Oct,
2005
General specifications
Display
Power
Switch output
Item Model number
PS30
102R 103R
■ STANDARD SPECIFICATIONS
Pressure reference
Gauge
Non-corrosive gases
−100 ~ 100 −100 ~ 1000
200 1500
500 2000
−10 ~ 50
0 ~ 50
35 ~ 85 (No condensation)
−20 ~ 70 (Atmospheric pressure, humidity 65 %RH maximum)
Approx. 60 (Including 1.5 m cable)
12 ~ 24 V ± 10 % (Including ripple voltage)
40
±3 %F.S. (0 ~ 50 °C)
100 (DC500 V)
500 V AC, 60 s (Leakage current 1 mA maximum)
M5 female screw, “O” ring groove (P8)
LED (2 and 1/2 digit
)
−100 ~ 100 ———
——— −0.10 ~ 1.00
±1 %F.S.
1 count
NPN or PNP transistor, open collector output
30 V DC 100 mA maximum
Short-circuit protection
1.2 V (NPN), 2.2 V (PNP)
Output 1 (SW1), Output 2 (SW2) Light on when output is ON.
0 ~ 30 counts (Adjustable)
±0.3 maximum
Approx 5, 25, 250 (Adjustable)
2
Pressure medium
Rated pressure range kPa
Maximum pressure kPa
Break-down pressure kPa
Operating temp. range °C
Compensated temp. range °C
Operating humidity %RH
Storage temp. °C
Net weight g
Supply voltage V DC
Consumption current mA maximum
Thermal error
Insulation resistance MΩminimum
Dielectric strength
Pressure port
Display element
Rated display range
kPa
MPa
Display accuracy
Resolution
No. of outputs
Output interface
Switching capacity
Residual voltage V maximum
Display
Switch
hysteresis
Repeatability %F.S.
Response ms
● Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
PS30
PRESSURE SWITCHES WITH GAUGE
❈1 : Change in the pressure indication, switch operating points.
■ ENVIRONMENTAL CHARACTERISTICS
Test item
Test conditions Permissible change
± 2 %F.S. maximum after test ❈1
Vibration
10~500 Hz, 98.1 m/s2or 1.5 mm P-P, 3 directions for 2 hours each
490 m/s
2
, 3 directions for 3 times each
0 ~ Rated pressure、106cycles
40 °C, 90 ~ 95 %RH, 240 hrs.
EMI : EN 55011 Group 1, class B (1991)
EMS : EN 61326-1
± 5 %F.S. maximum during test ❈1
Shock
Pressure cycling
Moisture resistance
EMC