ADDRESS
Set the address of the keypad to 1, 2, 3 or 4 by fit
ting the jumper across the appropriate link, or set to
address 5 by leaving the jumper off. The maximum
number of keypads depends on the panel type and network number; please see the Engineering Manual. No
two keypads on the same network can have the same
address. Re-apply power after changing the address.
If the keypad is on network 1 or attached to the panel’s
Engineer Keypad port then you can leave the jumper
off to make the keypad an Engineer Keypad. Discon
necting an Engineer keypad from the panel does not
cause a tamper alarm.
Wiring and Link Instructions
BACK LIGHT
Jumper not fitted
(default)
– Display and keypad back
lights are normally off. When
a key is pressed, the lights
will switch on at full brightness for 5 seconds.
Jumper fitted – Display
and keypad back lights are
permanently on at half brightness. When a key is pressed,
the lights will switch on at full
brightness for 5 seconds.
WARD SNDR
If the keypad output
is programmed as
type Sndr Ctl, fitting
the jumper enables
the sounder to operate only for a selected
ward. Please refer to
the Engineering Manual for further details.
VOLUME CONTROL
Adjusts volume of
internal sounder and
external loudspeaker.
LED MIMIC
Jumper fitted: red LED on
front of keypad glows when
keypad output is on. By
default, the output type is
“Pending”: LED glows when
there are two outstanding
alerts.
Jumper removed: LED stays
dark.
MASK
By default, this link should be fit
ted. Leave the link disconnected
if the panel has firmware earlier
than version 1.06, or if the keypad is connected to an XNode.
By default, “O/P” is normally
at 12Vdc, and switches to 0v
when active. Sense can be
inverted when programming
the output.
Single 16 Ohm external loudspeaker
(follows internal sounder). Volume is
adjustable using VR1.
To next keypad (max. 3, 4
or 5 keypads depending
on network; see the Engi-
neering Manual)
7/0.2 unscreened alarm cable is normally used.
Screened cable may be needed in areas with
high levels of radio frequencies; refer to control
panel Installation Instructions.
Supply voltage must not drop
below 10.5V at each keypad
(12V min. recommended). The
spare core can be used to double up “B” (0v) to reduce voltage
drop.
Keypads can connect in
a daisy-chain or star configuration.
If connected to Network
3-8 on the panel, the “D”
connection must be taken
from Network 1 or 2.
If the sensor has an anti-masking facility, a single zone using three resistors
can convey all states (healthy, alarm,
masked and tamper). The zone can be
programmed as any type (e.g. Normal
Alarm), but must have the “Masking”
attribute.
Anti-masking must be used only
if the panel has firmware version
1.06 or later. Fit the MASK link (see
opposite). Anti-masking is not supported if the keypad is connected to
an XNode.
FSL enables supervision of cable tampers. The
resistors can take any of the following values
(specify the values when programming the zone).
Alarm Shunt
Resistor
End-of-Line
Resistor
4k7 2k2
1k0* 1k0*
4k7* 4k7*
2k2* 2k2*
*Not supported for a keypad connected to an
XNode.
Double-pole wiring is also known as
Closed-Circuit Loop (CCL).
Zone Wiring (Optional)
Connect the alarm sensor using one of the following methods. Contacts are normally closed; if normally open, program zone with the “Inverted” attribute.
Note: If powering the sensor from the keypad, an additional two cores are required for connection
to the A (+12Vdc) and B (0V) terminals on TB1. Check the panel’s Installation Instructions for power
availability figures.
Fully-Supervised Loop (FSL) Wiring:
Anti Mask Wiring:
Network Wiring
Keypad address = 2 Keypad address = 1
Control Panel or
MSNODE
Max. 100m to furthest keypad
Loudspeaker
Wiring (Optional)
Output Wiring
(Optional)
Keypad PCB
Tamper
Anti-mask
Alarm
Alarm
Tamper
Tamper
Alarm
Double-Pole Wiring
Other examples of output
devices
Diode (IN4001)
12V Buzzer
Zone 1
Zone 2
Zone 1 and 2 can
use different wir
-
ing methods.
EXTERNAL PROX
WIRING (MKP3 only)
Connect AX10 proxim
ity reader to this terminal as shown.
50m Max.
RED
WHITE
BLUE
BLACK
To AX10