COP-USA CD66IR-TVI10-24 User Manual

WARNINGS AND CAUTIONS
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT.
CAUTION
The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user the presence of non-insulated “dangerous voltage” within the product’s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to
different persons.
The exclamation point within an equilateral triangle, is intended to alert the user the presence of important operating and maintenance (servicing) instructions in the literature accompanying this product
PRECAUTIONS:
1. Persons without technical qualifications should not attempt to operate this dome device before reading this manual thoroughly.
2. Remove any power to the dome before attempting any operations or adjustments inside the
dome cover to avoid potential damage to the mechanism.
3. Inside the dome cover there are precision optical and electrical devices. Heavy pressure,
shock and other sudden adjustments or operations should be avoided. Otherwise, you may
cause irreparable damage to the product.
4. Please DO NOT remove or disassemble any internal parts of the video camera to avoid
normal operation and possibly void the warranty. There are no serviceable parts inside the camera.
5. All electrical connections to the dome should be made in strict accordance with the attached
labels and wiring instructions in this manual. Failure to do so may damage the dome beyond
repair and void the warranty.
6. For outdoor installation especially in high places or poles, it is highly recommended that the
proper lightning arrestors and surge suppressors are installed before the dome is entered into service.
7. Please do not use the product under circumstances where the limits exceed the maximum specified temperature, humidity or power supply specifications.
IMPORTANT SAFEGUARDS
1. Read these instructions before attempting installation or operation of dome device
2. Keep these instructions for future reference
3. Heed all warnings and adhere to electrical specifications Follow all instructions
4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners
5. Should the lens of the camera become dirty, use special lens cleaning cloth and solution to properly clean it.
6. Do not block any ventilation openings. Install in accordance with manufacturer’s instructions
7. Use only attachments or accessories specified by the manufacturer
8. Verify that the surface you are planning to use for attaching the dome can adequately support the weight of the device and mounting hardware
9. Protect this devices against lighting storms with proper power supplies
10. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, when liquid traces are present, or the presence of loose objects is evident or if the device does not function properly, or has received sever impact or has been dropped accidentally.
11. Indoor dome is for indoor use only and not suitable for outdoor or high humidity locations. Do not use this product under circumstances exceeding specified temperature and humidity ratings.
12. Avoid pointing the camera directly to the sun or other extremely bright objects for prolonged period of time avoiding the risk of permanent damages to the imaging sensor.
13. The attached instructions are for use by qualified personnel only. To reduce the risks of electric shock do not perform any servicing other than contained in the operating instructions unless you are qualified to do so.
14. During usage, user should abide by all electrical safety standards and adhere to electrical specifications for the operation of the dome. The control cable for RS485 communications as well as the video signal cables should be isolated from high voltage equipment and or high voltage cables.
15. Use supplied power supply transformer only.
INDEX
1 Product Introduction .......................................................................................................... 1
1.1 Package Contents .......................................................................................................... 1
1.2 Specification ................................................................................................................... 2
1.3 Performance Features ................................................................................................... 4
1.4 Function Description ...................................................................................................... 5
2 Installation ......................................................................................................................... 7
2.1 Dimension ...................................................................................................................... 7
2.2 Installation ...................................................................................................................... 7
2.2.1 Wall Mounted ................................................................................................ 7
2.2.2 Corner Mounted ............................................................................................ 8
2.3.3 Pole Mounted ............................................................................................. 10
2.3.4 Ceiling Mounted .......................................................................................... 11
2.4 Connection ................................................................................................................... 13
3. Function Instruction........................................................................................................ 13
3.1 Basic Function ............................................................................................................. 13
3.2 Special Function .......................................................................................................... 14
3.3 Screen Character Operation ........................................................................................ 14
4 OSD Menu ...................................................................................................................... 16
4.1 Menu Index .................................................................................................................. 17
4.2 Dome ........................................................................................................................... 18
4.2.1 Preset ......................................................................................................... 18
4.2.2 Scan ........................................................................................................... 18
4.2.3 Guard tour .................................................................................................. 19
4.2.4 Pattern ........................................................................................................ 20
4.3 IR ................................................................................................................................. 22
4.4 Display ......................................................................................................................... 23
4.5 Language ..................................................................................................................... 23
4.6 Reset ........................................................................................................................... 24
Appendix Anti-lightning, Anti-surge ................................................................................ 25
Appendix Clean Transparent Cover .............................................................................. 25
Appendix Common Knowledge on RS-485 Bus ........................................................... 26
1. Basic Feature of RS-485bus .......................................................................................... 26
2. Mode of Connection and Terminal Resistance ............................................................... 26
Appendix Address Code Mapping Table ........................................................................ 26
Appendix Exception Handling ...................................................................................... 29
Copyright Statement .......................................................................................................... 30
* Indicates the functions with default protocol, it might not function by using other protocols
Indicates the optional functions, only with certain mode
1 Product Introduction
1.1 Package Contents
IR Speed dome 1pc
Wall mount bracket 1pc
Power supply 1pc
Screws kits 1pc
User manual 1pc
1
1.2 Specification
Image Sensor 1/3” CMOS
Preview video resolution 1920×1080 1280×720
Mini Lumination
Signal Noise Ratio >50dB
Focus Auto/Manul
D/N IR-Cut
Optical Zoom 18*Zoom F=4.70mm~84.6mm
F-Stop F1.6(color),F2.8(IR on),Auto
Close-up INF(Color),1000mm(Far )
Horizontal Rotation Range & Speed Range:360° ,Speed:0.3~300°/s
Tilt Rotation Range & Speed Range:90° ,Speed:0.5~50°/s
Go to Preset Speed Horizontal:300°/s,Tilt:50°/s
Guard Tours 4 groups, Max.64 points/Group
0.05Lux/F1.6(Color),0Lux(IR on)
Presets 256
Power off Memory Support
Video output RJ45 10/100M Ethernet
Mini Delay Time 0.18s
60Hz:30fps(1920×1080/432×240)
Frame rate
60Hz:30fps(1280×720/432×240)
Compressed Image Format MPEG-4/H.264
Communication Protocol
2
TCPUDP, IP, HTTP, FTP, SMTP, DHCP, DNS,
ARP, ICMP, POP3, NTP
Compressed Image Rate 500Kbps~7Mbps
3 D Keyboard Pelco-P/Pelco-D supported
Power DC 12V-4A/AC 24V-3A
Back End Record Mode
Power Consumption 20W
Operating Temperature -30°~ +70°
Operating Humidity 10~85% Non Condensing
Weight 5~7kg
WIFI/3G Support
Protection IP66,Transient voltage 6000V
PDVR,PC,Megapixel HD system
card,NVR,IP-SAN
3
1.3 Performance Features
Use high performance 1/3” CMOS,and can perform perfectly in lower light environment.
Support high definition resolution 1920×1080P.
18 × optical zoom and be able to do remote surveillance .
Use Germany IR lights and can reach 120m.
Dual-stream output is supported and just need small storage space.
Support ONVIF protocol,convenient to connect to third party.
4
1.4 Function Description
Alarm Linkage
Intelligent dome camera supports 4 switch alarm inputs, 1 switch output and 1 digital output. When the dome camera has detected the alarm closed signal, it will run the preset action which can be one of the calling preset points or no action.
Auto-adaptive to Protocol and Module
The dome can auto-adaptive to the multi protocol and most of the module without changing the DIP switch.
3D Allocation
With this function users can move the image of some area to the center of screen according to specified level and vertical coordinates and auto control to zoom according to zoom parameter set. Screen coordinate location and zoom local can be available via the software support.
Privacy Masking
In the monitoring scope, areas that users can’t or aren’t willing to make show in the screen of the monitor can be set as privacy protected area (area masking), such as area where customers enter the password in monitoring system of bank or some doorway.
Trace Memory (Pattern Scan)
The traces of camera’s any running action in every directions of PTZ can be saved, which is called pattern scan. In pattern scan the camera turning to up, down, left and right and zooming in or out can be saved. This function remembers and imitates a process of operator’s operation.
This dome camera has 4 path patterns. Each path can record 512 different instructions or the longest 15mins’ path operation. Opening any one of the paths can remember automatically the present running trace and scan cyclically according to the recorded trace.
Zero Alignment
There is a point specified as zero point. When the dome is working, the preset point is not accurate caused by the operator. User can make the dome automatically enable the zero alignment by operational order.
Auto Flip
In the manual scanning mode, when beyond the maximum angle in tilt and if the joystick is held continuing in tilt direction, the dome will automatically rotate 180 degree in horizontal direction to maintain continuity of scanning. So vertical 180° continuous monitoring comes true.
Focus
The auto focus enables the camera to focus automatically to maintain clear image. User can use manual focus to get expected image in special condition.
Under the following conditions camera will not auto focus on the camera target:
(1) Target is not in the center of the screen;
(2) Attempting to view images that are far and near at the same time;
(3) Target is strongly lighted object, such as neon lamp, etc.;
5
(4) Targets are behind the glass covered with water droplets or dust;
(5) Targets are moving quickly;
(6) Monotonous large area targets, such as wall;
(7) Targets are too dark or faint.
BLC(Back Light Compensation)
If the light of background is bright, the target in the picture may appear dark or as a shadow. BLC enhances exposure of the target in the center of the picture. The dome adjusts the iris according to the center of the pictures. If there is a bright light source outside this area, it will wash out to white. The camera will adjust the iris so that the target in the sensitive area will be properly exposed.
Iris Control
Factory default is automatic camera aperture, in mode of which camera senses changes in ambient light through moving and adjust automatically lens aperture to make the brightness of output image stable.
Ratio Speed
Intelligent pan and tilt speed is variable depend on the zoom factor. When zooming in, the speed will become slower and when zooming out, the speed will become faster.
360 Scan
Dome 360°clockwise continuously scans the display scene at set speed in horizontal direction under the condition that pitch angle remains the same. In the scanning status, operator can move the joystick to exit from scanning.
Preset
After the dome camera keeps arbitrary PTZ location, it will automatically move to the defined position when preset is called.
Guard Tour Scan
Dome patrol scans according to certain edited preset order.
Limited Points Scan (A-B Scan)
The dome operates reciprocating scanning the real scenarios at a certain speed between the set left and right points. The range of left and right points boundary is 20° - 340°.
Power Off Memory
This feature allows the dome to resume its previous preset or status after power is restored. By default setting, the dome support power up memory, which improves the reliability and avoids repeated settings of the parameter.
Park Action
If users don’t operate the dome in set time, it will automatically run preset specific mode (pan scan, A-B scan, park action, cruise, preserve action etc.).
Multilanguage OSD Menu
The available language on screen menu can be English, German, Italian, French or Spanish.
6
Loading...
+ 25 hidden pages