MQ=Medium
WQ= Wide
RW= Rectangular Wide
DL= D rive Lane / Type 4
Options (Add as Sux)
F=Sin gle Fuse (120, 27 7 or 347V Sp ecify Volta ge)
FF=Doub le Fuse (208, 240 or 480V S pecify Vol tage)
IBP=Integral Battery Pack
IBP-CEC=Integral Battery Pack, CEC compliant
ITS=Integral Transfer Switch
924=UL924 listed luminaire
CG=Clear Glass
SG=Solite® Glass
UPL=Uplight
TR=Tamper Resistant Hardware
NAT=Na tatorium n ish
DALI=DALI Driver
MS/DIM-L08=Dimming Occupancy Sensor (<9’ Mou nting)
MS/DIM-L20=Dim ming Occup ancy Sensor (9’ - 20’ Mou nting)
ZW=WaveLinx-Enabled Module and 4-PIN Receptacle 23
ZD=WaveL inx-Enab led Module w ith DALI Dri ver and 4-P IN Recept acle
ZW-SWPD4XX=WaveLinx C ontrol Mod ule and Wire less Sensor – 7 ’-15’ 21
ZW-SWPD5XX=WaveLinx Control Module an d Wireless S ensor – 15’-4 0’ 21
ZW-WOBX X=WaveLinx Co ntrol Modu le and LC Bluetooth Sens or – 7’-15’ 21
ZW-WOF XX=WaveLinx C ontrol Mod ule and LC Bluetooth Se nsor – 15’-40 ’ 21
ZD-SWPD4XX=WaveLinx with DALI D river and Wireless Se nsor – 7’-15’ 21
ZD-SWPD5XX=WaveLi nx with DALI D river and Wi reless Sensor – 15’-40 ’ 21
ZD-WOBX X=WaveLinx wi th DALI Dri ver and LC Blue tooth Sensor – 7’-15’ 21
ZD-WOF XX=WaveLin x with DALI Dr iver and LC Blu etooth Sen sor – 15’-40 ’ 21
LWR-LW=Enlighte d Wireless Sensor, Wide Lens 8’ - 16’ Moun ting Heigh t
LWR-LN=Enlighted Wireless Sensor, N arrow Lens 16’ - 40 ’ Mounting Height
DIM10-MS/DIM-L08=Synapse occupancy sensor (<8’ Mounting)
DIM10-MS/DIM-L20=Synapse occupancy sensor (8’-20’ Mounting)
NOTES:
1. DesignLights Consortium® Quali ed. Refer to w ww.designl ights.org Q ualied Pr oducts Lis t under Famil y Models for de tails.
2. Only for use w ith 480V Wy e systems. Pe r NEC, not for us e with ungro unded syste ms, impeda nce ground ed systems or c orner
3. D1-D4 l umen packa ges only.
4. Orde r Pendant Mo unt Stem acc essory
5. IBP am bient oper ating tempe rature -20° C to 35°C (D1-D 3), -20°C to 25°C ( D4-D6). N ot available w ith DALI.
6. Addit ional 8.0W. Pro vides 920 lum ens.
7. Choose lea d length for S urface Mou nt and Stem M ount only. TM B, DPM and WM le ngths pred etermine d.
8. Not avai lable with C Q.
9. Stand ard with CQ , option avail able with WQ on ly.
10. U voltag e only. Ambie nt operati ng tempera ture -20°C to 5 0°C (D1-D4) o r -20°C to 40°C ( D5-D6). U L924 listed c omponent .
11. Includes integral photocell.
12. Spec ify color in p lace of XX.
13. Design ed for use with S tem Mount a nd Decorat ive Pendant M ount only.
6
groun ded systems (c ommonly kn own as Three Ph ase Three Wi re Delta, Th ree Phase Hig h Leg Delta an d Three Phas e Corner
Groun ded Delta sys tems).
5, 24
10
8
19
9
15
5
11, 17
11, 17
23
11, 18
11, 18
MA12 52=Replacement 10kV Surge Module
TT/ WG=Wire Guard
TT/BG-UP-XX=Bird Guard
TT/HSS-XX=House S ide Shield
DPM S36-XX=36” Pendant Mount Stem
DPM S48-XX=48” Pen dant Mount S tem
DPMS96-XX=96” Pendan t Mount Stem
FSIR-100=Wire less Cong uration Tool fo r Occupancy Sensor 17
SWPD4-XX=WaveLinx W ireless Se nsor, 7’–15’ Mounti ng Height
SWP D5-XX=WaveLinx Wireless Se nsor, 15’–40’ Mounting Hei ght
14. Desig ned for use wit h Decorati ve Pendant Mo unt only.
15. Not avail able with H vol tage or IBP. Not com patible wi th MS/DIM or LW R sensors.
16. Speci fy Lead Len gth for wire ha rness lengt h.
17. The FSIR -100 congur ation tool is re quired to ad just parame ters inclu ding high and l ow modes, sen sitivity, t ime delay and
more.
18. Enlig hted wirele ss sensors ar e factory in stalled onl y, and requir e network co mponents i n appropri ate quantit ies.
19. 924 opti on provides l uminaire UL9 24 listing , used in conju nction wit h ITS or IBP- CEC.
20. Requ ires ZW or ZD re ceptacl e.
21. Repla ce XX with sen sor color ( WH, BZ or BK.)
22. Ca nnot be used wi th other con trol option s.
23. For Wav eLinx appl ications, WA C Gateway requ ired to enabl e eld-c ongurab ility: Or der WAC-Po E and WPOE-12 0 (10V to
PoE inj ector) power s upply if nee ded. Not req uired for Wave Linx Lite Co mmercial ( LC) applicat ions.
24. Spe cify 120V or 27 7V.
25. TT/ WG and TT/HS S cannot be ins talled tog ether.
26. D4 -D6 only. Not c ompatible w ith batter y.
[Blank]= Surface Mount
TMB= Trunnion Mount with Connection Box
DPM=Decorative Pendant Mount
WM=Wall Mount
* Supported by IES TM-21 standards
**Theoretical values represent estimations commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES PS-10-18, explaining proper use of IES TM-21 and LM-80
Lumen Multiplier
Ambient TemperatureMultiplier
0°C1.03
10C1.02
25°C1.00
40°C0.98
50°C0.97
PS515001EN page 5
February 19, 2021 2:35 PM
McGraw-Edison
0-10V
Thisfixtureisofferedstandardwith0-10V dimming driver(s). External 0-10V dimming wireleads are providedfor use with a lighting control panel or other control methodsexceptwhenPER7, 5LTD, MS/DIM, LWR,IBP orICP isspecified.
Dimming Occupancy Sensor (MS/DIM-LXX)
These sensors are factory installed in the luminaire housing. WhentheMS/DIM-LXXsensoroptionisselected, the occupancy sensorisconnected to a dimming driverand theentire luminaire dimswhenthereisnoactivitydetected. Whenactivity isdetected, the luminaire returns tofull light output. The MS/DIMsensorisfactory presettodim downtoapproximately 50percent power with a timedelayoffive minutes.
These occupancy sensors include an integralphotocell thatcan beactivated withtheFSIR-100accessory for “dusk-to-dawn” control ordaylightharvesting. The factory presetisOFF.Please refer tothesupplemental guide to understand limitations ofproduct use regarding specific applications.The FSIR-100 is a wirelesstoolutilizedfor changingthedimming level, timedelay, sensitivity and other parameters.
A variety ofsensorlensesare available tooptimizethe coveragepattern for mountingheights from8’-40’.
0-10V
Thisfixtureisofferedstandardwith0-10V dimming driver(s). External 0-10V dimming wireleads are providedfor use with a lighting control panel or other control methodsexceptwhenPER7, 5LTD, MS/DIM, LWR,IBP orICP isspecified.
Dimming Occupancy Sensor (MS/DIM-LXX)
These sensors are factory installed in the luminaire housing. WhentheMS/DIM-LXXsensoroptionisselected, the occupancy sensorisconnected to a dimming driverand theentire luminaire dimswhenthereisnoactivitydetected. Whenactivity isdetected, the luminaire returns tofull light output. The MS/DIMsensorisfactory presettodim downtoapproximately 50percent power with a timedelayoffive minutes.
These occupancy sensors include an integralphotocell thatcan beactivated withtheFSIR-100accessory for “dusk-to-dawn” control ordaylightharvesting. The factory presetisOFF.Please refer tothesupplemental guide to understand limitations ofproduct use regarding specific applications.The FSIR-100 is a wirelesstoolutilizedfor changingthedimming level, timedelay, sensitivity and other parameters.
A variety ofsensorlensesare available tooptimizethe coveragepattern for mountingheights from8’-40’.
0-10V
Thisfixtureisofferedstandardwith0-10V dimming driver(s). External 0-10V dimming wireleads are providedfor use with a lighting control panel or other control methodsexceptwhenPER7, 5LTD, MS/DIM, LWR,IBP orICP isspecified.
Dimming Occupancy Sensor (MS/DIM-LXX)
These sensors are factory installed in the luminaire housing. WhentheMS/DIM-LXXsensoroptionisselected, the occupancy sensorisconnected to a dimming driverand theentire luminaire dimswhenthereisnoactivitydetected. Whenactivity isdetected, the luminaire returns tofull light output. The MS/DIMsensorisfactory presettodim downtoapproximately 50percent power with a timedelayoffive minutes.
These occupancy sensors include an integralphotocell thatcan beactivated withtheFSIR-100accessory for “dusk-to-dawn” control ordaylightharvesting. The factory presetisOFF.Please refer tothesupplemental guide to understand limitations ofproduct use regarding specific applications.The FSIR-100 is a wirelesstoolutilizedfor changingthedimming level, timedelay, sensitivity and other parameters.
A variety ofsensorlensesare available tooptimizethe coveragepattern for mountingheights from8’-40’.
LumaWattPro Wireless Control and Monitoring System (LWR-LW and LWR-LN)
The LumaWattPro systemis a peer-to-peerwirelessnetwork of luminaire-integralsensors for any sized project.Eachsensoriscapable ofmotionand photo sensing,metering power consumptionand wirelesscommunication.The end-usercan securelycreateand managesensorprofiles withbrowser-basedmanagementsoftware. The software will automaticallybroadcast tothesensors via wirelessgatewaysfor zone-basedand individual luminaire control.The LumaWattPro softwareprovidessmart buildingsolutions byutilizing the sensortoprovide easy-to-use dashboard and analyticcapabilitiessuchas improved energysavings,trafficflow analysis,buildingmanagementsoftware integration and more.
For additionaldetails,refer totheLumaWattPro product guides.
For mounting heights up to 20' (-L20)
20
15
10
5
0
20181512966391215183020
Coverage Side Area (Feet)
16
0
8
70
Coverage Side Area (Feet)
For mounting heights up to 8' (-L08)
71824551824
TT TopTier
Control Options
0-10V (D) 0-10V dimming comes standard on all TopTier congurations for use with integrated or external lighting controls.
Dimming Occupancy Sensor (MS/DIM) These sensors are factory installed in the luminaire, dimming to 50% after ve minutes of no motion detected. When motion is
detected, the luminaire output is 100%. Includes an integral photocell that can be programmed for “dusk-to-dawn” operation. The FSIR-100 programming tool can be utilized to
adjust dimming level, time delay, sensitivity and other parameters. Two lens options provide optimal coverage patterns up to 20’ mounting height.
For mounting heights up to 8' (-L08)
0
8
24551824
70
718
Coverage Side Area (Feet)
For mounting heights up to 20' (-L20)
0
5
10
15
20
20 18 15 129663912 15 183020
Coverage Side Area (Feet)
WaveLinx-Ready 4-PIN Twistlock Receptacle (ZW) Includes the WaveLinx control module, integrated 4-Pin receptacle, and standard 0-10V dimming driver, enabling the
subsequent addition of a WaveLinx sensor.
Enlighted Wireless Control and Monitoring System (LWR-LW and LWR-LN) The Enlighted control system is a connected lighting solution, combining LED luminaires with
an integrated wireless sensor system. The sensor controls the lighting system in compliance with the latest energy codes while collecting valuable data about building
performance and use. Software applications utilizing energy dashboards maximize data inputs to help optimize the use of other resources beyond lighting.
For mounting heights from 8' to 16' (LWR-LW)
0
For mounting heights from 16' to 40' (LWR-LN)
0
20
30
241880
81824
Coverage Side Area (Feet)
40
01020304010203040
Coverage Side Area (Feet)
Synapse (DIM10) SimplySNAP integrated wireless controls system by Synapse. Includes factory installed DIM10 control module and MS/DC motion sensor; requires
additional Synapse system components for operation. Contact Synapse at www.synapsewireless.com for product support, warranty, and terms and conditions.
For mounting heights up to 8' (-L08)
0
8
24551824
70
718
Coverage Side Area (Feet)
For mounting heights up to 20' (-L20)
0
5
10
15
20
20 18 15 129663912 15 183020
Coverage Side Area (Feet)
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com