Cooper Power Systems 500LG User Manual

RFN-500LG User’s Guide
Document Number
XXXX
Revision 1
Eaton’s Cooper Power Systems
Gaithersburg, MD 20878 USA
www.eaton.com
Tel (301) 515-7118
Fax: (301) 515-4965
Contents
1 About the RFN500LG ............................................................................................................................. 3
2 Regulatory Notices................................................................................................................................. 4
3 RFN500LG Specifications ..................................................................................................................... 7
XXXXX-01 2 RFN-500LG User’s Guide
1 About the RFN-500LG
The RFN-500LG is a radio communications device designed for use in L+G Focus meters. It can also be used in Eaton’s Cooper Power Systems Gateways and Relay Nodes. The RFN-500LG provides a 915 MHz radio interface to an RF mesh network.
The RFN-500LG operates from a power source of 120 VAC to 277 VAC, received from the host device. It may also be powered from a 12VDC power source. The supplied voltage is then regulated to 5.0 VDC and 3.3VDC by the on-board power supply circuit. The radio modules operate in license-free bands at 915 MHz (902.75 to 927.25 MHz). RFN-500LG Nodes are fully compatible with mesh network hardware, protocols and operations. Five radio transmission data rates are available: 9.6 kb/s, 19.2 kb/s, 38.4 kb/s, 76.8 kb/s and 153.6 kb/s. The transmission power of the 915 MHz radio is adjustable from 30 dBm to -20 dBm.