Cooper Lighting Solutions IL506002EN nstallation Instructions

INS #
IL506002EN
Installation Instructions – Lanterra - MB (Ground Mount Recessed Box) Installation Instruction Sheet Directives d’installation – Lanterra – MB (luminaire encastré pour le sol) Feuille de directives d’installation Instrucciones de Instalación – Lanterra - MB (Ground Mount Recessed Box) Installation Instruction Sheet
WARNING
Make Certain Power is OFF before starting installation or attempting any maintenance.
WARNING
Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING
Risk of Personal Injury – Fixture may become damaged and/or unstable if not installed properly.

Do not mount luminaire within 6” of a combustible surface.

Do not handle luminaire by the glass. Do not touch LEDs.
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the
attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.
SAFETY: This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.
APPLICATIONS: This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following recommendations.
Risk of Burn – Disconnect power and allow fixture to cool before servicing.
ote:N These instructions do not claim to cover all
details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
ote:N This lighting fixture has been shipped complete
with one of several mounting options. Please follow the installation instructions specific to the catalog part that you ordered.
ote:N Care must be taken not to set lighting fixture down
on optical lenses or lift the fixture in the lens area.
ote:N Specifications and dimensions subject to change
without notice.
WARNING
WIRING TABLE
POWER SUPPLY (INPUT)
BLACK (BK) - HOT WHITE (WH) - NEUTRAL
GREEN (GN) - GROUND PURPLE (PU) - 0-10V (+) GRAY (GR) - 0-10V (-)
COOPER LIGHTING SOLUTIONS IL506002EN Installation instructions
Installation Instructions – Lanterra - MB (Ground Mount Recessed Box) Installation Instruction Sheet
INSTALLATION
ote:N When possible and not dangerous or hazardous,
crown surface to promote water runoff.
4. Do not place in-ground container in low areas or other
Soil Burial
1. Excavate soil for housing placement and conduit.
areas where water can accumulate and stand for long periods of time. (Figure 3.)
2. Contour shape of hole for housing, allowing for additional 3” minimum under and around hosing for placement of pea gravel.
3. Line bottom and side of hole conduit (see “All Instructions”). Do no bury driver container up to the top of housing cover.
4. Place soil up to bottom of lip. Build up the soil around container to make a crown that will promote water runoff.
5. Do not place in-ground container in low areas or other areas where water can accumulate and stand for long periods of time. (Figure 2.)
All Installations
1. Seal the input and through conduits to prevent water intrusion from conduit to wiring compartment.
2. Mount inlet fitting (two 3/4 NPSM female) to conduit. Use Teflon tape or other sealing compound to seal conduit to prevent water entry.
3. You may use a re-enterable potting compound to temporarily plug conduit entries when pouring re-enterable potting compound.
ote:N Use enclosed dust seal compound to temporarily
plug conduit entries when pouring re-enterable pot­ting compound.
Concrete Pour
1. The in-ground driver housing should be placed on 4” minimum of par gravel, with soil below to promote drainage.
2. Attach in-ground driver to conduit (see “All Instructions”).
4. It is recommended to install 1” conduit at the level of the soil under pea gravel below fixture for better water drainage.
5. Length of the pipe may vary to ensure proper water runoff. Avoid installing the pipe right above the wire conduit.
3. Concrete may be installed up to top of lip.
Top Of Lip For Concrete
Bottom Of Lip For Soil
In-Ground Enclosure
Figure 1.
Fixture Assembly
Knuckle
GN
Screws
Wiring Compartment Cover
Ground Wire
PU
GR
BK
WH
Waterproof Wire Nut
Two 3/4 Npsm Tapped Holes
2
COOPER LIGHTING SOLUTIONS
IL506002EN Installation instructions
Installation Instructions – Lanterra - MB (Ground Mount Recessed Box) Installation Instruction Sheet
Input Wiring
1. Confirm input power requirements with label on the driver compartment.
2. To open Transformer Wiring Compartment, loosen four allen screws with 9/64” hex key.
3. Use input wire rated for at least 90°C
4. Use waterproof wire nuts to connect to input power. See wiring table for reference
5. Strip wires 5/8”. DO NOT pretwist. Twist connector onto wires while pushing firmly until hand tight. DO NOT over torque.
6. Swipe excess sealant in and around conductors. Wire line voltage power to black wire (line), white (common) to white, green (ground) to green wire. If used, connect purple (dim +) and grey (dim -) wires to dimming control. If dimming is not used, cap purple and grey wires seperately with wire nuts.
Slight Grade For Water Runoff
Gravel
Soil
Drainage Pipe
Figure 2.
Through Circuit
Conduit Lines
Slight Grade For Water Runoff
Gravel
Concrete
Drainage Pipe
Through Circuit
Figure 3.
Conduit Lines
3
COOPER LIGHTING SOLUTIONS
IL506002EN Instruct ions d’installation
Directives d’installation – Lanterra – MB (luminaire encastré pour le sol) Feuille de directives d’installation
AVERTISSEMENT
Assurez-vous que l’alimentation électrique est HORS TENSION avant de commencer l’installation ou de tenter d’en faire l’entretien.
Risque de brûlure – Débranchez la source d’alimentation et laissez refroidir le luminaire avant de procéder à son entretien.
AVERTISSEMENT
AVERTISSEMENT
Risque d’incendie ou de décharge électrique. Si vous n’êtes pas qualifié, consultez un électricien.
ote:N Ces directives ne prétendent pas couvrir tous les
détails ou toutes les différences d’équipement, de procédures ou de procédés décrits ni fournir de directives pouvant répondre à toutes les éventualités pouvant survenir pendant l’installation, le
AVERTISSEMENT
Risque de décharge électrique – Mettez l’alimentation électrique hors tension en enlevant le fusible ou en déclenchant le disjoncteur avant l’installation ou l’entretien.
fonctionnement ou l’entretien. Si des renseignements additionnels sont nécessaires afin de résoudre un problème insuffisamment décrit pour l’utilisation, veuillez communiquer avec votre représentant le plus près de chez vous.
ote:N Ce luminaire est livré avec toutes ses pièces et
AVERTISSEMENT
Risque de blessures – Ce luminaire peut s’endommager s’il n’est pas installé correctement ou s’il est instable.

Ne montez pas le luminaire à moins de 15,2cm (6po) d’une surface combustible.

Ne manipulez pas le luminaire en le tenant par le verre. Ne touchez pas aux DEL.
l’une des différentes options de montage. Suivez les directives d’installation correspondant à la pièce du catalogue que vous avez commandée.
ote:N Assurez-vous de ne pas déposer le luminaire sur les
lentilles et de ne pas le soulever en posant vos mains sur les lentilles.
ote:N Les caractéristiques techniques et les dimensions
peuvent changer sans préavis.
IMPORTANT: Lisez attentivement avant d’installer le luminaire. Conservez pour consultation ultérieure.
GÉNÉRALITÉS: Inspectez minutieusement le luminaire dès sa réception pour déceler les dommages occasionnés par
le transport, lesquels devront être signalés au transporteur. Comparez la description du catalogue indiquée sur le bon de livraison avec l’étiquette du luminaire située sur le boîtier pour vous assurer que vous avez reçu l’appareil commandé.
SÉCURITÉ: Le câblage du luminaire doit être conforme au Code national de l’électricité, aux lois et règlements locaux en vigueur. Une mise à la terre adéquate est requise afin d’assurer votre sécurité. Respectez soigneusement la procédure de mise à la terre du chapitre d’installation.
APPLICATIONS: Ce luminaire a été conçu pour l’éclairage extérieur et ne doit pas être utilisé dans un endroit peu ventilé ou dans une enceinte à haute température ambiante. Il doit être rangé dans un endroit sec en attendant son installation. N’exposez pas le luminaire à la pluie, à la poussière ou à d’autres conditions ambiantes avant l’installation et l’insertion de l’interrupteur photo-électrique ou de la fiche de court-circuit (si fournis). N’installez pas le luminaire près de matériaux combustibles et ne le placez pas à proximité de surfaces bloquant la circulation de l’air dans un rayon de 15,2cm (6po). Les résultats seront meilleurs si le luminaire est installé et entretenu selon les recommandations suivantes.
4
SCHÉMA DE CÂBLAGE
ALIMENTATION ÉLECTRIQUE (ENTRÉE)
NOIR (BK) – CHAUD BLANC (WH) – NEUTRE
VERT (GN) – MISE À LA TERRE
VIOLET (PU) – 0 à 10V (+) GRIS (GR) – 0 à10V (-)
Loading...