Core TP72013 User Manual

Job: Universal Manual
Size: 150 x 150 mm folded
07/30/2014 -> Final print pdf
ELAN & Niles & SpeakerCraft
Quick Install Guide – TP7
8 pages each - Format: 150 x 300 mm ( Metric !! )
English only
Folding-Method:
150 150 150 150
TP7 – 7” Touch Panel
Quick Install Guide
English
User Interface
Folded size:
300
150 x 150 mm
Open:
600 mm wide x 300 mm high
07/30/2014 - WE
Questions? Juergen 707 - 778 - 5826
P/N 9901341 REV. B 07/2014
No bleed
+
TP7 – 7” Touch Panel
User Interface
Quick Install Guide
9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 1-4 7/30/14 9:59 AM
English
802.11 B/G/N WiFi
Powering up the TP7
Setting screen orientation
42
Important Safety Instructions
Once installation is complete, press the Power button located on top of the TP7 and allow the unit to boot up.
- If connected to a wired Ethernet switch the TP7 will aquire a network address via DHCP and automatically connect to the system.
- If the TP7 does not detect a wired Ethernet connection and the WiFi radio has never been confi gured you will be presented with the Network Confi guration Utility interface. To complete the network confi guration please refer to the most current training documentation for your system.
The TP7 is shipped pre-confi gured for landscape orientation.
To change orientation:
– Tap the POWER button 10 times in quick succession – Follow the on-screen instructions to re-orient the screen
Power
1. Read, understand and follow ALL safety and installation instructions included in this manual. Failure to follow the included documentation may damage the product and will void manufacturer’s warranty.
2. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments, in close proximity to heat sources and /or non-recommended locations WILL impede, interfere and/or damage the intended operation of the product
3. Only use attachments and accessories which have been specifi ed for use by the manufacturer.
4. The use of abrasive, liquid or solvent based cleaning fl uids WILL damage the product. Please refer and follow all Product Care instructions included with the product.
5. Product Servicing may ONLY be completed by authorized or certifi ed service centers & personnel. For a complete list of product servicing options, please follow instructions included in the product documentation and /or contact original manufacturer for details.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
TP7 – 7” Touch Panel
User Interface
Quick Install Guide
Removing the TP7
– Using two hands grasp it on each side or the top and bottom and pull straight out from the wall. It will require approx. 10lbs of force to remove it from the bracket.
Mounting Bracket
Top of 2 Gang Box
Dry Wall
TP7 Frame
Mounting Bracket
RESET
53
The recessed RESET button has two functions
– A tap of the button will reset all network confi guration – Press and hold the button for 15 seconds completely restores the factory default settings.
CAUTION:
Neither of these actions can be reversed.
Recessed Reset Switch
LAN + Power over Ethernet
Recessed Reset Switch
Paper Clip
FCC and IC Information:
This Class B digital apparatus complies with Part 15 of the FCC rules and with Canadian ICES-003 and RSS-210.
Operation is subject to the following two conditions:
1. This device may not cause interference and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil numérique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.
Warning: Changes or modifi cations to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC and IC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the exemption from the routine evaluation limits in section 2.5 of RSS 102.
1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters from user and bystanders.
Informations concernant l’exposition aux fréquences radio (RF):
La puissance de sortie émise par l’appareil de sans fi l est inférieure à la limite `exposition aux fréquences radio d’Industry Canada (IC). Utilisez l’appareil de sans fi l de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a également été évalué et démontré conforme aux limites d’exposition aux RF d’IC dans des conditions d’exposition à des appareils mobiles (antennes sont supérieures à 20 cm à partir du corps d’une personne).
Warning: The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102, and users can obtain Canadian information on RF exposure and compliance from the Canadian Representative Product Solutions Group at Tel: (519) 763-4538.
English
Thank you for including the TP7 as part of the user interface strategy for your customer. The TP7 has been designed to provide years of trouble free operation when wired and installed properly. The TP7 has been designed for installation in low humidity indoor environments and should never be installed outdoors or in high humidity areas.
Included in the box
1ea TP7 touch panel
1ea TP7 mounting bracket
4ea Mounting screws
1ea DC power connector
Introduction
To install the TP7 you will also need a standard 2 gang US junction box or low voltage bracket.
Specifi cations
Dimensions Overall 8”w x 5”h
Mounting Depth 1 ¾”
Microphone Dual Digital Beam Forming Far Field Pickup
Speaker 2w integrated
Camera 640 x 480
Display 7”
800 x 480
Network 10/100 Ethernet
Connections
LAN/PoE RJ- 45 Power 2 pin Phoenix USB USB Type A Audio Out 1/8” stereo (Future Use)
Power Requirements
Direct – 12v DC 350mA PoE – IEEE 802.3at, 13w maximum draw (@44 V / 350 mA max)
© 2014 Core Brands, LLC. All rights reserved. Core Brands,LLC,aNortek company.
9901341_Rev-B_Universal_TP7_QSG_0730_PRINT.indd 5-8 7/30/14 9:59 AM
P/N 9901341 Rev. B 07/2014
Loading...
+ 1 hidden pages