Corbin Russwin Access 700 CL33700 TCPWI1 Series, CL33700TCPIP1, Access 700 CL33700 TCPIP1 Series Installation Instructions Manual

700
TCPWI1/TCPIP1
Installation Instructions CL33700 TCPWI1 & TCPIP1Series
Cylindrical Lockset
Attention Installer
Please read these instructions carefully to prevent missing important steps.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
FM323 3/14
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
CL33700 PWI/PIP Series Cylindrical Lock
Table of Contents
1) Warning ................................................................................2
2) General Description .............................................................3
3) Specifications / Features ....................................................3
4) Product Illustration .............................................................4
5) Installation Instructions ......................................................5
6) TCPIP (PoE) Wiring Instructions........................................17
7) Operational Check .............................................................21
1) Warning
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera­tion.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced technician for help
The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met. This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the fol­lowing two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.
To comply with “Fire Listed” doors, the batteries must be replaced with alkaline batteries only.
!
To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:
!
• Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches, and mounting plates especially when mounting electronic components such as readers and controllers onto the door.
• Leave components (reader and controller) protected in their respective anti-static bags until ready for installation
• Do not touch pins, leads or solder connections on the circuit boards
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
2
CL33700 PWI/PIP Series Cylindrical Lock
2) General Description
Designed specifically for the campus market, the Corbin Russwin Access 700 series mortise Locks are available in WiFi (PWI) and PoE (PIP) configurations. Coupled with third party software the PWI and PIP offers a complete, integrated access control system. The Access 700 may be used for both indoor and outdoor applications (weath­er-protective gasket supplied).
The Access 700 PWI operates on six (6) “AA” alkaline batteries and may be used for both indoor and outdoor ap­plications. A weather-protective gasket is provided for outdoor applications.
3) Specifications / Features
Hardware Specifications
• Latch – Stainless steel, ½” (13mm) throw Optional: ¾” (19mm) throw deadlocking fire latch for pairs of doors
• Deadlocking latch prevents manipulation when door closed
• Door Thickness – 1-3/4” (44mm) to 2” (50mm) Standard Optional 2” (50mm) to 2-1/4” (57mm) optional
• Outside lever controlled by keypad/magstripe card, or key retracts latch
• Inside lever retracts latch
• BHMA Grade 1, UL Fire Listed*
Electrical Specifications:
• HID® multiCLASS SE™ technology offers support for the following credentials:
High Frequency (13.56 MHz):
HID iCLASS
HID iCLASS SE® (SIO-enabled)
HID iCLASS® Seos
HID MIFARE® SE
HID DESfire® EV1 SE
MIFARE Classic
DESfire EV1
FeliCa
Low Frequency (125 kHz):
HID Prox
Magnetic Stripe
NFC-enabled Mobile Phones
®
®
*Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin, Inc. makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
3
CL33700 PWI/PIP Series Cylindrical Lock
4) Product Illustration
5
4
1
2
3
ITEM No. PART No. DESCRIPTION
1 784F565 FIN Outside Escutcheon Assembly, Mag Swipe
784F575 FIN Outside Escutcheon Assemby, Mag Swipe and Keypad
784585 FIN Outside Escutcheon Assemby, Mag Swipe, Keypad, HID 125kHz Prox, and 13.56 MHz Prox
784595 FIN Outside Escutcheon Assemby, Mag Swipe, HID 125kHz Prox, and 13.56 MHz Prox
784F605 FIN Outside Escutcheon Assemby, Mag Swipe, Keypad, HID 125kHz Prox, and 13.56 MHz Felica
784F615 FIN Outside Escutcheon Assemby, Mag Swipe, HID 125kHz Prox, and 13.56 MHz Felica
2
3
4 782F788 Mounting Plate Assembly
5 784F515 FIN Inside Escutcheon Assembly with Privacy Button
783F519 WiFi Controller Assembly
783F509 PoE Controller Assembly
795F368 Screw Pack
6
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
4
CL33700 PWI/PIP Series Cylindrical Lock
4) Product Illustration (Continued)
Tools Required:
• Phillips Screw Driver #2, #3
• Flat Blade Screw Driver (Standard size)
• 1/8” Security Allen Wrench (supplied
• 7/64” Allen Wrench (supplied)
• T20 Security torx driver (supplied)
4
2
3
1
1 783F918 CL33134 Cylindrical lock with fixed core cylinder 1
783F928 CL33134 Cylindrical lock with removable core cylinder 1
2 784F118 Inside Spring Cassette - REX (D134) 1
784F128 Inside Spring Cassette - REX (D214) 1
3 682F268 Outside Spring Cassette (1-3/4” - 2” Door) 1
682F278 Outside Spring Cassette (2” - 2-1/4” Door) 1
4 783F619 DPS (Door Position Switch) Kit 1
For parts not listed, refer to CL3300 Parts and Service Manual
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
5
CL33700 PWI/PIP Series Cylindrical Lock
5) Installation Instructions
1. Verify Hand and Bevel of door:
Illustrations shown are as viewed from the outside or secure side of opening.
Left Hand
Hinges Left.
Open Inward.
“LH”
Left Hand
Reverse Bevel
Hinges Left.
Open Outward
“LHRB”
Right Hand Hinges Right. Open Inward.
“RH”
Right Hand
Reverse Bevel
Hinges Right.
Open Outward
“RHRB”
2. Prep door according to supplied Door Marker (FM302). For door manufacturer templates visit www.corbinrusswin.com and reference Template # T31077.
Inside of Door
Escutcheon Through Bolt Holes
Inside Mouthing Plate Holes
Controller Wire Hole
Wire Run Channel
Escutcheon Through Bolt Holes
Controller Wire Hole
Lockbody Through Bolt Holes
Outside of Door
Door
Position
Switch
Alignment Notches
Lock Body Prep
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
Latch Front
and Hole
Wood Door Preparation
6
Lock Body Through Bolt Holes
Alignment Notches
Lock Body Prep
CL33700 PWI/PIP Series Cylindrical Lock
5) Installation Instructions (Continued)
3. Install Latch Bolt:
Install using two #8 x 3/4” combination screws (Fig. 3).
Note: Make sure the beveled bolt is facing the strike.
4. Install Strike:
Install using two #12 x 1” combination screws (Fig. 4).
Optional Strike Box
Fig. 3
Centerline of Latch Front and Strike
Copyright © 2014 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
Fig. 4
7