Cooper Lighting Solutions PP-MT Installation Manual

ADE141890
INS #
Installation Instructions – Pendant Pipe Mount Layout - PP-MT Instructions d’installation – Disposition du montage du luminaire suspendu sur tuyau - PP-MT Instrucciones de instalación: Disposición de montaje del tubo de suspensión PP-MT
Installation Instructions – Pendant Pipe Mount Layout - PP-MT Installation Instructions – Pendant Pipe Mount Layout - PP-MT
WARNING
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION
Before starting any work ensure that all sources of power are turned OFF. . All work must meet local/national electrical
codes and be performed by a certified electrician.
Follow product label information and instructions before installing fixture. Retain installation instructions for future
reference.
Risk of fire, electrical shock, cuts and or other casualty hazards. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Cooper Lighting Solutions assumes no responsibility for claims brought about by improper or careless installation or handling of this product.
Risk of burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
Replace lamp only with correct wattage and type of lamp marked on label. DO NOT exceed the maximum wattage listed
on the fixture label.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
INSTRUCTIONS.
NOTICE
If supply wires are located within 3 inches of driver/ballast, use wire rated for at least 90°C (194°F).
v
Note: Not all option a
and dimension subject to change without notice.
ailable. Please consult your Cooper Lighting Solutions representative for availability. Specification
INSTALLATION
Run Length Fixture Breakdown
A Spacing
Power
4’
B Spacing
8’
C Spacing
12’
B Spacing 96” Spacing
16’
C Spacing
20’
C Spacing
24’
C Spacing
28’
C Spacing
32’
C Spacing
36’
96” Spacing
144” Spacing
96” Spacing 96” Spacing
144” Spacing
144” Spacing 144” Spacing
96” Spacing
Spacing Distance Fixture
A
Spacing Distance Fixture
B
Spacing Distance Fixture
C
46 7/8” Class A Perf/Class A DI
46 7/8” Class A Perf DI/Class A Indirect
45 5/8” Class A Full Perf
46 7/8” Iridium
45 5/8” RZL/Stellar
46 7/8” Minigator/Vertechs/Loft/Element
94 7/8” Class A Perf/Class A DI
94 7/8” Class A Perf DI/Class A Indirect
93 5/8” Class A Full Perf
94 7/8” Iridium
93 5/8” RZL/Stellar
94 7/8” Minigator/Vertechs/Loft/Element
142 7/8” Class A Perf/Class A DI
142 7/8” Class A Perf DI/Class A Indirect
141 5/8” Class A Full Perf
142 7/8” Iridium
141 5/8” RZL/Stellar
142 7/8” Minigator/Vertechs/Loft/Element
Figure 1.
Quantity of Fixture Length Per Continuous Runs
Continuous runs are made up using 8’ and 12’ fixture lengths as shown in the following table:
Fixture Length
4’ 1
8’ 1 2 1 2 1 2 1 2 1
12’ 1 1 2 1 2 3 2 3 4 3 4
Fixture Length
4’
8’ 2 1 2 1 2 1 2 1
12’ 5 4 5 6 5 6 7 6 7 8 7 8 9
4’ 8’ 12’ 16’ 20’ 24’ 28’ 32’ 36’ 40’ 44’ 48’ 52’ 56’
60’ 64’ 68’ 72’ 76’ 80’ 84’ 88’ 92’ 96’ 100’ 104’ 108’
Installation Instructions – Pendant Pipe Mount Layout - PP-MT
ADE141890 www.cooperlighting.com
Installation Instructions – Pendant Pipe Mount Layout - PP-MT
ADE141890 www.cooperlighting.com