Project Catalog # Type
Prepared by Notes Date
Greengate
0-10V Dual Tech Sensor Dimmer
3-in-1 Solution that combines functionality
of a switchpack, a sensor and a 0-10V
dimmer into one wallbox device
OSW-D-010 / VSW-D-010
Typical Applications
Private Oces • Restrooms • Closets • Copy Rooms • Small enclosed spaces
Product Certication
Interactive Menu
• Order Information page 2
• Additional Resources page3
• Wiring Diagrams page 3
• Product Warranty
Part 15
Class A
Product Features
• Meets ASHRAE Standard 90.1 requirements
• Meets CEC Title 24 requirements
California
California
Title 20
Title 20
Compliant
Compliant
Top Product Features
• Compatible with dimmable 0-10V LED and FLR ballasts
• Dual Technology Passive Infrared and Ultrasonic sensor technology
• Fully adjustable Auto ON/Manual ON light level settings
• Provides 180 degree eld of view with 900 sq. ft. of major and 324 sq. ft. of minor motion coverage
• Selectable time delay of 15 seconds (Test mode), 5 minutes, 10 minutes, 15 minutes, 20 minutes (factory default),
30 minutes
Dimensional and Mounting Details Scale or Mounting Height
(44mm)
4.195”
(106.5mm)
58” / 1470mm
48” / 1210mm
additional
product diagrams
PS503244EN page 1
June 2020

Order Information
SAMPLE ORDER NUMBER: OSW-D-010-W
One single gang wallplate included
Catalog Number
Catalog Number Description
OSW-D-010-* (*-W, V, LA, G, B, R)
VSW-D-010-* (*-W, V, LA, G, B, R)
Note
Not all colors are available in stock and some color options may have extended lead times.
0-10V Dual Tech Sensor Dimmer -
Occupancy with LED Single pole/3-Way preset
0-10V Dual Tech Sensor Dimmer -
Vacancy with LED Single pole/3-Way preset
Compatible
Lamp Types
0-10VDC
LED/FLR
0-10VDC
LED/FLR
Product Specications
Key Features
• Compatible with dimmable 0-10V LED and FLR ballasts
• Fully adjustable Auto ON/Manual ON light level settings
• Adjustable high-end and low-end trim setting
• Push pad design provides minimal travel and crisp actuation
• Digital circuitry provides aesthetically pleasing soft ON/fade OFF
• No leakage to load in OFF mode
• Integrated photocell for daylighting
• Zero crossing for long relay life
Technology
• 0-10V Dual Tech Sensor Dimmer
• Dual Technology Passive Infrared and Ultrasonic sensor technology
Mechanical
Mounting Plate/Strap Dimensions: 4.19” H x 1.73” W (106.55mm x 44mm)
Product Housing Dimensions: 2.7” H x 1.73” W x 2.19”D
(68.5mm x 43.9mm x 55.62mm)
Environment:
• Operating temperature: 32°F to 104°F (0°C to 40°C)
• Relative humidity operating: 20% to 90% non-condensing
• For indoor use only
Housing: Durable, polycarbonate decorator housing with gloss nish
Mounting: Fits in a standard 3.5” deep back box
Electrical
• Neutral is required for installation of device
Wiring type:
• Single pole and 3-way
• 8” pre-stripped wire leads,
• #16 AWG for Load and GND wires
• #18 AWG for all other wires
Electrical ratings: 8A 120/277VAC @ 60Hz (LED)
Light Intensity Control: Full-range, continuously variable dimming
Class 2 dimming output section: 0-10 VDC, 80mA maximum current sink.
0-10V output supports up to 40 ballasts/ drivers that draw the standard 2mA each
Surge Protection: Meets ANSI/IEEE Std. C62.41, tested to withstand voltage
surges up to 6000V and current surges of up to 3000A
Radio Frequency Interference: Designed to reduce interference with radio,
audio and video equipment 0-10VDC FLR and LED ballasts
Voltage Ratings: Permanently marked on device label
Flammability: Meets UL 94 requirements; V2 rated
0-10V Dual Tech Sensor Dimmer
Ratings
Watt
960
2200
960
2200
Hardware Specifications
Status Indicators: LED Indicators to indicate motion
LED indicators
• Red LED = PIR detection
• Green LED = Ultrasonic detection
Controls and Performance
Selectable Time delays:
• 15 seconds (Test mode)
• 5 minutes, 10 minutes, 15 minutes, 20 minutes (factory default), 30 minutes
Coverage:
• Provides 180 degree eld of view with 900 sq. ft. of major and 324 sq. ft. of
minor motion coverage
Occupancy Sensor:
• Occupancy Sensor version allows operations to toggle between
Auto ON/Auto OFF or Manual ON/Auto OFF mode
• Occupancy Sensor version provides a selectable ambient light override
preventing lights from switching ON when there is acceptable natural light
Dimming control:
• Full-range preset dimming control provided with horizontal dim/bright bar
Standards/Ratings
• cULus Listed to UL1472, le no. E325082
• FCC Part 15 Class A
• Meets ASHRAE Standard 90.1 requirements
• Meets CEC Title 24 requirements
• California Title 20 Compliant
Warranty
Five year warranty standard
Ratings
V/AC
120
277
120
277
Color
W=White, V=Ivory, LV=Light Almond, G=Gray, B=Black, R=Red
W=White, V=Ivory, LV=Light Almond, G=Gray, B=Black, R=Red
PS503244EN page 2
June 2020

0-10V Dual Tech Sensor Dimmer
Overview
Cooper Lighting Solutions’ 0-10V Dual Tech Sensor Dimmer is a 3 in 1 solution that combines functionality of a switchpack, a sensor and a 0-10V dimmer into one wallbox
device to help customers save labor costs as well as meet the latest energy codes and standards. Eaton’s 0-10V Dual Tech Sensor Dimmer solution offers a convenient and
cost effective way for users to satisfy commercial energy codes like ASHRAE 90.1 and California Title 20 that require designs that enable energy savings for Commercial
facilities. Some of the requirements that can be met by a solution incorporating this device include Area Control, Automatic Lighting Shutoff, Manual ON or Partial ON
(ASHRAE 90.1 only), Multi-level Lighting Control and Occupancy Sensor Control. This product can be used in Single-pole (one location) as well as 3-Way (multi-location)
applications and is aesthetically compatible with Eaton’s decorator style devices and wallplates. This device also allows isolation of its relay for occupancy based control of
external power packs. There is an adjustable Auto ON/Manual ON light level setting, so the lights will only initially turn ON to a user dened setting.
Daylight Switching Operation
In Open-Loop Daylight Switching the daylight sensor measures the natural light contribution in order to automatically adjust lighting. The sensor switches the light off if
enough ambient light is present and it switches the light on if there is not enough ambient light in the space.
Open-Loop Daylight Dimming Operation
In Open-Loop Daylight Dimming the daylight sensor measures the natural light contribution in order to automatically adjust lighting.
Wiring Diagrams
Single-Pole Wiring Diagram FLR, LED
120-277VAC
50/60Hz
Controls
Neutral (White)
Wall Switch for
3-way switching
Earth Ground (Green)
Earth
Hot (Black)
Neutral (White)Hot (Black)
3-Way Input (Blue) Dry Contact Input (Orange)
Daylight
Sensor
LED
indicator
Dim Positive (Purple)
Dim Negative (Gray)
Dry Contact Output (Red)
Hot (Black)
120-277VAC
50/60Hz
use same branch
Neutral (White)
Lighting Load
Wiring Diagram 1:
Typical Wiring Diagram
(Simple 3-way Switch)
Scene Dimming Allowed
Lower
On/Off
Toggle
Raise
PS503244EN page 3
June 2020

Field of View
0-10V Dual Tech Sensor Dimmer
18’
Minor Motion, IR
15’
Major Motion, IR
9’
Maximum coverage area may
vary somewhat according to
room shape and the
presence of obstacles
Control Systems
• Greengate
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.CooperLS.com
© 2019 Cooper Lighting Solutions
All Rights Reserved.
Specifications and dimensions
subject to change without notice.
PS503244EN page 4