STARTER FITTINGSTARTER CABLE
Project Catalog # Type
Prepared by Notes Date
MWS
ST
Starter Fitting
Starter Cable
Typical Applications
Oce • Education • Healthcare • Hospitality • Retail • Industrial
• Manufacturing • Sports Venues
Interactive Menu
Product Certication
• Order Information page 2
• Product Specications page 2
• System View page 2
• Product Warranty
Top Product Features
• UL Listed under Standard 183 for make or break under load
• Meets requirements of Article 604 of the National Electrical Code
• Rated at 20 amperes with full-size ground wire
• Copper conductors with THHN insulation rated at 90°C
• Galvanized steel exterior with integral keying for voltage
Dimensional and Mounting Details
Front
Front
4-3/8"
Top
3/4"
Side
[112mm]
3/4"
[19mm]
Top
Side
4-3/8"
[112mm]
additional
product diagrams
PS519291EN page 1
November 21, 2019 4:00 PM
ST
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions
All
Rights Reserved.
Specifications and dimensions
subject to change without notice.
are fed from the panel to a junction box with conduit and
Order Information
SAMPLE ORDER NUMBER: 27ST12/2G
Voltage
Voltage Component Conductors and Size Cable Length (Feet) Options
12=120V
20=208V
24=240V
27=277V
34=347V
48=480V
Component Conductors and Size Cable Length (Feet) Options
ST=Starter 10/2G=#10, 2 Conductors Plus Ground
Product Specications
• UL Listed under Standard 183 for make or break
under load.
• MWS components assembled with 12 AWG/10
AWG conductors rated at 20 amperes with full size
ground wire.
• Copper conductors are THHN insulated wire rated
90°C.
• Galvanized steel exterior with integral keying for
voltage and amperage.
• Unique double-blade contact ensures proper mating
of electrical components to prevent pushback or
pullout.
• Includes threaded locknut connector and 6” pre-
stripped leads on tting ends or at the end of
specied cable length.
• All unused outlets require a MWS dust cover. MWS
ST, SP, SD, CT and TC are shipped with one dust
cover attached.feature bullet
System View (not to scale)
10/3G=#10, 3 Conductors Plus Ground
10/4G=#10, 4 Conductors Plus Ground
12/2G=#12, 2 Conductors Plus Ground
12/3G=#12, 3 Conductors Plus Ground
12/4G=#12, 4 Conductors Plus Ground
09=9'
15=15'
21=21'
[Blank]=No Cable
2N=2 Neutral
(1) 12/4G and 10/4G only.
(1)
Notes
Unit with cable
Starter Fixture Cable Extender or Fixture Cable
Starter Cable
Fixture Cable
Extender or Fixture Cable
Shipping Data
Standard
Cable
Lengths Unit Wt.
0' .7 lbs. 60
9' 3.0 lbs. 9
15' 4.5 lbs. 6
21' 6.3 lbs. 4
Starter (ST)
Converts conventional wiring to MWS. Branch circuits
wire. The Starter is mounted to the junction box with a
1/2" threaded lock nut connector. Circuits are then
connected to the appropriate leads of the Starter.
Starter Cables have 9', 15' or 21' of MC cable.
Consult MWS Installation, Application and Specification
Manual for additional
comprehensive system information.
MWS Autocad Drafting
Please reach out to your local representative
for MWS layout design assistance.
Standard
Qty./Carton
All electrical boxes, conduit, connections
and switches by others.
Install dust covers on unused open ends.
Scale is exaggerated on xtures and MWS
system applications.
PS519291EN page 2
November 21, 2019 4:00 PM