OPAL
393-30
INSTALLATION INSTRUCTIONS
WARNING/CAUTION
· DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS
COMPLETELY BEFORE STARTING INSTALLATION.
· TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED
FACTORY TRAINED TECHNICIAN.
· CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH
HANDS AFTER USE.
· REMOVE THE FIXTURE, PARTS AND PARTS BAG(S) FROM THE CARTON. BEFORE DISCARDING THE
CARTON, DOUBLE CHECK TO MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE
PRIOR TO INSTALLATION FOR ANY DAMAGE TO THE FIXTURE.
· DIMMING: THE FIXTURE CAN BE CONTROLLED BY A WALL DIMMING DEVICE. ONLY USE
TRIAC/ELECTRONIC DIMMER. MAKE SURE THE CARTON IS MARKED FOR USE WITH LED COMPACT
FLUORESCENT-INCANDESCENT LIGHT SOURCE ONLY. THESE CAN BE PROVIDED BY YOUR LOCAL
ELECTRICAL DISTRIBUTOR, HOME CENTER, OR HARDWARE STORE.
· PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS
www.hvlgroup.com
Questions? We're here to help!
Contact us at CustomerService@hvlgroup.com
1
15
2
3
5
4
6
7
9
11
10
13
12
14
17
18
16
R
FIXTURE INSTALLATION
1. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is
designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted
to the structure of the building. Thread the NIPPLE (3) onto the MOUNTING PLATE (1). Adjust the NIPPLE (3)
so that the threads extend 1/4" beyond the CANOPY (4). Secure usinng HEX NUT (5).
2. Insert the CABLES (6) on the CABLE GRIPPERS (7) attached on the CANOPY (4). Run the wirings through the
CABLES (6) using WIRE CLIP (8) and insert on the CANOPY (4) hole. To level the the FIXTURE ASSEMBLY
(9) or change the drop height based on your desired height, push the tab down on the CABLE GRIPPER (7)
either pull or push the CABLES (6). Repeat this to all CABLES (6) and wirings until the FIXTURE ASSEMBLY
(9) is leveled and with the desired height.
3. Attach the SAFETY CABLE (10) to the building structure or brace using CABLE CLIP (11).
4. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bare copper wire) or the
GROUND SCREW (12) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT" WIRE!
FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
5. Connect the fixture's SVT neutral (WIRE WITH WHITE STRIP ON IT) wire to the neutral (Generally white) wire
in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (13). Starting 1" below the
fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener.
MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS
SHORT CIRCUIT!
6. Connect the fixture's SVT hot (WIRE WITHOUT ANY STRIPS ON IT) wire to the hot (Generally black) wire in
the outlet box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL
WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
7. Push the wires back into the junction box. Lift the CANOPY (4) up to the MOUNTING PLATE (1) and secure
using THREADED CAP (14).
8. Screw the BULB (15) up into the sockets of the fixture.THIS FIXTURE IS RATED FOR 60 WATTS LAMP. DO
NOT EXCEED THE RECOMMENDED WATTAGE!
9. Install the OVAL GLASS (16) and ROUND GLASS (17) (white side facing lamp and clear side out) onto their
respective places secure THUMB SCREWS (18).
10. Restore power to the outlet at the breaker or fuse box.
8
ITEM DESCRIPTION
PART NUMBER
1
MOUNTING PLATE HDW-393-30
2
MOUNTING SCREWS
HDW-393-30
3
NIPPLE
HDW-393-30
4
CANOPY
HDW-393-30
5
HEX NUT HDW-393-30
6
CABLE CBL-393-30
7
CABLE GRIPPER CBL-393-30-G
8
WIRE CLIP MIS-393-30
9
FIXTURE ASSEMBLY FAS-393-30
10
SAFETY CABLE CBL-393-26-S
11
CABLE CLIP
HDW-393-30
12
GROUND SCREW HDW-393-30
13
WIRE NUT HDW-393-30
14
THREADED CAP
HDW-393-30
15
BULB
NOT INCLUDED
16
SMALL OVAL GLASS GLS-393-02-O-S
17
ROUND GLASS GLS-393-02-R
18
THUMB SCREW SCR-393-02-T