COPALTEC PURE CL 250 Datasheet

Page 1
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 1 of 7
1. Identification of substance/preparation and of the company/undertaking Product name: PUre Cleaner
Use of substance: As solvent or cleaner Manufacturer: copaltec GmbH
Otto-Lilienthal-Straße 33 71034 Böblingen, Germany Phone: + 49 7031 98 62 50 [email protected]
Emergeny phone: + 49 7031 98 62 50
2. Hazards Identification Classification of the substance or mixture
Classification (1272/2008/EC): The product is not classified according to the CLP regulation.
Marking elements:
None
Labelling (1272/2008/EC):
None
Danger warnings:
None
Safety instructions: None
Additional information:
None
Other hazards: Results of PBT and vPvB assessment
PBT: Not applicable vPvB: Not applicable
3. Composition/Information on the components Product type:
Substance
Dangerous Ingredients:
None
Page 2
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 2 of 7
4. First aid measures Description of first aid measures
General information:
Immediately remove soiled, soaked clothing and shoes. In case of irregular breathing or respiratory arrest, use artificial respiration. Rest and transport in recovery position. Symptoms of poisoning can only occur after many hours, therefore medical supervision at least 48 hours after an accident. After inhalation: Provide fresh air supply. If symptoms persist, consult a doctor. In case of respiratory arrest or irregularity, resuscitate or oxygenate and call a doctor immediately. If unconscious, store and transport in stable lateral position. After skin contact: In general, the product is not skin irritant. Wash off immediately with soap and water and rinse thoroughly. After eye contact: Rinse eyes with eyelids open for at least 10 minutes under running water. If symptoms persist, consult a doctor. After Swallowing: Rinse mouth and drink plenty of water. Do not induce vomiting, seek medical attention immediately.
Most important both acute and delayed symptoms and effects:
Sickness Breakout of sweat Dizzines Cramps Information for the doctor: Treat symptomatically, i.e. decontamination, vital functions
5. Fire-fighting measures Suitable extinguishing media:
Carbon dioxide (CO2), extinguishing powder or water spray. For larger fires, also fight with water spray or alcohol-resistant foam.
Specific hazards arising from the substance or mixture concerned:
None
Instructions for firefighting:
Respiratory protection with independent air supply required for firefighting. Fire residues and contaminated extinguishing water must be disposed of in accordance with official regulations.
Page 3
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 3 of 7
6. Accidental release measures Personal precautions, protective equipment and emergency procedures:
Ensure adequate ventilation. Keep ignition sources away. Use respiratory protection when exposed to vapours.
Environmental precautions:
Do not allow to enter drains, surface water, ground water.
Methods and materials for retention and cleaning:
Absorb with liquid-binding material (sand, diatomite, acid binder, universal binder, sawdust). Ensure adequate ventilation.
References to other sections:
No hazardous substances are used.
7. Handling and Storage Precautions for safe handling:
Ensure good ventilation/suction at the warehouse and workplace. Avoid contact with eyes and skin. Store in cool, dry conditions in well-sealed containers. Use solvent-resistant devices. Avoid aerosol formation.
Information on fire and explosion protection:
Keep ignition sources away - do not smoke. Provide fire extinguishers. Do not spray against flames or on glowing objects. Hot product develops flammable vapours.
Conditions for safe storage taking into account incompatibilities:
Provide solvent resistant and tight flooring.
Information on storage in one common storage facility:
Do not store together with oxidizing and acidic substances.
Further information on storage conditions:
Keep under lock and key or only accessible to experts or their representatives.
VCI bearing class (VCI = German Chemical Industry Association):
10 - Flammable liquids
Page 4
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 4 of 7
8. Exposure controls/personal protective equipment Components with work place-related limit values that are to be monitored:
The product does not contain any relevant quantities of substances with workplace­related limit values to be monitored.
Limitation and monitoring of exposure respiratory protection: General protection and hygiene measures:
The usual precautionary measures when handling chemicals must be observed. Wash hands before breaks and at the end of work. Keep away from beverages, food and animal feed. Remove soiled, soaked clothing immediately. Do not inhale vapours and spray mist.
Breathing protection:
Not required with good room ventilation.
Hand protection:
The glove material must be impermeable and resistant to the product / substance / preparation. Selection of the glove material taking into account breakthrough times, permeation rates and degradation.
Glove material:
The selection of a suitable glove not only depends on the material, but also on other quality features and varies from manufacturer to manufacturer.
Penetration time of the glove material:
The exact breakthrough time must be obtained from the manufacturer of the protective gloves and must be observed.
For permanent contact gloves made of the following materials are suitable: Butyl rubber
Eye protection:
Not required, but recommended.
Skin and body protection:
Solvent-resistant protective clothing
9. Physical and chemical properties Appearance: fluid
Colour: colourless Odor: weak, characteristic pH-Level: neutral Freezing: < -30 °C Boiling point/Boiling range: > 165 °C flash point: 65 °C Flammability: approx. 170 °C Danger of explosion: The product is generally not explosive, but the
formation of explosive vapour/air mixtures is possible.
Density: 0,90 g/cm³ (DIN 51757)
Page 5
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 5 of 7
Miscibility with water: not miscible or partially miscible Dynamic viscosity: < 1,0 mPa*s at 20 °C
Other information:
None
10. Stability and reactivity Chemical stability:
No decomposition if stored and used as intended.
Possibility of dangerous reactions:
Development of ignitable mixtures possible in air when heated above flash point and/or sprayed or nebulized.
Conditions to avoid:
None
11. Toxicological information Acute toxicity:
On the basis of the available data, the classification criteria are not fulfilled.
Primary skin irritant effect:
On the basis of the available data, the classification criteria are not fulfilled.
Primary eye irritant effect:
On the basis of the available data, the classification criteria are not fulfilled.
Sensitisation:
On the basis of the available data, the classification criteria are not fulfilled.
Main recording paths:
The main intake route is primarily through the respiratory tract.
CMR-effects (carcinogenic, mutagenic and toxic to reproduction):
No CMR-effects known.
Germ cell mutagenicity:
On the basis of the available data, the classification criteria are not met.
Carcinogenicity:
On the basis of the available data, the classification criteria are not met.
Reproductive toxicity:
On the basis of the available data, the classification criteria are not met.
Specific target organ toxicity at single exposure:
On the basis of the available data, the classification criteria are not met.
Specific target organ toxicity at repeated exposure:
On the basis of the available data, the classification criteria are not met.
Danger of aspiration:
On the basis of the available data, the classification criteria are not met.
Page 6
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 6 of 7
12. Environmental Information
Do not allow to enter water, sewage or soil.
Toxicity: Aquatic toxicity:
No further relevant information available.
Persistence and degradability:
Biodegradable.
Bioaccumulation potential:
No further relevant information available
Mobility in the ground:
No further relevant information available.
Further information on ecotoxicology: General information:
May not be discharged untreated into groundwater, water bodies or sewage systems. Negative ecological impacts are not to be expected on the basis of present knowledge.
Water hazard class (list classification):
1, slightly hazardous to water according to VwVwS
Results of PBT and vPvB assessment:
PBT: inapplicable vPvB: inapplicable
13. Notes on disposal Waste treatment process:
Referral:
Do not dispose of together with household waste. Do not empty into drains.
Waste code number:
VeVa-Code: 16 03 05 (organic wastes which may contain dangerous substances)
Uncleaned packaging: Referral:
Return the contents/container to the point of sale or to a collection point for hazardous waste.
Recommended cleaning agent:
Liquor
14. Transport details UN number:
ADR, ADN, IMDG, IAT, not applicable
Proper UN shipping name:
ADR, ADN, IMDG, IAT, not applicable
Page 7
Material Safety Data Sheet
According to regulation (EC) No. 1907/2006 PUre Cleaner
Date of issue 01.08.2019, Version 1
Page 7 of 7
Transport hazard classes:
ADR, ADN, IMDG, IAT, not applicable
Packaging group:
ADR, ADN, IMDG, IAT, not applicable
Environmental hazards: Marine pollution:
No
Transport in bulk in accordance with Annex II of MARPOL 73/78 and the IBC Code:
Not applicable
Transport/further information:
No dangerous goods according to the above regulations
UN „Model Regulation“:
not applicable
15. Legislation Safety, health and environmental protection/legislation specific to the substance
or mixture:
Directive 2012/18/EU Hazardous substances named - ANNEX I None of the ingredients is included.
Water hazard class:
Class B (self-classification)
Chemical safety assessment:
A chemical safety assessment has not been carried out
16. Other disclosures
The above information in this safety data sheet corresponds to the current state of our knowledge and experience and is intended to provide indications for safe product handling and does not constitute a contractual legal relationship. The data relevant for processing must be taken from the technical data sheet. The data are not transferable to other products. If the product specified in this safety data sheet is mixed, blended or processed with other materials, they cannot be transferred to the new material.
Loading...