Corbett Lighting CBT10216 Installation & Assembly

FIXTURE INSTALLATION
1. Hang the FIXTURE ASSEMBLY (1) to the HOOKS (2) at the ends of the stems on the DISTRIBUTOR (3).
2. Feed the wires & SAFETY CABLE (4) through the STEM (5) and twist tightly onto the DISTRIBUTOR (3). Keep adding additional stems until you desired hanging height is met.
3. Slide in CANOPY(6) onto the STEM (5), and thread the SWIVEL (7) onto the top end of the STEM (5). Then attach the SWIVEL BLOCK (8) above the CANOPY (6) using HEX NUTS (9).
4. Attach the SAFETY CABLE (4) to the building structure or brace using CABLE CLIP (10).
PLATE (9). Adjust the STUDS (13) so that the threads extend
3
16
" below the CANOPY (6) and secure with HEX NUTS (7).
6. Trim off the excess wire to a minimum 6" beyond the STEM and strip each wire
5 8
".
7. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bar copper wire) or the GROUND SCREW (14) on the MOUNTING PLATE (11). NEVER CONNECT GROUND WIRE TO "HOT" WIRE! FAILURE TO
FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
8. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (15). Starting 1" below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS
THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
9. Connect the black fixture leads to the hot (Generally black) wire in the outlet box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN
SERIOUS INJURY OR DEATH!
10. Push the wires back into the junction box. Lift up the CANOPY (6) up to the ceiling, and secure with the MOUNTING NUTS (16)
11. Push the BULB (17) up into the sockets of the fixture.THIS FIXTURE IS RATED FOR
5 WATTS LED TYPE G9
LAMP.
DO NOT EXCEED THE RECOMMENDED WATTAGE!
12. Place the METAL SHADE (18) onto the socket before threading the GLASS DIFFUSER (19) onto place
.
13. Restore power to the outlet at the breaker or fuse box.
EMERALD
333-45
INSTALLATION INSTRUCTIONS
WARNING/CAUTION
· DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS
COMPLETELY BEFORE STARTING INSTALLATION.
· TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
· CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
· REMOVE THE FIXTURE, PARTS AND PARTS BAG(S) FROM THE CARTON. BEFORE DISCARDING THE
CARTON, DOUBLE CHECK TO MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE TO THE FIXTURE.
· DIMMING: THE FIXTURE CAN BE CONTROLLED BY A WALL DIMMING DEVICE. ONLY USE
TRIAC/ELECTRONIC DIMMER. MAKE SURE THE CARTON IS MARKED FOR USE WITH LED COMPACT FLUORESCENT-INCANDESCENT LIGHT SOURCE ONLY. THESE CAN BE PROVIDED BY YOUR LOCAL ELECTRICAL DISTRIBUTOR, HOME CENTER, OR HARDWARE STORE.
· PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS
www.hvlgroup.com
Questions? We're here to help!
Contact us at CustomerService@hvlgroup.com
6
10
4
5
1
7
9 8
15
16
13
11
12
14
3
2
18 17
19
ITEM DESCRIPTION PART NUMBER
1
FIXTURE ASSEMBLY FAS-333-45
2
HOOK HOK-333-32
3
DISTRIBUTOR MIS-333-32
4
SAFETY CABLE CBL-333-32-S
5
3/4" DIA STEM KIT 6"+12"+12"+18"
6
CANOPY CPY-333-32
7
SWIVEL SWL-333-32
8
SWIVEL BLOCK SWL-333-32-B
9
HEX NUT HDW-333-32
10
CABLE CLIP HDW-333-32
11
MOUNTING PLATE HDW-333-32
12
MOUNTING SCREW HDW-333-32
13
STUD HDW-333-32
14
GROUND SCREW HDW-333-32
15
WIRE NUT HDW-333-32
16
MOUNTING NUT HDW-333-32
17
LED G9 BULB BLB-4W-G9-50
18
METAL SHADE SHD-333-01
19
GLASS DIFFUSER GLS-333-01
STM-TC1900-SET
FIXTURE INSTALLATION
1. Hang the FIXTURE ASSEMBLY (1) to the HOOKS (2) at the ends of the stems on the DISTRIBUTOR (3).
2. Feed the wires & SAFETY CABLE (4) through the STEM (5) and twist tightly onto the DISTRIBUTOR (3). Keep adding additional stems until you desired hanging height is met.
3. Slide in CANOPY(6) onto the STEM (5), and thread the SWIVEL (7) onto the top end of the STEM (5). Then attach the SWIVEL BLOCK (8) above the CANOPY (6) using HEX NUTS (9).
4. Attach the SAFETY CABLE (4) to the building structure or brace using CABLE CLIP (10).
MOUNTING SCREWS (12). This fixture is designed to be mounted on standard round or octagon junction box. The
junction box must be securely mounted to the structure of the building. Thread the STUDS (13) unto the MOUNTING
PLATE (9). Adjust the STUDS (13) so that the threads extend
3
16
" below the CANOPY (6) and secure with HEX NUTS (7).
6. Trim off the excess wire to a minimum 6" beyond the STEM and strip each wire
5 8
".
7. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bar copper wire) or the GROUND SCREW (14) on the MOUNTING PLATE (11). NEVER CONNECT GROUND WIRE TO "HOT" WIRE! FAILURE TO
FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
8. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (15). Starting 1" below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS
THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
9. Connect the black fixture leads to the hot (Generally black) wire in the outlet box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN
SERIOUS INJURY OR DEATH!
10. Push the wires back into the junction box. Lift up the CANOPY (6) up to the ceiling, and secure with the MOUNTING
NUTS (16)
11. Push the BULB (17) up into the sockets of the fixture.THIS FIXTURE IS RATED FOR
5 WATTS LED TYPE G9
LAMP.
DO NOT EXCEED THE RECOMMENDED WATTAGE!
12. Place the METAL SHADE (18) onto the socket before threading the GLASS DIFFUSER (19) onto place
.
13. Restore power to the outlet at the breaker or fuse box.
EMERALD
333-45
INSTALLATION INSTRUCTIONS
www.hvlgroup.com
Questions? We're here to help!
Contact us at CustomerService@hvlgroup.com
6
10
4
5
1
7
9 8
15
16
13
11
12
14
3
2
18 17
19
ITEM DESCRIPTION PART NUMBER
1
FIXTURE ASSEMBLY FAS-333-45
2
HOOK HOK-333-32
3
DISTRIBUTOR MIS-333-32
4
SAFETY CABLE CBL-333-32-S
5
3/4" DIA STEM KIT 6"+12"+12"+18"
6
CANOPY CPY-333-32
7
SWIVEL SWL-333-32
8
SWIVEL BLOCK SWL-333-32-B
9
HEX NUT HDW-333-32
10
CABLE CLIP HDW-333-32
11
MOUNTING PLATE HDW-333-32
12
MOUNTING SCREW HDW-333-32
13
STUD HDW-333-32
14
GROUND SCREW HDW-333-32
15
WIRE NUT HDW-333-32
16
MOUNTING NUT HDW-333-32
17
LED G9 BULB BLB-4W-G9-50
18
METAL SHADE SHD-333-01
19
GLASS DIFFUSER GLS-333-01
ATTENTION PRUDENCE
· DÉBRANCHEZ L'ALIMENTATION AVANT DE REMPLIR OU DE CÂBLER LE LUMINAIRE. LISEZ
COMPLÈTEMENT TOUTES LES INSTRUCTIONS AVANT DE COMMENCER L'INSTALLATION
· POUR ÉVITER LE RISQUE D'INCENDIE OU D'ÉLECTROCUTION, LE LUMINAIRE DOIT ÊTRE INSTALLÉ
CONFORMÉMENT À TOUS LES CODES ÉLECTRIQUES/DE CONSTRUCTION NATIONAUX ET LOCAUX APPLICABLES. L'INSTALLATION ET L'ENTRETIEN DE CET APPAREIL DOIVENT ÊTRE EFFECTUÉS PAR UN ÉLECTRICIEN AGRÉÉ OU UN TECHNICIEN CERTIFIÉ FORMÉ EN USINE.
· CALIFORNIE PROP 65 : CET APPAREIL D'ÉCLAIRAGE CONTIENT DES PRODUITS CHIMIQUES CONNUS PAR
L'ÉTAT DE CALIFORNIE POUR PROVOQUER LE CANCER, DES MALADIES CONGÉNITALES ET/OU D'AUTRES DOMMAGES À LA REPRODUCTION. LAVER LES MAINS APRÈS UTILISATION.
· RETIRER LE LUMINAIRE, LES PIÈCES ET LE(S) SAC(S) DE PIÈCES DU CARTON. AVANT DE JETER LE
CARTON, VÉRIFIEZ DOUBLE POUR VOUS ASSURER QUE TOUTES LES PIÈCES SONT TROUVÉES. INSPECTER LE LUMINAIRE AVANT L'INSTALLATION POUR TOUT DOMMAGE AU LUMINAIRE.
· GRADATION : LE LUMINAIRE PEUT ÊTRE CONTRLÉ PAR UN DISPOSITIF DE GRADATION MURALE. UTILISER
UNIQUEMENT UN GRADATEUR TRIAC/ÉLECTRONIQUE. ASSUREZ-VOUS QUE LE CARTON EST MARQUÉ POUR UNE UTILISATION AVEC UNE SOURCE DE LUMIÈRE FLUORESCENTE À INCANDESCENTE COMPACTE UNIQUEMENT. CEUX-CI PEUVENT ÊTRE FOURNIS PAR VOTRE DISTRIBUTEUR ÉLECTRIQUE LOCAL, CENTRE À DOMICILE OU MAGASIN DE QUINCAILLERIE.
· VEUILLEZ NETTOYER UNIQUEMENT AVEC UN CHIFFON DOUX ET SEC ! N'UTILISEZ PAS DE NETTOYANTS
STM-TC1900-SET