COP-USA CD55-SDI User Manual

Page 1
HD-SDI High Speed dome Camera Series
USER'S MANUAL
Page 2
WARNING
CONTENTS
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERTANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER ( OR BACK). NO
USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO
QUALIFIED SERVICE
PERSONNEL
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
FCC COMPLIANCE STATEMENT
FCC INFORMATION: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WHEN THE EQUIPMENT IS OPERATED IN A COMMERCIAL ENVIRONMENT. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTION MANUAL, MAY CAUSE HARMFUL INTERFERENCETO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCEAT HIS OWN EXPENSE.
1. Precaution............................................................1
2. Features...............................................................2
3. Packing list...........................................................3
4. Installation........................................................... 4
5. Operation.............................................................9
6. OSD....................................................................10
7. Adress and Protocol Setting..................................18
8. Adress ID.............................................................21
ENGLISH
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS‘S AUTHORITY TO OPERATE THE EQUIPMENT.
WARNING: THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKEADEQUATE MEASURES.
CAUTION: BEFOREATTEMPTING TO CONNECT OR OPERATE THIS PRODUCT, PLEASE READ THE LABEL ON THE BOTTOM AND USER'S MANUAL CAREFULLY
Technical specification are subjects to change without prior notice. Manual may contain mistake or print error. All trademarks mentioned belong to their respective owners.
Page 3
1.PRECAUTION
2.FEATURES
Refer all work related to the installaion of this product to qualified service personnel or system installers.
Do not attemp to disassemble the appliance
To prevent electric shock, do not remove screws or cover. There are no user­serviceable parts inside. Contact qualified service personnel for maintenance
Handle the appliance with Care
Do not strike or shake, as this may damage the appliance. It should be protected against extreme pressure, vibration and humidity during transportation and storage. Damages caused by improper transportation avoid the warranty.
Do not use strong or abrasive detergents when cleaning the appliance body and transparent cover.
Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent and wipe gently.
Do not operate the apliance beyond its specified temperature, humidity or power source ratings.
Do not use the dome camera in an extreme environment where high temperature or high humidity exists. Use the within -10°C to +50°C(14°F to 122°F) and a humidity below 90%. The input power source is 24V AC, 50/60Hz and requires 1000mA. Use the within -20°C to +60°C(-4°F to 140°F) and a humidity below 90%. The input power source is 24V AC, 50/60Hz and requires 2500mA.
Do not expose the indoor model of dome camera to water or moisture, not try to operate it in wet areas.
Take immediate action when the indoor speed dome becomes wet. Turn off the power and refer servicing to qulified service personnel. Moisture may damage the appliance and cause eletric shock.
Do not point the camera lens directly to sunlight or any strong light source.
This will cause permanent damage to the camera and avoids the warranty.
Read this user's manual carefully before operating the appliance.
Make sure that local electric safty standard are followed when using or installing the appliance
Do not install the camera in other orientation as designed.
And do not bend or squeez the sturctiure, as this may damage the mechanic sturcture of the appliance and avoids the warranty.
Do not touch the Cover with bare hands or any object.
These will scratch the serface and affect the image qulaity.
indoor models
outdoor models
The HD-SDI High speed dome camera series are designed for in- and outdoor video surveillance application. The integrated, motorized pan-tilt mechanic allows user to point the camera to any position( 360° horizontal and 180° vertical). Both series can be equipped with digital zoom camera modules, which provide zooming functon from 18 to 36 times (optical) and advanced image features.
Key features:
- 360° Pan and 180° Tilt range (90° with auto-image-flip)
- Support most well-known camera modules
- 128 preset points memory (80 can be used for auto tour function)
- 4 patt ern tou rs
- 1 Scan t our
- Basic setup directly from Keyboard.
- Advanced setup through OSD (On Screen Display) menu.
- up to 24 privacy masking zones ( despends on camera module)
- 7 alarm input & 2 output ( 4 input & 1 output pre-wired)
- Multi-Protocol through RS485.
- Dirction Indicator on screen
- Aluminum Alloy structure with high intensity and heat-sinking
- High-precision step-motor for flicker-less image during movement.
Camera Features:
- 1/2.8" Sony Exmor CMOS Sensor
- Full-HD HighResolution up to 1080p 30fps
- Built-in True Day&Night Filter
- Auto-Focus
- Auto-Iris
- Auto-Wide Dynamic Range
- Auto-Brightness control
- Auto-Balance
- Auto Slow-Shutter
- Electric Image Stabilization
- Stablezoom
Temperature monitoring and protection
- Alarm notification will be displayed once the inner temperature exceeds the limit
- In low temperature area, the dome camera will only start after the operation temperature is reached.
- Cooling fan activity is managed by the CPU ( extends the duration)
Other features:
- Proportional pan for Focus / Speed on different zoom factor.
- Auto-resuming user-defined action, such as tour, pattern or scan after selectable idle time.
- Power-upAction activates tour or pattern by default.
®
ENGLISH
12
Page 4
3.PACKING LIST
4.INSTALLATION
Indoor Typ1
Indoor Type2
Oudoor Typ1
Core Unit 1 Piece
Core Unit 1 Piece
Core Unit 1 Piece
Indoor Roof-Mount base platte 1 piece
Embedded Mount
1 piece
Outdoor housing and cover 1 piece
High Speed dome Camera Series
USER'S MANUAL
Instruction and operation manual 1 piece
dome cover 1 piece
Spare dome cover 1 piece
High Speed dome Camera Series
USER'S MANUAL
Instruction and operation manual 1 piece
High Speed dome Camera Series
USER'S MANUAL
Instruction and operation manual 1 piece
Safety Instructions before starting
- Do not install and operate this appliance in a flammable and explosive environment.
- Make sure that the installation is done according to the local electricity safety regulation of your country. .
- Before installation and mentainence, make sure that the appliance is disconnected from the power source.
- Do not use any power source other than 24V AC, in order to prevent damages to this device. For details, please refer to the section "Precaution" in previous chapter for more details.
- Handle the device during the installation carfully. Falls or extreme vibration may cause irrepairable damages and avoid the warranty.
- Do not install or operate the appliance near any high-voltage devices or high-voltage cable. The safety distance should remain at least 50 m.
- To archive best image quality, its recommanded to use underground cable shielded with steel tube. Do not install the cable without any protection.
- In a thunderstorm area or region with high inductive voltage, such as high voltage transformer stations, it is necessary to use additional lighning-proof equipments or lightning rob for protection.
- For outdoor installation, lightning-proof and grounding of the device should be considered. Please refer to the industrial saftey regulation and request of your country .
- Grounding of the appliance should consider anti-interference and fulfill the saftey requirements. Do not connect the ground with short-circuited or other high-voltage electric network.
ENGLISH
- The resistance of down conductor should not exceed 4 Ohm, and its thickness should
WARNING:
The transparent cover part is sensitive and should be handled with care. Do not touch or rub the surface in any way with the protection foil.Inproper cleaning method will cause permanent scratches on the cover and cause unclear image or focusing error of the camera. For Cleaning the cover, please replace the original first with the spare cover, and wash it by diving into warm water with non-corrosive cleaning solution.
be at least 25mm²
- This appliance has the lightning-proof function which can prevent damages caused by high-voltage pulse, such as lightning strike below 1500.
- This appliance meets the Ip66 standard for water and dust proof. Do not install the in­door model for out-door application which is not designed with water protection. Make sure that the installation is protected from long-time water-drop or spatter, which may damage the appliance.
- Make sure that the enviroment of installation meets the requirement of the appliance,
Unpacking
such as holding the weight, enough spaces for bracket and power supply.
The speed dome is packed with protection. please take out the core unit carefully. In case of transportation please use the original packing box.
34
Some models may not be available in your country, please contact VIDO distributor for more details
Page 5
4.INSTALLATION
4.INSTALLATION
Connector description
The wiring cable of G65 and G70 provides connectors for power supply, video and I/O interface
RED: AC 24V BLACK: AC 24V
Power
To power supply
Connector
Green:RS485+
RS485 Connector RJ-11
Yellow:RS485-
To Keyboard or DVR decives for telemetric control
Inner Conn: Signal + Outer Conn: Ground
Video output
HD-SDI Video Output to monitor or DVR
BNC
Using optional accessories
The High speed dome camera can be connected to various optional accessories through the standard connector types, which simplifiy the cable handling and avoids possible mistakes. All accessories are tested for max. compatibility and best performance.
Outdoor power adaptor box AC 230V to AC 24V
AC 24 Power
supply
RS 485
Alarm I/O
AC 230V
Power input
Indoor power adaptor AC 230V to AC 24V
AC 24 Power supply
Power Box
AC 230V Power input
3-Axis keyboard
controller
RS 485
Monitor
21”High Res. security Monitor.
DVR-Server
Professional Real-time 16 Channel DVR
Telemetric control camera setup
ENGLISH
Alarm I/O 1
Alarm I/O 2
RED: Alarm in 1 PINK: Alarm in 2 YELLOW: GREEN:
Alarm in 3
Alarm in 4 BLACK: COM WHITE: Alarm output - N.O BLUE: Alarm output - N.C
AQUA
Alarm output - N.C2
:
BROWN: Alarm output - N.O2 GRAY: Alarm in 7 PURPLE: Alarm in 6 ORANGE: Alarm in 5
I/O interface to additional alarm sensor or control devices
RS 485 cable
The telemetric control of the appliance uses Rs485 serial communication with half­duplex transmission technology. Depends on the cable typeand baud rate, the transmission distance could vary. The following table shows max. distances based on cable with 0,56mm (24AWG) twisted pair:
Baud Rate
2400 bps 4800 bps
9600 bps
19200 bps
Max. Distance
1700m
1100 m
700m
400m
Video signal
Due the environmental interferences, such as eletromagnetic and induction fields, or number of connected appliance on the RS-485 bus, the transmission range may be less, e.g with cable thinner than than 24AWG.
56
Page 6
4.INSTALLATION
4.INSTALLATION
Star-Connection
The star-form connection is mostly used. it enables the connection of different dome cameras in longer distance. It is recommended to use RS-485 distributor to ensure the telemetric data transmission:
The advantage of star-connection is that every channel can work
RS-485 cable up to 1000m per channel
RS-485
Distributor
independently and take a cable length up to 1000 meters( depends on cable quality). In case more dome camera are installed, the star­connection can be extended with
Termination activated on every end.
additional RS-485 distributors.
Video Cable
coaxial cable with 75 impedance with copper conductor at center conductor, and
Ω shielded with 95% copper. The following table shows different cable type and its maximum length:
Cable standard
RG 59 /U
Max. Distance (m /ft )
100m / 300 ft
The values are for reference only. Depends on the cable quality and environmental condition, the transmission distance might be less.
If the cable length is more than 100 m, it is recommended to use optional accessories, such as Video Amplifier or Fiber Trassmission Converter, for boost the Video Signal.
Up to 100m, coaxial cable
VideoAmplifier
HD-SDI High Speed Dome
Extend connection distance with Video Amplifier
(optional)
HD-S DI DVR Ce nter
Real time
(optional)
HD-SDI Monitor (optional)
Installing the core unit to base board.
The HD-SDI HSD Series core unit and base board are packed seperatly, in order to be protected through the transportation. After unpaking and during the installation, the core unit should be installed as following:
Installing the core unit by pushing into the housing.please note the position of connector. For releasing, please press the lever-lock to core and pull off the unit.
Lever­Lock
Once the base board is connected to power, the power LED will light.
Connector Interface
Heater connector on outdoor
Rubber ring
housing
Power LED
Metal Clip
WARNING: Do not pull or hold the connector interface with force. It is design only to connect the core unit and the base board. Any presure on connector will cause damage and avoids the warranty.
cable
Outdoor housing cover
Screws
Safety spring
Heater connector
Optional bracket accessories
The Indoor and Outdoor Model can be equipped with various bracket accessories for indoor and outdoor installation. Please contact your distributor for further details.
Ceilling mount
Wall mount and
Power box
Corner Mount
Indoor Wall mount
Pole Mount
Outdoor Power Box
ENGLISH
Up to 20km, Fiber cable
Fiber transmitter (optional)
HD-SDI High Speed Dome
Extend connection distance with Fiber Transmission
7
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Fiber receiver (optional)
Real time
HD-SDI DVR Center
(optional)
HD-SDI Monitor (optional)
Indoor embedded mount
Indoor ceilling mount
Extended wall mount
Swan-Neck Mounting bracket
Wall mount
8
Page 7
5.OPERATING THE SPEED DOME
6.OSD
Initial Screen
FIRMWARE V1.0 Protocol: FACTORY Dome Address: 001 Comm 9600,N,8,1
- V1.0:
Current firmware version
- Protocol:
- Dome address:
setup " for details.
- Comm 9600,N,8,1:
9600: N, 8, 1:
The intial screen will stay remain on until any user action is being taken. If the power­up action is set, the initial info wil vanish immediatly.
Operation Screen
The operation screen can display additional information.
Temperature: current temperature inside the speed dome( °C) Cam title: User definable camera title Zone: Current zone name Pan deg.: Pan angle, 0-359° Tilt deg.: Tilt angle, 0-90° Zoom Factor: Zoom factor
Display of the information can be activate or deactivate through the OSD menu. please refer to the system setting for detais.
control protocol which currently used
Address ID of speed dome. please refer to the section "Protocol
current setting of the serial communication interface.
Baud rate. please refer to section "Baud-Rate setup" for details
No parity bit, 8 bit length, 1 stop bit. this setting can not be changed
After powering up, the camera will enter the self-test mode and display the status screen( as in the picture left).It contains information about the model and current settings.
Temperature
32.0CAM TITLE
ZONE-1 285 78 18X
Zoom factor
Tilt degree Pan degree
Zone description
OSD Menu
The HSD Series are equipped with new OSD-Menu function. All operation functions and camera related settings can be changed or modified here. In order to use the OSD function, a telemetric controller device, such as Keyboard, DVR or other devices with similiar function is necessarily required. please make sure that the device used is physically connected to the dome properly, and all connection parameters are set correctly.
How to start the OSD menu
To start the OSD Menu, you need to press following key on the keyboard:
With or
With or
In case a DVR is used for the OSD, select “goto preset 95” or 2 X “goto preset 9”. Please refer to the DVR’s operation manual for more details.
Note that in some certain situations, it is not possible to enter the OSD menu:
1. the dome is running tour
2. performing PTZ operation
3. dome is receiving command other than OSD-request from the keyboard.
please stop the operation and try again.
Main menu and navigation
call
Shot
9 5
9 5
Main Menu
SYSTEM SETTING CAMERA SETTING FUNCTION SETTING WINDOW BLANKING ALARM EXIT
Enter
Enter
After entering the OSD Menu, the screen will show menu items . Use the controller’ joystick to navigate through the menu’s main and sub items by moving in the direction. The angle mark on the beginning of every items indicates the selection.
UP, DOWN: - Moving between current menu items
- Changing the value in subitems RIGHT: - Enter the selected menu item
- Confirm the value change and return to item selection LEFT: Exit from sub menu
2 X
2 X
call
Shot
Enter
9
Enter
9
ENGLISH
PTZ operation
For the surveillance operation, the dome can be controlled from a keyboard device , Multiplexer or DVR through RS-485 Interface. Make sure that the cable is connected and the settings (baud rate,Address ID and protocol) of both keyboard and the dome are configured correctly. For more description about the PTZ operation, please refer to the user’s manual of the keyboard.
910
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Symbols and indicator
Cursor.
Sub item is selected. use up or down to change value
This item has subitem(s)
For more inforamtion, please refer to the illustration on the next page for the OSD menu structure.
Page 8
6. OSD - MAP 6.OSD - System Setting
MAIN MENU
SYSTEM SETTING
CAMERA SETTING
FUNCTION SETTING
WINDOW BLANKING
ALARMS
EXIT
ALARMS SETTING
ALARM NUMBER 001
ALARN ACTION NONE
ACTIVATEAUX NONE
ALARM PRIORITY
BACK
EXIT
ALARMS
RESUME OFF
SEQUENCE 60
RESET DELEY 030
ALARM CONTACT N/O
ALARM SETTING
WINDOW BLANKING
WINDOW NUMBER 01
EDIT WINDOW
ENABLE WINDOW ON
CLEAR WINDOW
BACK
FUNCTION SETTING
ARM SETTING
ARM SETTING
BACK
EXIT
EXIT
PRESETS
SCAN
PATTERNS
TOUR
ZONES
TIME RUNNING
ADVANCE SETTING1
DAY SUN
AUTO-TRACKING
UNARM TIME N/A
ARM STATE OFF
ARM TIME N/A
BACK
EXIT
BACK
EXIT
PS SCAN O N
STABLE Z OOM OFF
DNR 00
BACK
EXIT
EDIT PRESET LABEL
PRESETS
PRESET NUMBER 001
LABEL: PRESET-01
BACK
EXIT
SET PRESET
SHOW PRESET
CLEAR PRESET
EDIT PRESET LABEL
BACK
SYSTEM SETTING
EDIT DOME LABEL INITIAL INFO DISPLAY SETUP MOTION CLEAR PASSWORD SETUP CLOCK SETTING BACK EXIT
System Setting
In system setting menu, you can modify operation and display setting, such as dome label, temperature and display of various value on the operational screen.
ENGLISH
Dome Label:
EDIT DOME LABEL
LABEL
-- -
-- -
-- -
-- -
-- -
EDITTOUR
EDIT SCAN LABEL
LABEL: AUTO SCAN
SCAN
SCAN NU MBER 01
SCAN SPEED 63
EXIT
EDIT PATTERN LABEL
BACK
EXIT
PATTERNS
PATTERN N UMBER 1
SET LEFT LIMIT
SET RIGHT LIMIT
CLEAR SCAN
RUN SCAN
EDIT SCAN LABEL
BACK
EXIT
LABEL: PATTERN-1
BACK
PROGRAM PATTERN
RUN PATTERN
EXIT
CLEAR PATTERN
EDIT PATTERN LABEL
BACK
TM TM TM
P0-S- P0-S- P0-S-
TOUR
EXIT
EDIT ZONE LABEL
LABEL: ZONE-1
00-0-00 00 0 00 00 0- 00
00-0-00 00 0 00 00 0- 00
00-0-00 00 0 00 00 0- 00
NUMBER 1
TOUR
EDITTOUR
RUN TOUR
BACK
00-0-00 00 0 00 00 0- 00
00-0-00 00 0 00 00 0- 00
CLEARTOUR
BACK
EXIT
BACK
EXIT
ZONES
ZONES N UMBER 1
EXIT
SETLEFT LIMIT
TIME RUNNING
START TIM E 00:00
RUNNING NONE
TIME CHANNEL 1
DAY SUN
SETRIGHT LIMIT
CLEAR ZONE
EDITZONE LABEL
BACK
BACK
EXIT
EXIT
AUTO-TRACKING
DAY SUN
STATE ON
START TIM E N/A
END TIM E N/A
SENSITIVE LOW
TRACKING-ZOOM OFF
SETLEFT LIMIT
SETRIGHT LIMIT
BACK
EXIT
BACK
EXIT
SPEED DOME V
ENTRANCE
INITIAL INFO
2.66
1. use UP or DOWN to change the charactor.
2. u se RIG HT to m ove t o next c har.
3. u se RIG HT to m ove t o last c har a nd save.
4. u se Lef t to fi rst ch ar an d canc el.
Initial information:
Shows the information about current setting.
PROTOCOL:FACTORY DOME ADDRESS:001 COMM:4800,N,8,1 BACK EXIT
CAMERA SETTING
SYSTEM SETTING
ZOOM SPEED HIGH
EDIT DOME LABEL
DISPLAY SETUP
SHUTTER N/A
IRI S N/A
BRIGHT N/A
R GAI N N/A
B GAI N N/A
ADVANCE SETTING1
IR CUT ON T IME N/A
ADVANCE SETTING 2
BACK
EXIT
CLOCK SETTING
BACK
IR CUT OF F TIME N/ A
IR CUTTER FILTER AUTO
EDIT DOME LABEL
LABEL:SPEED DOME
BACK
EXIT
DIGITAL ZOOM ON
BLC MODE OFF
SLOW SHUTTER ON
LINE SYNC N/A
WDR MODE AUTO
ADVANCE SETTING 1
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORDSETUP
ADVANCE SETTING2
THRES HOLD 10dB
MAX GAI N 28dB
EXPOSURE COMP OFF
MIRRO R OFF
FLIP OFF
INITIAL INFO
EXIT
B
NEXT
AE MO DE AUTO
W M ODE AUTO
HI- RESOL UION ON
BACK
EXIT
FF
FF
2.66
VIDO B02
96
DISPLAY SETUP
DOME ADDRESS: 001
COMM: 00 . N.8.1
DOME LABEL OFF
PRESET LABEL OFF
ZOOM LABEL O
BACK
ZONE LABEL OFF
EXIT
DIRECTION LABEL O
TEMPERATURE LABEL OFF
SPEED DOME V
PROTOCOL :
ADVANCE SETTING
ESET FREEZE FF
PR N O
AUTO FOCUS OFF
DEFOGGER 015C
EIS ENABLED ON
HEAD UP OFF
BACK
EXIT
NONE
NONE
MOTION
PARK ACTION
AUTO FLIP ON
PROPORTION PAN ON
PARK TIME 005
TIME LABEL OFF
DATE LABEL OFF
BACK
EXIT
POWER UP ACTION
CLEAR
FAN ENABLED 040
TEMP C/F CENT
ADVANVE SETTING
BACK
EXIT
CLEAR ALL ZONES
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL TOURS
CLEAR ALL WINDOWS
FACTORY DEFAULTS
RESTART
PASSWORD SETUP
BACK
EXIT
OLD PASSWORD : ******
CLOCK SETTING
CONF PASSWORD : ******
TIME 00:00:00
DATE 01/01/01
DAY MON
ENABL E PASSWO RD OFF
BACK
BACK
EXIT
EXIT
NEW PASS WORD : ** ****
DOME LABEL OFF PRESET LABEL OFF ZOOM LABEL ON ZONE LABEL OFF DIRECTION LABEL ON TEMPRATURE
LABEL OFF BACK EXIT
Display setup
Actuvate the display for the on-screen info in operaton mode.
Dome label: Preset label: Zoom label: Zone label: Direction label:
the name of dome
shows the labe of every preset
shows zoom factor on screen
shows the zone name
shows the coordinates
Temperature label:
shows the cur. temp in the speed dome
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
Page 9
6.OSD - Motion, Clear OSD - Camera Setting
MOTION
AUTO FLIP ON PROPORTION PAN ON PARK TIME 005 PARK ACTION SCAN POWER UP ACTION AUTO FAN ENABLED 040 TEMP C/ F CE NT ADVANCE SETTING BACK EXIT
ADVANCE SETTING
EIS ENABLED N/A PRESET FREEZEN OFF AUTO FO CU S OF F DEFOGGER 015C HEAD UP OFF BACK EXIT
CLEAR
CLEAR ALL ZONES CLEAR ALL PRESETS CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL WINDOWS FACTORY DEFAULTS RESTART BACK EXIT
Motion control
AUTO FLIP
180°
PROPORTIONAL PAN:
the dome will adjust the pan and tilt speed automatically for comfortable viewing.
PARK TIME:
custom defined action( park action).The range is from 1 to 240 minutes. This function can be deactivated by setting the minute to 0.
PARKACTION:
the idle time (park time). Selectable between Preset, Scan, Pattern (Nr), Tour or None.
POWER UPACTION:
be started after power up and self test. Selectable between Auto,Preset 1, Scan, Pattern (Nr), Tour or None. By selecting Auto, the dome will resume the last action before power off.
FAN ENABLED:
temperature.
TEMP C/F:
Fahrenheit.
: Auto. Image flip in tilt range from 90° to
depends on the zoom factor,
defines the idle time prior to start a
the action which will be started after
defines the action which will
Activate Fan when the dome reach the
Switch the temperature unit between Celius and
Advance Setting
EIS ENABLED: E I S
function is variable on certain camera modul.
PRESET FREEZEN: AUTO FOCUS: DEFOGGER: HEAD UP:
combine with Camera Flip function.
Clear
You can clear setting’s memory or reset the camear to factory default. The follwing functions are supported:
- Clear Zones
- Cl ear al l pre sets
- Clear all patterns
- Clear all tours
- Cl ear al l win dows
- Factory defaults
Warning: T he cl ear ac tio n can no t be un d one . once a item is cleared it is impossible to re trie ve th e del e ted s ett i ng. P leas e mak e sur e that the requested clear action is desired.
Enable „ lectric mage tabilization“. This
Freeze the image immediately.
Switch ON/OFF the Auto Focus
Activate Heater/Fan on the cold temperatur.
Switch ON/OFF the proportional PT moving. Can
PASSWORD SETUP
O
LD PASSWORD : ****** NEW PASSWORD : ****** CONF PASSWORD : ****** ENABLE PASSWORD OFF BACK EXIT
CLOCK SETTING
TIME 00:00:00 DATE 01/01/01 DAY MON BACK EXIT
CAMERA SETTING
ZOOM SPEED HIGH DIGITAL ZOOM ON BLC MODE OFF SLOW SHUTTER ON LINE SYNC N/A WDR MODE N/A ADVANCE SETTING 1 ADVANCE SETTING 2 BACK EXIT
ADVANCE SETTING 1
IR CUTTER FILTER AUTO
IR CUT ON T IM E N/ A IR CUT OF F TI ME N /A
THRESHOLD 10dB MAX GAIN 28dB EXPOSURE COMP OFF MIRROR OFF FLIP OFF NEXT
Password setup
You can change password to access the OSD menu. Default Password is 000000.
Clock setting
Some function like Auto-Tracking require the timer for activation. Time: HH:MM:SS DATE: YY/MM/DD DAY: MON-SUN
CAMERA SETTING
In camera setting menu, you can setup camera module related settings. please note that depends on module’s capability, some function may not available. please contact your local sales representative for detailed information.
ZOOM SPEED:
function.
DIGITAL ZOOM:
function of the camera module.
BLC MODE:
improves the image when an object has strong back light.
SLOW SHUTTER:
of the camera, which provides a higher light sensibility in low-environment.
WDR:
Activates the Wide Dynamic Range function, which improves the image contrast when an object has very strong light on background. Only available with camera modules with WDR.
defines the speed when performing zoom
Activate or deactivate the digital zoom
Select the Back Light Compensation mode,
Activates the Slow Shutter function
ADVANCE SETTING1
IR CUT FILTER:
Filter (IRC), also known as “DAY/NIGHT” mode. with the removal of IRC, the camera turns into Black/White mode and has higher sensibility to low-light or IR-Light in the night. Selectable between On, Off, Auto or Time. Only available on camera module with IRC function.
MAX GA IN : EXPOSURE COMP:
of a short exposure.Configure the shutter speed of a long exposure by setting the ratio with regards to a short exposure with the exposure ratio parameter. Blocked-up shadow correction is not performed in this mode.
Mirror: Flip:
This function reverses the camera horizontally.
This function turns the camera upside down.
Enables the removal of Infrared Cutter
improve the image quality in the Night modus
This mode fixes the shutter speed
ENGLISH
13
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
14
Page 10
OSD - Preset, Scan 6.OSD - Patterns, Tours
ADVANCE SETTING 1
ADVANCE SETTING 1
PS SCAN ON STAB LE Z OO M ON DNR 00 BACK EXIT
ADVANCE SETTING 2
AE MODE AUTO
SHUTTER N/A IRIS N/A BRIGHT N/A
WB MODE AUTO
R GAIN N/ A
B GAIN N /A HI-RESOLUTION OFF BACK EXIT
These function are o camera modules
PS SCAN:
on the WDR mode.
STABLE ZOOM:
using the Image Stabilizer function in accordance with the zoom ratio, and smoothly zooming up to approximately ×40 using a combination of the optical zoom and digital zoom.
DNR: D N R
Activate Progressive Scan, can be combine
Set the 2D/3D igital oise eduction.
nly available with the E-Serie
This function is performing correction
ADVANCE SETTING 2
Under the advanced setting, you can make improvements to image quality due to different environmental conditions.
AE MODE:
Auto Exposure mode. Depends on the light condition in the surveillance area, you can set the AE in different modes and adjust the parameters, such as shutter speed, iris factor and brightness for the best image quality.
WB MODE:
White balance mode, a image improvement
EDIT PRESET LABEL
LABEL
ROOM 1
BACK EXIT
SCAN
SCAN NUMBER 01 SCAN SPEED 63 SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN RUN SCAN EDIT SCAN LABEL BACK EXIT
based on DSP processing. you can also adjust the Red­Gain or Blue-Gain to change the color tone.
FUNCTION SETTING
PRESETS SCAN PATTERNS TOUR ZONES TIME RUNNING AUTO-TRACKING BACK EXIT
PRESETS
ALC, PLC:
additional setting to WB function. only avialble with dedicated camera modules.
FUNCTION SETTING
In function setting menu, you can define and activate different PTZ funcitons, such as preset points, auto scan, tours and Pattern. Presets and tour functions can also be set or activated directly from keyboard device without OSD. Please refer to the keyboard’s manual for operation details.
PRESETS:
PRESET NUMBER:
Average and Peak Level Control,
PATTERNS
PATTE RN NUMB ER 1 PROGRAM PATTERN RUN PATTERN CLEAR PATTERN EDIT PATTERN LABEL BACK EXIT
G65-70 Series supports up to
128 presets. The number can be selected from 0 to
PRESET NUMBER 001 SET PRESET SHOW PRESET CLEAR PRESET AUTO-TRACKING ON EDIT PRESET LABEL BACK EXIT
15
Some products may not be available in your country, please contact our distributor for more details Some products may not be available in your country, please contact our distributor for more details
128.
SET PRESET:
Defining the preset points directly in OSD by entering this menu item and move the PTZ. press IRIS-OPEN key on the keyboard to save. If the preset is pointed within digital zoom, it will automatically go back to max. optical zoom range in order to provide the best image.
SHOW PRESET:
Moves to current preset point
CLEAR PRESET:
AUTO-TRACKING:
is called.
EDIT PRESET LABEL:
can define a name which will be shon on the operation screen once the preset is called. please choose the preset number at first. The avaialbe characters are: 0-9, A-Z, <,>,. and space.
SCAN
Th e SCAN f unc tion m ove s the P TZ bet wee n 2­predefined points in constant speed.The following parameters can be set:
SCAN NUMBER:
scan.
SCAN SPEED:
points.
SET LEFT LIMIT: SET RIGHT LIMIT: CLEAR SCAN: RUN SCAN: EDIT SCAN LABEL:
Pattern
Patte rn re cord s the u ser’s ope rat ion s teps o n pe rfor min g PTZ co ntr ol and s tor e s as a track . The Sp eed Do me ca n reco rd up t o 4 tra cks wi th ma x. 180 sec. each.
PATTERN NUMBER:
from 1 t o 4
PROGRAM PATTERN:
when selected. you can perfome PTZ movement for recording and shall not exceed 180 sec. Press IRIS­OPEN to save the track.
RUN PATTERN:
CLEAR PATTERN:
EDIT PATTERN L ABEL :
pattern.
Clear the current preset
Start Auto Tracking, if the preset
For th e curre nt preset, y ou
The Speed Dome
cruising speed between the
defines the left point.
de fine s the r ight p oin t
Delete the scan setting
starting the scan function
se t the na me fo r the sc an
Selects the pattern number,
Starts recording the pattern
Starts the current pattern
Delete curretn pattern.
Sets t he name f or current
ENGLISH
supports up to 4
16
Page 11
6.OSD - Zones and Privacy Mask 6.OSD - Alarm Setting
EDIT TOUR
TOUR DWELL 001 00-00-00-00-00-00-00-00
Tour
Tour is an auto-run through selected preset po ints w ith d efin abl e paus e tim e . A tou r can store up to 32 presets points.
00-00-00-00-00-00-00-00 00-00-00-00-00-00-00-00 00-00-00-00-00-00-00-00 RUN TOUR BACK EXIT
ZONES
ZONE S NUMBE R 1 SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT
TIME RUNNING
DAY SUN
TOUR DWELL:
preset points. selectable between 000-255(s).
TOUR PRESETS:
ke ybo ard de vic e to ent er th e p res et po i nt selection. Move the joystick with up and down to se lect t he pr eset p oin ts by nu mbe r and sa ve th e setting with IRIS-OPEN key. with IRIS-CLOSE ke y you c an mo ve to t he pre vio u s sel ecti on. I f a se lect p oin t has th e va l ue 0, a ll the f oll owin g presets points will be ignored.
RU N TOU R:
menu.
pa use ti me fo r eve ry sto p on th e
pr ess IR IS- OPEN Key o n the
St arts t he to ur and e xit t he OSD
ZONE
You c an def ine t he zon es in t he who le PT r ang e up
up t o 8 zon es
to with individual label. When the display setting “Zone Label” is activated, the la bel wi ll be d ispl aye d on th e operati on sc reen . Th e defi nit ion of t he zo nes sh oul d not be overlapped.
ZONES NUMBER: SET LEFT LIMIT: SET RIGHT LIMIT: CLEAR ZONE: EDIT ZONE LABEL :
Current zone selection
Left limit of the current zone
Right limit of the current zone
Delet the current zone
change the laben of current zone. TIME CHANNEL 1 START TIME 0 0:00 END TIME 00:00 RUNNING NONE
BACK
TIME RUNNING
You c an set u p the t imer t o sta r t a fun cti o n lik e pr eset , tou r or pat ter n. Eac h day c an be se t 4 action.
EXIT
AUTO TRACKING
AUTO TRACKING
DAY SUN
STATE ON START TIME 0 0:00
END TIME 00:00 SENSITIVE LOW TRACKING-ZOOM OFF SET LEFT LIMIT SET RIGHT LIMT BACK EXIT
Some products may not be available in your country, please contact our distributor for more details
Auto-Tracking can seach people or object with hi gh spe ed an d low li ght p erfo rma nce.
DAY: set current day STATE : acti va t e AUTO-TR ACK ING on t his day START TIME: set the time for activation EN D TIME : set t he tim e for s top th e tra cki ng SE NSIT IVE : set th e sen siti vit y for th e det ecti on TRAKING ZOOM: activate auto-zoom SET LIMIT: set the max. angle for the tracking.
WINDOW BLANKING
WINDOW NUMBER 01 EDIT WINDOW ENAB LE W INDOW O FF CLEAR WINDOW BACK EXIT
ALARMS
Resume OFF
SEQUENCE 001
RESET DELEY 030
ALARM CONTACT N/O
ALARM SETTING
ARM SETTING
BACK
EXIT
ALARM SETTING
ALARM NUMBER 001
ALARM
ACTIVATE AUX AUX1
ALARM PRIORITY LOW
BACK
ACTION TOUR
Privacy Mask ( Window Blanking)
Privacy Mask is used to protect the privacy area not to be displayed once the camera is pointed on, such asu levatory area or the operation desk of anATM machine. It might be required for video surveillance application depends on the local law regulation. The HSD Serie supports up to 24 private masks. (depends on installed camera module, please contact your local sales representative for more information)
WIND OW N UMBER :
EDIT WINDOW:
the keyboard. presse IRIS-OPEN to save.
ENABLE WINDOW:
CLEAR WINDOW:
Mask number
Edit position of the mask by joystick of
shows the mask on screen OFF
Delete the mask
Alarms
RESUME: Continue the function on the camera , if it
was setting before the alarms.
RESET DELAY: How long the camera stay in Alarm position.
ALARM CONTACT: Setting between N/C (normal Close) or N/O (normal Open).
ALARM NUMBER: curent Alarm number.
EXIT
ALARM ACTION: Setting for PRESET, SCAN, TOUR,
ARM SETTING
DAY SUN
ARM STATE OFF ARM TIME N /A UNARM TIME N/A
BACK
PAT 1-4, or NONE, if the camere in Alarm position.
ACTIVATE AUX:
activate. Select between AUX1, AUX2 (not connected) or BOTH.
ALARM PRIORITY:
Setting Alarm Output, when Alarm is
define the priority of the alarm input.
EXIT
ARM SETTING: define the operation timer of the alarm
Some products may not be available in your country, please contact our distributor for more details
ENGLISH
18
Page 12
7. Dome Address & Protocol
Protocol setting
In order to establish a connection for telemetric control with keyboard device. you need to setup the dome address and protocol.
The HSD series are capable with multiple communication protocol. The setting can be ch ange d thr ough t he DI P-S witc hes o n the re ar side of the connector boards as Illustrated.
Sw1 Sw2
SW 1:
represent the domes address in binary form.
please refer to the list on next page for reference.
SW 2:
Used for protocol settting and baud rate.
DIP 1 to 6 : Protocol setting DIP 7 and 8: Baud rate setting
Baud rate
DIP 7 DIP8
pl ease u se th e foll owi ng tab le fo r deta ils s e tup .
current pattern.
2400 bps 0 0
4800 bps 1 0
9600 bps 0 1
19200 bps 1 1
ENGLISH
Protocol / DIP 1 2 3 4 5 6
VIDO B02 0 0 1 1 0 0
DIAMOND 1 0 0 1 0 0
HUNDA 1 0 1 1 0 0
KALATEL 0 1 0 1 0 0
LILIN 1 1 0 1 0 0
MOLYNX 0 0 1 0 0 0
PANASONIC 1 1 1 0 0 0
PELCO (D/P) 1 0 0 0 0 0
PHILIPS 0 0 0 0 0 1
SAE 0 1 0 0 0 0
SAMSUNG 0 0 0 1 0 0
SANTACHI 0 1 1 0 0 0
UNIVISION 0 1 0 0 0 1
VCL 1 1 0 0 0 0
VICON 1 0 1 0 0 0
19
Some products may not be available in your country, please contact our distributor for more details
AD 1 0 0 0 0 1
Page 13
7. Address ID, 1 to 67
7.Address ID, 68 to 135
ID
1 1 0 0 0 0 0 0 0 35 1 1 0 0 0 1 0 0 2 0 1 0 0 0 0 0 0 36 0 0 1 0 0 1 0 0 3 1 1 0 0 0 0 0 0 37 1 0 1 0 0 1 0 0 4 0 0 1 0 0 0 0 0 38 0 1 1 0 0 1 0 0 5 1 0 1 0 0 0 0 0 39 1 1 1 0 0 1 0 0 6 0 1 1 0 0 0 0 0 40 0 0 0 1 0 1 0 0 7 1 1 1 0 0 0 0 0 41 1 0 0 1 0 1 0 0 8 0 0 0 1 0 0 0 0 42 0 1 0 1 0 1 0 0
9 1 0 0 1 0 0 0 0 43 1 1 0 1 0 1 0 0 10 0 1 0 1 0 0 0 0 4 4 0 0 1 1 0 1 0 0 11 1 1 0 1 0 0 0 0 4 5 1 0 1 1 0 1 0 0 12 0 0 1 1 0 0 0 0 4 6 0 1 1 1 0 1 0 0 13 1 0 1 1 0 0 0 0 4 7 1 1 1 1 0 1 0 0 14 0 1 1 1 0 0 0 0 4 8 0 0 0 0 1 1 0 0 15 1 1 1 1 0 0 0 0 4 9 1 0 0 0 1 1 0 0 16 0 0 0 0 1 0 0 0 5 0 0 1 0 0 1 1 0 0 17 1 0 0 0 1 0 0 0 5 1 1 1 0 0 1 1 0 0 18 0 1 0 0 1 0 0 0 5 2 0 0 1 0 1 1 0 0 19 1 1 0 0 1 0 0 0 5 3 1 0 1 0 1 1 0 0 20 0 0 1 0 1 0 0 0 5 4 0 1 1 0 1 1 0 0 21 1 0 1 0 1 0 0 0 5 5 1 1 1 0 1 1 0 0
22
23 1 1 1 0 1 0 0 0 5 7 1 0 0 1 1 1 0 0 24 0 0 0 1 1 0 0 0 5 8 0 1 0 1 1 1 0 0 25 1 0 0 1 1 0 0 0 5 9 1 1 0 1 1 1 0 0 26 0 1 0 1 1 0 0 0 6 0 0 0 1 1 1 1 0 0 27 1 1 0 1 1 0 0 0 6 1 1 0 1 1 1 1 0 0 28 0 0 1 1 1 0 0 0 6 2 0 1 1 1 1 1 0 0 29 1 0 1 1 1 0 0 0 6 3 1 1 1 1 1 1 0 0 30 0 1 1 1 1 0 0 0 6 4 0 0 0 0 0 0 1 0 31 1 1 1 1 1 0 0 0 6 5 1 0 0 0 0 0 1 0 32 0 0 0 0 0 1 0 0 6 6 0 1 0 0 0 0 1 0 33 1 0 0 0 0 1 0 0 6 7 1 1 0 0 0 0 1 0
Switchnumber (Sw1)
Bi t 1 2 3 4 5 6 7 8
00 000000
0 1 1 0 1 0 0 0 5 6 0 0 0 1 1 1 0 0
Switchnumber (Sw1)
ID
Bi t 1 2 3 4 5 6 7 8
0 1 0 0 0 1 0 034
ID ID
68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88
89 90 91 92 93 94 95 96 97 98 99 100 101
Bi t 1 2 3 4 5 6 7 8
0 0 1 0 0 0 1 0 1 0 1 0 0 0 1 0 0 1 1 0 0 0 1 0 1 1 1 0 0 0 1 0 0 0 0 1 0 0 1 0 1 0 0 1 0 0 1 0 0 1 0 1 0 0 1 0 1 1 0 1 0 0 1 0 0 0 1 1 0 0 1 0 1 0 1 1 0 0 1 0 0 1 1 1 0 0 1 0
1 1 1 1 0 0 1 0 0 0 0 0 1 0 1 0 1 0 0 0 1 0 1 0 0 1 0 0 1 0 1 0 1 1 0 0 1 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 0 1 1 1 0 1 0 1 0 0 0 0 1 1 0 1 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 1 0 1 1 0 1 1 0 1 0 0 0 1 1 1 0 1 0 1 0 1 1 1 0 1 0 0 1 1 1 1 0 1 0 1 1 1 1 1 0 1 0 0 0 0 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 0 0 1 1 0 1 1 0 0 0 1 1 0 0 0 1 0 0 1 1 0 1 0 1 0 0 1 1 0
102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135
Switchnumber (Sw1)
Switchnumber (Sw1)
Bi t 1 2 3 4 5 6 7 8
0 1 1 0 0 1 1 0 1 1 1 0 0 1 1 0
0 0 0 1 0 1 1 0 1 0 0 1 0 1 1 0 0 1 0 1 0 1 1 0
1 1 0 1 0 1 1 0 0 0 1 1 0 1 1 0 1 0 1 1 0 1 1 0 0 1 1 1 0 1 1 0 1 1 1 1 0 1 1 0
0 0 0 0 1 1 1 0
1 0 0 0 1 1 1 0 0 1 0 0 1 1 1 0 1 1 0 0 1 1 1 0 0 0 1 0 1 1 1 0 1 0 1 0 1 1 1 0 0 1 1 0 1 1 1 0 1 1 1 0 1 1 1 0 0 0 0 1 1 1 1 0 1 0 0 1 1 1 1 0 0 1 0 1 1 1 1 0 1 1 0 1 1 1 1 0 0 0 1 1 1 1 1 0 1 0 1 1 1 1 1 0 0 1 1 1 1 1 1 0 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 1 0 1 0 0 0 0 0 1 1 1 0 0 0 0 0 1 0 0 1 0 0 0 0 1 1 0 1 0 0 0 0 1 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1
Page 14
7. Address ID, 136 to 203
7. Address ID, 204 to 255
ID
136 137 138 139 140 141 142
143
144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168
169
Switchnumber (Sw1)
Bi t 1 2 3 4 5 6 7 8 Bi t 1 2 3 4 5 6 7 8
0 0 0 1 0 0 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 0 0 1 1 1 0 1 0 0 0 1
0 0 1 1 0 0 0 1 1 0 1 1 0 0 0 1 0 1 1 1 0 0 0 1 1 1 1 1 0 0 0 1
0 0 0 0 1 0 0 1 1 0 0 0 1 0 0 1 0 1 0 0 1 0 0 1 1 1 0 0 1 0 0 1 0 0 1 0 1 0 0 1 1 0 1 0 1 0 0 1 0 1 1 0 1 0 0 1 1 1 1 0 1 0 0 1 0 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 0 1 0 1 1 0 0 1 1 1 0 1 1 0 0 1 0 0 1 1 1 0 0 1 1 0 1 1 1 0 0 1 0 1 1 1 1 0 0 1 1 1 1 1 1 0 0 1 0 0 0 0 0 1 0 1 1 0 0 0 0 1 0 1 0 1 0 0 0 1 0 1 1 1 0 0 0 1 0 1 0 0 1 0 0 1 0 1 1 0 1 0 0 1 0 1 0 1 1 0 0 1 0 1 1 1 1 0 0 1 0 1 0 0 0 1 0 1 0 1 1 0 0 1 0 1 0 1
ID
170 171 172 173 174
175
176
177
178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202
203
Switchnumber (Sw1)
0 1 0 1 0 1 0 1 1 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 0 1 1 0 1 0 1 0 1 1 1 0 1 0 1 1 1 1 1 0 1 0 1 0 0 0 0 1 1 0 1 1 0 0 0 1 1 0 1 0 1 0 0 1 1 0 1 1 1 0 0 1 1 0 1 0 0 1 0 1 1 0 1 1 0 1 0 1 1 0 1 0 1 1 0 1 1 0 1 1 1 1 0 1 1 0 1 0 0 0 1 1 1 0 1 1 0 0 1 1 1 0 1 0 1 0 1 1 1 0 1 1 1 0 1 1 1 0 1 0 0 1 1 1 1 0 1
1 0 1 1 1 1 0 1 0 1 1 1 1 1 0 1 1 1 1 1 1 1 0 1 0 0 0 0 0 0 1 1 1 0 0 0 0 0 1 1 0 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 0 0 1 0 0 0 1 1 1 0 1 0 0 0 1 1 0 1 1 0 0 0 1 1
1 1 1 0 0 0 1 1 0 0 0 1 0 0 1 1 1 0 0 1 0 0 1 1 0 1 0 1 0 0 1 1 1 1 0 1 0 0 1 1
ID
204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237
Switchnumber (Sw1)
(Bit)1 2 3 4 5 6 7 8
0 0 1 1 0 0 1 1 1 0 1 1 0 0 1 1
0 1 1 1 0 0 1 1 1 1 1 1 0 0 1 1 0 0 0 0 1 0 1 1 1 0 0 0 1 0 1 1 0 1 0 0 1 0 1 1 1 1 0 0 1 0 1 1 0 0 1 0 1 0 1 1 1 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 1 1 0 1 0 1 1 0 0 0 1 1 0 1 1 1 0 0 1 1 0 1 1 0 1 0 1 1 0 1 1 1 1 0 1 1 0 1 1 0 0 1 1 1 0 1 1 1 0 1 1 1 0 1 1 0 1 1 1 1 0 1 1 1 1 1 1 1 0 1 1 0 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 0 1 0 0 0 1 1 1 1 1 0 0 0 1 1 1 0 0 1 0 0 1 1 1 1 0 1 0 0 1 1 1 0 1 1 0 0 1 1 1 1 1 1 0 0 1 1 1 0 0 0 1 0 1 1 1 1 0 0 1 0 1 1 1 0 1 0 1 0 1 1 1 1 1 0 1 0 1 1 1 0 0 1 1 0 1 1 1 1 0 1 1 0 1 1 1
ID
238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
Switchnumber (Sw1)
(Bit)1 2 3 4 5 6 7 8
0 1 1 1 0 1 1 1 1 1 1 1 0 1 1 1 0 0 0 0 1 1 1 1 1 0 0 0 1 1 1 1 0 1 0 0 1 1 1 1 1 1 0 0 1 1 1 1 0 0 1 0 1 1 1 1 1 0 1 0 1 1 1 1 0 1 1 0 1 1 1 1 1 1 1 0 1 1 1 1 0 0 0 1 1 1 1 1 1 0 0 1 1 1 1 1 0 1 0 1 1 1 1 1 1 1 0 1 1 1 1 1 0 0 1 1 1 1 1 1 1 0 1 1 1 1 1 1 0 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
Page 15
Call these preset numbers to change the resolu�on of the PTZ. you must call the preset twice in order to change the resolu�on or Power down and power back up twice.
Preset Resolu�on
Loading...