COP-USA AS20RS485 User Manual

Page 1
Indoor / Outdoor Pan/Tilt System
IFeatures:
z Compact and attractive appearance, Indoor / Outdoor design
z Motor running stably
z Flame-retarded ABS material
z Adjustable horizontal limit switcher, the unit capable of operation with load to 6Kg
z RS485 data communication
z With internal decoder, Multi-protocol, baud rate for selectable
z With line scanning function
IIDescription of the Dip-switcher setting:
1.Dip-switcher
SW2SW1
ON DIP
1 2 3 4 5 6
6-Dip switcher: 1 – 4 for Protocol, 5 – 6 for Baud rate
10-Dip switcher(frontal 9-DIP) is for the address setup:1511, count it as the binary system.
2 The setting of the protocol and the default baud rate:
Protocols
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 SAMSUNG ON OFF OFF OFF OFF ON B01 ON OFF OFF OFF OFF ON PELCO-D ON ON OFF OFF OFF OFF PELCO-P/4800 PELCO-P/9600 OFF ON
OFF OFF ON OFF
Longcomity OFF ON ON OFF OFF ON HUNDA600 ON ON ON OFF OFF ON LILIN OFF OFF OFF ON OFF ON
ON DIP
1 2 3 4 5 6 7 8 9 10
Selection of Protocols Normal Baud Rate
ON OFF
Page 2
ALEC OFF ON ON ON OFF ON
3 The setting of the baud rate:
Dip-switcher
Baud Rate
2400bps OFF OFF 4800bps ON OFF 9600bps OFF ON
19200bps ON ON
B01/ 9600Bps
AELC/ 9600Bps
PEL CO- P/ 4800Bps
4 Address setting
Dome
Address
10 OFF ON OFF ON OFF OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF OFF
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 DIP-7 DIP-8 DIP-9
1 ON OFF OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF OFF
ON
123456
ON
123456
ON
1234 56
1 2 3 4 5 6
ON
SAMS UNG/ 9600Bps
PEL CO- D/ 2400Bps
PEL CO- P/ 9600Bps
123456
ON
123456
ON
123456
Dip-switcher
Page 3
511 ON ON ON ON ON ON ON ON ON
Before the application of the Dome pan/tilt, the address codes should be set first by DIP1 to DIP9 of SW1 on PCB in binary 8421 coding system, in which DIP1 means lower bit and the maximum address is 511. State ON of the “1” while OFF means “0”. Some address codes of the
DIP-SWITCH are set as above.
DIP-SWITCH means
5. Selection of 120Ω Terminal Resistor
The DIP-10 of SW1 is used to select 120
reflection of echo wave in communication circuit, you can connect a 120
resistor in parallel between 485+ and 485- of the Do me (set the selection bit of 120
Ωterminal resistor. In order to remove the
Ωterminal
Ω
terminal resistor at ON). The standard of RS485 industrial bus requires all equipment should be connected in daisy-chain style and both ends should be connected with 120
Ωterminal resistor (see Figure 5). The simplified connection can be done as Figure 6
but distance “D” couldn’t be larger than 7 meters.
120Ω 120Ω
1# 2# 3# 4# 32#
. . . . .
<Figure 5>
IIIDimension:
Page 4
84. 4
180
IVThe facility system connection:
21 21
1/ 4’ × 20
8
7
Φ
180. 8
8
.
RS4 8 5
RS 4 8 5
VDescription of the line out:
RS4 8 5
RS4 8 5
RS 4 8 5
Page 5