(2) Not available with WN driver. (3) White tuning not available with this model.
(4) Available up to 4400 lumens. (5) Currently only available with CD driver
option. (6) Only available in Standard Ecacy. (7) Not available in Standard
Ecacy.
(2)
70=7000 Lumens
(2)
75=7500 Lumens
(7)
80=8000 Lumens
(6)
85=8500 Lumens
(7)
90=9000 Lumens
95=9500 Lumens
100=10000 Lumens
(5)
110=11000 Lumens
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
(5)
[Blank]=Standard
(3), (4)
Ecacy
HE=High
(4)
Ecacy
VHE=Very High
(5)
Ecacy
[Blank]=Ribbed
Frosted Acrylic Lens
(standard)
S=Smooth Frosted
Acrylic Lens
RDP=Smooth Lens
with Round Pattern
Insert
HRP=High-Eciency
Round Perf Inlay
SQR=Square Lens
UNV=Universal Voltage 120-277
347V=347 Volt
48V=48 Volt Low-voltage (Class 2)
(8) Products also available in non-US
voltages and frequencies for international
markets. (C) Consult WaveLinx Low-Voltage
or DLVP system pages for additional details
and compatibility.
Emergency OptionsCRI/CCTFlex
Emergency OptionsCRI/CCTFlex
[Blank]=No emergency
EL7W=7-watt 120V-277V emergency battery pack
EL14W=14-watt 120V-277V emergency battery pack
EL10WSD=Bodine 10W emergency battery pack with self diagnostic installed
ELV7W=Low-voltage system, 7-watt emergency battery pack
ELV14W=Low-voltage system, 14-watt emergency battery pack
ETRD=Iota Emergency Transfer Relay with dimming control
RRU=LVS Controls Emergency Transfer Relay with dimming control
UEL7W=UL924 Listed luminaire, 7-watt, 120V-277V emergency battery pack
UEL14W=UL924 Listed luminaire, 14-watt 120V-277V emergency battery pack
UEL10WSD=Bodine 10W emergency battery pack with self diagnostic installed
UETRD=UL924 Listed luminaire, Iota Emergency Transfer Relay with dimming control
URRU=UL924 Listed luminaire, LVS Controls Emergency Transfer Relay with dimming control
(9) Factory installed with integral test switch/indicator/laser test. For approximate delivered lumens multiply the
lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens).
IES-format photometry for luminaire under emergency operation available. Battery option increases total height by
1 inch. (10) Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided
by others). Devices are universal voltage (UNV). 347 not available. (11) EL10WSD not available with 347V. (12)
UEL10WSD not available with 347V. (C) Consult WaveLinx Low-Voltage or DLVP system pages for additional details
and compatibility.
(9)
(9)
(C)
(C)
(10)
(9), (11)
(10)
(9)
(9)
(9), (12)
(10)
NotesNotes
L830=80CRI, 3000K
L835=80CRI, 3500K
L840=80CRI, 4000K
L850=80CRI, 5000K
L930=90CRI, 3000K
L935=90CRI, 3500K
L940=90CRI, 4000K
L950=90CRI, 5000K
L83050=80CRI 3000K-5000K White Tuning
L93050=90CRI 3000K-5000K White Tuning
L82765=80CRI 2700K-6500K White Tuning
L92765=90CRI 2700K-6500K White Tuning
(10)
(13) White tuning provides correlated color
temperatures (CCT) between 3000K (warm) to 5000K
(cool) or 2700K (warm) to 6500K (cool). Must be used
in conjunction with W2A driver only. Must be used
with two (2) 10V dimming control channels, 1 color,
1 intensity. May be combined with Wavelinx sensor
control systems only.
[Blank]=No Flex
A3/8-4/18GDIM=3/8" Flex with 0-10V Dimming Leads
A3/8-2/18G=3/8" Flex with line and common
A3/8-5/18GDIM=Flex with 0-10V Dimming leads and Blue for alternate
wiring. See below for details.
(13)
(13)
(13)
(13)
Flexible Metal Conduit Options
Flex options available for 0-10V dimming control, DALI dimming control, emergency and
night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire
housing access plate with 90° enclosed FMC connector. Not all options may be combined
and installation ratings vary by type. See online configurator for all ex options.
A3/8-4/18GDIM series notes: Factory installed dimming option 3/8” exible metal conduit
with 2-#18 power and ground wires and 2-#18 UL-listed jacketed 0-10V +/- control wires.
Meets UL 66, 83, 1479, 1569, 1581, 2556. NEC® 250.118, 300.22(C), 392, 396, 330, 501,
502, 503, 530, 504, 505, 518, 520, 530, 645, 72; Federal Specification A-A-59544 (formerly
J-C-30B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour
through penetration with applicable fire stop product (not included). May be surface
mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated,
install per NEC®; Environmental Air-Handling Space Installation per NEC® 300.22(C).
(8)
(C)
Options
GL=Single
Element Fuse
GM=Double
Element Fuse
Driver TypeNumber of DriversIntegrated Sensing SystemsPackagingAccessories
Driver TypeNumber of DriversIntegrated Sensing Systems
L5=Lutron 5 Series (LDE5-Series) 5%-100% EcoSystem Driver
W2A=White Tuning, 2 ch, Analog 0-10V Intensity and CCT Control
SR=Sensor-ready Dimming Driver (1%-100% Dimming)
(14) White tuning provides correlated color temperatures (CCT) between 3000K
(warm) to 5000K (cool) or 2700K (warm) to 6500K (cool). Must be used in
conjunction with W2A driver only. Must be used with two (2) 10V dimming control
channels, 1 color, 1 intensity. May be combined with Wavelinx sensor control
systems only.
Integrated options must be used in conjunction with the associated system
and may not be compatible with other options or accessories. Please refer to
the following: (A) Consult WaveLinx system pages for additional details and
compatibility. (C) Consult WaveLinx Low-Voltage or DLVP system pages for
additional details and compatibility. (E) Consult Fifth Light system pages for
additional details and compatibility. (F) Consult Marketplace Options - Lutron
system pages for additional details and compatibility. Compatible only with driver
series shown, and may require two or more drivers. Requires field commissioning
to operate or dim. Contact Lutron at www.lutron.com. (G) Not compatible with GTR,
ETRD, or integrated sensor options. (H) Available with UNV voltage only.
(15) Matching width lens band on other side of sensor band may be supplied
for symmetrical appearance. Required for use with sensor and emergency
combination. Add “D” to sensor ordering as shown - WAAD, WABD, SDVPD1. (16)
WAA sensor to be used with CD or W2A driver. (17) WAB and SVPD1 sensor to
be used with CD driver. (18) WLA sensor to be used with LV driver.
Integrated options must be used in conjunction with the associated system
and may not be compatible with other options or accessories. Please refer to
the following: (A) Consult WaveLinx system pages for additional details and
compatibility. (B) WaveLinx Lite devices are not currently compatible with the
WaveLin x Wireless A rea Contro ller. Consult WaveLinx Lite system pages for
additional details and compatibility. (C) Consult WaveLinx Low-Voltage or DLVP
system pages for additional details and compatibility. (D) Consult SVPD series
system pages for additional details and compatibility.
(18), (C)
(16), (A)
(15)
(17), (D)
(17), (B)
PackagingAccessories (order separately)
U=Unit Pack
PAL =Job
Pack,
out of carton
PAL C=Job
Pack,
in carton
CZ2-EQCLIP-U-PK=“CZ2” Earthquake
Clip Kit (4 clips per bag kit)
DF-22W-U=2' x 2' Drywall Frame Kit
SK-22-WS=2' x 2' Shallow Surface
Mount Kit
SK-22-WT=2' x 2' Tall Surface Mount Kit
ISHH-01=Programming Remote for
Integrated Sensor
ISHH-02=Personal Control Remote for
Integrated Sensor
(19) An EQ Grid Clip is recommended for all 9/16"
ceiling systems. Four required per fixture.
Integrated options must be used in conjunction
with the associated system and may not be
compatible with other options or accessories.
Please refer to the following: (D) For use with SVPD
sensor only. Consult SVPD series system pages for
additional details and compatibility.
PS519305EN page 2
(19)
(D)
(D)
April 6, 2021 3:06 PM
0˚30˚
˚
˚
˚
˚
20˚
˚
˚
10˚
0˚30˚
˚
˚
˚
˚
20˚
˚
˚
10˚
Product Specications
Construction
• Die formed of code gauge prime cold rolled steel
with full length die-formed stiffeners
• Unibody endplates attached with interlocking tabs
and screws
• Hemmed side anges
• Four auxiliary xture end suspension points
• Integral Grid-lock feature for endplates for added
safety
• Optional earthquake clips available
Integrated Controls
• 0-10V dimming to 1% standard
• WaveLinx wireless xture for sensor-less wireless
control
• WaveLinx wireless sensor compatible for
standalone, controlled, connected, and IoT capability
• SVPD sensor compatible for standalone
functionality
• Low-voltage sensor and driver compatible for
WaveLinx Low-Voltage and DLVP applications
• DALI 2.0, Lutron, and step-dimming available
LED and Light Engine
• LED’s available in 3000K, 3500K, 4000K, or 5000K at
80 CRI minimum and 90 CRI minimum
• Color accuracy ≤3-Step MacAdam ellipse (SDCM)
• TM21 life at 60,000 hours up to L90 and calculated
L70 exceeds 203,000 hrs.
• Drivers available in 120-277V and 347V
• Tunable white options available with Cooper
Lighting Solutions’ Vividtune
Emergency Battery Options
• Optional emergency battery available in 7W and 14W
• 90-minute backup period for code compliance
• Laser point test from oor for ease of use on 7W
and 14W versions
• EZ Key feature prevents accidental discharge during
construction on 7W and 14W versions
• Integral emergency transfer relay options available
Finish
• Multistage, iron phosphate pretreatment
• 90% reective, matte white enamel nish
• Full xture housing painted after fabrication
22CZ2 LED
Shielding
• Ribbed acrylic frosted lens standard
• Optional smooth acrylic frosted lens (S)
• Optional metal perforated acrylic lens (RDP)
• Optional High-Eciency Round Perf Inlay (HRP)
Compliance
• IC rated for insulation contact
• cULus listed for damp locations
• RoHS compliant
• Tested to IESNA LM-79 and LM-80
• Stated life tested to TM21 standards
• Can be used for State of California Title 24 high
ecacy luminaire
Warranty
• Five-year warranty standard. Optional ten year
warranty available.
Photometric Data
90
299
598
896
1195
80
70
60
50
40
22CZ2-24-UNV-L830-CD1-U
Dimming Driver
Linear LED 3000K
Spacing criterion: (II) 1.2 x mounting height, (⊥)
Spacing criterion: (II) 1.19 x mounting height, (⊥)
1.27 x mounting height
60
Lumens: 2402
50
Input Watts: 19.2W
Ecacy: 125.1 LPW
40
Test Report: 14CZ2-29-UNV-L830-CD1-U.IES
PS519305EN page 3
April 6, 2021 3:06 PM
Energy and Performance Data
Standard Ecacy Versions – Single Row of LEDs
Catalog NumberLumensWattslm/W
22CZ2-20-UNV-L835-CD1-U214216.2132
22CZ2-24-UNV-L835-CD1-U245418.5133
22CZ2-32-UNV-L835-CD1-U327224.2135
22CZ2-39-UNV-L835-CD1-U395331128
22CZ2-44-UNV-L835-CD1-U446233134
High Ecacy Versions – Two Rows of LEDs
Catalog NumberLumensWattslm/W
22CZ2-20HE-UNV-L835-CD1-U203015.0135
22CZ2-24HE-UNV-L835-CD1-U247418.1137
22CZ2-29HE-UNV-L835-CD1-U298220.9143
22CZ2-34HE-UNV-L835-CD1-U342624.3141
22CZ2-39HE-UNV-L835-CD1-U399728.5140
22CZ2-44HE-UNV-L835-CD1-U456732.8139
Very High Ecacy Versions – Three Rows of LEDs
Catalog NumberLumensWattslm/W
22CZ2-20VHE-UNV-L835-CD1-U20 0814.2141
22CZ2-24VHE-UNV-L835-CD1-U25011 7. 5143
22CZ2-29VHE-UNV-L835-CD1-U3 11 421.7144
22CZ2-34VHE-UNV-L835-CD1-U359825.1143
22CZ2-39VHE-UNV-L835-CD1-U407828.6143
22CZ2-44VHE-UNV-L835-CD1-U462032.6142
22CZ2-50VHE-UNV-L835-CD1-U509536.2141
22CZ2-55VHE-UNV-L835-CD1-U553039.4140
22CZ2-60VHE-UNV-L835-CD1-U6 11 044.1139
22CZ2-65VHE-UNV-L835-CD1-U655947.9137
22CZ2-70VHE-UNV-L835-CD1-U701750.314 0
22CZ2-75VHE-UNV-L835-CD1-U755754.7138
22CZ2-80VHE-UNV-L835-CD1-U809259.1137
22CZ2-85VHE-UNV-L835-CD1-U861563.6136
22CZ2-90VHE-UNV-L835-CD1-U912568.2134
22CZ2-95VHE-UNV-L835-CD1-U961072.7132
22CZ2-100VHE-UNV-L835-CD1-U1010877.7130
22CZ2-110VHE-UNV-L835-CD1-U1106587.7126
22CZ2 LED
Shielding
Lumen Adjustment Factors
SRDPHRPSQR
1.050.670.800.96
Lumen Calculator
CCT
Multiplier
80 CRI90 CRI
3000K0.965 0.827
3500K1.000 0.847
4000K1.019 0.856
5000K1.019 0.909
Notes: (1) Input wattages for 90 CRI versions may vary. Refer to published IES-format
photometry or LM-79 reports for more details.
Example of Lumen Adjustment Calculation
22CZ2-32-UNV-L935-CD1-U at 90CRI at 3500K
Lumen Adjustment Factor = 0.845
Total Light Output =
3,280 lm x 0.845 = 2,772 lm
Ecacy = = 103.8 lm/W
2,772 lm
26.7W
Lumen Maintenance
TM-21 Lumen
Version
Maintenance
(60,000 hours)
(2)
Standard> 85%> 151,000
High Eciency> 90%> 203,000
Very High Eciency> 90%> 203,000
Notes: (2) Supported by IES TM-21 standards. (3) Theoretical values represent estimations
commonly used; however, refer to the IES position on LED Product Lifetime Prediction, IES
PS-10-18, that explains proper use of IES TM-21 and LM-80.
Load Data (Stock Product)
Thd
Power Factor
Weight (lbs.)
Low Temp. Start
6%
0.99
10.6
-20ºC
Shipping Data
Pallet
Catalog No.Wt.
49"L x 52"W x 55"H
2' x 2'12.5 lbs.48
(1)
Theoretical L70
(Hours)
(3)
Air Return Volume
Negative Static
Pressure (Inches H
0.0579
0.1112
0.2161
0.25177
0.3198
0.45239
O)
2
Return Air
Volume (CFM)
PS519305EN page 4
April 6, 2021 3:06 PM
C
L
4.5m (15FT)
4.5m (15FT)
0m(0ft)
C
L
TOP VIEW:
Note: The "beam" patternobtained depends stronglyon the detector used withthis array. The patternshown is intended solelyas a general guide and is not to scale.
Control Systems
• WaveLinx Wireless
• WaveLinx Wired
• WaveLinx Lite
• DLVP
• VividTune
TOP VIEW:
4.5m
(15FT)
0m
(0ft)
4.5m
(15FT)
22CZ2 LED
The Cruze ST with Integrated Sensor technology provides automatic energy savings
without sacrificing performance. The Cruze ST delivers superior lighting with integrated
occupancy and daylighting controls.
For standalone and controlled applications, the WaveLinx Lite integral sensor provides
out-of-the-box functionality with no gateways required and factory startup is not needed.
When more connectivity is required, the WaveLinx Wireless sensor meets modern code
and utility requirements, delivers energy and cost savings, while enabling buildings to
become smart buildings.
The WaveLinx Wireless Connected Lighting System combined
with Trellix provides an open IoT platform and infrastructure
that connects intelligent sensors leveraging the real-estate of
the physical light fixture to solve higher complexity problems to
deliver actionable insights through the aggregation of valuable
4.5m
(15ft)
data.
C
L
SIDE VIEW:
0m
(0ft)
2.4m
C
L
(8ft)
3.0m
(10ft)
4.5m
(15FT)
4.5m
(15FT)
2.25m
(7.5FT)
0m
(0ft)
2.25m
(7.5ft)
Note: Installation of integrated sensors within 3-ft (1m) of HVAC air vents
is not recommended. The pattern shown is intended solely as a general
guide and is not to scale.
Systems comparison chart
Cooper Lighting Solutions provides many lighting system solutions designed
to satisfy code requirements and meet the unique needs of any project.
Standalone Controlled Connected Enterprise
WaveLinx Lite WaveLinx Wireless Trellix
Occupancy Yes Yes Yes Yes
Daylighting Yes Yes Yes Yes
Gateways – – 1 WAC 300 WACs
Devices – 50 per Area (1400 per site) 150 per WAC 45,000 per Core Enterprise
Software – WaveLinx Lite Mobile App WaveLinx Mobile App Trellix Core
Areas – 28 per Site 16 per WAC up to 4,800
Zones – 16 per Area 16 per Area up to 76,800
Scheduling – – Local Global
VividTune™ – – Yes Yes
Plug-Load Control – – Yes Yes
Low-Voltage Power – – Yes Yes
Integration – – – BACnet, API
Dashboards – – – Energy, Occupancy
Configuration – Installer Technician Technician / IT
SCALABILITY
devicesareasfloorsbuildings
PS519305EN page 5
April 6, 2021 3:06 PM
22 Cruze ST LED with VividTune Tunable White
VividTune tunable white luminaires from Cooper Lighting Solutions deliver highquality light in a broad range of continuously variable color temperatures and
intensities. Create a dynamic environment by adjusting the ambient light warmer or
cooler to influence mood, support the task at hand, or create a dramatic ambience.
The ability to control correlated color temperature and intensity separately
using simple controls is the next evolution of LED lighting for the commercial,
educational, healthcare and hospitality space. The unparalleled flexibility and
number of available lighting environments enable users to find the right light with
tunable white.
Performance Data*
22CZ2 LED
Tunable White - Lumen Adjustment Factors
CCT
2700K--0.8680.741
3000K0.8940.7360.8930.771
3500K0.9460.8040.9240.809
4000K0.9930.8680.9440.835
4500K1.0020.8830.9610.857
5000K1.0020.8830.9740.874
6500K--0.9880.897
3000K-5000K2700K-6500K
80 CRI90 CRI80 CRI90 CRI
CCT
Setting
3000K-30262491
3500K338632022722
4000K-33622940
4500K-33942991
5000K-33942991
2' x 2' Cruze ST LED - Example of Approximate Lumen Calculation
VividTune luminaires make tunable white more accessible by using simple and
familiar controls. From wall dimmers to wireless controls, VividTune tunable white
luminaires are compatible with industry standard 0-10V dimming controls. A single
0-10V dimming input is used to control intensity (brightness) while a second 0-10V
dimming input is used to adjust CCT. For suggested control configurations,
go to www.cooperlighting.com for tunable white application guides.
warm 2700Kcool 6500K
warm 3000Kcool 5000K
10%100 %
Intensity
0-10V
CCT
0-10V
CCT
0-10V
Example of Lumen
Adjustment Calculation
22CZ2-34HE-UNV-L83050-W2A1-U
at 80 CRI tuned to 3500K
Adjusted Lumen =
published lm x adjusted lm factor
Adjusted Lumen = 3386 x 0.946
Adjusted Lumen = 3202 lm
* Lumen adjustment factors are for reference
and may be different for each product selected.
Refer to IES files for actual performance data on each.
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com