The software used to realize the central control for all internet video monitor devices
(including:DVS and IP camera) : monitor, dat a storage, data transfer\manage\control. This
version support 1/4/6/8/9//12/16//20/25/30 display , OSD setting, talkback, record playback,
alarm control and MD, etc. The interface is friendly and easy, can help to control more
than one device in same time. The main functions below:
z Realtime monitor, support CIF/QCIF/Half-D1/D1 format
z Support talkback function
z Support ptz function, allow Pelco D/P and other transparent protocol
z Support alarm /MD/time/ manual trigger record
z Support MD(area/sensitivity optional)/private mask/picture snap
z Support SMTP, send picture to mailbox when alarm
z Support DDNS/PPPoE/DHCP
z Support UPnP,auto configuration port
z Support long distance online upgrade
2 Installation Guide
System requirement
z Operating System: Windows 2000/XP/Vista
z Processor: Intel Pentium III, 1G or Higher (Pentium IV, 2G or Higher
recommended)
z RAM: 256 MB or more
z Color Monitor: At least DirectX 8.1 or higher and 32M Display storage
z HD: More than 40G
Software installation
Run the client software DVS_Client_Setup.exe, the window below will pop up:
Design and specification are subject to change without prior notice
1
Select English, and clickǏOKǐ˖
Click ǏNextǐ, the window below will pop up:
Press ǏBrowse…ǐ to change the default path. If you do not want to change, press
Design and specification are subject to change without prior notice
2
ǏInstallǐ.
The below window will pop up:
Then the setup is completed successfully.
Design and specification are subject to change without prior notice
3
3 Software Instructions
3.1 Main Interface
Run DVS Client software, need input password, default is blank. Please referǏClient
Setupǐ ĺǏlocal user managementǐfor user name and password change. The interface
as below:
For the first login, user need add the IP address/domain name in order to trigger the
monitor screen, the steps are as follows:
ķ Click
on the right side, pop following dialog:
Design and specification are subject to change without prior notice
4
Mark1: If device not in same network segment, the software can search the IP
address but can’t link. Please change device and pc in same segment.
Mark2: Default IP is 192.168.0.233, gateway is 192.168.0.1.
ĸ Can add device IP address/ Domain name by manual, clickǏaddǐ pop following
dialog:
Ĺ Input device IP/domain name, eg input IP/Host testdvs.3322.org, port 8001,
device type “DVS/IP-CAM”,click ǏOKǐ pop following dialog:
Design and specification are subject to change without prior notice
5
Choose the right device, input user name and password, default is ĺadmin, as
following:
Click ĻǏConnectǐ, the right column will display the device address, choose
“channel 1”, hold the left button, drag it to the need window, as following:
Design and specification are subject to change without prior notice
6
3.2 The function descriptions
3.2.1 Toolbar
Followed by login info, talk, sound, snap, record, color, setup, rotation, play.
˖Click to check device user number
/: Click for Talk off/on
/: Click for Sound off/on
˖Click for current channel snap
Design and specification are subject to change without prior notice
7
/: Click to start or off record. Clickfor record path settingˈ
Click
˖Click for brightness/contrast/Saturation/color setting. Default 128 , range
is 0-255
for record playback
/: Click for current screen off/on
˖Click for screen rotation
˖Click for image quality/OSD/screen mask/MD setting
Design and specification are subject to change without prior notice
13
Click to start or stop screen switch ( mean the switch is in process).
3.2.5.2 Client_side Setup
Client Setup
Click
to setup record path/alarm trigger record period/sound/last time scene.
More than one path can be saved, the top one will be the default record path.
Record up limit 1024M/7200s
Video Switch Setting
It will realize multi-device or different channels switch in one screen. Click Ǐpageǐ
arrow to add/delete page, clickǏ stayǐ arrow to add/delete standstill period, click
Ǐ
ǐ choose display mode, hold mouse left key drag the wanted channel to the
right column or delete it by double click the channel name.
Design and specification are subject to change without prior notice
14
Local User Management
Default password is blank. After login, allow add new user and related
password/private. Password will be needed when quit under ǏFull Screenǐ.
Design and specification are subject to change without prior notice
15
Automatic_Record
Allow time record channel/period setting, save path setting inǏclient setupǐ. The
interface indicator
will blink after start this function.
3.2.5.3 Playback
Click pop following dialog, Search need file through catalog or event list.
Double click to play the file.
Design and specification are subject to change without prior notice
16
Please choose device IP under ǏDevice-side Fileǐthen
clickǏFindǐwhen check file in SD card.
Mark1:Event mean trigger MD or alarm, event record mean MD or alarm trigger
record.
Mark2:Device port file mean file save in linked SD card.
3.2.5.4 Language Version
The software support Chinese and English, click pop to
switch.
3.2.5.5 Full Screen
Click change to full screen mode, all action will be locked under this mode,
input administrator password when quit. Click the right button to pop˖
Choose to pop alarm info
Design and specification are subject to change without prior notice
17
3.3 Device property
Click or choose IP address in device list, click ǏPropertyǐ by right key to
pop dialog, setup or adjust IP addressǃDDNǃPPPoEǃbroadcast configurationǃuser
managementǃupdate online,etc.
3.3.1 Address/Port
Default IP address:192.168.0.233, subnet mask:255.255.255.0ˈgateway:192.168.0.1,
service port 8001. After change, system will register you restart your device to valid the
setup. Change service name not need restart.
Mark1: IP address will valid only after device restart.
Design and specification are subject to change without prior notice
18
Mark2: When link 2 or more devices, need change related IP address and physical
address.
Mark3: Outer net visit need mapping the service port, refer router configuration part.
DNS server needs change to current DNS IP address also.
3.3.2 DDNS
DDNS mean dynamic DNS, for unfixed IP domain name mapping. This client
software support peanut shellǃ3322 and our company DDNS service. Just apply your
domain name in the proper network station(refer to Part3.2) then click ǏOKǐ in the pop
dialog, the DDNS will valid.
ǏDDNS Service Providerǐnow support www.oray.net and www.3322.org.
ǏUser NameǐOne account can apply different domain name, the provider request
not same.
ǏPasswordǐThe related password when you apply the domain name.
ǏDynamic Domain NameǐAccording to domain integrated address.
Design and specification are subject to change without prior notice
19
3.3.3 PPPoE
The client software allow PPPoE . Link the device to phone line through modem,
dial to internet. User can visit the monitor picture by internet from long distance. Choose
PPPoE in following dialog then input user name and password then click ǏOKǐ.
Design and specification are subject to change without prior notice
20
3.3.4 Multicast
Use set device as needed to realize the multicast function.
Design and specification are subject to change without prior notice
21
Loading...
+ 51 hidden pages