Project Catalog # Type
in Ordering Information Section
Prepared by Notes Date
Cruze ST 22CZ2
2' x 2' LED Specication Grade Troffer
Typical Applications
Oce • Education • Healthcare • Hospitality • Retail
Interactive Menu
Product Certication
• Order Information page 2
• Photometric Data page 3
• Connected Systems page 5
Product Features
• VividTuneTM Color Tuning Solutions page 6
• Product Warranty
Top Product Features
• Latch-less design provides clean architectural look
• VividTune CCT tuning options from 3000K-5000K or 2700K-6500K
• Designers delight - ribbed, smooth and round perforated lens options
• High performance ecacy up to 151 lm/W
• Integrated sensor systems - occupancy, daylight and IoT connectivity
Dimensional and Mounting Details
7" [179mm]
3-1/4"
23-3/4"
10-1/2"
15" [381mm]
Shielding
HRP - High-Eciency Round Perf Inlay
See ordering information for more shielding options.
SQR - Square Lens
Ceiling Compatibility
Grid/Lay-in
Standard
Concealed T
Slot Grid
Type Type
Exposed Grid Standard
Concealed TStandard
Slot Grid Standard
Flange *
*See Drywall Frame Kit Accessory
PS519305EN page 1
April 6, 2021 3:06 PM
22CZ2 LED
Order Information
SAMPLE ORDER NUMBER: 22CZ2-34HE-UNV-L835-CD1-U
Rating Series Air Lumen Output Shielding Voltage Options
Rating Series Air Lumen Level Ecacy Shielding Voltage
[Blank]=Standard
ATW-SW4=
Chicago Rated
22CZ2=2x2
Cruze ST
[Blank]=Standard
A=Air (Vented)
(1) Air version is intended for air return
through plenum. See air return data
table for air ow volumes.Air option
not available with ATW-SW4.
(1)
Notes Notes Notes
20=2000 Lumens
24=2400 Lumens
29=2900 Lumens
32=3200 Lumens
34=3400 Lumens
39=3900 Lumens
44=4400 Lumens
50=5000 Lumens
55=5500 Lumens
60=6000 Lumens
65=6500 Lumens
(2) Not available with WN driver. (3) White tuning not available with this model.
(4) Available up to 4400 lumens. (5) Currently only available with CD driver
option. (6) Only available in Standard Ecacy. (7) Not available in Standard
Ecacy.
(2)
70=7000 Lumens
(2)
75=7500 Lumens
(7)
80=8000 Lumens
(6)
85=8500 Lumens
(7)
90=9000 Lumens
95=9500 Lumens
100=10000 Lumens
(5)
110=11000 Lumens
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
[Blank]=Standard
(3), (4)
Ecacy
HE=High
(4)
Ecacy
VHE=Very High
(5)
Ecacy
[Blank]=Ribbed
Frosted Acrylic Lens
(standard)
S=Smooth Frosted
Acrylic Lens
RDP=Smooth Lens
with Round Pattern
Insert
HRP=High-Eciency
Round Perf Inlay
SQR=Square Lens
UNV=Universal Voltage 120-277
347V=347 Volt
48V=48 Volt Low-voltage (Class 2)
(8) Products also available in non-US
voltages and frequencies for international
markets. (C) Consult WaveLinx Low-Voltage
or DLVP system pages for additional details
and compatibility.
Emergency Options CRI/CCT Flex
Emergency Options CRI/CCT Flex
[Blank]=No emergency
EL7W=7-watt 120V-277V emergency battery pack
EL14W=14-watt 120V-277V emergency battery pack
EL10WSD=Bodine 10W emergency battery pack with self diagnostic installed
ELV7W=Low-voltage system, 7-watt emergency battery pack
ELV14W=Low-voltage system, 14-watt emergency battery pack
ETRD=Iota Emergency Transfer Relay with dimming control
RRU=LVS Controls Emergency Transfer Relay with dimming control
UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack
UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack
UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed
UETRD=UL924 Listed luminaire, Iota Emergency Transfer Relay with dimming control
URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control
(9) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the
lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens).
IES-format photometry for luminaire under emergency operation available. Battery option increases total height by
1 inch. (10) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided
by others). Devices are universal voltage (UNV). 347 not available. (11) EL10WSD not available with 347V. (12)
UEL10WSD not available with 347V. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details
and compatibility.
(9)
(9)
(C)
(C)
(10)
(9), (11)
(10)
(9)
(9)
(9), (12)
(10)
Notes Notes
L830=80CRI, 3000K
L835=80CRI, 3500K
L840=80CRI, 4000K
L850=80CRI, 5000K
L930=90CRI, 3000K
L935=90CRI, 3500K
L940=90CRI, 4000K
L950=90CRI, 5000K
L83050=80CRI 3000K-5000K White Tuning
L93050=90CRI 3000K-5000K White Tuning
L82765=80CRI 2700K-6500K White Tuning
L92765=90CRI 2700K-6500K White Tuning
(10)
(13) White tuning provides correlated color
temperatures (CCT) between 3000K (warm) to 5000K
(cool) or 2700K (warm) to 6500K (cool). Must be used
in conjunction with W2A driver only. Must be used
with two (2) 10V dimming control channels, 1 color,
1 intensity. May be combined with Wavelinx sensor
control systems only.
[Blank]=No Flex
A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads
A3/8-2/18G=3/8" Flex with line and common
A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate
wiring. See below for details.
(13)
(13)
(13)
(13)
Flexible Metal Conduit Options
Flex options available for 0-10V dimming control, DALI dimming control, emergency and
night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire
housing access plate with 90° enclosed FMC connector. Not all options may be combined
and installation ratings vary by type. See online configurator for all ex options.
A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” exible metal conduit
with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires.
Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501,
502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly
J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour
through penetration with applicable fire stop product (not included). May be surface
mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated,
install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).
(8)
(C)
Options
GL=Single
Element Fuse
GM=Double
Element Fuse
Driver Type Number of Drivers Integrated Sensing Systems Packaging Accessories
Driver Type Number of Drivers Integrated Sensing Systems
CD=0-10V Dimming Driver (1%-100% Dimming)
WN=WaveLinx Wireless Fixture, No Sensor.
5LTD=Fifth Light DALI Driver (5%-100% Dimming)
5LTHD=Fifth Light Dimming Driver (1%-100% Dimming)
LV=Low-voltage System Dimming Driver (0%-100% Dimming)
SD=Step Dimming Driver (50%-100% Dimming)
LH=Lutron HiLume (LDE1 series) 1%-100% EcoSystem Driver with
Soft-on Fade to Black dimming
L5=Lutron 5 Series (LDE5-Series) 5%-100% EcoSystem Driver
W2A=White Tuning, 2 ch, Analog 0-10V Intensity and CCT Control
SR=Sensor-ready Dimming Driver (1%-100% Dimming)
(14) White tuning provides correlated color temperatures (CCT) between 3000K
(warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in
conjunction with W2A driver only. Must be used with two (2) 10V dimming control
channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control
systems only.
Integrated options must be used in conjunction with the associated system
and may not be compatible with other options or accessories. Please refer to
the following: (A) Consult WaveLinx system pages for additional details and
compatibility. (C) Consult WaveLinx Low-Voltage or DLVP system pages for
additional details and compatibility. (E) Consult Fifth Light system pages for
additional details and compatibility. (F) Consult Marketplace Options - Lutron
system pages for additional details and compatibility. Compatible only with driver
series shown, and may require two or more drivers. Requires field commissioning
to operate or dim. Contact Lutron at www.lutron.com. (G) Not compatible with GTR,
ETRD, or integrated sensor options. (H) Available with UNV voltage only.
(A), (G), (H)
(E)
(E)
(C)
(F)
(F)
(14)
Notes Notes Notes
1=1 Driver [Blank]=No Sensor
WAA=WaveLinx Wireless Integrated Sensor
WAB=WaveLinx Lite Wireless Integrated Sensor
WLA=Low-voltage Integrated Sensor
SVPD1=0-10V Stand-alone Integrated Sensor
(15) Matching width lens band on other side of sensor band may be supplied
for symmetrical appearance. Required for use with sensor and emergency
combination. Add “D” to sensor ordering as shown - WAAD, WABD, SDVPD1. (16)
WAA sensor to be used with CD or W2A driver. (17) WAB and SVPD1 sensor to
be used with CD driver. (18) WLA sensor to be used with LV driver.
Integrated options must be used in conjunction with the associated system
and may not be compatible with other options or accessories. Please refer to
the following: (A) Consult WaveLinx system pages for additional details and
compatibility. (B) WaveLinx Lite devices are not currently compatible with the
WaveLin x Wireless A rea Contro ller. Consult WaveLinx Lite system pages for
additional details and compatibility. (C) Consult WaveLinx Low-Voltage or DLVP
system pages for additional details and compatibility. (D) Consult SVPD series
system pages for additional details and compatibility.
(18), (C)
(16), (A)
(15)
(17), (D)
(17), (B)
Packaging Accessories (order separately)
U=Unit Pack
PAL =Job
Pack,
out of carton
PAL C=Job
Pack,
in carton
CZ2-EQCLIP-U-PK=“CZ2” Earthquake
Clip Kit (4 clips per bag kit)
DF-22W-U=2' x 2' Drywall Frame Kit
SK-22-WS=2' x 2' Shallow Surface
Mount Kit
SK-22-WT=2' x 2' Tall Surface Mount Kit
ISHH-01=Programming Remote for
Integrated Sensor
ISHH-02=Personal Control Remote for
Integrated Sensor
(19) An EQ Grid Clip is recommended for all 9/16"
ceiling systems. Four required per fixture.
Integrated options must be used in conjunction
with the associated system and may not be
compatible with other options or accessories.
Please refer to the following: (D) For use with SVPD
sensor only. Consult SVPD series system pages for
additional details and compatibility.
PS519305EN page 2
(19)
(D)
(D)
April 6, 2021 3:06 PM