MAX
325-09
INSTALLATION INSTRUCTIONS
WARNING/CAUTION
· DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS
COMPLETELY BEFORE STARTING INSTALLATION.
· TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND
MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED
FACTORY TRAINED TECHNICIAN.
· CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH
HANDS AFTER USE.
· REMOVE THE FIXTURE, PARTS AND PARTS BAG(S) FROM THE CARTON. BEFORE DISCARDING THE
CARTON, DOUBLE CHECK TO MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE
PRIOR TO INSTALLATION FOR ANY DAMAGE TO THE FIXTURE.
· DIMMING: THE FIXTURE CAN BE CONTROLLED BY A WALL DIMMING DEVICE. ONLY USE
TRIAC/ELECTRONIC DIMMER. MAKE SURE THE CARTON IS MARKED FOR USE WITH LED COMPACT
FLUORESCENT-INCANDESCENT LIGHT SOURCE ONLY. THESE CAN BE PROVIDED BY YOUR LOCAL
ELECTRICAL DISTRIBUTOR, HOME CENTER, OR HARDWARE STORE.
· PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS
www.hvlgroup.com
Questions? We're here to help!
Contact us at CustomerService@hvlgroup.com
FIXTURE INSTALLATION
1. Attach the MOUNTING PLATE (1) unto the junction box using the MOUNTING SCREWS (2). This fixture is
designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted
to the structure of the building. Thread the STUDS (3) onto the MOUNTING PLATE (1) and adjust its threads so
that 3/16" of threads extends beyond the FIXTURE ASSEMBLY (4), secure using HEX NUTS (5).
2. Unthread the RING (6) from the socket at the center of the FIXTURE ASSEMBLY (4) using the SPECIAL TOOL
(7) provided, then remove its METAL FRAME (8). Attach the FIXTURE ASSEMBLY (4) to the MOUNTING
PLATE (1) and secure using BALL NUTS (9).
3. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bare copper wire) or the
GROUND SCREW (10) on the MOUNTING PLATE (1). NEVER CONNECT GROUND WIRE TO "HOT" WIRE!
FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
4. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together
with an approved fastener (WIRE NUT) (11). Starting 1" below the fastener, tightly wrap the connection with
electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED
WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
5. Connect the black fixture leads to the hot (Generally black) wire in the junction box. Fasten the joined wires
same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS
COULD RESULT IN SERIOUS INJURY OR DEATH!
6. Attach the SPLICE ACCESS COVER (12) to the FIXTURE ASSEMBLY (4) using SPLICE ACCESS SCREWS
(13). Then return the METAL FRAME (8) unto place and thread the RING (6) unto the socket using the
SPECIAL TOOL (7).
7. Screw the BULB (14) up into the socket of the fixture.THIS FIXTURE IS RATED FOR 6 WATTS LAMP. DO
NOT EXCEED THE RECOMMENDED WATTAGE!
8. Restore power to the outlet at the breaker or fuse box.
1
7
8
7
R
2
7
5
3
4
6
9
10
11
12
13
14
ITEM DESCRIPTION
PART NUMBER
1
MOUNTING PLATE
HDW-325-09
2
MOUNTING SCREW SCR-325-01-M
3
STUD STD-325-01
4
FIXTURE ASSEMBLY FAS-325-09
5
HEX NUT NUT-325-01-H
6
RING RNG-325-01
7
SPECIAL TOOL MIS-325-01
8
METAL FRAME HRD-325-01
9
BALL NUT BLL-325-09
10
GROUND SCREW SCR-325-01-G
11
WIRE NUT NUT-325-01
12
SPLICE ACCESS COVER MIS-325-09-C
13
SPLICE ACCESS SCREW MIS-325-09-S
14
BULB
NOT INCLUDED