1. Core Insight Introduction
2. Ionization Technology
A. Steady State DC Ionization B. AC Ionization C. Bipolar Pulsed AC Ionization D. High Frequency AC Ionization
E. Pulsed DC Ionization
3. Application Guide
A. Basic ESD Control B. Ionization for CDM/CBE Controls
4. Cautions and Personal Safety
A. Cautions B. Personal Safety
5. Setup and Operation
A. Contents in the box B. Installation C. Turning on the ionizer D. Alarm
6. Maintenance
7. Specifications
8. Drawings
9. Warranty and Services
Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
3
1. CORE INSIGHT INTRODUCTION
Core Insight is an ionization system manufacturer and supplier to
ESD and contamination control areas. Core also provide general ESD
Test & Measurement, Professional Audit Kits, EMI Noise Filter and
Device Testing Equipment for HBM, TLP, VF TLP and CDM. Technical
services are ESD Training, Process Assessment, ESD Control Program,
Product Qualification Testing per ANSI/ESD Standards, Device Testing
and System Level ESD Testing per IEC 61000-4-2.
Core Insight is major ESD distribution supplier in the field of
semiconductor, flat panel display, automotive and electronic
manufacturing working environment. Core founded in 2003 and
represent for Prostat, On-Filter, Monroe Electronics, Electro-Tech
Systems, Grund Technical Solutions, Lucas Signatone, iT2, SH&A,
Dangelmayer Associate etc.
Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
4
2. Ionization Technology
Core Insight’s CoreStat® Auto-Balanced Ionization System is exact
same technology of SIMCO-ION (previously as known Ion Systems)
which is their exclusive patents has been expired since 2009 and it
has open for everybody. CoreStat® is a steady-state DC ionization
technology with isolated high voltage section of power supply and
maintain intrinsically balanced its offset voltage performance in
specification ranges. All of Model 300 series and Model 3000 series
ionizers are CoreStat® steady-state DC technology which aren’t need
adjust ion output for balance performance. It just need periodic
cleaning emitter points for maintain decay performance.
Core Insight also offer traditional AC ionization technology for
industrial applications such as roll to roll, winding & unwinding of
films for static related contamination issues.
Core offer bipolar Pulsed AC ionizers which is lower frequency than
conventional AC and output parameters are adjustable for each
application such as FPD’s manufacturing environment and others.
High Frequency AC is alternative solution for replacement of
conventional AC for ESD control application and very small package
ionization products. This technology applied lower high voltage level
than conventional AC ionizers, but much faster switching time from
Copyright by CORE INSIGHT, INC. This user manual contents may change without pre-notification.
5
16kHz to 70kHz. This can achieve low offset voltage from ionizers
and can be use ESD control application areas.
Pulsed DC ionization technology is the strength of Core Insight’s
ionization products for cleanroom particle contamination controls.
There are many forms and configuration in this type of products
which improves particle contamination issues in many places such as
semiconductor front-end, back-end, flat panel display fab and many
other industrial applications.
Core Insight offer several types of Charge Plate Monitor (CPM) or
Test Kits for ionizer performance testing of qualification and
compliance verification. Monroe Electronics’ Model 288 is the latest
version of CPM and highly accurate measurement equipment based
on the original voltage following technology. Model 300 is cost
effective ionizer measurement CPM equipment. Both two CPMs can
remotely control and make measurement by software for detail
analysis and test result reporting. These two equipments are perfectly
compliance to ANSI/ESD STM3.1 standard requirement test.
Also, there are hand-held fieldmeter based test kit which is smaller
plater, external charging source and integrated decay timer for
compliance verification measurement per ANSI/ESD SP3.3 test
requirement.