FIXTURE INSTALLATION
1. Slide crimp type cable clamp onto the safety cable. Feed the SAFETY CABLE (13) down through one of the
holes in the top of the outlet box. Loop the SAFETY CABLE (13) over the approved support. Feed the SAFETY
CABLE (13) back through the top of the box and the cable clamp. Using the crimping tool, tightly crimp the
cable clamp to lock the SAFETY CABLE (13) in position.
2. Determine the location for the lamp. Using the MOUNTING PLATE (1) as a template, mark the location of the
holes for the wall WALL ANCHORS(5).
3. Drill the appropriate size holes for the WALL ANCHORS(5). (the holes should be slightly smaller than the size of
the anchors.) Install the WALL ANCHORS(5) to the hole.
4. Attach the MOUNTING PLATE (1) onto the junction box using the MOUNTING SCREWS (2). This fixture is
designed to be mounted on standard junction box. The junction box must be securely mounted to the structure
of the building. Screw in the WOOD SCREW (6) to the WALL ANCHORS(5).
5. Feed the wire through the STEM (11) and twist tightly onto the FIXTURE ASSEMBLY (12). Keep adding
additional stems until you desired hanging height is met.
2. Slide in CANOPY(7) onto the STEM (11), and thread the SWIVEL (8) onto the top end of the STEM (11).
3. Pull the wire out from the junction box, and install the MOUNTING PLATE (1) onto the junction box using the
MOUNTING SCREWS (2).
This fixture is designed to be mounted on standard round or octagon junction box.
The junction box must be securely mounted to the structure of the building.
4. Trim off the excess wire to a minimum 6" beyond the STEM and strip each wire
5
8
".
5. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bar copper wire) or the
GROUND SCREW (3) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT" WIRE!
FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
6. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together
with an approved fastener (WIRE NUT) (4). Starting 1" below the fastener, tightly wrap the connection with
electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED
WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
7. Connect the black fixture leads to the hot (Generally black) wire in the junction box. Fasten the joined wires
same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS
COULD RESULT IN SERIOUS INJURY OR DEATH!
8. Attach the FIXTURE ASSEMBLY (12) to the MOUNTING PLATE (1) and secure it with the HEX NUT (9) and
BOLT NUT (10).
9. Restore power to the outlet at the breaker or fuse box.
BEIRUT
338-06
INSTALLATION INSTRUCTIONS
www.hvlgroup.com
Questions? We're here to help!
Contact us at CustomerService@hvlgroup.com
ITEM DESCRIPTION PART NUMBER
1
MOUNTING PLATE
HDW-338-03
2
MOUNTING SCREW
SCR-338-01-M
3
GROUND SCREW SCR-338-01-G
4
WIRE NUT
NUT-338-01
5
WALL ANCHORS MIS-338-03
6
WOOD SCREW SCR-338-03-W
7
CANOPY CPY-338-03
8
SWIVEL SWL-338-03
9
HEX NUT NUT-338-06-H
10
BOLT NUT
NUT-338-03-B
11
STEM STM-338-03-06,12,18
12
FIXTURE ASSEMBLY FAS-338-06
13
SAFETY CABLE CBL-338-01
1
2
4
7
9
10
11
12
3
5
6
8
13
R
ATTENTION PRUDENCE
· DÉBRANCHEZ L'ALIMENTATION AVANT DE REMPLIR OU DE CÂBLER LE LUMINAIRE. LISEZ
COMPLÈTEMENT TOUTES LES INSTRUCTIONS AVANT DE COMMENCER L'INSTALLATION
· POUR ÉVITER LE RISQUE D'INCENDIE OU D'ÉLECTROCUTION, LE LUMINAIRE DOIT ÊTRE INSTALLÉ
CONFORMÉMENT À TOUS LES CODES ÉLECTRIQUES/DE CONSTRUCTION NATIONAUX ET LOCAUX
APPLICABLES. L'INSTALLATION ET L'ENTRETIEN DE CET APPAREIL DOIVENT ÊTRE EFFECTUÉS PAR UN
ÉLECTRICIEN AGRÉÉ OU UN TECHNICIEN CERTIFIÉ FORMÉ EN USINE.
· CALIFORNIE PROP 65 : CET APPAREIL D'ÉCLAIRAGE CONTIENT DES PRODUITS CHIMIQUES CONNUS PAR
L'ÉTAT DE CALIFORNIE POUR PROVOQUER LE CANCER, DES MALADIES CONGÉNITALES ET/OU D'AUTRES
DOMMAGES À LA REPRODUCTION. LAVER LES MAINS APRÈS UTILISATION.
· RETIRER LE LUMINAIRE, LES PIÈCES ET LE(S) SAC(S) DE PIÈCES DU CARTON. AVANT DE JETER LE
CARTON, VÉRIFIEZ DOUBLE POUR VOUS ASSURER QUE TOUTES LES PIÈCES SONT TROUVÉES.
INSPECTER LE LUMINAIRE AVANT L'INSTALLATION POUR TOUT DOMMAGE AU LUMINAIRE.
· GRADATION : LE LUMINAIRE PEUT ÊTRE CONTRLÉ PAR UN DISPOSITIF DE GRADATION MURALE. UTILISER
UNIQUEMENT UN GRADATEUR TRIAC/ÉLECTRONIQUE. ASSUREZ-VOUS QUE LE CARTON EST MARQUÉ
POUR UNE UTILISATION AVEC UNE SOURCE DE LUMIÈRE FLUORESCENTE À INCANDESCENTE COMPACTE
UNIQUEMENT. CEUX-CI PEUVENT ÊTRE FOURNIS PAR VOTRE DISTRIBUTEUR ÉLECTRIQUE LOCAL,
CENTRE À DOMICILE OU MAGASIN DE QUINCAILLERIE.
· VEUILLEZ NETTOYER UNIQUEMENT AVEC UN CHIFFON DOUX ET SEC ! N'UTILISEZ PAS DE NETTOYANTS