3500K/80CRI/DIP/No Lens.
Please refer to scaling data for other
variables. For custom lumen output,
please refer to additional information
on page 3. 1560 Lms/ft not valid with DALI
or Lutron Drivers.
Additional lead-time and cost may
apply for 927, 930, 935 and 940
congurations. 2765/3050 VividTune
congurations require V light engine
and W2A driver.
Icon Key: øConsult factory for availability
(Ft)
Luminaire Length
(Ft)
-___F0=Nominal Length (blank)=12ft (std)
NotesNotesNotes
Minimum xture length is
2ft. Specify to nearest foot
in length.
Max section lengthCircuiting
Max section lengthCircuiting
/8=8ft
Individual xtures congured as
12ft max by default. Continuous
runs congured as 8ft max (12ft
not available).
-1=Single Circuit
-S=Secondary Circuit
Secondary circuit
similar to A/B switching. Price
adder applies for “S” conguration.
E=Emergency Circuit
B1=Surelite 7W 120-277V EM battery pack (EL7W)
B2=Surelite14W 120-277V EM battery pack (EL14W)
T=UL924 EPC Emergency Bypass Relay
NotesNotesNotesNotesNotes
Battery available on xture ≥ 4ft in length. B1-B2 and T options not
compatible with 347V. Standard battery 4ft battery section located
in the beginning of the xture, but can be relocated using the linear
product congurator. Battery test switch located in a knockout on
the top of the xture.
FinishIntegrated Sensor
Finish
-W=White
-S=Silver
-B=Black
-C=Custom Match
-R=RAL Custom
-WAA=WaveLinx Pro Wireless
-WAB=WaveLinx Lite Wireless ø
-LWIPD1=Enlighted Wireless
-SVPD1=Standalone
(Blank)=None
Integrated Sensor
NotesNotes
Contact factory for C
and R options. W/S/B
are standard.
DD driver must be selected. Please refer to page 5 for additional detail
required to specify integrated sensors. Integral option not available with
regressed or drop lensing.
DD driver is standard. For non-dimming applications, the driver will
default to full brightness if no connection is made to the capped
dimming wires in the eld.
Shielding Up
(blank)=No Lens or N/A
-1=Satin White Diffuser
-2=Satin Raised Diffuser
No lens up standard, use satin white
diffuser when dust cover desired of
top of the xture is viewable during
normal use.
Options
-R=GLR Fuse (Fast)
-F=GMF Fuse (Slow)
Additional lead-time may apply. Not
available with 347V option.
TD524028EN page 2
March 15, 2021 10:47 AM
Product Specications
Construction
• Precision cut housing extruded from 6063 aluminum
• Precision cut & welded end-caps ensure a robust and
clean construction
• Nominal 2′ -12′ illuminated sections used in individual
xtures and 2′-8′ illuminated sections used in
continuous runs
Example 2 - Custom Lumen Output based on Required Lumens Per FootExample 2 - Custom Lumen Output based on Required Lumens Per Foot
Total light output (4ft) requirement of 2800 lms, desired CCT and CRI of 4000K/80CRITotal light output (4ft) requirement of 2800 lms, desired CCT and CRI of 4000K/80CRI
Total required lumens per foot @ 4000K= 2800 lms / 4 ft = 700 lms/ftTotal required lumens per foot @ 4000K= 2800 lms / 4 ft = 700 lms/ft
Lumen Adjustment Factor = 1.018 (Requirement based on 4000K / 80CRI)Lumen Adjustment Factor = 1.018 (Requirement based on 4000K / 80CRI)
Estimated ecacy = 121 LPW (nd nearest value using table above)Estimated ecacy = 121 LPW (nd nearest value using table above)
Estimated power consumption = 688 lms/ft ÷ 121 lm/W = 5.69 W/ftEstimated power consumption = 688 lms/ft ÷ 121 lm/W = 5.69 W/ft
Custom Lumen Output
Total Light Output Range (lms/ft)
Lumen Adj Factors Indirect Output Range
CCT
80CRI90CRI80CRI90CRI
2700KN/A0.792N/A372-1236
3000K0.9430.815443-1471 383-1271
3500K1.0000.861470-1560 405-1343
4000K1.0100.892475-1576 419-1392
5000K1.0100.892475-1576 419-1392
If your requirement is expressed in power consumption (W/ft) rather than light output, you If your requirement is expressed in power consumption (W/ft) rather than light output, you
can use the power to lumen output curves to convert power consumption to light output can use the power to lumen output curves to convert power consumption to light output
for specication. Ecacy for cufor specication. Ecacy for custom lumen outputs stom lumen outputs can be estimated using lumen output can be estimated using lumen output
curves or with the use of our online custom lumen output tool.curves or with the use of our online custom lumen output tool.
WaveLinx ProYe sIntegral to FixtureMounted in solid coverWAA
WaveLinx LiteYe sIntegral to FixtureMounted in solid coverWAB
EnlightedYesIntegral to FixtureMounted in illuminated lensLWIPD1
Stand-Alone
SVPD1
Standard Sensor with Luminaire ControlStandard Sensor with Luminaire Control
Auxiliary Sensor used for Sensor Coverage Auxiliary Sensor used for Sensor Coverage
(wireless systems only)(wireless systems only)
NoIntegral to FixtureMounted in solid coverSVPD1
4″ LED Wall Indirect
Optional standalone and wireless connected integrated Optional standalone and wireless connected integrated
sensors require use of the DD (0-10V) driver. WaveLinx and sensors require use of the DD (0-10V) driver. WaveLinx and
Enlighted sensors require additional system hardware (not Enlighted sensors require additional system hardware (not
provided) for full functionality. provided) for full functionality.
Standard sensor layout is shown below. Please refer to sensor Standard sensor layout is shown below. Please refer to sensor
coverage pattern diagrams to ensure proper coverage for coverage pattern diagrams to ensure proper coverage for
the application. Standard congurations are available in both the application. Standard congurations are available in both
individual xtures and in continuous runs. Default spacing individual xtures and in continuous runs. Default spacing
is based on the maximum xture length of 12ft and can be is based on the maximum xture length of 12ft and can be
changed to 8ft sensor spacing for additional coverage by changed to 8ft sensor spacing for additional coverage by
selecting the 8ft max xture length option when ordering.selecting the 8ft max xture length option when ordering.
For additional information integrated sensors and connected For additional information integrated sensors and connected
lighting, please visit lighting, please visit Cooper Lighting Solutions’s Connected
Lighting Website
..
INTEGRAL SENSOR
≤8ft Individual
>8ft Individual
Note: When 8ft max section length is used on individual xtures > 8ft, Note: When 8ft max section length is used on individual xtures > 8ft,
sensor placement follows logic for continuous run.sensor placement follows logic for continuous run.
Beginning of
Run (BOR)
Intermediate
Section (INT)
End of Run
(EOR) > 4ft
End of Run
(EOR) ≤ 4ft
TD524028EN page 5
March 15, 2021 10:47 AM
Define 4 Pendant LED with VividTune Tunable White
VividTune tunable white luminaires deliver high-quality light in a broad range
of continuously variable color temperatures and intensities. Create a dynamic
environment by adjusting the ambient light warmer or cooler to influence mood,
support the task at hand, or create a dramatic ambience. The ability to control
correlated color temperature and intensity separately using simple controls is the
next evolution of LED lighting for the commercial, educational, healthcare and
hospitality space. The unparalleled flexibility and number of available lighting
environments enable users to find the right light with tunable white.
VividTune luminaires make tunable white more accessible by using simple and
familiar controls. From wall dimmers to wireless controls, VividTune tunable white
luminaires are compatible with industry standard 0-10V dimming controls. A single
0-10V dimming input is used to control intensity (brightness) while a second 0-10V
dimming input is used to adjust CCT. For suggested control configurations,
go to www.cooperlightingsolutions.com for tunable white application guides.
warm 2700Kcool 6500K
warm 3000Kcool 5000K
10%100 %
Intensity
0-10V
CCT
0-10V
CCT
0-10V
Example of Approximate Lumen Calculation
Example of Lumen
Adjustment Calculation
S124IW-V1340U83050-UW2A-W
at 80 CRI tuned to 3500K
Adjusted Lumen =
published lm x adjusted lm factor
Adjusted Lumen = 5360 x 0.946
Adjusted Lumen = 5071 lm
* Lumen adjustment factors are for reference
and may be different for each product selected.
Refer to IES files for actual performance data on each.
Cooper Lighting Solutions
18001 East Colfax Avenue
Aurora, CO 80011
P: 303-393-1522