CopperSmith CSRB-6, CSRB-10, CSRB-8 Installation Instructions Manual

Models:
CSRB-6 CSRB-8
CSRB-10
CONTENTS:
INSTALLATION INSTRUCTIONS
CopperSmith Remote Blower / Ventilators
READ AND SAVE THESE INSTRUCTIONS
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Installer:
Owner:
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manu­facturer.
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
Please leave these installation instructions with the range hood installation instructions. Please leave these installation instructions for local electrical inspector’s use and for future reference.
WARNINGS: Must be followed carefully to avoid personal injury.
IMPORTANT: Must be followed carefully to avoid damage.
TIPS: Contain helpful information to facilitate installation.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16 Page 1
CAUTION: For General Ventilation Use Only. Do Not Use To Exhaust Hazardous or Explosive Material and Vapors.
CAUTION: This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals. WEAR HAND PROTECTION AND STAY CLEAR OF SHARP EDGES! The compactness and adaptability of the model PSD blower permits easy installation. The units are shipped fully assembled and can be mounted at any angle. For mounting suggestions see pages 3 & 4. Because this unit has rotating parts, safety precautions should be exercised during all phases of installation, operation and maintenance. Remove unit from package and inspect before installation. If damaged, report damage to carrier. DO NOT operate this unit with visible damage to the blower or impeller assembly. Screen guards must be installed when blower will be within reach of personnel, within (7) feet of the working area, or when advisable for safety.
WARNING! DO NOT CONNECT POWER SUPPLY until blower is completely installed. Make sure electrical service to the blower is locked “OFF” position.
Check voltage at blower to see if it corresponds to the motor name plate. Installation work and electrical wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel
burning equipment, (e.g., gas water heater, gas furnace) to prevent back drafting.
Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted
blowers must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be
connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
NEVER place a switch where it can be reached from a tub or shower. All units are suitable for use with solid-state speed control.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) or fuel burning
equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Duct blowers must always be vented to the outdoors.
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16
Page 2
PART 1 Planning the Installation
For best and quietest performance, the Remote Blower should be installed in the attic, near or slightly
beyond the mid-point of the duct system. In installations requiring the blower be in a chase or hood over the range (e.g., no attic above the kitchen), the duct silencer will not be as effective in absorbing motor noise. In addi­tion, there will likely be motor sound transmitted through the walls of the chase, bypassing the duct silencer.
Given the high performance of CopperSmith Remote Blowers, it is highly recommended that the blower NOT be attached directly to the liner or in a chase immediately above the liner unless a CopperSmith brand duct silencer is installed between the blower and liner and neoprene lined FC Clamps* are used.
CopperSmith brand Professional Series ventilation systems can be installed in an infinite variety of configurations. The Remote Blower and Duct Silencer can be installed at any angle.
Connecting the Blower / Ventilator
er properly aligning and supporting the blower, connect it to the duct. Fasten in place by using sheet metal
Aft screws and tape or preferably FC Clamps*. Fast Clamps (FC Clamps) are the recommended connectors for connecting the blower to the duct system. FC Clamps are easy to connect and work extremely well as a vibration absorber and noise suppressor. They are made of steel and are lined with 0.3” neoprene pad. If FC Clamps are used to connect the blower to the duct, it is not as necessary to use them on the Duct Silencer for vibration suppression. FC Clamps are available from CopperSmith.
CAUTION: DO NOT hang PSD model blowers / ventilators from the FC Clamp’s hanging tabs. Instead, use the integral brackets bolted to the blower housing.
Hanger type vibration isolators and suspension hardware (e.g., threaded rod, slotted angle iron, hurricane strap) are not supplied with blower. If the blower is suspended with these items, they will absorb much of the motor’s minor vibration.
For more information about vibration absorbers, visit the following internet sites:
www.grainger.com (e.g., for WW Grainger Item 4C879) www.vibration-absorbers.com www.vibrationiso.com
*FC Clamps are available from CopperSmith.
Ask for model number FC6 (6”), FC8 (8”) or FC10 (10”), 2 per box.
-
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16
Page 3
Part 2 Securing the Blower / Ventilator
Mounting Illustration Option 1
Mounting Illustration Option 2
Follow all applicable codes when installing this unit.
1. Build and install wood supports to framing structure for blower mounting.
2. Attach blower directly to wood supports.
The Remote Blower’s mounting brackets are designed for flexible and easy installation at any angle-horizontal, vertical or diagonal. The brackets should be bolted directly to a 2” x 4” type wood framing structure (e.g., an attic truss) or suspended by threaded rod, slotted angle-iron or hurricane strap. The installation should be sufficient to support the blower’s weight.
Follow all applicable codes when installing this unit.
1. Equipment should be hung in position with temporary fixtures that can be removed after vibration hangers* are installed.
2. Optional vibration hanger may be fastened directly to the
Detail
*IMPORTANT NOTE: Hanger-type vibration isolators and suspension hardware (e.g., threaded rod, slotted angle iron, hurricane strap) are not supplied with blower. If the blower is suspended with these items, they will absorb much of the motor’s minor vibrations.
Vibration Mount
structure or somewhere between the suspended unit. Be sure not to over tighten the neoprene element. Install hangers.
3. If threaded rod is used, turn nuts on rod assembly clockwise one complete turn on each hanger. Repeat this procedure
until temporary hanging fixtures are loose and blower is
suspended completely on t
4. Remove temporary fixtures and level ducting and blower by taking additional turns on the spring / top hanger rod nut as required.
he vibration hangers.
For more information about vibration absorbers, visit the following internet sites:
www.grainger.com (e.g., for W.W. Grainger Item 4C879) www.vibration-absorbers.com www.vibrationiso.com
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16
Page 4
Part 3 Electrical Connection
Dimensions
3/4”
A B
C D
115 Volt Single Phase Fans
Green/Yellow
Motor Leads
Blue
Black
Brown
(Ground)
N (White)
L (Black)
Control
Voltage
Switch
In Hood
From
Dimensions Data & Amperage
Model A B C D Amps
13 6 8 1.26
WARNING:
Ensure the power supply is disconnected before proceeding.
Verify that the power supply matches the ratings found on the blower data label before proceeding.
The complete blower unit must be properly grounded at all times when electrical power is applied.
Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire must utilized.
2.99
4.84
be
Capacitor
Failure to complete electrical connections properly may result in damaged or non-functional systems. Follow instructions carefully to ensure proper installation.
Wiring Diagram (for connecting “Remote” blowers to CopperSmith Pro & Standard Series liners*)
120V Red
Ventilator
Green, Ground
Black 120 volt AC from electrical panel (usually black) to liner White Neutral from electrical panel (white) to liner
Green Ground from electrical panel (usually green) to liner Red 120 volt AC variable control from liner to 120 volt AC of variable speed ventilator (usually black)
CAUTION: Do NOTconnect this wire to a 3-speed blower.
White (N)
120V Black
(L)
Green
Liner Models:
CSPI Series CSCI Series
Excluding...
3-speed motor
House Electrical
Panel
models, which all
have a
-6 or -12
at the end of
model number.
Liner
BLK WHT GRN RED
It is the owner’s responsibility to ensure that a qualified person performs the electrical connection of this appliance. The electrical installa­tion, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Assoc., 1 Batterymarch Park, Quincy, MA 02269
Page 5CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16
W A R R A N T Y
Professional Series Kitchen Ventilation Products
What is Covered
CopperSmith warrants its CopperSmith Professional Series kitchen ventilation products to the original user, to be free of defects in materials and workmanship for three (3) years from the date of purchase.
CopperSmith, at its option, will repair or replace the complete unit or any defective component without charge. This warranty may be voided if any unauthorized service, alterations or repairs are made to the product.
What is Not Covered
Normal maintenance and service of any product that has been subject to misuse, negligence, accident or installation inconsistent with the recommended installation instructions. Product used other than for normal in-home use or products used outside of the United States. Damage to the product caused by accident, fire, flood or other acts of God. Service calls to educate the customer in the proper use and care of the product, correct faulty installation, change fuses or reset breakers.
CopperSmith disclaims and excludes any liability for implied warranties or for incidental or consequential damages wherever permitted by law. There are no implied warranties of merchantability or fitness for a particular use or purpose. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.
#
For Service
If you need service, contact Customer Service at the address or phone number below. Provide the model number, serial number, part identification, and details of the problem. Proof of purchase must be provided.
Warranty Rev. 09/18/16
CopperSmith has a policy of continuous improvements and reserves the right to modify (at anytime and without notice) any or all of its products, features, designs, components and specifications. For exact dimensions, see the Installation Instructions included with each product. Some features may be slightly different than shown on product literature.
For more information, please contact your dealer or CopperSmith
Phone: 1-888-431-4677
Email: support@worldcoppersmith.com
Website: worldcoppersmith.com
C US LISTED
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16