*Please read this manual carefully before the installations and operations.
Transportation Security
No heavy stress, violent vibration or water splash are allowed during transportation, storage. The
unit should be transported in separated packing. In shipments of distributor and delivery of
maintenance, any damages caused by integral packing are not covered by warranty.
Installation
Avoid heavy stress and violent vibration during installation. Don’t touch the dome cover directly
by hand. When connecting the power source, please follow all electric safety standards and only use
the power supply designated for this device. Keep the video and control signal in a decent distance
from high voltage devices and cable. Don’t apply power to dome before finishing the installation.
Internal Environment
Keep metal and inflammable material away from dome body to avoid fire short circuit and
damage. Please prevent all liquids material from entering the dome. If this occurs, please shut down
the power and pull out the plug-in. Then please inform the technical personnel immediately.
Electrical Safety
The video image would be interfered when the dome is installed near Television, radio transmitter,
voltage changer and audio amplifier.
Camera Protection
Avoid shooting very bright objects directly into the camera’s CCD (such as the sun or light fittings)
and avoid fixating the camera lens on bright static object for long time, as it will cause Irreparable
damage to the camera’s CCD.
Cleaning Method
Please don’t use abrasive and violent detergent to clean the dome. Please choose dry fabric and
neutral detergent. And please use lens paper to clean the lens.
*Internal removing, assembly, repair and operations should be only
performed by qualified service personnel.
Please use our production under the following environmental standards:
Environmental Temperature:
Environmental Humidity:
-35 ~60 ℃
<95%
Barometric Pressure:
Power Supply:DC12V/4A
86~106KPa
1
Page 3
IR Speed Dome Operating Manual
Features
Main Features
• Stepless speed changes, auto zoom/speed matching
• Pan 0.01~360o/S, Tilt 0.01o~120o/S, Preset: 360o/S (high speed IR speed dome)
• Pan 0.5o~35o, Tilt 0.5o~35o, Preset:35o/s (for Vari-speed IR dome)
• Auto object track with zoom in/out and motion detection (Auto Track Model)
• Timing actions for 7 days of programmable schedule
• Built-in Semi-conductor heater & digital temperature sensor
• PWM cooling fan vari-speed temperature control
• Reserved network interface and space for network module
• Pan Tilt accuracy +/- 0.1o, 256preset positions
• 8 cruising tracks, each cruising track has 32 presets
• 4 pattern tours,10 Mins memory, 500 programmable instructions
• Multi-Protocol through RS485 or coaxial cable.
• 8 auto scan with use-defined left and right boundaries and settable scan speed
• 8 Privacy Zones with defined English camera title
• Auto Compatible PELCO_P, PELCO_D compatible
• Guard Location: the dome will rotate back to preset position after a period of vacant time
• Alarm triggering: the alarm can trigger preset, auto scan, cruising and pattern tours functions
• Soft Address Function: the use can set up the dome address without uninstall the dome
Integrated Super Speed PTZ Rotator
• Delicate stepping motor, stable, sensitive and accurate
• 360° Pan and 90° Tilt range (auto-flip) without blind area
• Stepless speed change, auto zoom/speed matching
• Near / far IR Light auto matches camera zoom in/out
Built-in High Definition Day/Night Camera
• Auto iris, auto back light compensation
• Auto/manual white balance
• Auto/manual brightness control
• Auto/manual focus
• Multiple compatible camera brands including Sony, Samsung, LG, CNB, Sanyo etc.
All-weather Outdoor Design
•
6 Inch High die-cast alloy aluminum construction
• High Precision Mould with high heat conductivity
• Fully enclosed isolation design for heat sink
• Nanometer Dustproof, waterproof and fog-proof lens
2
Page 4
IR Speed Dome Operating Manual
• IP66 Waterproof
• 3000V lightning and surge current protection
Function Instructions
• Focus / PTZ Speed Auto Match
The pan/tilt rotation speed could be automatically adjusted according to the focus in/out, which
makes it much more practical for manual target tracking. (Only for the auto tracking IR speed dome)
• Auto Flip
When the camera tilts downward and goes just beyond the vertical position, the camera will
rotate 180 degrees.
• Preset Position Set up and Call Up
In the Preset function the dome stores the current pan/tilt angle, zoom and other position
parameters in its memory. When necessary the dome recalls these parameters and adjusts the camera
to a particular position. The user can store, recall and clear the presets easily and promptly by using
the keyboard controller. The dome can store up to 220 presets.
• Auto Scan
Users can set up the left and right boundaries by control keyboard. Then speed dome can scan
between this boundary. It supports up to 8 groups of scanning paths.
• Cruising Track
The preset position can be programmed to be recalled in a set of sequences. This sequence can be
set to let the camera scan from one position to the next in a cycle at a set speed. This feature is called
the “auto cruise”. The cruise sequence and dwell time of each preset can be set. It supports up to
8cruising tracks, each cruising track with 32 presets.
• Pattern Tour
Dome can memorize 600S running path or 500 programmable instructions. When start pattern
tour, speed dome will move automatically according recorded action path. It supports 4 groups of
pattern tours.
• Guard Location
The dome automatically return to preset position if there is no operation in period of vacant time.
• Default Action
When you start up the dome camera or do not send commands over a long time, the dome
camera will return to its default functions which include the home place, auto pan, auto cruise and
pattern.
3
Page 5
IR Speed Dome Operating Manual
1)Zoom Control
2)Focus Control
3)Auto Iris Control
4)Auto Back Light Compensation
• Dome Address Setup
The dome supports up to 256 addresses and the dome will only response to the instructions given
to its own address. Please check the dip switch on the bottom of the dome for address setup.
• Manual Object Tracking
The use can move the joystick up, down, left or right to track the appearing object in the screen
and use the joystick to zoom in and out with auto focus.
• Privacy Mask Protection
Set black mask areas to protect the privacy zones. The black privacy locations can be set, and
support up to 8 mask zones.
• Timing Running Function
Users can set speed dome operation task at total 8 timing areas during 7 days.
Coordinates and Directions Display
•
User can define the dome’s direction of due north, which will help to show up the exact moving
directions on screen. And zone title is supported to display when the dome moves to the specified
zone.
• Auto Tracking
The dome will automatically fix and track the moving object according to the user’s setup via OSD.
• Motion Detection
The dome will detect the changes in the defined video zone and trigger alarm.
It supports to 8 video Locations, each with 4 detection zones.
• PTZ and Lens Control
Users can control zoom by keyboard to get near or far images.
The default setting is auto focus. The camera will auto focus based on the center of the video
display to get the clear image. In some special occasions, the user could do the manual focus to get the
desired image effect.
Auto Iris is aiming to detect the environmental lights condition and adjust the iris to get the
stabilized brightness of the image.
In the highly bright background, auto back light compensation is aiming to compensate the
brightness of the dark object and adjust the background brightness to get a clear image.
4
Page 6
IR Speed Dome Operating Manual
5)Auto/Manual White Balance
6)Day and Night Switch (Only for Day/Nigh Camera)
7)OSD Setup (Only for camera with menu)
Auto/Manual WB adjust depending on the environment light changes.
Speed dome camera can auto switch according to the environmental illumination changes.
Call upon preset No.95 to enter into OSD menu setup interface. Press “Focus” to choose menu
8 auto scan tracks, user-defined left and right boundaries and scan
speed
Auto Cruising:
8 cruising tracks, each cruising tracks has 32 preset positions,
user-defined dwell time
Pattern Tour:
4 patterns, up to 500 instructions per pattern
Guard Location:
The dome will rotate back to preset position after a period of vacant
time.
IR LED On Mode:
Manual/Auto/Timing
Data Communication:
RS-485
Protocols:
Auto Compatible PELCO_P, PELCO_D
Camera Module:
Auto Compatible SONY, LG, Samsung, CNB, HITACH, etc.
Baud Rate:
2400/4800/9600bps
Operating Humidity:
0~90%
Operating Temp:
-35oC +55oC
6
Page 8
IR Speed Dome Operating Manual
Installation Guide
ModelsMax Distance(Feet\Meter)
RG59/U750ft(229m)
RG6/U1,000ft(305m)
RG11/U1,500ft(457m)
Preparations
• Basic Requirements
All the electric work must be finished under the latest electric & fire prevention law and rules (and
any related law and rules). Please check according to the packing list if every accessory is included. And
also make sure the installation is operated as required. Please contact us for any help during the
installation.
• Installation Space and Density Checkup
Please make sure the space is big enough to install our dome. And also ensure the density of the
ceilings or walls to hold total weight of the dome and its accessories.
• Cables Preparation
Please choose the proper cable according to the transmission distance. The min requirement of
coaxial BNC cable is listed as follows for reference:
Installation Method
The IR speed dome could be installed in wall-mount and pedant-mount
Installation Dimensions
7
Page 9
IR Speed Dome Operating Manual
304
297
Ø210
Dome body rack
Wiper
Dome Housing
Power adapter bracket
Protective sling
Pendant-mout
bracket
Ø210
485
220
78
100
100
125
Wall-mount
4-Ø8
Ø105
Ø105
Pendant-mout
•Wall Mount
Picture01picture02
•Pendant Mount
Picture03picture04
Installation Procedures
Notice: The wall and ceiling must be thick enough to install the expansion
bolts and can bear 4 times the weight of the dome camera itself.
8
Page 10
IR Speed Dome Operating Manual
Wall-mount Installation Procedures
1) Take out the wall-mount bracket from the package , mark the installation hole
positions on the wall referencing to the dimension as picture 02.
2) Drill the hole and install 4 pieces of M8 expansion bolt into the hole.
:
(
Picture 05
3) Take out the IR speed dome and put the cables through the bracket.
Use M5 screws to fix the bracket and dome body, as picture 01
4) Use 4 pieces of M8 screw nuts with washer to fix the bracket on the wall.
Pendant-mount Installation Procedures
)
:
1) Take out the pendant-mount bracket from the package , mark the installation
hole positions on the ceiling referencing to the dimension in picture 04.
2) Drill the hole and install 4 pieces of M8 expansion bolt into the hole, as
picture05
3) Take out the IR speed dome and put the cables through the sockets on the
bottom of the pendant bracket. Use M5 screws to fix the bracket and dome body,
as picture 03
9
Page 11
IR Speed Dome Operating Manual
Dome Setting
Before the dome is installed, please finish the setup of the communication
SW1— Dip switch for
the dome address
SW2
—
Dip switch for
the dome protocol
4) Use screw nuts with washer to fix the bracket on the wall.
Notice: Pendant-bracket is not designed for outdoor installation. If specially
required, please do make sure the waterproof installation of the dome.
protocol, baud rate and dome address. Set the DIP switch inside the dome body.
The relative DIP switch site and connecting wires are diagrammed below for
reference.
10
Page 12
IR Speed Dome Operating Manual
Baud RateSW2-5SW2-6
9600OFFOFF
4800ONOFF
2400OFFON
Reserved……
Protocol Setup
Our IR speed dome supports three protocols including Pelco P, Pelco D and HS.
All of them supports baud rate of 9600bps、4800bps、2400bps.
Set the No.1~4 dip switch for the protocol configuration.
Our IR Speed dome supports 220 preset positions. You can activate some special functions by
calling upon code number 65-99.
Serial
No.
1Start Auto ScanCall 99
2Start Auto CruiseCall 98
3Start Pattern TourCall 97
4
5
6
7
8Open OSD Menu
9Remote ResetCall 94
Stop Auto Mode/End up
CommandFast Call UpNote
Start Auto Scan of
Group No.
Start Auto Cruise of
Group No.
Start Pattern Tour of
Group No.
Setting
Call 80+ Call pp+ Call 99
Call 80+ Call pp+ Call 98
Call 80+ Call pp+ Call 97
Call 96
Set 95(or Call 95)
Default to startauto scan of
group No.1
Default to startauto cruise of
group No.1
Default to startpattern tour of
group No.1
pp means:Group No.1-8
pp means:Group No.1-4
10Recover Factory DefaultCall 82
•System Self-Testing
The dome will do self-testing after power up, and system status will show “Normal” if system Is
running normally.If error happens, testing result will be shown in “○” or “X”. “○” means normal and
“X” means error. Please check the according meaning as follows:
13
Page 15
IR Speed Dome Operating Manual
IRIS
OPEN
IRIS
OPEN
IRIS
OPEN
•OSD Menu Operations
Call Preset 95 to enter the main OSD menu (or call preset No.1 two times
continuously within two seconds)
Control the joystick to move the cursor around the menu
Press “Iris Open” to enter the menu for selections
Move the joystick up and down to select the item
Press “Iris Open” to confirm the selection
Press “Iris Close” to cancel the selection
*Note: If your controller does not have a joystick, use the up or down key.
information, dome title, version, date, time, and temperature
scale.
Use the following steps to display the System
Information screens:
1) Use the joystick to position the cursor along the SYSTEM
INFORMATION.
2) Press Iris Open. The SYSTEM INFORMATION screen opens.
3) Mover the joystick up and town to select the item.
4) Press Iris Open to enter the setup of each item.
OTHERS
TITLE :DOME TITLE
VERSION:V220ST
DATE:2009-01-01
TIME:10:20:00
TEMP SCALE:CELSIUS
BACKEXIT
MAIN MENU
LANGUAGE :ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT
SYETEMINFORMATION
DOME ID :1234567890
ADDRESS:001
BAUDRATE:2400
PROTOCOL:PELCO-D
TEMPERATURE:31℃
VOLTAGE:12.0V
ALARM :000000 00
<OTHERS>
BACKEXIT
•SYSTEM INFORMATION
17
Page 19
IR Speed Dome Operating Manual
Display setup allows the user to define the way to display
the dome titles on the monitor.
The displayed titles are listed as follows:
Two options for the Dome Title and Date/Time: OFF and ON
Other setup selections include:
Move the cursor by joystick to the one you need to set, and press Iris
Open to enter the item. Move the joystick select the status and press Iris
Open to confirm.
Titles can be placed anywhere on the monitor. This
feature allows you to customize the window of your monitor
screen. To set a title position:
1)Use the joystick to position the cursor in the DISPLAY POSITION
2)Press Iris Open.
3)Use the joystick to move the title up, down, left, or right.
4)Press Iris Open.
5)Repeat steps 1 through 4 to position other titles
6)Position the cursor at BACK or EXIT. Press Iris Open to save settings
and exit menu.
•IR LED
The user can open and close the IR LED manually and set
up the IR LED work mode under this OSD mean. (Under normal
operation mode, the user can press IRIS OPEN and IRIS CLOSE
to adjust the IR LED power):
1) CONTROL MODE:
DOME TITLEIndicate dome
PRESETIndicate the dwell time for preset title
AUTO FUCTIONIndicate the dwell time for auto function titles
ZONESIndicate the dwell time for zone titles
DATE/TIMEDisplay the current date and time
OFFTitle will not be displayed when activated
ONTitle will be continuously displayed when activated
2 SECTitle will be displayed for 2seconds after activation
5 SECTitle will be displayed for 5seconds after activation
10 SECTitle will be displayed for 5seconds after activation
3) IR LED POWER: Here the use can choose the power mode covering: NORMAL, MATCH and USER.
4) AUTO CONTROL:When it is on, the IR LED will turn its power consumption to the standby status
5) STANDBY POWER: When the AUTO CONTROL is on, the user can set up the standby power here.
6) STANDBY DELAY: Set up how long if there is not moving object, the IR LED will turn into standby
7) SENSITIVITY: When the AUTO CONTROL is on, the user can set up the sensitivity to detect the
8) ENHANCED MODE: Under normal status, press IRIS OPEN to enhance the IR LED power, when it is
9)START/STOP TIME: Set up time for IR LED to open and close under “TIMING” of control mode.
1) Numbers : Move the cursor to “NUMBER” and press IRIS OPEN
2) Speed: Move the cursor to “SPEED” and IRIS OPEN to enter the
3) Start : Move the cursor and press IRIS OPEN to start wiper.
AUTOIR LED will be opened or closed automatically according to the
light conditions.
TIMINGLED will be adjusted according to Open and Close Time.
OPENIR LED forcedly open
CLOSEIR LED forcedly close
CAMERAIR LED status (Open/Close) will be synchronized with Camera
NORMAL: Near IR LED will be turned on when wide angle. and Far IR LEDwill be turned on when
small angle.
MATCH: The Near and Far IR LED will be turned on and off automatically to match the zoom in and
out.
USER: The user can manually adjust the Near and Far IR LED.
which will effectively extend the service life of IR LEDs. And under this mode, when objects appear
in the screen, the IR LED will turn its power consumption back to the normal status.
status.
moving objects.
turned to maximum, press IRIS OPEN continuously for 2 seconds to enter the enhanced mode. And
the whole brightness of the image will be improved. Move the cursor to EHNANCED MODE and
press IRIS to enter and select between” STATIC” and “DYNAMIC”
•WIPER
The user can make adjustment for the wiper under
this menu (suitable for wiper-equipped dome)
to enter the setup of Wiper Number. Move the joystick up and
down to select number (1-10),then press IRIS OPEN to confirm.
setup of Wiper speed. Move the joystick up and down to select
“HIGH” ,“MID ”OR “ LOW”, the press IRIS OPEN to confirm.
19
Page 21
IR Speed Dome Operating Manual
•IDLE
IDLE setting means if there is no command for the
dome for a period of time, the dome will run the actions
as defined.
1) TIME: Move the cursor to “TIME” and press IRIS OPEN to enter,
and move the joystick up and dome to select among 30 sec, 1 min,
5 min, 10 min and 30 min. And press IRIS OPEN to confirm.
2) ACTION: Move the cursor to “ACTION” and press IRIS OPEN to
enter. Move the joystick to select the actions including” NONE,
PRESET, SCAN, SEQUENCE, PATTERN. Press IRIS OPEN to confirm.
output. (optional function). When an alarm is received, an
input signal to the dome triggers the user defined action
(such as presets, patterns, etc.), and at meantime the
alarm output signals is activated.
ALARM NO.: Move the cursor to the ALARM NO. Press IRIS OPEN to
enter and move the joystick up and down to select the alarm input
no. (Channel 1 and Channel 2)
INPUT STATE: Set the alarm contact status. There are two input
states, OPEN and CLOSE.
ALARM MODE:
ACTION: Set the alarm action:
ALARM OUT: Set the auxiliary to activate:
RESET TIME: Set up time for the alarm output (such as an alarm
buzzed) when is triggered by the detector.
START /STOP TIME: Set up the time to start alarm and stop alarm
ONLY under the AUTO mode under ALARM MODE.
OFFAlarm function is deactivated.
ONAlarm function is activated.
AUTOAUTO Alarm function will be activated and deactivated
between START TIME and STOP TIME.
NONE(default) No action
PRESETDome goes to preset. (Default as Preset 1)
SCANDome starts auto scan (Default as Auto Scan 1)
SEQDome runs auto cruise (Default as Auto Cruise 1)
PATTERNDome runs pattern (Default as Pattern 1)
OFFNot alarm output will be activated.
OUT1An alarm action will close AUX 1 output..
OUT2An alarm action will activate AUX2 output.
The user can set up the dome title to define each camera.
Dome title support up to 12 characters.
Move the cursor according the left steps and select INPUT.
Press IRIS OPEN to enter.
1)Move the joystick left and right to position “←”, and press IRIS OPEN
to delete the character at“←”.
2)Press IRIS CLOSE to exit the edit mode.
3)Move the cursor to “<CAP>” and press IRIS OPEN to enter. Move the
joystick up and down to select the input method (such as English Cap,
English, Chinese, Figures, and Symbols)
4)Mover the cursor to next line of <CAP> and press IRIS OPEN to enter
the mode of character input. The selected character will be shown in
high brightness. Move the joystick up/down/left/right to choose the
needed characters. Press IRIS OPEN to move the selected character
to the INPUT position at“←”.
5)After finishing the character inputs, move the cursor to “OK” and
press IRIS OPEN to confirm.
6)Also user can move the cursor to “CANCEL” to cancel the character
input settings.
OTHERS
TEMP MODE :AUTO
PRESET FREEZE :OFF
AUTO FLIP :ON
BROADCAST :ON
MENU STYLE :IMAGE
STOP TIME :30 SEC
MENU OFF TIME :5 MIN
<DOME TITLE>
<AZIMUTH ZERO>
BACKEXIT
can enter this menu to set up.
Move the cursor to DOME SPEED and press IRIS OPEN to
enter. Move the joystick to select the dome speed when
doing the pan movement.
Move the cursor to BACK/EXIT and press IRIS OPEN to
run the command of BACK or EXIT.
To make a selection of the dome speed, the user
29
Page 31
IR Speed Dome Operating Manual
NONE(default) No action
PRESETDome goes to preset. (Default as Preset 1)
SCANDome starts auto scan (Default as Auto Scan 1)
SEQDome runs auto cruise (Default as Auto Cruise 1)
PATTERNDome runs pattern (Default as Pattern 1)
in module. The user set as follows:
Move the cursor to “DOME VIDEO”, press IRIS OPEN to the
setting mode. Move the joystick up and down to select
“PAL” or “NTSC”, press the IRIS OPEN to confirm.
The dome can also output video signal without build-
34
Page 36
IR Speed Dome Operating Manual
The user can set up TEMP MODE, INTERNAL FAN, PRESET FREEZE,
STOP TIME. MENU OFF TIME and NORTH ZERO here under the menu of
“OTHERS”
TEMP MODE: To set up the control mode of dome fans and heaters. It
includes three modes of AUTO, FAN HIGH SPEED and FAN LOW SPEED.
PRESET FREEZE: This feature freezes the scene on the monitor when
going to a preset. This allows smooth switching from one preset scene
to another.
AUTO FLIP: When the camera tilts downward and goes just beyond
the vertical position, the camera will rotate 180 degrees. The user can
press IRIS OPEN to enter and choose to turn on/off this function.
STOP TIME: To set up the time that dome will stops after receiving
the last command. Options include 5/15/30/60 Sec.
MENU OFF TIME: To set up the time that OSD menu be off when no
operations. Options include 1/2/5/10 min.
NORTH ZERO: To set up the due north of the dome (pan 0º)
Move the cursor here and press IRIS OPEN to enter. Move the joystick
to control the dome to pan 0º and press IRIS OPEN to confirm.
1) Move the cursor to “HELP” and enter IRIS open to
confirm.
2) Move the cursor to “BACK” and enter IRIS open to
get back to the main menu.
3) Move the cursor to “EXIT” and enter IRIS open to exit
the dome menu.
MAIN MENU
LANGUAGE :ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT
MENU OPERATION HELP
1. Call preset 95 to open menu
2. Move joystick to select menu item
3. IRIS open to enter edit mode
4. Move joystick to edit parameter
BACKEXIT
•HELP INFORMATION
48
Page 50
IR Speed Dome Operating Manual
After- sales service
For speed dome production in our company, our company promises one year
warranty. Under warranty, maintenance service is provided for free. But for the
following situations, material and manual cost need to be paid.
Don’t operate in accordance with 《User’s Manual》 to cause damage.
The damage caused by force majeure factors such as lighting and fire, etc
The damage caused by other manufacturer’poor design and matching problem
*The Company Statement
Because our company continuously adopt new technologies, product parameters
change without prior notice.
The final interpretation of operation instructions belong to our company.
49
Page 51
IR Speed Dome Operating Manual
APPENDIX: Lighting and surge protection
45°
Grounding Conductor Resistance
Is Not Greater Than 4Ω
Steel Tube Protector
Vedio Arrester
Communication Arrester
Power Source Arrester
Lightning Rod
The Speed Dome Must Be
Intalledin The Range Of
Lightning Rod Under 45 Degrees
This product USES the gas discharge tube of TVS diode and protection circuit, can
effectively prevent the 3.0 kV following transient lightning and surge lamp all types of
pulse signal to the damage of equipment. But, for outdoor installation according to the
actual situation on the premise of guarantee the electrical safety to do the necessary
protective measures:
Signal transmission line must be with the high voltage equipment goods between high
voltage cable to keep a distance of at least 50 meters
Choose as far as possible outside wiring along the roof line
For open field must adopt sealing pipe buried wiring way, and the steel pipe by
one-point earthing, absolutely forbidden by wiring overhead way
In strong thunderstorms orhigh induction voltage region (e.g., highvoltage
transformer substation), must be taken to add extra high power lightning protection
equipment and installation of lightning rod and other measures
Lightning protection and grounding design of outdoor installation and wiring must be
combined with the construction of lightning protection requirements into consideration,
and conform to the requirements of relevant national standards and industry standards.
The system must be equipotential grounding. Grounding device must meet the system
anti-interference and electrical safety requirements, and shall not be short term or
mixed with strong power grid zero line. System separate grounding, grounding resistance
is not greater than 4Ω.
50