Corinex CXP-OC600, Office Connect 600 CXP-OC600 Quick Start Manual

Page 1
Office Connect 600
CXP-OC600
Quick Start Guide
B as i c I n s t al l a t i on P r o c e d ur e
CXZ-CXP-PH12
F o r U p t o 2 0 u s e r s o n a s i n g l e e l e c t r i c a l p h a s e *
U n pa c k C ar t o n C o n te n ts
RJ45 Ethernet cables
Powerline signal coupling cable
MDU Gateway power cord
C o nn e ct th e M D U G at e wa y
Connect other AV200 Powerline Adapters
1. Install 3 USB cables into the MDU Gateway.
2. Connect the MDU Gateway power cord to the MDU Gateway and to an electrical outlet.
3. Connect the RJ45 Ethernet cable to an Internet router and to the MDU Gateway.
4. Connect the Powerline signal coupling cable to the MDU Gateway module 1 (or any of the modules, but only one) and to an electrical outlet.
5. Turn On the MDU Gateway
1. Carefully unpack all of the components from the carton.
2. The package contents should include:
8. Repeat step 6 and 7 above for up to 9 other computers.
The computer will automatically obtain an IP address from the router. Open a web browser. If the Internet is not available, or if an enhanced configuration is required, proceed to step 9.
RF splitter
1
2
3
4
USB cable
Powerline signal loop cable
1 m coax cable
Connect the AV200 Powerline Adapters
6. Connect the power cable to an electrical outlet and to the AV200 Powerline Ethernet Adapter.
7. Connect the RJ45 Ethernet cable to the AV200 Powerline Ethernet Adapter and to a computer.
2
1
MDU Gateway
CXP-MDU-GWY
AV200 Powerline Ethernet Adapter - Enterprise
CXP-AV200-ETHe
Powerline to Coax coupler
CXZ-CXP-CXC
Powerline signal coupling cable B
10. 1 0. 1 . 1 Mod u le 1
9. Connect your PC directly to the MDU Gateway or to a router/switch that is connected to the MDU Gateway
10. Set the IP address of your computer statically via the following procedure:
a) From the Start menu open the Control Panel. b) Open Network Connections and right click on Local Area Connec-
tion and select Properties. c) Select Internet protocol (TCP/IP) (make sure you don't remove the
check mark accidentally) and press the Properties button. d) Select Use the following IP address and enter 10.10.1. 225 set
Subnet mask to 255.255.255.0 then press OK.
11. Open a telnet session and check the connection via the following procedure:
a) Insert the Corinex CD and double click on Corinex Telnet to open up a telnet session
b) When the program starts press OK to connect to the first module of the MDU Gateway. By default the IP address of the first module is
10.10.1.1
c) After the telnet session starts you can type “i” to get information about the MDU Gateway unit, and the AV200 Powerline Ethernet Adapt­ers. Make sure the number of adapters that you have connected match this list. After an adapter is rebooted it takes up to 1 minute for it to connect to the MDU Gateway.
d) You can also telnet to one of the adapters by typing its IP address. Note that you can also check the transmit and receive speeds of the devices using this method.
For a detailed list of advanced commands and configurations please check the advanced installation procedure or the Enterprise Software Manual.
Op t io n al : Co n fi r m y our Co nn e c t io n
d
b
c
d
Basic
Installation
Advanced
Installation
Inductive coupler
11+1 coupler
* For greater than 20 users or for utilizing more than one module on the MDU Gateway, please see the Corinex Professional MDU Networking Installation and User Manual
Page 2
Ad va nc ed In stallation P ro ced ur e
U n pa c k C ar t o n C o n ten t s a ) Pow e rl in e to Coa x co u pl i ng
b ) In d uc t i ve c o up l in g
C o n n ec t th e M D U G at e way
1. Install 3 USB cables into the MDU Gateway.
2. Connect the MDU Gateway power cord to the MDU Gateway and to an electrical outlet.
3. Connect the RJ45 Ethernet cable to an Internet router and to the MDU Gateway.
4. Ensure each electrical phase is connected to an electrical outlet near the MDU Gateway. If the outlets are not available, an electrician must install them. There are 3 methods for MDU Gateway signal coupling, use only one of these methods:
a) Powerline to Coax coupling b) Inductive coupling c) Capacitive coupling
1. Connect the 1m coax cable to module 1 (or any of the modules, but only one) of the MDU Gateway, connect to the RF splitter input.
2. Connect the 3 other 1m coax cables to the 3 outputs of the RF splitter.
3. Connect the 3 Powerline to Coax couplers to the 3 coax cables.
4. Connect 3 Powerline signal coupling cables to the 3 Powerline to Coax Couplers.
5. Connect each of the 3 powerline signal coupling cables to each electrical phase (1 outlet for each phase).
6. Continue with the Basic Installation Procedure from step number 6.
1. Connect the Powerline signal coupling cable B to the MDU Gateway module 1 (or any of the modules, but only one) power outlet.
2. Connect each of the 3 powerline signal loop cables to each electri­cal phase (1 outlet for each phase).
3. Continue with the Basic Installation Procedure from step number 6.
1. Connect the 1m coax cable to module 1 (or any of the modules, but only one) of the MDU Gateway, connect to the 11+1 Coupler input.
2. Connect 3 Powerline signal coupling cables to the 11+1 Coupler.
3. Connect each of the 3 powerline signal coupling cables to each electrical phase (1 outlet for each phase).
4. Continue with the Basic Installation Procedure from step number 6.
c ) Ca p ac i ti v e c o u pl i ng
1
2
3
MDU Gateway
Breaker Panel
Electric Outlet
10.10 . 1 .1 Modu le 1
2
3
3
3
1
4
4
4
5
5
5
( 3- Pha se Pow er)
Breaker Panel
Electric Outlet
Breaker Panel
Electric Outlet
MDU Gateway
10.10 . 1 .1 Modu le 1
1
2
2
2
MDU Gateway
1
2
2
2
3
3
3
(1) MDU Gateway (10) AV200 Powerline Ethernet Adapters (3) USB cables (1) MDU Gateway power cord (11) RJ45 Ethernet cables (3) Powerline signal coupling cables (3) Powerline to Coax couplers (1) 11+1 coupler (1) Powerline signal coupling cable B (3) Powerline signal loop cables (4) 1m coax cables (6) Inductive couplers (1) RF splitter
RJ45 Ethernet cables
Powerline signal coupling cable
MDU Gateway power cord
1. Carefully unpack all of the components from the carton.
2. The package contents should include:
RF splitter
USB cable
Powerline signal loop cable
1 m coax cable
MDU Gateway
CXP-MDU-GWY
AV200 Powerline Ethernet Adapter
CXP-AV200-ETHe
Powerline to Coax coupler
CXZ-CXP-CXC
Powerline signal coupling cable B
Inductive coupler
11+1 coupler
4
CXZ-CXP-PH12
Breaker Panel
Electric Outlet
Note: The electrician may connect the powerline signal coupling cables directly to the breaker panel to avoid installing the 3 electrical outlets.
Basic
Installation
Advanced
Installation
Office Connect 600
Quick Start Guide
CXP-OC600
F o r u p t o 2 0 u s e r s o n m u l t i p l e e l e c t r i c a l p h a s e s *
* For greater than 20 users or for utilizing more than one module on the MDU Gateway please see the Corinex Professional MDU Networking Installation and User Manual
Loading...