COP-USA CD55NV-IR35YK User Manual

Page 1
Table of Contents
Precautions
1
Features
2
Technical Data
8
Installation Guide 9
Operation Instructions 16
After- sales service 51
APPENDIX 52
……………………………………………………....…...…...
……………………………………………………....…...…...…....
……………………………………………………....…...
……………………………………………………....
…………………………………………………....….....
……………………………………………..
..……………………………………………………....…...…..
…………………………………………………….
Table of Contents
Page 2
IR Speed Dome Operating Manual
Precaution
*Please read this manual carefully before the installations and operations.
Transportation Security
No heavy stress, violent vibration or water splash are allowed during transportation, storage. The unit should be transported in separated packing. In shipments of distributor and delivery of maintenance, any damages caused by integral packing are not covered by warranty.
Installation
Avoid heavy stress and violent vibration during installation. Don’t touch the dome cover directly by hand. When connecting the power source, please follow all electric safety standards and only use the power supply designated for this device. Keep the video and control signal in a decent distance from high voltage devices and cable. Don’t apply power to dome before finishing the installation.
Internal Environment
Keep metal and inflammable material away from dome body to avoid fire short circuit and damage. Please prevent all liquids material from entering the dome. If this occurs, please shut down the power and pull out the plug-in. Then please inform the technical personnel immediately.
Electrical Safety
The video image would be interfered when the dome is installed near Television, radio transmitter, voltage changer and audio amplifier.
Camera Protection
Avoid shooting very bright objects directly into the camera’s CCD (such as the sun or light fittings) and avoid fixating the camera lens on bright static object for long time, as it will cause Irreparable damage to the camera’s CCD.
Cleaning Method
Please don’t use abrasive and violent detergent to clean the dome. Please choose dry fabric and neutral detergent. And please use lens paper to clean the lens.
*Internal removing, assembly, repair and operations should be only performed by qualified service personnel.
Please use our production under the following environmental standards:
Environmental Temperature:
Environmental Humidity:
-35 60 <95
Barometric Pressure:
Power Supply: DC12V/4A
86106KPa
1
Page 3
IR Speed Dome Operating Manual
Features
Main Features
• Stepless speed changes, auto zoom/speed matching
• Pan 0.01~360o/S, Tilt 0.01o~120o/S, Preset: 360o/S (high speed IR speed dome)
• Pan 0.5o~35o, Tilt 0.5o~35o, Preset:35o/s (for Vari-speed IR dome)
• Auto object track with zoom in/out and motion detection (Auto Track Model)
• Timing actions for 7 days of programmable schedule
• Built-in Semi-conductor heater & digital temperature sensor
• PWM cooling fan vari-speed temperature control
• Reserved network interface and space for network module
• Pan Tilt accuracy +/- 0.1o, 256preset positions
• 8 cruising tracks, each cruising track has 32 presets
• 4 pattern tours,10 Mins memory, 500 programmable instructions
• Multi-Protocol through RS485 or coaxial cable.
• 8 auto scan with use-defined left and right boundaries and settable scan speed
• 8 Privacy Zones with defined English camera title
• Auto Compatible PELCO_P, PELCO_D compatible
• Guard Location: the dome will rotate back to preset position after a period of vacant time
• Alarm triggering: the alarm can trigger preset, auto scan, cruising and pattern tours functions
• Soft Address Function: the use can set up the dome address without uninstall the dome
Integrated Super Speed PTZ Rotator
• Delicate stepping motor, stable, sensitive and accurate
• 360° Pan and 90° Tilt range (auto-flip) without blind area
• Stepless speed change, auto zoom/speed matching
• Near / far IR Light auto matches camera zoom in/out
Built-in High Definition Day/Night Camera
• Auto iris, auto back light compensation
• Auto/manual white balance
• Auto/manual brightness control
• Auto/manual focus
• Multiple compatible camera brands including Sony, Samsung, LG, CNB, Sanyo etc.
All-weather Outdoor Design
6 Inch High die-cast alloy aluminum construction
• High Precision Mould with high heat conductivity
• Fully enclosed isolation design for heat sink
• Nanometer Dustproof, waterproof and fog-proof lens
2
Page 4
IR Speed Dome Operating Manual
• IP66 Waterproof
• 3000V lightning and surge current protection
Function Instructions
• Focus / PTZ Speed Auto Match
The pan/tilt rotation speed could be automatically adjusted according to the focus in/out, which makes it much more practical for manual target tracking. (Only for the auto tracking IR speed dome)
Auto Flip
When the camera tilts downward and goes just beyond the vertical position, the camera will rotate 180 degrees.
Preset Position Set up and Call Up
In the Preset function the dome stores the current pan/tilt angle, zoom and other position parameters in its memory. When necessary the dome recalls these parameters and adjusts the camera to a particular position. The user can store, recall and clear the presets easily and promptly by using the keyboard controller. The dome can store up to 220 presets.
Auto Scan
Users can set up the left and right boundaries by control keyboard. Then speed dome can scan between this boundary. It supports up to 8 groups of scanning paths.
Cruising Track
The preset position can be programmed to be recalled in a set of sequences. This sequence can be set to let the camera scan from one position to the next in a cycle at a set speed. This feature is called the “auto cruise”. The cruise sequence and dwell time of each preset can be set. It supports up to 8cruising tracks, each cruising track with 32 presets.
Pattern Tour
Dome can memorize 600S running path or 500 programmable instructions. When start pattern tour, speed dome will move automatically according recorded action path. It supports 4 groups of pattern tours.
Guard Location
The dome automatically return to preset position if there is no operation in period of vacant time.
Default Action
When you start up the dome camera or do not send commands over a long time, the dome camera will return to its default functions which include the home place, auto pan, auto cruise and pattern.
3
Page 5
IR Speed Dome Operating Manual
1) Zoom Control
2) Focus Control
3) Auto Iris Control
4) Auto Back Light Compensation
Dome Address Setup
The dome supports up to 256 addresses and the dome will only response to the instructions given to its own address. Please check the dip switch on the bottom of the dome for address setup.
Manual Object Tracking
The use can move the joystick up, down, left or right to track the appearing object in the screen and use the joystick to zoom in and out with auto focus.
Privacy Mask Protection
Set black mask areas to protect the privacy zones. The black privacy locations can be set, and support up to 8 mask zones.
Timing Running Function
Users can set speed dome operation task at total 8 timing areas during 7 days.
Coordinates and Directions Display
User can define the dome’s direction of due north, which will help to show up the exact moving directions on screen. And zone title is supported to display when the dome moves to the specified zone.
Auto Tracking
The dome will automatically fix and track the moving object according to the user’s setup via OSD.
Motion Detection
The dome will detect the changes in the defined video zone and trigger alarm. It supports to 8 video Locations, each with 4 detection zones.
PTZ and Lens Control
Users can control zoom by keyboard to get near or far images.
The default setting is auto focus. The camera will auto focus based on the center of the video display to get the clear image. In some special occasions, the user could do the manual focus to get the desired image effect.
Auto Iris is aiming to detect the environmental lights condition and adjust the iris to get the
stabilized brightness of the image.
In the highly bright background, auto back light compensation is aiming to compensate the brightness of the dark object and adjust the background brightness to get a clear image.
4
Page 6
IR Speed Dome Operating Manual
5) Auto/Manual White Balance
6) Day and Night Switch (Only for Day/Nigh Camera)
7) OSD Setup (Only for camera with menu)
Auto/Manual WB adjust depending on the environment light changes.
Speed dome camera can auto switch according to the environmental illumination changes.
Call upon preset No.95 to enter into OSD menu setup interface. Press “Focus” to choose menu
items and press “Iris” to set menu contents.
5
Page 7
IR Speed Dome Operating Manual
Technical Specifications
Power Supply:
DC12V+10% 50W
Night IR Distance:
120/150/180meters
Manual Speed:
Pan:0.01o~360o/S, Tilt: 0.01o~120o/S (high speed) Pan:0.5o~35o/S, Tilt:0.5o~35o/S (Vair-speed)
Preset Speed:
360o/S (high speed) / 35o/S (Vari-speed)
Pan Angle:
360ocontinuous pan rotation
Tilt Angle:
90o(Auto Flip)
Number of Preset:
256
Preset Accuracy:
+0.1
o
Auto Scan:
8 auto scan tracks, user-defined left and right boundaries and scan speed
Auto Cruising:
8 cruising tracks, each cruising tracks has 32 preset positions, user-defined dwell time
Pattern Tour:
4 patterns, up to 500 instructions per pattern
Guard Location:
The dome will rotate back to preset position after a period of vacant time.
IR LED On Mode:
Manual/Auto/Timing
Data Communication:
RS-485
Protocols:
Auto Compatible PELCO_P, PELCO_D
Camera Module:
Auto Compatible SONY, LG, Samsung, CNB, HITACH, etc.
Baud Rate:
2400/4800/9600bps
Operating Humidity:
090%
Operating Temp:
-35oC +55oC
6
Page 8
IR Speed Dome Operating Manual
Installation Guide
Models Max Distance(Feet\Meter)
RG59/U 750ft(229m)
RG6/U 1,000ft(305m)
RG11/U 1,500ft(457m)
Preparations
Basic Requirements
All the electric work must be finished under the latest electric & fire prevention law and rules (and any related law and rules). Please check according to the packing list if every accessory is included. And also make sure the installation is operated as required. Please contact us for any help during the installation.
Installation Space and Density Checkup
Please make sure the space is big enough to install our dome. And also ensure the density of the ceilings or walls to hold total weight of the dome and its accessories.
Cables Preparation
Please choose the proper cable according to the transmission distance. The min requirement of coaxial BNC cable is listed as follows for reference:
Installation Method
The IR speed dome could be installed in wall-mount and pedant-mount
Installation Dimensions
7
Page 9
IR Speed Dome Operating Manual
304
297
Ø210
Dome body rack
Wiper
Dome Housing
Power adapter bracket
Protective sling
Pendant-mout
bracket
Ø210
485
220
78
100
100
125
Wall-mount
4-Ø8
Ø105
Ø105
Pendant-mout
Wall Mount
Picture01 picture02
Pendant Mount
Picture03 picture04
Installation Procedures
Notice: The wall and ceiling must be thick enough to install the expansion bolts and can bear 4 times the weight of the dome camera itself.
8
Page 10
IR Speed Dome Operating Manual
Wall-mount Installation Procedures
1) Take out the wall-mount bracket from the package , mark the installation hole positions on the wall referencing to the dimension as picture 02.
2) Drill the hole and install 4 pieces of M8 expansion bolt into the hole.
:
(
Picture 05
3) Take out the IR speed dome and put the cables through the bracket. Use M5 screws to fix the bracket and dome body, as picture 01
4) Use 4 pieces of M8 screw nuts with washer to fix the bracket on the wall.
Pendant-mount Installation Procedures
)
:
1) Take out the pendant-mount bracket from the package , mark the installation hole positions on the ceiling referencing to the dimension in picture 04.
2) Drill the hole and install 4 pieces of M8 expansion bolt into the hole, as
picture05
3) Take out the IR speed dome and put the cables through the sockets on the bottom of the pendant bracket. Use M5 screws to fix the bracket and dome body, as picture 03
9
Page 11
IR Speed Dome Operating Manual
Dome Setting
Before the dome is installed, please finish the setup of the communication
SW1Dip switch for the dome address SW2
Dip switch for
the dome protocol
4) Use screw nuts with washer to fix the bracket on the wall.
Notice: Pendant-bracket is not designed for outdoor installation. If specially required, please do make sure the waterproof installation of the dome.
protocol, baud rate and dome address. Set the DIP switch inside the dome body. The relative DIP switch site and connecting wires are diagrammed below for reference.
10
Page 12
IR Speed Dome Operating Manual
Baud Rate SW2-5 SW2-6
9600 OFF OFF 4800 ON OFF 2400 OFF ON
Reserved
Protocol Setup
Our IR speed dome supports three protocols including Pelco P, Pelco D and HS. All of them supports baud rate of 9600bps4800bps2400bps. Set the No.1~4 dip switch for the protocol configuration.
Protocol SW2-1 SW2-2 SW2-3 SW2-4
HS OFF OFF OFF OFF PELCO P ON OFF OFF OFF PELCO D OFF ON OFF OFF
Reserved
Baud Rate Setup
Set the No.5~6 dip switch for the baud rate configuration.
Dome Address Setup
PELCO-P & PELCO-D Protocol
AddSW-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
1 1 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 0 3 1 1 0 0 0 0 0 0 4 0 0 1 0 0 0 0 0 5 1 0 1 0 0 0 0 0 6 0 1 1 0 0 0 0 0 7 1 1 1 0 0 0 0 0 8 0 0 0 1 0 0 0 0
9 1 0 0 1 0 0 0 0 10 0 1 0 1 0 0 0 0 11 1 1 0 1 0 0 0 0 12 0 0 1 1 0 0 0 0 13 1 0 1 1 0 0 0 0
11
Page 13
IR Speed Dome Operating Manual
BNC Connector
Power Connector
Red:RS485A Yellow:RS485B
14 0 1 1 1 0 0 0 0 15 1 1 1 1 0 0 0 0 16 0 0 0 0 1 0 0 0 17 1 0 0 0 1 0 0 0 18 0 1 0 0 1 0 0 0 19 1 1 0 0 1 0 0 0 20 0 0 1 0 1 0 0 0 21 1 0 1 0 1 0 0 0 22 0 1 1 0 1 0 0 0 23 1 1 1 0 1 0 0 0 24 0 0 0 1 1 0 0 0 25 1 0 0 1 1 0 0 0 26 0 1 0 1 1 0 0 0 27 1 1 0 1 1 0 0 0 28 0 0 1 1 1 0 0 0 29 1 0 1 1 1 0 0 0 30 0 1 1 1 1 0 0 0 31 1 1 1 1 1 0 0 0 32 0 0 0 0 0 1 0 0
… 253 1 0 1 1 1 1 1 1 254 0 1 1 1 1 1 1 1
Cable Definition
BNC Connector :Video Coaxial Cable Power Connector: DC12V Red: RS485A
12
Page 14
IR Speed Dome Operating Manual
Yellow: RS485B
Operation Instructions
Serial
No.
1 2 3 4 5 6
Meaning Dip Switch Temperature Sensor Storage Pan Tilt Camera
Main Functions Fast Call Up
Our IR Speed dome supports 220 preset positions. You can activate some special functions by
calling upon code number 65-99.
Serial
No.
1 Start Auto Scan Call 99
2 Start Auto Cruise Call 98
3 Start Pattern Tour Call 97
4
5
6
7
8 Open OSD Menu
9 Remote Reset Call 94
Stop Auto Mode/End up
Command Fast Call Up Note
Start Auto Scan of
Group No.
Start Auto Cruise of
Group No.
Start Pattern Tour of
Group No.
Setting
Call 80+ Call pp+ Call 99
Call 80+ Call pp+ Call 98
Call 80+ Call pp+ Call 97
Call 96
Set 95or Call 95
Default to start auto scan of
group No.1
Default to start auto cruise of
group No.1
Default to start pattern tour of
group No.1
pp meansGroup No.1-8
pp meansGroup No.1-4
10 Recover Factory Default Call 82
System Self-Testing
The dome will do self-testing after power up, and system status will show “Normal” if system Is running normally. If error happens, testing result will be shown in “○” or “X”. “○” means normal and “X” means error. Please check the according meaning as follows:
13
Page 15
IR Speed Dome Operating Manual
IRIS
OPEN
IRIS
OPEN
IRIS
OPEN
OSD Menu Operations
Call Preset 95 to enter the main OSD menu (or call preset No.1 two times continuously within two seconds)
Control the joystick to move the cursor around the menu
Press “Iris Open” to enter the menu for selections
Move the joystick up and down to select the item
Press “Iris Open” to confirm the selection
Press “Iris Close” to cancel the selection
*Note: If your controller does not have a joystick, use the up or down key.
14
Page 16
IR Speed Dome Operating Manual
MAIN MENU
LANGUAGE:ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
MOTION
<PRESET> <SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING> BACK EXIT
SYETEM INFORMATION
DOME ID :1234567890 ADRESS:001 BAUDRATE:2400 PROTOCOL:PELCO-D TEMPERATURE:31
VOLTAGE:12.0V ALARM:000000 00 <OTHERS>
DISPLAY
DOME TITLE :OFF PRSEST :5 SEC MOTION :5SEC DATE/TIME :ON PAN/TILT :5 SEC <OTHERS> <DISPLAY POSITION>
BACK EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
CAMERA SETTINGS
FOCUS MODE :AUTO DIGITAL ZOOM :OFF BACKLIGHT :OFF PICTURE FLIP :OFF FREEZE :OFF ZOOM SPEED :NORMAL DAY NIGHT :AUTO <ADVANCED>
OSD Menu Description
15
Page 17
IR Speed Dome Operating Manual
The language for the on-screen menus is Selectable.
To change the display language: Press Iris Open to enter
selection.
All on-screen menus are changed to the selected
language.
CAMERA SETTINGS
FOCUS MODE :AUTO DIGITAL ZOOM :OFF BACKLIGHT :OFF PICTURE FLIP :OFF FREEZE :OFF ZOOM SPEED :NORMAL DAY NIGHT :AUTO <ADVANCED>
BACK EXIT
LANGUAGE
LANGUAGE :ENGLISH
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
LANGUAGE
16
Page 18
IR Speed Dome Operating Manual
The user can check the dome system information as
required. The system information includes: Dome ID, dome
address, baud rate, protocol, temperature, voltage, alarm
information, dome title, version, date, time, and temperature
scale.
Use the following steps to display the System
Information screens:
1) Use the joystick to position the cursor along the SYSTEM
INFORMATION.
2) Press Iris Open. The SYSTEM INFORMATION screen opens.
3) Mover the joystick up and town to select the item.
4) Press Iris Open to enter the setup of each item.
OTHERS
TITLE :DOME TITLE VERSION:V220ST DATE:2009-01-01 TIME:10:20:00 TEMP SCALE:CELSIUS
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS HELP EXIT
SYETEMINFORMATION
DOME ID :1234567890 ADDRESS:001 BAUDRATE:2400 PROTOCOL:PELCO-D TEMPERATURE:31 VOLTAGE:12.0V ALARM :000000 00 <OTHERS>
BACK EXIT
SYSTEM INFORMATION
17
Page 19
IR Speed Dome Operating Manual
Display setup allows the user to define the way to display
the dome titles on the monitor.
The displayed titles are listed as follows:
Two options for the Dome Title and Date/Time: OFF and ON
Other setup selections include:
Move the cursor by joystick to the one you need to set, and press Iris
Open to enter the item. Move the joystick select the status and press Iris
Open to confirm.
Titles can be placed anywhere on the monitor. This
feature allows you to customize the window of your monitor
screen. To set a title position:
1) Use the joystick to position the cursor in the DISPLAY POSITION
2) Press Iris Open.
3) Use the joystick to move the title up, down, left, or right.
4) Press Iris Open.
5) Repeat steps 1 through 4 to position other titles
6) Position the cursor at BACK or EXIT. Press Iris Open to save settings
and exit menu.
IR LED
The user can open and close the IR LED manually and set
up the IR LED work mode under this OSD mean. (Under normal
operation mode, the user can press IRIS OPEN and IRIS CLOSE
to adjust the IR LED power):
1) CONTROL MODE:
DOME TITLE Indicate dome PRESET Indicate the dwell time for preset title AUTO FUCTION Indicate the dwell time for auto function titles ZONES Indicate the dwell time for zone titles DATE/TIME Display the current date and time
OFF Title will not be displayed when activated
ON Title will be continuously displayed when activated 2 SEC Title will be displayed for 2seconds after activation 5 SEC Title will be displayed for 5seconds after activation
10 SEC Title will be displayed for 5seconds after activation
DISPLAY
ALARM :5 SEC IR LED INFO :5 SEC PROMPT :ON
BACK EXIT
DISPLAY POSITION
<DATE/TIME> <DOME TITLE> <ZONES> <MOTION> <ALARM> <PAN/TILT>
BACK EXIT
DISPLAY
DOME TITLE :OFF PRSEST :5 SEC MOTION :5SEC DATE/TIME :ON PAN/TILT :5 SEC <OTHERS> <DISPLAY POSITION>
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
DISPLAY
18
Page 20
IR Speed Dome Operating Manual
2) SENSITIVIRY:
Here the user can
manually set the
sensitivity from 1-5.
The smaller the
number is, the lower
light of the
environment will be
3) IR LED POWER: Here the use can choose the power mode covering: NORMAL, MATCH and USER.
4) AUTO CONTROL:When it is on, the IR LED will turn its power consumption to the standby status
5) STANDBY POWER: When the AUTO CONTROL is on, the user can set up the standby power here.
6) STANDBY DELAY: Set up how long if there is not moving object, the IR LED will turn into standby
7) SENSITIVITY: When the AUTO CONTROL is on, the user can set up the sensitivity to detect the
8) ENHANCED MODE: Under normal status, press IRIS OPEN to enhance the IR LED power, when it is
9) START/STOP TIME: Set up time for IR LED to open and close under “TIMING” of control mode.
1) Numbers : Move the cursor to “NUMBER” and press IRIS OPEN
2) Speed: Move the cursor to “SPEED” and IRIS OPEN to enter the
3) Start : Move the cursor and press IRIS OPEN to start wiper.
AUTO IR LED will be opened or closed automatically according to the
light conditions.
TIMING LED will be adjusted according to Open and Close Time. OPEN IR LED forcedly open CLOSE IR LED forcedly close CAMERA IR LED status (Open/Close) will be synchronized with Camera
day and night switching
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
DOME SETTINGS
<IR LED> <WIPER>
when the IR LED on.
NORMAL: Near IR LED will be turned on when wide angle. and Far IR LED will be turned on when
small angle.
MATCH: The Near and Far IR LED will be turned on and off automatically to match the zoom in and
out.
USER: The user can manually adjust the Near and Far IR LED.
which will effectively extend the service life of IR LEDs. And under this mode, when objects appear in the screen, the IR LED will turn its power consumption back to the normal status.
status.
moving objects.
turned to maximum, press IRIS OPEN continuously for 2 seconds to enter the enhanced mode. And the whole brightness of the image will be improved. Move the cursor to EHNANCED MODE and press IRIS to enter and select between” STATIC” and “DYNAMIC”
WIPER
The user can make adjustment for the wiper under
this menu (suitable for wiper-equipped dome)
to enter the setup of Wiper Number. Move the joystick up and down to select number (1-10),then press IRIS OPEN to confirm.
setup of Wiper speed. Move the joystick up and down to select “HIGH” ,“MID ”OR “ LOW”, the press IRIS OPEN to confirm.
19
Page 21
IR Speed Dome Operating Manual
IDLE
IDLE setting means if there is no command for the
dome for a period of time, the dome will run the actions
as defined.
1) TIME: Move the cursor to “TIME” and press IRIS OPEN to enter,
and move the joystick up and dome to select among 30 sec, 1 min,
5 min, 10 min and 30 min. And press IRIS OPEN to confirm.
2) ACTION: Move the cursor to “ACTION” and press IRIS OPEN to
enter. Move the joystick to select the actions including” NONE,
PRESET, SCAN, SEQUENCE, PATTERN. Press IRIS OPEN to confirm.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
IDLE ACTION
TIME : 30 SEC ACTION :NONE
BACK EXIT
20
Page 22
IR Speed Dome Operating Manual
ALARM
The dome system has 2alarm inputs and 1 alarm
output. (optional function). When an alarm is received, an
input signal to the dome triggers the user defined action
(such as presets, patterns, etc.), and at meantime the
alarm output signals is activated.
ALARM NO.: Move the cursor to the ALARM NO. Press IRIS OPEN to
enter and move the joystick up and down to select the alarm input
no. (Channel 1 and Channel 2)
INPUT STATE: Set the alarm contact status. There are two input
states, OPEN and CLOSE.
ALARM MODE:
ACTION: Set the alarm action:
ALARM OUT: Set the auxiliary to activate:
RESET TIME: Set up time for the alarm output (such as an alarm
buzzed) when is triggered by the detector.
START /STOP TIME: Set up the time to start alarm and stop alarm
ONLY under the AUTO mode under ALARM MODE.
OFF Alarm function is deactivated. ON Alarm function is activated. AUTO AUTO Alarm function will be activated and deactivated
between START TIME and STOP TIME.
NONE (default) No action PRESET Dome goes to preset. (Default as Preset 1) SCAN Dome starts auto scan (Default as Auto Scan 1) SEQ Dome runs auto cruise (Default as Auto Cruise 1) PATTERN Dome runs pattern (Default as Pattern 1)
OFF Not alarm output will be activated. OUT1 An alarm action will close AUX 1 output.. OUT2 An alarm action will activate AUX2 output.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
DOME SETTINGS
<IR LED> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> RESTART FACTORY DEFAULTS
BACK EXIT
ALARM SETTING
ALARM NO. :1 CONTACT :N/O INPUTSTATE :OPEN ALARM MODE :OFF ACTION :NONE ALARM OUT :OFF RESET TIME :10 SEC START TIME:00:00 STOP TIME:00:00
BACK EXIT
21
Page 23
IR Speed Dome Operating Manual
Privacy mask allows the user to mask the privacy
areas with black frame. The user can set up 8 privacy
masks at most.
MASK NO.: Move the cursor here and press IRIS OPEN to enter the
setup of Mask Number of the privacy zone.
ENABLE: To enable or disable this privacy mask function.
SET: Move the cursor here and press IRIS OPEN to enter the mode of
setting the privacy mask. Move the joystick (Left/Right/Up/Down) on
the screen to set up the privacy zone and press IRIS OPEN to
confirm.
DELETE: Move the cursor here and press IRIS OPEN to delete the
current No. of privacy mask zone.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
PRIVACY MASK
MASK NO.:01 ENABLE :START <SET> DELETE
BACK EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
PRIVACY MASK
22
Page 24
IR Speed Dome Operating Manual
The dome can display the data and time. And the user
could enter this CLOCK menu to set up the DATE and TIME.
DATE: Move the cursor here and press IRIS OPEN to enter. Move the
joystick left and right to choose the date position and move it up and
dome to adjust the figures. Press IRIS OPEN to confirm.
TIME: Move the cursor here and press IRIS OPEN to enter. Move the
joystick left and right to choose the time position and move it up and
dome to adjust the figures. Press IRIS OPEN to confirm.
SAVE/CANCEL: Move the cursor to “SAVE” and press IRIS OPEN to
save the settings. Move the cursor to “DELETE” and press IRIS OPEN
to cancel the settings.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
DATE/TIME
DATE :2009-01-01 TIME :1200
SAVE CANCEL
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
CLOCK
23
Page 25
IR Speed Dome Operating Manual
The dome features password protection function to
prevent unauthorized changes to the dome settings. If
the PASSWORD function is enabled, the operator can not
access any dome setting without entering a valid
password.
EDIT PASSWORD: Move the cursor here and press IRIS OPEN to
enter. Please under the old password before set up the new
password. The initial password is “111111”
ENABLE: Move the cursor here and press IRIS OPEN to enter.
Move the joystick to select between “ON” and “OFF” . The user
need to enter the password when opening the OSD under the
status of “ENABLE: ON”.
MAIN MENU
LANGUAGE:ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
PASSWORD
EDIT PASSWORD :****** PASSWORD PROTECT :OFF
BACK EXIT
DOME SETTINGS
<IR LED> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
PASSWORD
24
Page 26
IR Speed Dome Operating Manual
The user can set up the dome title to define each camera.
Dome title support up to 12 characters.
Move the cursor according the left steps and select INPUT.
Press IRIS OPEN to enter.
1) Move the joystick left and right to position “←”, and press IRIS OPEN
to delete the character at“←”.
2) Press IRIS CLOSE to exit the edit mode.
3) Move the cursor to “<CAP>” and press IRIS OPEN to enter. Move the
joystick up and down to select the input method (such as English Cap,
English, Chinese, Figures, and Symbols)
4) Mover the cursor to next line of <CAP> and press IRIS OPEN to enter
the mode of character input. The selected character will be shown in
high brightness. Move the joystick up/down/left/right to choose the
needed characters. Press IRIS OPEN to move the selected character
to the INPUT position at“”.
5) After finishing the character inputs, move the cursor to “OK” and
press IRIS OPEN to confirm.
6) Also user can move the cursor to “CANCEL” to cancel the character
input settings.
OTHERS
TEMP MODE :AUTO PRESET FREEZE :OFF AUTO FLIP :ON BROADCAST :ON MENU STYLE :IMAGE STOP TIME :30 SEC MENU OFF TIME :5 MIN <DOME TITLE> <AZIMUTH ZERO> BACK EXIT
DOME TITLE TEST
INPUT: ___________ <CAPS>
ABCDEFGHIJ KLMNOPQRS TUVWXYZ.
OK CANCEL
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
DOME TITLE
25
Page 27
IR Speed Dome Operating Manual
The use can set up the SOFT ADDRESS, SOFT PROTOCOL and
SOFT BAUD RATE under this menu here to activate the soft address
function. And then the defined dome address by dip switch will be
disabled.
1) Move the cursor to INPUT (under DOME ID) and press IRIS OPEN to enter
the mode of setting dome ID, Move the joystick to position the cursor
beside :0 1 2 3 4 5 6 7 8 9” and press IRIS OPEN to enter. And move the
joystick again to select numbers of dome ID and press IRIS OPEN to confirm.
The number selected will be input on the upper line.
2) Move the cursor to INPUT (the bottom menu) and press IRIS OPEN to enter
the mode of setting soft address, Move the joystick to position the cursor
beside :0 1 2 3 4 5 6 7 8 9” and press IRIS OPEN to enter. And move the
joystick again to select numbers of dome soft address and press IRIS OPEN
to confirm. The number selected will be input on the upper line.
3) Enable or disable the soft address function. Press IRIS CLOSE to exit last
step. Move the cursor to to “SOFT ADDRESS:ON/OFF”. Press iris open to
enter. Move the joystick up or down to select ON of OFF. Press IRIS OPEN
to confirm.
4) Press OK to save and confirm all the settings and press CANCEL to exit all
the settings.
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
ADVANCED
<SOFT SETTING> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST>
BACK EXIT
SOFT SETTING
<SOFT ADDRESS SET> SOFT PROTOCOL :OFF SOFT BAUD RETE :OFF
BACK EXIT
DOME SOFT ADDRESS SET
SOFT ADDRESS :001 INPUT ID :(000-255) INPUT : ________
0 1 2 3 4 5 6 7 8 9
SOFT ADDRESS :OFF
OK CANCEL
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
SOFT ADDRESS SET
26
Page 28
IR Speed Dome Operating Manual
The user can set up the auxiliary output to trigger other
devices from an alarm or a controller.
Move the cursor to AUX and press IRIS OPEN to enter to
select “ON” or “OFF” to enable or disable this function.
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
ADVANCED
<SOFT SETTIG> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST>
BACK EXIT
AUX
AUX1 :OFF AUX1 :OFF
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
AUX
27
Page 29
IR Speed Dome Operating Manual
The user can set up the soft limit to define the left and
right boundaries for the pan movement.
SOFT LIMIT: Move the cursor here and press IRIS OPEN to enter.
Move the joystick to select “ON” or “OFF” to enable or disable this
function.
LEFT LIMIT: Move the cursor here and press IRIS OPEN to enter.
Now the user can mover the joystick to control the PAN movement of
the dome to a defined position for the left limit. Press IRIS OPEN to
confirm.
RIGHT LIMIT: Move the cursor here and press IRIS OPEN to enter.
Now the user can mover the joystick to control the PAN movement of
the dome to a defined position for the right limit. Press IRIS OPEN to
confirm.
LIMIT DELETE:
Move the cursor here and press IRIS OPEN to
delete all the settings.
ADVANCED
<SOFT SETTIG> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTON> <CAMERA> <COMMUNICATION TEST>
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT
DOME SETTINGS <IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
LIMIT SETTING
SOFT LIMIT :OFF <LEFT LIMIT> <RIGHT LIMIT> LIMIT DELETE
BACK EXIT
SOFT LIMIT
28
Page 30
IR Speed Dome Operating Manual
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS HELP EXIT
ADVENCED
<SOFT SETTING> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST> <TILTANGLE> <DOME VIDEO> BACK EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
DOME SPEED SETTING
DOME SPEED :180°/S
BACK EXIT
DOME SPEED
can enter this menu to set up. Move the cursor to DOME SPEED and press IRIS OPEN to enter. Move the joystick to select the dome speed when doing the pan movement. Move the cursor to BACK/EXIT and press IRIS OPEN to run the command of BACK or EXIT.
To make a selection of the dome speed, the user
29
Page 31
IR Speed Dome Operating Manual
NONE (default) No action PRESET Dome goes to preset. (Default as Preset 1) SCAN Dome starts auto scan (Default as Auto Scan 1) SEQ Dome runs auto cruise (Default as Auto Cruise 1) PATTERN Dome runs pattern (Default as Pattern 1)
DOME SETTINGS
<IR LED> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
POWER ON ACTION
POWER ON ACTION :NONE
BACK EXIT
ADVANCED
<SOFT SETTIG> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST> <TILTANGLE> <DOME VIDEO>
BACK EXIT
POWER ON ACTION
on, Move the cursor to POWER ON ACTION and press IRIS OPEN to enter the mode of setup.
The user can define the dome action when power
30
Page 32
IR Speed Dome Operating Manual
The dome can automatically recognize the main
camera modules in the market. For the cameras it can not
recognize, the user can set up here.
CAMERA: Move the cursor here and press IRIS OPEN to enter the
setup mode. Move the joystick up and down to select the camera
types. Press IRIS OPEN to confirm.
BAUDRATE: Move the cursor here and press IRIS OPEN to enter the
setup mode. Move the joystick up and down to select the baud rate.
Press IRIS OPEN to confirm.
PARITY: Move the cursor here and press IRIS OPEN to enter the
setup mode. Move the joystick up and down to select the parity mode.
Press IRIS OPEN to confirm.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS HELP EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS>
BACK EXIT
ADVANCED
<SOFT ADDRESS SET> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST> <TILTANGLE> <DOME VIDEO>
BACK EXIT
CAMERA
CAMERA :AUTO BAUDRATE :9600 PARITY :NONE
BACK EXIT
CAMERA SETTINGS
31
Page 33
IR Speed Dome Operating Manual
The dome can do self-diagnosis for the
communications between keyboard and speed dome. The
test needs to match with our software VK200.
If the self-testing is successfully finished via the software ,
the system will show up the testing result as left diagram.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS HELP EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
ADVANCED
< SOFT ADDRESS SET> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST> <TILT ANGLE> <DOME VIDEO> BACK EXIT
COMMUNICATION TEST
KEYBOARD->DOME :100/100 KEYBOARD<-DOME :100/100 DOME RECEIVE :100% KEYBOARD RECEIVE :100%
BACK EXIT
COMMUNICATION TEST
32
Page 34
IR Speed Dome Operating Manual
The user can set up the tilt angle under the menu of
TILT ANGLE.
Move the cursor to “TILT ANGLE” and press IRIS OPEN to
the setup of tilt angle . Move the joystick up and down to
select the angle and press the IRIS OPEN to confirm.
TILTANGLE SETTINGS
TILTANGLE :-5
BACK EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
ADVANCED
< SOFT ADDRESS SET> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST> <TILT ANGLE> <DOME VIDEO> BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS HELP EXIT
•TILT ANGLE
33
Page 35
IR Speed Dome Operating Manual
COMMUNICATION TEST
KEYBOARD->DOME:100/100 KEYBOARD<-DOME:100/100 DOME RECEIVE:100% KEYBOARD RECEIVE:100%
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS HELP EXIT
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
ADVANCED
< SOFT ADDRESS SET> <AUX> <SOFT LIMIT> <DOME SPEED> <POWER ON ACTION> <CAMERA> <COMMUNICATION TEST> <TILTANGLE> <DOME VIDEO> BACK EXIT
•DOME VIDEO
in module. The user set as follows: Move the cursor to “DOME VIDEO”, press IRIS OPEN to the setting mode. Move the joystick up and down to select “PAL” or “NTSC”, press the IRIS OPEN to confirm.
The dome can also output video signal without build-
34
Page 36
IR Speed Dome Operating Manual
The user can set up TEMP MODE, INTERNAL FAN, PRESET FREEZE,
STOP TIME. MENU OFF TIME and NORTH ZERO here under the menu of
“OTHERS”
TEMP MODE: To set up the control mode of dome fans and heaters. It
includes three modes of AUTO, FAN HIGH SPEED and FAN LOW SPEED.
PRESET FREEZE: This feature freezes the scene on the monitor when
going to a preset. This allows smooth switching from one preset scene
to another.
AUTO FLIP: When the camera tilts downward and goes just beyond
the vertical position, the camera will rotate 180 degrees. The user can
press IRIS OPEN to enter and choose to turn on/off this function.
STOP TIME: To set up the time that dome will stops after receiving
the last command. Options include 5/15/30/60 Sec.
MENU OFF TIME: To set up the time that OSD menu be off when no
operations. Options include 1/2/5/10 min.
NORTH ZERO: To set up the due north of the dome (pan 0º)
Move the cursor here and press IRIS OPEN to enter. Move the joystick
to control the dome to pan 0º and press IRIS OPEN to confirm.
DOME SETTINGS
<IR LED> <WIPER> <IDLE> <ALARM> <PRIVACY MASK> <CLOCK> <PASSWORD> <ADVANCED> <OTHERS> BACK EXIT
OTHERS
TEMP MODE :AUTO PRESET FREEZE :OFF AUTO FLIP :ON BROADCAST :ON MENU STYLE :IMAGE STOP TIME:30 SEC MENU OFF TIME :5 MIN <DOME TITLE> <AZIMUTH ZERO>
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS HELP EXIT
OTHERS
35
Page 37
IR Speed Dome Operating Manual
The user can make adjustment for the cameras
under this menu.
FOCUS MODE: AUTO FOCUS allows the camera lens to remain in
focus during zooming in, zooming out and pan/tilt movement.
Move the cursor here and press IRIS OPEN to enter. Setup the
mode: AUTO” or “OFF” and press IRIS OPEN to confirm. When auto
focus is off, the user needs to do manual focus.
DIGITAL ZOOM: Move the cursor here and press IRIS OPEN to
enter. Setup the function to be “ON” or “OFF”.
BACKLIGHT: Move the cursor here and press IRIS OPEN to enter.
Setup the function to be “ON” or “OFF”.
PICTURE FLIP: To set up the Tilt flip for the dome. Move the
cursor here and press IRIS OPEN to enter. Setup the function to be
“ON” or “OFF”.
FREEZE: If turn on this function, the screen image will be frozen
until it is turned off. Move the cursor here and press IRIS OPEN to
enter. Setup the function to be “ON” or “OFF”.
ZOOM SPEED: To set up the zoom speed of Low, Normal and high
when doing the zoom in and out. Move the cursor here and press
IRIS OPEN to enter. Move the joystick to choose and press IRIS
OPEN to confirm
DAY NIGHT:
To set up the day and night mode of AUTO, CLOUR
and B/W. Move the cursor here and press IRIS OPEN to enter. Move
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS
HELP EXIT
CAMERA SETTINGS
FOCUS MODE :AUTO DIGITAL ZOOM :OFF BACKLIGHT :OFF PICTURE FLIP :OFF FREEZE :OFF ZOOM SPEED :NORMAL DAY NIGHT :AUTO <ADVANCED>
BACK EXIT
CAMERA
the joystick to choose and press IRIS OPEN to confirm
36
Page 38
IR Speed Dome Operating Manual
The use can set up more detailed parameters of
camera here under the menu of CAMERA ADVANCED.
WB: To set up the white balance of the camera. Options include
AUTO, MANUAL. INDOOR and OUTDOOR. The use can select
different mode according the different locations.
RED GAIN: Only can be adjusted whet WB set as manual.
BLUE GAIN: Only can be adjusted whet WB set as manual.
BIRGHT: To set up the brightness of the image. Move the cursor
here and press IRIS OPEN to enter. Move the joystick to adjust and
press IRIS OPEN to confirm
EXPOSURE: To set up the exposure mode of the camera. Options
include AUTO, MANUAL, SHUTTER PRIORITY, IRIS PRIORITY and
BRIGHT PRIORITY. The use can select different mode according the
different locations.
WIDE DYNAMIC: Wide dynamic range (WDR) balances the
brightest and darkest sections of a scene to produce a picture that
is perfectly balanced in light and clarity. Available settings are
OFF.LOW.MID and HIGH. The default setting is OFF.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS
HELP EXIT
ADVANCED
WB :AUTO RED GAIN :208 BLUE GAIN :167 BRIGHT :01 EXPOSURE :AUTO WIDE DYNAMIC :OFF
BACK EXIT
CAMERA SETTING
FOCUS MODE :AUTO DIGITAL ZOOM :OFF BACKLIGHT :OFF PICTURE FLIP :OFF FREEZE :OFF ZOOM SPEED :NORMAL DAY NIGHT :AUTO <ADVANCED>
BACK EXIT
CAMERA ADVANCED
37
Page 39
IR Speed Dome Operating Manual
The dome supports 220 presets. Please check the
following steps to set up a preset.
1) PRESET NO.: Move the cursor here and press IRIS OPEN to
enter the setup of Preset Number. Move the joystick to select a
preset number (1-64 and 100-255) and press IRIS OPEN to
confirm.
2) TITLE: Move the cursor here and press IRIS OPEN to enter the
setup of Preset Title. Check the detailed above in DOME TITLE
settings.
3)
<SET>:
Move the cursor here and press IRIS OPEN to enter.
Move the dome to a defined position as preset point and press
IRIS OPEN to save the preset position.
4)
CALL:
Move the cursor here and press IRIS OPEN to call up the
current preset.
5)
DELETE:
Move the cursor here and press IRIS OPEN to delete
the current preset.
6)
SPEED:
Move the cursor here and press IRIS OPEN to set up the
preset call up speed of LOW, MID and HIGH.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS
HELP EXIT
MOTION
<PRESET> <SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING>
BACK EXIT
PRESET
PRESET NO. :<001> TITLE :PRESET :- - - - - ­CALL <SET> DELETE SPEED :HIGH
BACK EXIT
PRESET
38
Page 40
IR Speed Dome Operating Manual
The dome supports 8 groups of auto scan. Please check
the following steps to set up a scan.
1) SCAN NO.: Move the cursor here and press IRIS OPEN to enter the
setup of SCAN Number. Move the joystick to select a preset number
(1-8) and press IRIS OPEN to confirm.
2)
TITLE:
Move the cursor here and press IRIS OPEN to enter the
setup of SCAN Title. Check the detailed above in DOME TITLE
settings.
3)
<LEFT LIMIT>:
Move the cursor here and press IRIS OPEN to
enter. Move the dome to a defined position as left limit and press
IRIS OPEN to save this left boundary.
4) <RIGHT LIMIT>: Move the cursor here and press IRIS OPEN to
enter. Move the dome to a defined position as right limit and press
IRIS OPEN to save this right boundary.
5) START: Move the cursor here and press IRIS OPEN to start the
current scan.
6) SCAN SPEED: Move the cursor here and press IRIS OPEN to set up
the scan speed ranging 1-30.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFUALTS
HELP EXIT
MOTION
<PRESET> <SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING>
BACK EXIT
SCAN
SCAN NO. :1 TITLE :SCAN 1 START <LEFT LIMIT> <RIGHT LIMIT> SCAN SPEED :20
BACK EXIT
AUTO SCAN
39
Page 41
IR Speed Dome Operating Manual
The dome supports 8 groups of auto cruise and each
cruise supports 32 presets. . Please check the following
steps to set up cruise.
1) SEQ NO.: Move the cursor here and press IRIS OPEN to enter
the setup of Sequence Number. Move the joystick to select a
preset number (1-8) and press IRIS OPEN to confirm.
2) TITLE: Move the cursor here and press IRIS OPEN to enter the
setup of Sequence Title. Check the detailed above in DOME TITLE
Settings.
3)
<SEQUENCE SET>:
Move the cursor here and press IRIS OPEN
to enter. Move the cursor to EDIT and press IRIS OPEN enter
edit mode of sequence. Move the joystick left and right to
select each item.
a) When the < > is on the item NO., move joystick up or down
to select the Serial NO. of the preset in a sequence. There
are up to 32 presets in each sequence.
b) When the < > is on the item PRESET, move the joystick up or
down to select the preset NO. that the user wants to add in
the sequence.
c) When the < > is on the INTERVAL, move the joystick up or
down to select the interval time between each preset.
d) When the < > is on the last item, move the joystick up or
down to select edition mode as “INS (insert)”, “ok” and
“delete”.
Press IRIS OPEN when selecting INS to insert the settings into
the position of current Serial No.
Press IRIS OPEN when selecting OK to override the settings of
Current Serial No.
Press IRIS OPEN when selecting delete to delete the settings
of the Current Serial No.
Press IRIS OPEN to save all the setting and press IRIS CLOSE
to exit.
4) DELETE/START: Move the cursor here and press IRIS OPEN to
delete/start the current sequence.
MAIN MENU
LANGUAGE :ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT
MOTION
<PRESET>
<SCAN>
<SEQUENCE>
<PATTERN>
<ZONES>
<TIMING ACTION>
<MOTION DETECT>
<AUTO TRACKING>
BACK EXIT
SEQUENCE
SEQ NO. :1
TITLE :SEQ 1
START
<SEQUENCE SET>
DELETE
BACK EXIT
SEQUENCE
NO. PESET INTERVAL
>> 01 002 03
02 001 03
03 - - - - -
04 - - - - -
05 - - - - -
06 - - - - -
EDIT 01 003 03 INS
BACK EXIT
AUTO CRUISE(SEQUENCE)
40
Page 42
IR Speed Dome Operating Manual
The dome supports 4 pattern tours and each pattern
cover at most 10 Minutes of 500 commands. Please check
the following steps to set up a pattern.
1)
PATTERN NO.:
Move the cursor here and press IRIS OPEN to
enter the setup of Pattern Number. Move the joystick to select a
pattern number (14) and press IRIS OPEN to confirm.
2) TITLE: Move the cursor here and press IRIS OPEN ro
enter the setup of Pattern Title .Check the detailed
above in DOME TITLE settings.
3)
<SET>: Move the cursor here and press IRIS OPEN to
enter.Move the dome up/down/left/right,make the zoom
in/out and press IRIS OPEN to save the pattern tour.
4) START: Move the cursor here and press IRIS OPEN to start the
current pattern tour.
5) DELETE: Move the cursor here and press IRIS OPEN to delete
the current pattern tour.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
MOTION
<PRESET> <SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING>
BACK EXIT
PATTERN
PATTERN NO. :1 TITLE :PATTERN 1 START <SET> DELETE
BACK EXIT
PATTERN TOUR
41
Page 43
IR Speed Dome Operating Manual
The use can set up zone title when the camera moves to a
defined location, which will make it much easier for the user to
identify the location. The dome supports 8 zone titles. Please
check the following steps to set up a zone
1)
ZONE NO.:
Move the cursor here and press IRIS OPEN to enter the
setup of Zone Number. Move the joystick to select a zone number
(1-8) and press IRIS OPEN to confirm.
2)
TITLE:
Move the cursor here and press IRIS OPEN to enter the
setup of Zone Title. Check the detailed above in DOME TITLE
settings.
3) <LEFT LIMIT>: Move the cursor here and press IRIS OPEN to
enter. Move the dome to a defined position as left limit and press
IRIS OPEN to save this left boundary.
4) <RIGHT LIMIT>: Move the cursor here and press IRIS OPEN to
enter. Move the dome to a defined position as right limit and press
IRIS OPEN to save this right boundary.
5) DELETE: Move the cursor here and press IRIS OPEN to delete the
current zone.
MOTION
<PRESET>
<SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING>
BACK EXIT
ZONES
--ZONE IS NOT SET-­ZONE NO. :1 TITLE :ZONE 1 <LEFT LIMIT> <RIGHT LIMIT> DELETE
BACK EXIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS HELP EXIT
ZONES
42
Page 44
IR Speed Dome Operating Manual
TIMING ACTION allows the user to set up the actions of the
dome in 7 days (each day with 8 timing segments). When
fishing the setup, the dome will do the actions according to
the setup motion during the defined time segment.
NO.:
Here shows the day within a week. Move the cursor here and press
IRIS OPEN to enter. Move joystick up or down to select the Serial No. (1-8)
for the timing action. Press IRIS OPEN to confirm.
START:
To set up the start time for the defined motion within this time
segment. Press IRIS OPEN to confirm.
STOP:
To set up the stop time for the defined motion within this time
segment. Press IRIS OPEN to confirm.
MOTION:
To setup the motion that will be operated in this time
segment. The motion includes: NONE. PRESET 1-8, SCAN 1-4, SEQUENCE
1-4 and PATTERN 1-4.
ON/OFF: Move the cursor here and press IRIS OPEN to enter to enable
or disable this function. Press IRIS OPEN to confirm.
COPY: The user could set up each 8 segment of 7 days separately or can
copy the finished setting for one day to the current day. Move the cursor
there and press IRIS OPEN to copy the settings.
BACK: Press IRIS OPEN to save and be back to last menu.
NOTE: It is not allowed to set up the same time segment during one day.
And the time segment can not exceed 00:00. During the timing action
segment, the defined action will be stopped if the user moves the dome.
If there is operation during the defined time segment, the action will
re-activated as long as it is in the defined timing action segment.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
MOTION
<PRESER> <SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING>
BACK EXIT
TIMING ACTION
NO. START STOP MITION
1 00:00 00:00 NONE 2 00:00 00:00 NONE 3 00:00 00:00 NONE 4 00:00 00:00 NONE 5 00:00 00:00 NONE 6 00:00 00:00 NONE 7 00:00 00:00 NONE 8 00:00 00:00 NONE
OFF MON COPY BACK
TIMING ACTION
43
Page 45
IR Speed Dome Operating Manual
The user can set up 8 motion detection scenes (each scene
with 4 detecting areas) under this menu. The alarm output will
be triggered when moving objects enter these detecting areas
SCENE NO.:
Move the cursor here and press IRIS OPEN to enter the
setup of Scene Number. Move the joystick to select a preset number (1-8)
and press IRIS OPEN to confirm.
<EDIT SCENE>:
Move the cursor here and press IRIS OPEN to enter.
Move the dome to a user-defined detecting scene. Press IRIS OPEN to
confirm.
<EDIT AREA>:
Move the cursor here and press IRIS OPEN to enter the
menu of AREA EDIT.
a)
AREA NO.:
Move the cursor here and press IRIS OPEN to enter
the setup of AREA Number. Move the joystick to select a preset
number (1-4) and press IRIS OPEN to confirm.
b) <AREA EDIT>: Move the cursor here and press IRIS OPEN to
enter the setup of AREA EDIT. The screen will display frame with
Serial No. The user can move the frame to the top left conner of
the wanted detecting area and press IRIS OPEN to confirm. Then
move the joystick to adjust the size of the detecting area and
press IRIS OPEN to confirm
c) DELETE: Move the cursor here and press IRIS OPEN to delete the
current detecting area.
d)
SENSITIVITY:
Move the cursor here and press IRIS OPEN to
enter. Select among LOW. MID and HIGH and press IRIS OPEN to
confirm the sensitivity.
e)
DELETE SCENE:
Move the cursor here and press IRIS OPEN to
delete the current scene.
f) AUX ACTIVATE: The dome can activate the alarm aux output
when detecting the moving object. Press IRIS OPEN to enter and
select between “ON” and “OFF” to activate or deactivate this
function.
g) CANCEL (SEC): Here means when the alarm aux output is
activated by the detecting function, for how long it will last before
the aux output will be closed. The time ranging 1-60 Sec.
h) START: Move the cursor here and press IRIS OPEN to start the
function of motion detection.
AREA EDIT
AREA NO. :1 <AREA EDIT> DELETE SEN SITIVITY :MID AREA DISPLAY :OFF
BACK EDIT
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS HELP EXIT
MOTION
<PRESTE> <SCAN> <SEQUENCE> <PATTERN> <ZONES> <TIMING ACTION> <MOTION DETECT> <AUTO TRACKING> BACK EXIT
MOTION DETECT
SCENE NO. : 1 <EDIT SCENE> <EDIT AREA> <DELETE SCENE> AUX ACTIVATE :OFF CANCEL(SEC) :5 <START>
BACK EXIT
MOTION DETECT
44
Page 46
IR Speed Dome Operating Manual
Under the auto tracking mode, the dome will auto track
the moving objects entering the scene. When the object is
moving out of the scene, the dome will return to a preset
position as defined after the defined time.
SENSITIVITY:
The user can set up the auto tracking sensitivity under
this menu. When set as LOW, the dome will do auto tracking when obvious
object entering the screen. When set as HIGH, the dome will do auto
tracking when small object moving into the screen. Move the cursor there
and press the IRIS OPEN to enter. The options include: LOW, MID and HIGH.
TARGET: To set up the size of the tracking object. The options include
Large. MID and SMALL.
AUX: If set “ON” here, the object auto tracking will activate alarm aux
output at the same time. Press IRIS OPEN to enter to select “ON” or “OFF”
ZOOM MATCH: Under the auto tracking model, if turn on the function of
ZOOM MATCH, the dome will do zooming in and out during auto tracking
to keep the right proportion between the object and background. Move
the cursor there and press the IRIS OPEN to enter. And move the joystick to
select the optical zoom.
ENABLE: Move the cursor here and press IRIS OPEN to enter to select
ONor OFFto enable or disable this function.
MOTION
<PRESET>
<SCAN>
<SEQUENCE>
<PATTERN>
<ZONES>
<TIMING ACTION>
<MOTION DETECT>
<AUTO TRACKING>
BACK EXIT
AUTO TRACKING
SENSITIVITY :MID
TARGET :MID
ZOOM MATCH :OFF
AUX :OFF
ENABLE :OFF
<TRACKING SCENE SET>
BACK EXIT
TRACKING SCENE SET
<TRACKING SCENE SET>
DELETE
RETURN DELAY :10SEC
BACK EXIT
MAIN MENU
LANGUAGE:ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT
AUTO TRACKING
45
Page 47
IR Speed Dome Operating Manual
TRACKING SCENE SET: Here the user can set up the scene
that the dome will get back to when finishing the action of
auto tracking. Move the cursor here and press IRIS OPEN to
enter. Move the dome to the wanted scene and press IRIS
OPEN to confirm.
DELETE: Move the cursor here and press IRIS OPEN to delete the return
scene.
RETURN DELAY: To set up the time that dome will waiting to return to
this scene.
RESTART:The dome allows the user to reset its settings remotely under
this menu.
Move the cursor here and press IRIS OPEN to enter.
Select “OK” or “CANCEL” to continue the reset or cancel the reset.
MAIN MENU
LANGUAGE :ENGLISH
<SYSTEM
INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT
WARNING
ARE YOU SURE……
OK CANCEL
RESTART
46
Page 48
IR Speed Dome Operating Manual
FACTORY DEFAULTS will allow the user to recover all
the setting to factory default setting.
Move the cursor here and press IRIS OPEN to enter. Select
“OK” or “CANCEL” to continue the reset or cancel the reset.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS
HELP EXIT
WARNING
ARE YOU SURE…..
OK CANCEL
FACTORY DEFAULTS
47
Page 49
IR Speed Dome Operating Manual
The user can get help information by “HELP” menu.
Open “MAIN MENU”
1) Move the cursor to “HELP” and enter IRIS open to
confirm.
2) Move the cursor to “BACK” and enter IRIS open to
get back to the main menu.
3) Move the cursor to “EXIT” and enter IRIS open to exit
the dome menu.
MAIN MENU
LANGUAGE :ENGLISH <SYSTEM INFORMATION> <DISPLAY SETUP> <DOME SETTINGS> <CAMERA> <MOTION> RESTART FACTORY DEFAULTS HELP EXIT
MENU OPERATION HELP
1. Call preset 95 to open menu
2. Move joystick to select menu item
3. IRIS open to enter edit mode
4. Move joystick to edit parameter
BACK EXIT
HELP INFORMATION
48
Page 50
IR Speed Dome Operating Manual
After- sales service
For speed dome production in our company, our company promises one year
warranty. Under warranty, maintenance service is provided for free. But for the
following situations, material and manual cost need to be paid.
Don’t operate in accordance with User’s Manualto cause damage.
The damage caused by force majeure factors such as lighting and fire, etc
The damage caused by other manufacturer’poor design and matching problem
*The Company Statement
Because our company continuously adopt new technologies, product parameters change without prior notice. The final interpretation of operation instructions belong to our company.
49
Page 51
IR Speed Dome Operating Manual
APPENDIX: Lighting and surge protection
45°
Grounding Conductor Resistance
Is Not Greater Than 4Ω
Steel Tube Protector
Vedio Arrester
Communication Arrester
Power Source Arrester
Lightning Rod
The Speed Dome Must Be Intalledin The Range Of Lightning Rod Under 45 Degrees
This product USES the gas discharge tube of TVS diode and protection circuit, can effectively prevent the 3.0 kV following transient lightning and surge lamp all types of pulse signal to the damage of equipment. But, for outdoor installation according to the actual situation on the premise of guarantee the electrical safety to do the necessary protective measures:
Signal transmission line must be with the high voltage equipment goods between high
voltage cable to keep a distance of at least 50 meters
Choose as far as possible outside wiring along the roof line
For open field must adopt sealing pipe buried wiring way, and the steel pipe by
one-point earthing, absolutely forbidden by wiring overhead way
In strong thunderstorms or high induction voltage region (e.g., high voltage transformer substation), must be taken to add extra high power lightning protection equipment and installation of lightning rod and other measures
Lightning protection and grounding design of outdoor installation and wiring must be combined with the construction of lightning protection requirements into consideration, and conform to the requirements of relevant national standards and industry standards.
The system must be equipotential grounding. Grounding device must meet the system anti-interference and electrical safety requirements, and shall not be short term or mixed with strong power grid zero line. System separate grounding, grounding resistance is not greater than 4Ω.
50
Loading...