INSTALLING NEW AGITATOR MOTOR ASSEMBLY
1 1
1. Cut out “AGIT PORT CUT-OUT” area of the MOUNTING TEMPLATE (item 3) with a scissors as shown in Figure 2. Remove adhesive covering from back side of the mounting template, then place template (align template holes with existing agitator motor mounting holes) over the existing agitator motor cut-out in the refrigeration deck.
2. Temporarily install the electrical control box cover to protect the PC boards from metal shavings while drilling. Center punch two hole locations indicated on the mounting template, then using DRILL BIT (item 4) drill indicated holes in the refrigeration deck.
EIMI Cornelius Inc; 1997
May 20, 1997
560001744
3. Remove electrical control box cover. Remove mounting template from the refrigeration deck, then install new AGITATOR MOTOR ASSEMBLY (item 1) on the refrigeration deck (see Figure 3) and secure with two SCREWS (item 2).
4. Connect agitator motor assembly electrical wires to L
and L2 terminals on the PC board inside the
1
electrical control box as shown in Figure 4.
5. Install cover on the electrical control box. MAKE SURE AGITATOR MOTOR WIRES ENTERING
THE ELECTRICAL CONTROL BOX ARE NOT PINCHED.
6. Install hood on the Dispenser, then connect electrical power to the Dispenser. Check Dispenser for proper operation.
ELECTRICAL CONTROL
BOX COVER
OLD AGITATOR
MOTOR
P.C.
BOARDS
ITEM 3
AGIT. PORT
CUTOUT
o
FRONT
AGITATOR MO TOR
MOUNTING TEMPLATE
o
MOUNTING TEMPLATE
(ITEM 3)
FIGURE 1.
SLINGER
(DO NOT MOVE)
ITEM 2
MOUNTING TEMPLATE
(ITEM 3)
AGIT. MTR.
AGIT. MTR.
LEADS
JUMPER
RIBBED COMP
A
APPLY TO
REFRIGERATION DECK
FIGURE 2.
COND. AREA
PUMP
B
SERV CORD
REFRIGERATION
DECK
FIGURE 3. FIGURE 4.
2560001744