Operation Manual for Intelligent Speed Dome Camera
I. Points for Attention
1. Please read the operation manual carefully before installing and operating the product.
2. The product takes power supply of AC24V. The rated input voltage of the camera is
marked on the base or other corresponding place.
3. During the course of transportation, storage and installation, the product should be avoided
from incorrect operations such as heavy pressing, strong vibration etc., which can cause
damage of product as there are sophisticated optical and electronic devices inside the
machine.
4. Do not attempt to disassemble the camera. In order to prevent electric shock, do not
remove screws or covers. There are no user-serviceable parts inside.
5. Always follow all electrical standards for safety when it is in operation. Adopt the
particular power supply which is provided with the unit. RS-485 and video signal should
keep enough distance with high voltage equipments and cables when they are in
transmission. Precautions for anti-lightning and anti-surging should be taken if necessary.
6. Do not operate it in case temperature, humidity and power supply are beyond the limited
stipulations.
7. Do not let the camera aim at the sun or the object with extreme light whatsoever it is
switched on or not. Do not let the camera aim at or monitor bright and standstill object for
a long time.
8. Do not use aggressive detergent to clean the main body of the camera. Wipe dirt with dry
cloth. If needed, mild detergent can be used suitably.
9. Operate the intelligent speed dome camera with great care to avoid shock or vibration. It
operate incorrectly, the Speed Dome could be damaged
10. Be careful to avoid to crash, Never mount the unit on a ceiling that cannot support its
weight.
11. If necessary, use a commercial lens cleaning paper to clear the lens windows. Gently wipe
the lens window until clean.
1
Page 3
Operation Manual for Intelligent Speed Dome Camera
II. Description of Functions
The intelligent dome camera is a hi-tech CCTV product which incorporates high-clarity
color camera, panoramic speed-variable PAN/TILT, multifunctional decoder, CPU processor,
memory chip into a whole. It can largely reduce connection and installation processes of
components in the system, rise up reliability of the system and facilitate installation and
maintenance. Therefore it has advantages of beautiful appearance, compact structure and easy
operation.
1. Integrated Multi-Protocol Decoder
a. With integrated decoder and multi-protocol, it can integrate 16 kinds of
communication protocols in maximum. As its baud rate of communication can be
adjusted, it is compatible with many normal systems by easy setup inside the dome
camera, so it has stronger versatility.
b. RS485 serial control: addresses of camera 1-1023.
2. Integrated speed-variable PAN/TILT
a. Turning 360°horizontally and continuously with unlimited positions and an adjustable
speed from
b. Running stably at low speed with super lower noise. Pictures have no shaking.
c. the location precision up to ±0.1°.
3. High Intelligent Degree
a. As much as 128 preset positions can be preset with powerless memory;
b. The camera can scan horizontally between two points and scan speed can be modified.
The positions of linear scan are optional and the dome camera can scan the range
larger or smaller than 180° between any two points with adjustable speed;
c. Six sets of programmable patrol with 16 position each set. the detention time are
adjustable respectively;
d. The self-learning function of the locus. 3 loci, the time length of each locus is more
than 120 seconds with powerless memory;
e. Character Overlapping. The humane structure of the menu makes all setups and
0 -- 300°/s; turning 0 - 90°vertically with a speed up to 120°/s.
programming of the dome camera more convenient and easy.
f. Angle display. The dome could display the panning angle, tilting angle and the view
angle of the camera.
g. Proportional pan function.The speed dome will depend on the amount of zoom. At
telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of
joystick deflection than at wide zoom settings. This keeps the image from moving too
fast on the monitor when there is a large amount of zoom. This slowing does not
happen when going to a preset, but does occur in turbo mode when high zoom is
selected. The minimum pan and tilt speeds are 0.1 degree per second at full zoom.
h. The Integrated Multi-Protocol. Multiple communication protocols are integrated
inside the dome camera with selectable baud rate from 2400 bps to 19200 bps.
i. Electrify Return. Electrify return to the situation before shut.
j. Menu Password Protection function. Input password to enter the menu, such function
ON/OFF for optional.
k. The dome title display. The dome title could be set to display in the dome menu.
l. Temperature display. The temperature could be set to display in the dome menu.
m. Alarm Function. Four-channel Alarm Input, One-channel Alarm Output.
n. Long-distance Address Modify Function. To modify the dome address by RS485.
2
Page 4
Operation Manual for Intelligent Speed Dome Camera
Principle: we call “hard ID (HID)” that setting by the Dip-switcher, and “Soft ID
(SID) that setting by the Long-distance address modify. The HID and the SID are
same in leaving factory. For example: Camera No.001, HID=SID=001, we change
the SID=002 by RS485, so we should select the No. 002 to control it, and the SID
address will be remember after shut. And if we change the HID=003 by Dip-switcher,
the HID and the SID will be both change to HID=SID=003
4. Functions of the Camera
a. Description of the Focus Control Mode: the user can adjust the focus of the camera
manually. When the camera is on near focus, the icon
appears on the screen;
when on the nearest state, the icon appears while on the far focus, the icon
appears.
b. Description of Backlight Compensation: when the object to be shot is dark and
looks dim, the user can open the backlight compensation according to actual need. and
the icon
appears on the screen.
c. Description of White Balance: when the image has color distort on the screen, the
user can set different modes by orders. There are 6modes for options: Indoor Mode ①
Outdoor Mode ② Touch Mode ③ Automatic T④race of White Balance
ATW Manual WB⑤-MAN Automatic Mode.⑥
d. Description of ZOOM Control: user can “pull near” or “push far” the lens according
to actual conditions, and the symbol appears on the screen in which
the front part means optical multiplication while the rear part means digital
multiplication.
e. Electron shutter: it is 1/50 sec after the camera electrified, and it will display 50 on the
monitor.
f. AE Mode: setup of Manual/Automatic.
g. Zero Illuminance: It is used only when the external brightness is extremely low.
Normally the camera works on the automatic state. In case the external brightness is
lower than 1Lux, the camera can be switch to the Zero Illuminance state automatically
and icon appears on the screen. You can also set the Zero Illuminance state
manually.
III. Setup of the Menu of the Dome Camera
1. Basic Operation of the Menu
1.1 Open the main menu of the setup by the keyboard or the matrix via the operation “Call
No. 64 preset position or No.95 preset position”. Besides that, continuously call No.1
preset position twice in 4 seconds, you can also open the menu; Through setting No.64
preset position in order to close the munu.
1.2 When the menu is displayed on the screen, operate “TILT UP”, “TILT DOWN” to move
the cursor to the option to be set, operate “PAN LEFT”, “PAN RIGHT” to modify the
content or the order to enter this option.
1.3 All setups on the menu couldn’t be lost even power failure happens.
2. Setup of the Menu
2.1 MAIN MENU
2.1.1 SYSTEM SETUP.
3
Page 5
Operation Manual for Intelligent Speed Dome Camera
2.1.2 DISPLAY SETUP: to enter the submenu of display of the screen by which ID display,
title display of preset point and display of camera screen can be set.
MAINMENU
2.1.3 CAMERA SETUP: to enter the submenu of setup of normal data of
camera.
2.1.4 MOTTON SETUP: to enter the setup of enhanced function of
1.<SYSTEM SETUP>
2.<DISPLAY SETUP>
3.<CAMERA SETUP>
4.<MOTION SETUP>
5.<PRIVACY MSK>
6.<ADVANCE SETUP>
7.SYSTEM RESET
8.EXIT
dome camera.
2.1.5 PRIVACY MASK: to enter the submenu of the camera privacy function setting.
2.1.6 ADVANCE SETUP.
2.1.7 SYSTEM RESET: to reset the system. The dome will make self-checking function
after it carries out reset function,the station for the dome's reset is :AUTO FLIP
-ON/PTZ SPD RATE-ON/ ID DISPLAY-ON/ANGLE DISPLAY-OFF/ DOME
120Ω term in a l re sisto r is
opened forR S485 bus
31
2
JP
120Ω t e rm inal resistor is
Bracket for fixed camera
connected on RS485 B us
Figure 2
2.Setup of Coding Switch of Dome Camera. As shown in Figure 2, SW1 is used to set
address of the dome camera from 1 – 1023. The ID-CODE from DIP-10 to DIP-1 are
equivalent to a 10-bit binary digit. DIP-10 is MSB while DIP-1 is LSB. The state “ON” of
each bit means 1 while “OFF” means 0. Following table shows states of coding switches
of some addresses.
ID-CODE Status Dome
Address
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 DIP-7 DIP-8 DIP-9 DIP-10
1 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF
2 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF
3 ON ON OFF OFF OFF OFF OFF OFF OFF OFF
4 OFF OFF ON OFF OFF OFF OFF OFF OFF OFF
5 ON OFF ON OFF OFF OFF OFF OFF OFF OFF
6 OFF ON ON OFF OFF OFF OFF OFF OFF OFF
7 ON ON ON OFF OFF OFF OFF OFF OFF OFF
8 OFF OFF OFF ON OFF OFF OFF OFF OFF OFF
9 ON OFF OFF ON OFF OFF OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF OFF OFF
11 ON ON OFF ON OFF OFF OFF OFF OFF OFF
12 OFF OFF ON ON OFF OFF OFF OFF OFF OFF
13 ON OFF ON ON OFF OFF OFF OFF OFF OFF
14 OFF ON ON ON OFF OFF OFF OFF OFF OFF
15 ON ON ON ON OFF OFF OFF OFF OFF OFF
16 OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
17 ON OFF OFF OFF ON OFF OFF OFF OFF OFF
18 OFF ON OFF OFF ON OFF OFF OFF OFF OFF
……………………………
1023 ON ON ON ON ON ON ON ON ON ON
Table 1
For Example:
ON
12345 6
78910
Speed Dome Address=1
ON
12345 6
78910
Speed Dome Address=4
ON
12345 6
78910
Speed Dome Address=2
ON
12345 6
78910
Speed Dome Address=18
ON
123456
78910
Speed Dome Address=3
ON
12345 6
78910
Speed Dome Address=1023
3.Setup of the Protocol and the Default Baud Rate. As shown in Figure 2, SW2 is used
to set the protocol of communication and the baud rate used by the dome camera. DIP-4
to DIP-1 of SW2 is used to select protocols and 16 different protocols can be selected in
12
Page 14
Operation Manual for Intelligent Speed Dome Camera
maximum. Following table shows states of coding switches of protocols selected by the
dome camera
Protocols
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6
B01 ON OFF OFF OFF OFF ON
Santachi OFF ON OFF OFF OFF ON
PELCO-P/D ON ON OFF OFF OFF OFF
PELCO-MK OFF OFF ON OFF OFF OFF
PANASONIC ON OFF ON OFF OFF ON
Longcomity OFF ON ON OFF OFF ON
HUNDA600 ON ON ON OFF OFF ON
LILIN OFF OFF OFF ON OFF ON
VICON ON OFF OFF ON ON OFF
MOLYNX OFF ON OFF ON OFF ON
KALATEL ON ON OFF ON ON OFF
VCL OFF OFF ON ON OFF ON
SAMSUNG ON OFF ON ON OFF ON
ALEC OFF ON ON ON OFF ON
Ultrak ON ON ON ON OFF ON
Protocol Settings Baud rate
Table 2
Some protocols and the states of the coding switches of normal baud rate of these
protocols are shown as follows:
4.Setup of the Baud Rate of Communication. As shown in Figure 2, SW2 is used to set
the protocol of communication and the baud rate used by the dome camera. DIP-6 and
DIP-5 of SW2 are used to select the baud rate of communication and 4 different baud
rates can be selected in maximum. If the controller adopts non-standard baud rate, you
can adjust it to be identical with that of the controller as per the following table.
Baud Rate of Communication DIP-1DIP-2 DIP-3 DIP-4
2400bps OFF OFF
4800bps ON OFF
Setup of Baud Rate
DIP-5 DIP-6
13
Page 15
Operation Manual for Intelligent Speed Dome Camera
9600bps OFF ON
19200bps ON ON
5.Selection of the Terminal Resistor of the Dome Camera. As shown in Figure 2, JP is
the select switch of the 120 Ω terminal resistor on the bus RS485, on which
only one terminal resistor of the dome camera at the farthest end can be connected, while
the terminal resistors of other devices should be opened.
6. Shortcut control function
Preset Set Preset Call Preset
1 Reserved Twice Call Preset Open the menu
64 Close the menu Open the menu
90 Reserved Reserved
91 1080i/59.94(Initial setting) Run patro
92 720p/59.94 Scan limit to left
93 NTSC(CROP) Scan limit to right
94 NTSC(SQ) Reserved
95 1080i/50 Open the menu
96 720p/50 Stop scan
97 PAL(CROP)
Auto scan
98 PAL(SQ) Reserved
99 Reserved Reserved
Ⅳ. The Installation of the System
1. The style of the Installation
1) Dimension of the Product
2) The Style of Installation
a) Wall Installation
Figure 3
14
Page 16
Operation Manual for Intelligent Speed Dome Camera
Figure 4
b) In-Ceiling Installation
Figure 5
2. Steps of Installation (taking wall-mounting as example)
1) Unpacking the carton and carefully take out the dome camera and its attachments.
2)
Rotate the vitreous cover counterclockwise and take out it. (see Figure 6) Note: It can
be ignored the steps 2,3,4,5 while the protocol and address are matching with the
controller.
3)
Take out the black liner. (Figure 7)
4)
Based on the ID-CODE shown as Figure 2, set up the protocol used by the camera
and the baud rate as per the state according to Table 1. Check the address of the
camera to see if it is matched with that you need. If not, set the address of the dome
camera at corresponding position as per Table 1.
15
Page 17
Operation Manual for Intelligent Speed Dome Camera
Open
Figure 6 Figure 7
Fix the black liner (see Figure 8).
5)
black liner
Fixed the
black liner
Figure 8
6) Take out the cover of the wall-installed bracket.(Figure9)
7) Take out system control wires from the bracket(Figure 10).
8) Fix the bracket on the wall(Figure11).
Takedown the
Figure 9 Figure 10 Figure11
9) Aiming the "MARK" of the bracket to the "MARK“ of the flange, push the dome
upward to the end and rotate it with the direction of the arrow until it is clicked and
tightened.(Figure 12).
10) It's ok to fix the dome to the bracket with hexagon socket head cap screw(Figure 13).
16
Page 18
Operation Manual for Intelligent Speed Dome Camera
MARK
LOCKOPEN
PUSH
Figure 12 Figure 13
11)
Rotate the vitreous cover clockwise and mount it(Figure 14)
12)
Connect the control wires of the system as per Figure 15.
Figure 14
RED CONNECTOR
RED LINE(AC24V IN)
BLACK LINE(AC24V IN)
ORANGE LINE(RS485+)
YELLOW LINE(RS485-)
(POWER IN)
BLACK CONNECTOR
(RS485 CONTROL IN)
Green: Y-OUT or SD Video out
Blud: Pb-OUT
Red: Pr-OUT
Blue:ALARM-IN
Green:ALARM-IN COM
Figure 15
3.Steps of Installation for Indoor Ceiling Style
1) Unpacking the carton and carefully take out the dome camera and its attachments .
2) Take out of the bracket, and fix the bracket on the wall.(Figure16).
3) Please connect the system control wires, video wires, power wires with the bracket
and go through it. Aiming the "MARK" of the bracket to the "MARK“ of the
flange, push the dome upward to the end and rotate it with the direction of the
17
Page 19
Operation Manual for Intelligent Speed Dome Camera
arrow until it is clicked and tightened(Figure17).
4) And then, please fix the dome to the bracket with bolts.(Figure18).
Figure16 Figure17 Figure18
4.To ensure a smooth and successful installation, you must:
1) Have electrical work comply with latest national electrical code, national fire code, and all
applicable local codes and ordinances.
Coordinate work with other trades to avoid interference.
2)
Verify existing site conditions and coordinate with owner’s representative and appropriate
3)
utilities as required.
Obtain copies of all related plans, specifications, shop drawings and addenda to schedule
4)
and coordinate related work
Thoroughly review the project to ensure that all work meets or exceeds the above
5)
requirements. Bring alleged discrepancies to the attention of the CCTV Project
Coordinator.
Ⅴ. Technical data table
1、 Indoor/Outdoor Speed Dome
Power supply AC24V 50/60Hz
Power consumption 35W max
Sync system Internal
Preset 128 presets
Patrol 6
Auto pan scan 360°Programmable
Pan Manual Control Speed 0—180°/s
Pan Preset Speed 300°/s max
Pan rotation range 360°continues
Title range 90°
Tilt Manual Control Speed 90°/s
Tilt Preset Speed 120°/s
18
Page 20
Operation Manual for Intelligent Speed Dome Camera
Precision
Control mode RS485
Baud Rate 2400/4800/9600/19200 bps
Fan & heater Fan & heater auto-start (only outdoor dome)
Environment temp
2、 Camera Optional data table
Effective picture elements Approx.2,000,000 pixels
Video signal
Lens
Digital zoom 12X(120X with optical zoom)
Angle of view(H) Approx.50 degree(WIDE end) to Approx.5.4 degree(TELE end)
On power cannot self-check
have image but have motor
noise
Self-check ok, but have no
image
Self-check ok but cannot
control
Vague image
On power cannot control
±10.5dB
HD: ANALOG COMPONENT(Y/Pb/Pr)
SD:VBS
Power supply fault Replace
Bad connection of the power Make correction
Transformer damaged Replace
Mechanical failure Repair
Camera incline Reinstall
Power supply not enough Replace
Video signal fault Reinstall
Bad connection of the video Press to full connect
Camera damaged Replace
RS485 Bus bad connection Check the RS485 connection
Dome id setting is wrong Reselect
Protocol setting is wrong Reset and on power again
Bad connection of the video Press to full connect
Power supply not enough Replace
Self check error On power again
Bad connection of control Press to full connect
Bad control of matrix On power again
Appendix Ⅰ: Lightning Proof and Surge Signal Proof
19
Page 21
Operation Manual for Intelligent Speed Dome Camera
The product adopts TVS lightning proof technology to prevent from damage by lightning strike below 1500
W and impulse signals such as surge; but it is also necessary to abide by the following precautions to ensure
electrical safety based on practical circumstances:
z Keep the communication cables at least 50 meters away from high voltage equipment or cables.
z Make outdoor cable laying-out under eaves as possible as you can.
z In open area shield cables in steel tube and conduct a single point ground to the tube. Trolley wire is
forbidden in such circumstances.
zIn strong thunderstorm or high faradic zone (such as high voltage transformer substation), extra strong
lightning proof equipment must be installed.
zTake the building lightning proof requirements into account to design the lightning proof and
grounding of outdoor equipment and cable laying-out in accordance with the national and industrial
standards.
zThe system must be grounded with equal potentials. The earth ground connection must satisfy the
anti-interference and electrical safety requirements and must not short circuited with high voltage
electricity net. When the system is grounded separately, the resistance of down conductor should be
≤ 4Ω and the sectional area of down conductor should be ≤25mm2 (refer to Figure 19).
Figure 19
Appendix Ⅱ: The Cleaning of Clear Down Cover
To obtain constant clear videos, user should clean the down cover periodically.
zBe cautious when cleaning. Hold the down cover ring only to avoid direct touch to the acrylic down
cover. The acid sweat mark of fingerprint will corrode the coating of down cover and scratch on down
cover will cause vague images.
z Use soft dry cloth or the substitute to clean the inner and outer surfaces.
z For hard contamination, use neutral detergent. Any cleanser for high grade furniture is applicable.
Appendix Ⅲ: RS485 Bus Basic Knowledge
1. Characteristics of RS485 Bus
20
Page 22
Operation Manual for Intelligent Speed Dome Camera
As specified by RS485 standards, RS485 Bus is of half-duplex data transmission cables with
characteristic impedance as 120Ω. The maximum load capacity is 32 unit loads (including main
controller and controlled equipment).
2. Transmission distances of RS485 Bus
When user selects the 0.56mm (24AWG) twisted pair wires as data transmission cable, the maximum
theoretical transmitting distances are as follows:
Baud RateMaximum Transmitting Distance
2400 Bps 1800m
4800 Bps 1200m
9600Bps 800m
If user selects thinner cables, or installs the dome in an environment with strong electromagnetic
interference, or connects lots of equipment to the RS485 Bus, the maximum transmitting distance will
be decreased. To increase the maximum transmitting distance, do the contrary.
3. Connection and termination resistor
The RS485 standards require a daisy-chain connection between the equipment. There must be
termination resistors with 120Ωimpedance at both ends of the connection (refer to Figure 20).
Please refer to Figure 21 for simple connection. “D” should not exceed 7m.
120Ω120Ω
1#2#3#4#32#
. . . . .
Figure 20
A+
.....
.....
120Ω
D
Main contr oller
B-
A+B-
120Ω
1#2#3#31#
Figure 21
The connection of 120Ω termination resistor: The termination resistor is ready on the Protocol PCB.
There are two kinds of connection. Refer to the Protocol PCB jumper setting form (refer to Picture 2).
1) In the Picture it is the factory default connection. The jumper is seated on Pin2&Pin3 and the
termination resistor is not connected.
2) when connecting the 120Ω termination resistor, user should plug the jumper on Pin1&Pin2. and
the termination resistor is connected.
4. Problems in practical connection
In some circumstances user adopts a star configuration in practical connection. The termination
resistors must be connected to the two equipment that are farthest away from each other, such as equipment
1# and 15# in Picture 44. As the star configuration is not in conformity with the requirements of RS485
standards, problems such as signal reflections, lower anti-interference performance arise when the cables
are long in the connection. The reliability of control signals is decreased with the phenomena that the dome
does not respond to or just responds at intervals to the controller, or does continuous operation without stop
(refer to Figure 22).
21
Page 23
Operation Manual for Intelligent Speed Dome Camera
Figure 22
In such circumstances the factory recommends the usage of DR-HB16 RS485 distributor.
The distributor can change the star configuration connection to the mode of connection
stipulated in the RS485 standards. The new connection achieves reliable data
transmission (refer to Figure 23).
MC2080
A+
B-
120Ω
120Ω
120Ω
Figure 23
1#
2#
. . . .
16#
Appendix Ⅳ:
Wire Diameter and Transmission Distance Comparison Chart