COP-USA AS75W User Manual

Page 1
MEDIUM DUTY
PAN/TILT UNIT
V1.1
Please read the operation manual carefully
before installing and using
Page 2
SAFETY PRECAUTIONS
CAUT I ON:
TO REDUCE THE RI SK OF EL ECTRI CAL SHOCK, DO DOT OPE N COVE RS. NO USER SERVI CEABL E PARTS I NSI DE. REF E R S ERV I CI NG TO QUAL I FI ED SERVI CE PERSONNEL
The l i ght i ng f l ash wi t h a ar r owhead symbol , i n an equi l at er al t r i angl e, i s i nt ended t o al er t t he user . Ther e i s uni nsul at ed “ danger ous vol t age” pr esence near by t he pr oduct ' s encl osur e whi ch may be r i sk of to persons .
CAU T I ON
RI SK OF ELECTRI C
SHOCK. DO NOT OPEN!
The excl amat i on poi nt wi t hi n an equi l at er al triangle is intended to alert the user to reference of t he i mpor t ant oper at i ng and mai nt enance ( ser vi ci ng ) i ns t r uct i ons .
THE PRODUCT CODE MARKED ON T HE BOTTOM COVER. PL EASE FI LL THE CODE I N THE FOLLOWING BLANK. PLEASE SAVING THI S SPECI FI CATI ON CA RE F UL L Y , S O THAT CHECKING.
MODEL: ________________________
PRODUCT C ODE: ________________________
Page 3
INDEX
I. IMPORTANT SAFEGUARDS……………………………………1 II. Summarize………………………………………………………..1 III. Setting of P/T……………………………………………………….1
3.1 Address setting of P/T ……………………………………….1
3.2 Setting of terminal resistance…………………………………2
3.3 Setting of communication protocol…………………………2
3.4 Setting of baud rate…………………………………………….3
IV. CONNECTION DETAILS……………………………………….4
4.1 Connection P/T with controller……………………………..5
4.2 Connection P/T with outdoor housing………………………..5
4.3 Control wiper…………………………………………………..5
V. SETTING PAN/TILT END………………………………….5
5.1 Setting the Pan limits……………………………5
5.2 Setting the TILT limits…………………………..5
VI. Installat ion……………………………………………………..6 VII. SPECIFICATIONS……………………………………………6
Page 4
I. IMPORTANT SAFEGUARDS
a) This apparatus must be connected to Earth. This installation should be made by
made by a qualified installer.
b) Do not carry out electrical installations in wet weather conditions. c) Voltage must to be matched with P/T. d) Examining connection , to sure that is correct. e) Please not to put the P/T with auto scanning continuouly for long time.
II. Summarize
This unit is a hi-tech CCTV product which incorporates panoramic speed-variable PAN/TILT, multifunctional decoder, CPU processor, memory chip into a whole. It can largely reduce connection and installation processes of components in the system, rise up reliability of the system and facilitate installation and maintenance. Therefore it has advantages of beautiful appearance, compact structure and easy operation.
1Integrated Multi-Protocol Decoder
a.
With integrated decoder and multi-protocol, it can integrate 16 kinds of communication protocols in maximum. As its baud rate of communication can be adjusted, it is compatible with many nor mal systems by easy setup inside the dome camera, so it has stronger versatility.
b.
RS485 serial control: addresses of unit 1-511.
2Integrated Speed-Variable PAN/TILT
a. Turning
-90 -- +20º vertically with a speed up to 10 rad/s.
Running stably at low speed with super lower noise. Pictures have no shaking.
b.
3High Intelligent Degree
a. b.
c.
4Could to be cooprated with outdoor housing ,also could contr ol camera that in housing
a. Camera’s iris、focus、zoon could to be manual controlled. b. Control auto iris shutter speed.
c. Auto white balance tracking.
0--355ºhorizontally and an adjustable speed from 0.25 - 10 rad/s; turning
As much as 64 preset positions can be preset with powerless memory The P/T can scan horizontally between two points and scan speed can be modified.
Six sets of programmable tour locus with 16 position each set. The running speed and the detention time are adjustable respectively ;
III. P/T SETUP
1ADDRESS SET
1
Page 5
ON
SW1
SW2
ON
12345 678910
DI P- - DI P9 :
Ad d r e s s Se l e c t
ON
12345 678910
120Ω terminal resistor i s connectedonRS485Bus
12345 6
Pr ot ocol Sel ect
ON
1234 5678 910
120Ω termi nal resistor i s opened f or RS485 bus
Figure 1
As shown in Figure 1, SW1 is used to set address of the P/T from 1 – 511. The ID-CODE from DIP-9 to DIP-1 are equivalent to a 9-bit binary digit. DIP-9 is MSB while DIP-1 is LSB. The state “ON” of each bit means 1 while “OFF” means 0. Following table shows states of coding switches of some addresses.
P/T
Address
DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8 DIP9 1 ON OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF OFF
10 OFF ON OFF ON OFF OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF OFF
511 ON ON ON ON ON ON ON ON ON
Status of ID-CODE
T able 1
For Example:
2
Page 6
ON
ON
ON
1234 56
78 910
1234 56
78 910
123456
78910
P/ T Addr ess=1 P/ T Addr ess=2 P/ T Addr ess=3
ON
1234 56
78 910
P/ T Addr ess=4 P/ T Addr ess=5
2Selection of the Terminal Resistor
ON
1234 56
78 910
ON
123456
P/ T Addr ess=511
78910
As shown in Figure 1, DIP10 of the ID-CODE is the select switch of the 120Ω
terminal resistor on the bus RS485, on which only one ter minal resistor of the dome camera at the farthest end can be connected, while the terminal resistors of other devices should be opened.
3、 Setup of the Protocol and the Default Baud Rate
As shown in Figure 1, SW2 is used to set the protocol of communication and the baud rate used by the dome camera. DIP-4 to DIP-1 of SW2 is used to select protocols and 16 different protocols can be selected in maximum. Following table shows states
of coding switches of protocols selected by the dome camera in which
means the
protocol has been integrated while
T ype of Protocols
DIP1 DIP2 DIP3 DIP4 DIP5 DIP6
means the protocol is temporarily vacant.
Selection of Protocols Normal Baud Rate
Integrated
Protocol
SAMSUNG ON OFF OFF OFF OFF ON NEON ON OFF OFF OFF OFF ON Reserved OFF ON OFF OFF OFF ON PELCO-D ON ON OFF OFF OFF OFF
PELCO-P/4800 PELCO-P/9600 OFF ON
OFF OFF ON OFF
ON OFF
PANASONIC ON OFF ON OFF OFF ON Longcomity OFF ON ON OFF OFF ON HUNDA600 ON ON ON OFF OFF ON LILIN OFF OFF OFF ON ON OFF VICON ON OFF OFF ON ON OFF MOLYNX OFF ON OFF ON OFF ON
KALATEL ON ON OFF ON ON OFF VCL OFF OFF ON ON OFF ON DAIWA ON OFF ON ON OFF ON ALEC OFF ON ON ON OFF ON Ultrak ON ON ON ON OFF ON
Table 2
Some protocols and the states of the coding switches of normal baud rate of these
3
Page 7
protocols are shown as follows:
NE ON/ 9600Bps
PEL CO- D/ 2400Bps
PEL CO- P/ 4800Bps
PEL CO- P/ 9600Bps
ON
123456
ON
123456
ON
123456
ON
123456
PANASONI C/ 9600Bps
KAL ATE L / 4 8 0 0 Bp s
ALEC/ 9600Bps
Ul t r ak/ 9600Bps
ON
123456
ON
123456
ON
123456
ON
123456
4Setup of the Baud Rate of Communication. As shown in Figure 1, SW2 is
used to set the protocol of communication and the baud rate used by the dome camera. DIP-6 and DIP-5 of SW2 are used to select the baud rate of communication and 4 different baud rates can be selected in maximum. If the controller adopts non-standard baud rate, you can adjust it to be identical with that of the controller as per the following table.
Baud Rate of Communication 2400bps OFF OFF
4800bps ON OFF 9600bps OFF ON 19200bps ON ON
Setup of Baud Rate
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6
T able 3
. CONNECTION DETAILS
Notice: Before carrying out any electrical installation ensure that the cable being used in at the
correct voltage and current rating for the application.
4
Page 8
Figure 2
1. Connection P/T with controller RS485 control signal power supply(AC24V)、video
signal could connect with controller by air waterproof connector plug (D1). Figure 4 is Connect way of D1. Figure 3 is come out line of air connector plug.
RED
BL ACK ORA NGE
YEL L OW
VI DEO
RED: A C2 4 V I N BL ACK: AC24 V I N ORANGE: RS48 5 + YEL L OW: RS485­VI DEO: VIDEO OUT
Figure 3
2. Connection of P/T and outdoor housingwhen collocate the special decoder for housing,
decoder’s control signal input、Power supply(AC24V) and video signal output by air
waterproof connector plug (D2) to conncet . Figure 5 is connect way of D2. Note:Connect
P/T’s GND with lens decoder ’s GND. Furthermore P/T’s TXDRXD must cross connect
with lens decoder’s TXDRXD,Otherwise,lens will not to be controlled. Otherwise,Could not to preset lens’s position,only just could preset P/T’s postision.
1
4
6
1. AC24V I N
2. AC24V I N
3. RS485-
4. CABI NET GND
3
5. RS485+
6. VI DEO+
7. VI DEO-
D1
2
5
7
D2
2
5
7
1 . AC2 4 V OUT 2 . AC2 4 V OUT
3. TXD( TTL LEVEL)
1
4. GND
34
5. RXD( TTL LEVEL)
6
6. VI DEO+
7. VI DEO-
Figure 4 Figure 5
3. Control wiperUse commandD-ZOOM ONto startup wiperUse command
D-ZOOM OFFto stop wiper. Also could use call NO.64 preset position to startup or
stop(switch controll) wiper.
. SETT ING PAN/TILT END
a、 Setting the Pan limits (see figure 6)::Loosen the M4 screws and loosen the pan strikers. Adjust
the strikers until they are at the position to strike the relevant actuator, thus activating the limit switches. Tight en th e M4 screws to secure the pan strikers.
bSetting the Tilt limits (see figure 7)Release the screw locks and adju st the strikers until they
are at the position to strike the actuator, thus activating the limit switches.
5
Page 9
Figure 6 Figure 7
Ⅵ. INSTALLATION
a This outdoor Pan/Tilt unit is intended to be mounted on a wall mount. The unit base has 4
holes equi-spaced on 4(101.6mm) P.C.D[see figure 8], which line up with the bracket
mounting holes. Mount the unit base onto the bracket using the four M6×25 Hex head screws, 6mm washers and the M6 nuts provided in the packing kit.
b Remove the six M4mm fixing screws from the top platform using the three M1/4″ -20screws
(supplied). Secure the Sub-plate to the base of the Camera Housing [see figure 1]. Secure the sub-plate (with camera housing attached) with the six 6mm fixing screws removed earlier.
Figure 8
. SPECIFICATIONS
Input Voltage: AC 24V
Angular Travel: Pan 350°
Tilt +20°~ -90° (OTT MOUNT)
Speed: Pan 0.25°~ 10°/second
Tilt 0.25°~ 10°/second Limit Stop: Externally adjustable
Load Rating: 15Kgs (OTT MOUNT)
Operating Temperature: -35℃~+60℃ Construction: Aluminum alloy casting
Measurement: 225(L)×180(W)×260(H)(OTT MOUNT) Unit Weight: 10 Kg