COP-USA CD65ME6X User Manual

Page 1
360° Vandal Proof Mini Speed Dome Camera
High Resolution 1/3” COLOR CCD Dome Camera
CD65ME6X
* Mini Speed dome Camera * 32 Preset / 0~255 ID * 1/3” High Res. Star Light * 480TVL Slow Shutter 0.001Lux * 6x Zoom 3x 5~15mm 2x Digital Zoom * Rs-485 Control
Pelco D 2400BPS ID: 01
* DC 12V 1000mA
Video
RS485
E S
C
D I SP
PR
S R
E U
T
N
P AT
S
T
H
E
ER
O
TUP
M
N
E
DEL
E TE
A
B
C
-/--
SH
OT
CA
M S P EE
D
F
F CO
CO U
U S
S
+
+
A
FO
U TO
O
C
P
U
EN
S-
IR
IS
S1
Z
C
O
LO
O
M+ S E
F
1
Z OOM
-
S 3S2
F2
P1
S
4
F3 P 2
P5
Remote Control and receiver
F
4 P 3
P6
P4 P 7
P 8
RS485
-B / +A
RS485
Optional
Pelco D 2400bps ID:01
Video
RS485
6x Zoom
DC IN
DC IN
Optional
Camera: COLOR 1/3" CCD 480TVL 0.1LUX Dome Type: 4" Indoor/Outdoor PTZ dome Protocol: P/D Baudrate: 1200/2400/4800/9600 bps Address: 0-255 Pan Rotation: 360°Continuous rotation Tilt Rotation: 0°- 90° Max Pan Speed: 60°/Sec Max Tilt Speed: 30°/Sec Preset speed: 100°/Sec Preset accuracy: ±3° Preset points: 32 Points
Pattern Tours:
Auto Scan:
Programmable preset position with fixed zoom
Yes (Progr
up to 32 preset points
amable speed and left right limited point)
Power-off memory: Current setting and state
(Include Pattern, Not include auto scan)
Home position:
Yes (Programmable auto home position)
Zoom: Optical 3X (5-5mm) Protection: IP66 for outdoor use(Wall Mount) Operating: -5 °C ~60 °C Power:
12VDC 1000mA
Communication: RS485 (+/-)
* Specifications are subject to change without notice
** Designed in U.S.A.
Page 2
MINI SPEED DOME INSTRUCTIONS
CD65ME6X
NOTICE:
3X OPTICAL ZOOM : use [OPEN] / [CLOSE].
2 X DIGITAL ZOOM : use [ZOOM+] / [ZOOM-].
RS-485 , PELCO-D , CAM ID: 1.
Type of
communication
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6
PELCO-D ON ON OFF OFF OFF OFF PELCO-P/4800 ON OFF PELCO-P/9600
OFF OFF ON OFF
Dome
Address
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 DIP-7 DIP-8 DIP-9 DIP-10 1 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF OFF OFF 7ONONONOFFOFFOFFOFFOFFOFFOFF 8 OFF OFF OFF ON OFF OFF OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF OFF OFF
……
1023 ON ON ON ON ON ON ON ON ON ON
Selection of Protocols Normal Baud Rate
OFF ON
Bit of Switch
PI
D
NO
D IP
N O
6 5
4 3
2
1
01
8
9
4 6 5 7 3 2 1
Page 3
Remote Control Functions
Call Camera:
As a Factory Default the PTZ is set to: PELCO-D / 2400BPS / ID:01
Press
[CAM] + [ 1 ] to get control of the PTZ
P/T Control:
Move UP / DOWN / LEFT / RIGHT
Speed Control:
It Adjusts the Speed of your PTZ
Press [SPEED] and any number from
1-63 ( remmber to use [-/--] button when using
double digits numbers.
Focus Button
Shorcut for P/T Speed.
S1 - SLOW
S2-S3 - MEDIUM
S4- FAST
O
F
UC +
S
O
F
UC -S
O
Z MO
-
OZ
MO +
OF +
S
RI S
I
LC
S
O
E
PO NE
/- -
-
ES U
T
P
ID
PS
C
A
B
E
C
OH EM
UR N
AP T
T
RE N
RP
E
S
T
H
S
TO
AC M
ED E
L E
T
4F
1
P
1S
5
P
PS
EE D
U
A O
T
4S
3S2S
3F2F
1
F
4P
8
P
3
P
2P
7P6
P
Calls preset positions:
i.e: Press [ SHOT ] + [ 1 ] for preset 1.
Backspace:
Backspace for when inputting numbers
RUN PATTERN:
START and STOP the Pattern Motion
HOME:
used to save preset position on A and B.
press [PRESET] for 3 sec. + [HOME].
PRESET:
To save a Preset position,
press this button for 3sec. until shows
[SET----], input a number and press [ ENTER]
DISP:
Selects different displays on Remote receiver
Return:
Return to ID address display
the receiver display will show [A00...]
Button for over 10 numbers:
For address over 10, press [-/--] before any other number. i.e if you want to call the ID 14 simply press [CAM]+[-/--]+[14] .
ENTER / Confirm Button:
Use this Button to confirm Save/ Clear Presets.
AUTO SCAN: Scans from position A to B Set the Positions A and B and press [AUTO] use [ENTER] butto to quit SCAN.
Digital Zoom
Optical Zoom
PRESET POSITIONS SHORTCUT
Numbers:
Used when Calling / Setting presets or calling cameras
SET PATTERN:
Press for 3sec. and wait until shows [ PsTa] input the preset position and press enter then press for 3sec. until shows [PsTo] input a preset position and press enter press [ RUN ] to start /stop pattern
DELETE:
Press this button for 3s until it shows [ CLr---] and then press the preset number to be Erased and Press [ENTER] to confirm.
A/B Button:
These buttons are for Pan Scan function. Press [PRESET] for 3sec. and [A] (for left position)and [PRESET] for 3sec. and [B] (for Right Position)
Protocol / Baudrate
SETUP:
Setup the Receiver Protocol and Baudrate Press this button for 3s and use [UP]/[DOWN] to change protocol and [LEFT]/[RIGHT ] to change Baudrate and [ENTER] to save.
Loading...