6
Gas category
Note: when injectors are changed, the new one should be marked by the gas technician.
Appliance Class: 3
This appliance complies with the following E.E.C. Directives: 2006/95, 93/68, 2004/108 and 90/396.
Important safety requirements
Provision for ventilation
The hob should not be installed in a bed sitti ng room with a volume of less than 20m³. If it is installed in a room of volume less than 5m³
an air vent of effective area of 110cm²is required. If it is installed in a room of volume between 5m³and 10m³, an air vent of effective
area of 50cm² is required, while if the volume exceeds 11m³no air vent is required. However, if the room has a door which opens
directly to the outside no air vent is require d even if the volume is between 5m³
and 11m³3. If there are other fuels burning appliances in
the same room, which should be consulted to determine the requisite air vent requi rements.
Location
The hob may be located in a kitchen, a kitche n/diner or bed sitting room, but not in a bathroom, shower room or garage.
Before making the cut out in the worktop ensures that there is a minimum distance of 55 mm between the rear edge of the hob and the
wall.
A minimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls.
The minimum distance combustible materia l can be fitted above the hob in line with the edges of the hob is 400 mm.
If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob.
The minimum distance combustible material can be fitted directly above the hob is 700 mm. (See Figure 4*)
Warning: The use of a gas cooking appliance results in the production of heat and m oisture in the room in which it is installed. Ensure that
the kitchen is well ventilated: keep natural ve ntilation holes open or install a mechanical ventila tion device.
0845-14
I
3B/P(30)
LU,NL,DK,FI,SE,CY,CZ,EE,LT,MT,SK,SI,BG,IS,NO,TR,HR,HU,RO,IT,LV
I
3+(28-30/37)
BE,FR,IT,LU.IE,GB,GR,PT,ES,CY,CZ,LT,SK,CH,SI,LV
I
3B/P(37)
PL
I
3B/P(50)
DE,AT,CH,LU,SK
FR,IT,BE,NL,DK,IE,GB,GR,ES,PT,AT,FI,SE,CZ,EE,HU,LV,LT,SK,SI,IS,NO,CH,TR,BG,HR,RO
I
2H(20)
I
2E(20)
DE,LU,PL
I
2E+
BE,FR
I
2L(25)
NL
II
2E3B/P
DE,PL,RO
II
2H3+
CH,CY,CZ,GB,GR,IE,IT,LT,PT,SI,SK
II
2H3B/P
AT,CH,CY,CZ,DK,EE,FI,GR,IT,LT,NO,RO,SE,SK,SI
Gas category I2H(13)
I2H(20)/I2E
(20)/I2E+
I2L(25)
I3B/P(30)/I
3+
I3B/P(37) I3B/P(50)
Wok burner
/ 1.3 1.36
3.3
(0.317m3/h)
0.93 0.88 0.76
Wok burner (midea)
/ 1.3 1.36
3.3
(0.317m3/h)
0.88 0.88 0.8
Rapid burner
/ 1.3 1.25
3.0
(0.288m3/h)
0.85 0.84 0.75
Semi rapid burner
/ 0.97 0.95
1.75
(0.168m3/h)
0.65 0.63 0.58
Auxiliary burner
/ 0.72 0.7
1.0
(0.096m3/h)
0.5 0.49 0.43
3.3
(240.9g/h)
3.3
(240.9g/h)
3.0
(219.0g/h)
1.75
(127.8g/h)
1.0
(73.0g/h)
NG(G20) LPG(G30)
Injector Dia.(mm) Injector Dia.(mm)
kw kw