█ Select Protocol of the Keyboard
1. Protocol Setting: press [CALL]+[200]+[ON], LCD will show “Display: Select Protocol ”, and turn the
joystick left or right to select the protocol you wanted, press [ Enter] to save the protocol.
2. Protocol type:
◆ PELCO-D 2400bps ◆ PELCO-D 4800bps
◆ PELCO-P 4800bps ◆ PELCO-D 9600bps
◆ PELCO-P 9600bps
◆ COP-2 9600bps
█ Operation of the Keyboard
1. Select Address of the Speed Dome Camera:[CAM]+[N]+[Enter]
Display: Current CamID:001
Description:N –– No. of camera from 0 to 255
Function:Select the address of the camera to be controlled. When the value N is in conformity with the
address of the Speed Dome Camera, it will be under control.
2. Set the Preset Position:[PRESET]+[N]+[ Enter]
Display:Preset No:001
Description:N –– No. of preset position from 1 to 255.
Function:Store current position and refer it as No. N position.
3. Call the Preset Position:[CALL]+[N]+[ Enter]
Display:Call Number:001
Description::N –– No. of preset position from 1 to 255.
Function: Transfer the camera to the position of No. N preset position.
4. Cancel the Preset Position:[PRESET]+[N]+[OFF]
Display:Preset No:001
Description:N –– No. of preset position from 1 to 255.
Function:Delete the No. N preset position stored.
5. Set the Cruise Track (COP-2, PELCO-D, PELCO-P Available):
◆ Enter the Status of Track Setting:[SHOT]+[N]+ [ON] (N:No. of track from 1 to 6).
Display:Track = 01 Sum = 06
Description:Track No.1 is currently setting, in which there are 6 preset points.
◆ Edit Track:Press [TELE] to edit down page and press [WIDE] to edit up page. Each track involves 16 preset
points and the running speed and the dwelling time of each preset position.
Display:No.:01 Point:001 → Description:The 1st preset position in the track is 001.
Display:No.:01 Speed:001 → Description:The speed of the 1st preset point in the track is the 1st class.
Display:No.:01 Time: 004 → Description:The dwelling time of the 1st preset point in the track is 4
Seconds
◆ Speed Range:1 to 8 from the fastest to the lowest. Any speed outside the range will be referred as the 1st