mount fixtures vertically.
i2 Suspended Luminaire
CONNECTION AT FIXTURE
Installation Instructions
Warning
meet local/national codes and be performed by a certified electrician.
: Before starting any work ensure that all sources of power are turned off. All work must
Sheet 1 of 2
Do not
ADJUSTABLE CABLE
End Bracket
Adjustable Cable
Assembly
(Side View)
5/8"-7/8" KNOCKOUT
KnockoutsKnockouts
POWER DROPS
Slide adjuster clip into slot on end bracket. Secure
machine screw to adjuster through the holes in the clip,
tighten screw, but leave enough of a gap in the clip
to slide back and forth. Slide cable though adjuster.
Repeat on the opposite end for 1st fixture of row or
stand-alone fixtures. For multiple fixtures, level 1st fixture,
hang 2nd and level, etc. Level the complete row prior
to tightening all the screws.
LAMP INSTALLATION
NOTE: Ensure lamps are properly seated before initial
power-up. Push lamp down into socket and turn 90
degrees.
Break off appropriate KO, slide power cord through KO
opening, then secure power cord with strain relief.
MOUNT SPACING
FIXTURE LENGTH SPACING
48"
4' ROW
28' ROW
NOTE: For continuous rows see next page.
144"
96"
ADE090321 REV B
96"
*Not all options available. Please consult your Cooper Lighting Solutions Representative for availability. Specifications and Dimensi ons
subject to change without notice.

i2 Suspended Luminaire
JOINING
Installation Instructions
Warning
meet local/national codes and be performed by a certified electrician.
: Before starting any work ensure that all sources of power are turned off. All work must
Do not
mount fixtures vertically.
Sheet 2 of 2
Fixture 2
Fixture 2
Fixture 1
Install first fixture with two AC cables,
then second fixture with one
dditional cable.
Bend out tapered aligning tabs and
fit into aligner slots. (Fixture 2 is now
supported by Fixture 1 at the joint.)a
Make electrical connections.
DUST COVER (ABOVE LAMP) E
TM
Fixture 1
Tuck wires into wire cavity, slide both fixtures
together and secure tightly using two 10-32 x
3
/8" screws, starwashers and nuts. Tighten
1/4 turn past hand-tight. Starwashers must
break the paint for proper grounding to occur.
ND CAPSSLIDE-N-LOCK
Remove film from dust cover.
Squeeze dust cover into fixture.
OTE: Power cord and cables will
N
slide through end of dust cover.
Remove film from optic before installing.
To install - set in place over lamps.
The Slide-N-Lock comes preset from the
TM
factory to the customer specified optical
Align End Caps with end bracket of fixture.
Secure using two 10-32 x 3/8" self-tapping
screws .
setting. To adjust, depress the control
notch and slide tab to desired setting.
ADE090321 REV B
*Not all options available. Please consult your Cooper Lighting Solutions Representative for availability. Specifications and Dimensi ons
subject to change without notice.