Coralife TurboTwist Series, Turbo-Twist 6x, Turbo-Twist 12x, Turbo-Twist 3x Instructions Manual

TURBO
TURBO
-TWIST
TM
UV Sterilizer
TURBO
-TWIST
TM
U V S t e r i l i z e r
-TWIST
TM
12 Month Limited Warranty
WHAT THE WARRANTY COVERS:
Central Aquatics (Company) warrants this product (see Exclusions below) to the original purchaser against defective material and workmanship that occurs during normal use for 12 months from the date of original purchase. Company will, at Company’s option, either repair or replace product or part without charge (but no cash refunds will be made).
TURBO
UV Sterilizer
-TWIST
TM
EXCLUSIONS:
1. Damage resulting from accident, misuse, abuse, lack of reasonable care, subjecting the product to any but the specifi ed electrical service, other than normal and ordinary use of the product, subjecting the product to abnormal working conditions or any other failure not resulting from defects in materials or workmanship.
2. Damage resulting from modifi cation, tampering with or attempted repair by anyone other than the Company.
3. Transfer of product to someone other than the original consumer purchaser.
4. UVC lamp is not covered under warranty.
WHAT YOU MUST DO TO ENFORCE WARRANTY:
1. Contact the Company by mail or telephone to obtain support under warranty: Central Aquatics, 5401 West Oakwood Park Drive, Franklin, WI 53132; E-mail:
info@central-aquatics.com; Tel: 800-255-4527; Fax: 414-421-3530
2. Deliver, mail or ship the product, together with a copy of the original bill of sale, to: Central Aquatics 5401 West Oakwood Park Drive Franklin, WI 53132 Attn: Tech Dept.
You must pay any postage, shipping charges, insurance costs and other expenses to return the product to Central Aquatics, Franklin, WI. However, if the necessary repairs are covered by the warranty, Company will pay the return shipping charges to any destination within the United States or Canada.
LIMITATION OF IMPLIED WARRANTIES AND EXCLUSION OF CERTAIN DAMAGES:
THE COMPANY DISCLAIMS LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, WITH RESPECT TO THIS PRODUCT. THIS WRITING CONSTITUTES THE ENTIRE AGREEMENT OF THE PARTIES WITH RESPECT TO THE SUBJECT MATTER HEREOF; NO WAIVER OR AMENDMENT SHALL BE VALID UNLESS IN WRITING SIGNED BY THE COMPANY. Some states do not allow the exclusion or limitation of consequential damages, so the above limitation or exclusion may not apply to you.
Instructions
Please read these instructions in their entirety before attempting to use this product.
EPA Estab. No. 073048-CA-00
Coralife
A product of Central Aquatics
(Division of Central Garden & Pet)
Franklin, WI 53132 800.255.4527
Coralife® is a registered trademark of Central Garden & Pet © 2009 Central Garden & Pet
®
Instructions
PARTS DIAGRAM
PLUG
The Coralife Turbo-Twist Ultraviolet Sterilizers are easy to set up and operate. Please read all instructions in their entirety before installation.
To accommodate your new sterilizer, you will need a power-head, pump, or canister fi lter with an appropriate fl ow rate for the size of your UV Sterilizer to ensure adequate ultraviolet exposure while treating the entire volume of aquarium water with appropriate frequency.
FLAT O-RING
BALLAST
Instructions
THREADED CAP
O-RING
HOSE BARB
ADAPTER
HOSE LOCK NUT
Water pump not included.
SPECIFICATIONS
Article Turbo-Twist 3x Turbo-Twist 6x Turbo-Twist 12x
UVC Lamp 9 watt 18 watt 36 watt
Rated Voltage AC120V AC120V AC120V
Rated Cycle 60Hz 60Hz 60Hz
Rated Power 10.2 watt 19 watt 38 watt
Irradiation of UVC Radiation* 9,580 µW/cm
Wavelength of Radiation 253.7mm 253.7mm 253.7mm
Life of UVC Lamp Approx. 8,000 hrs Approx. 8,000 hrs Approx. 8,000 hrs
Aquarium Volume Up to 125 gals Up to 250 gals Up to 500 gals
Flow Rate (gallons per hour) 100-200 gph 200-400 gph 400-1200 gph
Size of O-ring (mm) 12/16, 16/22 16/22, 22/28 16/22, 16/28
Cord Length Approx. 9 ft Approx. 9 ft Approx. 9 ft
1 2
UVC LAMP
(HOSE BARB OUTLET)
QUARTZ HOUSING
O-RING GASKET
MAIN BODY
LAMP ON INDICATOR
2
11,400 µW/c m
*(value @ 20mm distance from the UVC lamp)
TURBO-TWIST
BRACKET
(HOSE BARB INLET)
2
11,400 µW/c m
TANK
BRACKET
SUCTION
CUP
HOSE LOCK NUT
HOSE BARB
ADAPTER
O-RING
1. Set up and positioning
QUARTZ HOUSING
SAFELOCK O-RING GASKET MAIN BODY
Adjusting the hose barb inlet and outlet
The hose barbs can be positioned in four different locations to facilitate connections to other applications.
QUARTZ SLEEVE
Lift the red safelock and unlock
the quartz housing. (Picture 1)
(PICTURE 1)
Carefully twist the quartz housing
and the main body opposite of each other. (Picture 2)
(PICTURE 2)
The quartz housing can now be
rotated 360
o
. (Picture 3)
Adjust the orientation of the hose
barb and set the main body into
QUARTZ HOUSING
MAIN BODY
the quartz housing.
(PICTURE 3)
Combine the main body with the
quartz housing and rotate
2
according to the arrowhead “close”. (Picture 4)
(PICTURE 4)
Press in the red safelock and the
UV Sterilizer is now ready to install. (Picture 5)
(PICTURE 5)
SAFELOCK
QUARTZ HOUSING
MAIN BODY
SAME AS PICTURE
Bracket Installation
Adjust the tank bracket so that it hangs
on the outside of the aquarium.
RANGE OF THE CLAMP
PULL-OUT PULL-OUT
PLACE ON
AQUARIUM
Snap the main body into the bracket indicated
by a “click”. Snap the other bracket with the suction cup in the same way.
SNAP-IN
For horizontal positioning, take the suction
cup out and snap the main body into the brackets until it locks with a “click”.
Slide the Turbo-Twist bracket onto the tank
bracket. Make sure the Turbo-Twist bracket is securely fastened onto the tank bracket.
TURBO-TWIST
BRACKET
TANK
BRACKET
SNAP-IN
SUCTION CUP
SNAP-IN SNAP-IN
3. Reassembly
Make sure that the fl at O-ring gasket is properly positioned inside the threaded cap (already installed in unit). Screw the threaded cap tightly back into place.
O-RING GASKET
Note: The plug and cord should be turned together when screwing the threaded cap back into place.
4. Attaching the hose lock nuts
Position the hose lock nuts on the
hose-barb inlet and outlet.
HOSE LOCK NUT
Hose barb adapter installation.
Place the O-ring on
hose barb inlet/outlet.
O-RING O-RINGHOSE BARB ADAPTER
Hand tighten the hose
barb adapter onto the Turbo-Twist.
Use fl exible tubing to connect the sterilizer to the water
supply. Turn the hose lock nut counter-clockwise to tighten fl exible tubing onto the hose barb. Hose lock nuts require only hand tightening.
FLEXIBLE
TUBING
Use fl exible tubing to connect the sterilizer
Note: Do not use O-ring when larger hose barbs are being used.
to the water supply. Turn the hose lock nut counter-clockwise to tighten fl exible tubing onto the hose barb.
FLEXIBLE
2. UVC Lamp installation
Remove threaded cap, install UVC lamp into socket until lamp “clicks” into place.
THREADED CAP
UVC LAMP
Note: Water will leak if the O-ring is not in place.
5. Installing the Turbo-Twist
Hang the unit using the
Turbo-Twist bracket and suction cup on the outside of the aquarium. Adjust the
TUBING
Horizontal Positioning
Attach Turbo-Twist bracket with screws on
a fi xed surface.
SMALL HOSE LOCK NUT
tank bracket to secure the Turbo-Twist UV Sterilizer.
AQUARIUM
3 4
6. Water fl ow outlet connection
Maintenance
Connect the tubing
between the water fl ow outlet and the hose barb inlet.
It is recommended that a
prefi lter be used with the Turbo-Twist to limit the amount of debris entering the sterilizer.
WATER FLOW OUTLET
HOSE BARB
INLET
CANISTER
FILTER
Maintenance
To ensure superior performance, the quartz sleeve should be cleaned periodically.
Cleaning the quartz sleeve
Disconnect UV Sterilizer from
outlet, turn off the pump and let water drain from Turbo-Twist.
Warning: Never install a valve directly on the tubing between the main body and the aquarium.
Note: Make sure that the tubing is not carrying the weight of the Turbo-Twist UV Sterilizer. Use the Turbo-Twist brackets to support the unit.
HOSE BARB INLET
WATER FLOW
WATER FLOW
7. Start water fl ow
Turn on water supply to the Turbo-Twist. Once proper water fl ow has been established, tilt the unit and let the air bubbles inside the tubing and the main body escape. Examine the unit and check for any leaks.
8. Power up Turbo-Twist
Connect the Turbo-Twist to the power supply. Verify that the UVC lamp is working properly, indicated by the light blue glow emitted through the lamp-on indicator. The light from the lamp-on indicator will not affect the skin or the eye.
LAMP-ON INDICATOR
C A U T I O N
Lift the red safelock and unlock
the quartz housing. (Picture 1)
Carefully twist the quartz housing
and the main body opposite of each other. (Picture 2)
Slide the quartz sleeve out of the
main body. (Picture 3)
Wipe the quartz sleeve using a soft,
damp cloth. Do not use household cleaners or abrasive scrubbers to clean the quartz housing.
C A U T I O N
SAFELOCK
(PICTURE 1)
QUARTZ HOUSING
(PICTURE 2)
MAIN BODY
SAFELOCK
(PICTURE 3)
QUARTZ SLEEVE
Once clean, reinstall the quartz sleeve
into the main body and push the red safelock into the lock position.
• Never look directly at the unshielded lamp as ultraviolet radiation is harmful.
• Disconnect the UV Sterilizer from the power supply when installing or performing maintenance.
• Never submerse the UV Sterilizer in water.
• Never look directly at the unshielded lamp as ultraviolet radiation is harmful.
• Disconnect the UV Sterilizer from the power supply when installing or performing maintenance.
• Never submerse the UV Sterilizer in water.
5 6
Troubleshooting
UVC Lamp Replacement
W A R N I N G
PROBLEM SOLUTION
UVC Lamp
is not working
Water leak
• The plug is not connected to the power supply.
• UVC lamp base is loose. • Push the UVC lamp onto the
• The lamp has expired. • Replace the UVC lamp.
• The hose lock nut is loose. • Tighten the hose barb or the
• Connect the plug to the power supply.
socket until a “click” is heard.
hose lock nut.
between the
main body and
hose lock nuts
• The O-ring is not in place. • Install the O-ring.
UVC Lamp Replacement
The UVC lamp has a useful life of about 12 months. To ensure effective performance, replace the UVC lamp once per year.
How to replace the UVC lamp
Disconnect the sterilizer from the power supply. (It is also necessary
to disconnect the power to the water pump.)
Please read instructions in their entirety
before using the UV Sterilizer.
Cut off the power and stop using if the UV Sterilizer was submersed or dampened by water.
Cut off the power if there is a burning or smoking smell.
Never look directly at the unshielded lamp as the ultraviolet radiation emitted from the lamp can be harmful.
Cut off the power immediately if water enters into the quartz housing.
Never connect the sterilizer to the power outlet while hands are wet.
Do not pull cord to disconnect power supply.
Remove the threaded cap to
uncover the lamp socket.
SOCKET
Once cool, pull the UVC lamp out
of the socket (Be careful not to touch the lamp as it may be hot).
Make sure that the pins of the lamp plugs
into the socket indicated with a "click".
Reassemble the Turbo-Twist.
Unplug the UVC lamp out of the main body
and allow to cool.
UVC LAMP
UVC LAMP
SOCKET
Always leave a drip loop in the power cord to prevent water from running down the length of the cord and reaching the power outlet.
The water temperature fl owing through the UV Sterilizer should be below 105oF (40oC).
Always disconnect the UV Sterilizer from the power supply before shutting down the fl ow of water to prevent overheating.
Though the Turbo-Twist is water resistant, it should never be intentionally submersed in water. Always install the sterilizer in a location where there is little likelihood of fl ooding or water dripping onto the UV Sterilizer.
Make sure that appropriately-sized hose lock nuts are positioned on hose barbs before attempting to connect tubing.
Only a 120V (60 Hz) electrical source should be used with the Turbo-Twist.
7 8
Suggested Tubing Connections
PUMP
PUMP
PUMP
Coralife Turbo-Twist™ UV Sterilizer Flow Rates
UVC Energy (µw sec/cm2)
45,000
40,000
35,000
30,000
25,000
20,000
15,000
10,000
UVC Energy (µw sec/cm
45,000
40,000
35,000
30,000
25,000
20,000
15,000
10,000
UVC Energy (µw sec/cm
45,000
40,000
35,000
30,000
25,000
20,000
15,000
10,000
55 gph Parasites
2
)
110 gph Parasites
2
)
290 gph Parasites
Turbo-Twist™ 3x
121 gph
Algae
(gallon/hour)
Turbo-Twist™ 6x
240 gph
Algae
(gallon/hour)
Turbo-Twist™ 12x
680 gph
Algae
(gallon/hour)
253 gph Bacteria
500 gph
Bacteria
1550 gph
Bacteria
286264242220198176154132110886644
57252848444039635230826422017613288
176016201480134012001060920780640500360220
9 10
Loading...