IB505006EN 049-263
Installation Instructions for the Sure-Lites SEL Emergency Lights
with Remote Capacity
INS #
Sure-Lites
WARNING
Risk of Fire/Electric Shock
If not qualified, consult an electrician.
Important Safeguards
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING
THE FOLLOWING.
1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS
2. Do not use outdoors.
3. Do not use in hazardous locations, or near gas or electric
heaters.
4. Do not let power supply cords touch hot surfaces.
5. Use caution when servicing batteries. Battery acid can
cause burns to skin and eyes. If acid is spilled on skin or in
eyes, flush acid with fresh water and contact a physician
immediately.
6. Do not use this equipment for other than the intended use.
7. Installation is to be performed only by qualified personnel.
8. Install in accordance with National Electric Code and local
regulatory agency requirements.
9. The use of accessory equipment not recommended by the
manufacturer may cause an unsafe condition.
10. Equipment should be mounted in locations and at heights
where it will not readily be subjected to tampering by
unauthorized personnel.
11. SAVE THESE INSTRUCTIONS
MAX MOUNTING HEIGHT:
17.24 FT for SEL25 models
25.39 FT for SEL50 models
27.6 FT for SEL60 models
WARNING
Risk of Electric Shock
Disconnect power at fuse or circuit breaker before
installing or servicing.
INSTALLATION
1. De-energize the circuit at the junction box (J-box) where
the emergency light is to be installed.
2. Open the emergency light by inserting a screwdriver in the
two slots at the bottom of the unit, then tipping the cover
up off of the backplate.
3. To mount to a junction box - Drill out the appropriate
mounting pattern and the wire pass hole in the backplate
to fit the J-box being used.
4. To mount to conduit – Cut out the U shaped knockout on
the cover using snips, then attach the 1/2” conduit hub to
the backplate.
5. Once the backplate is secured, the housing can be held in
place during installation using the EZ Hang feature. (see
Fig. 1)
6. Connect the incoming wires to the fixture’s power supply
wires using the wire nuts provided. Connect the white
wire to neutral. If using 120V, connect the black wire to the
hot lead. If using 277V, connect the orange wire to the hot
lead. Cap the unused lead. Secure the emergency light
to the wall and/or junction box using installer supplied
hardware.
7. Connect the battery to the PCB. See schematic for detail.
8. Snap the cover onto the backplate.
9. Energize AC supply. The test button should illuminate, and
LED heads will illuminate briefly when the test button is
pushed.
10. If the unit has remote capacity, LED remotes can be
connected using the violet (+) and yellow (-) wires. See
schematic.
11. Adjust the heads as needed.
12. If the fixture is to be powered down for an extended
period after initial installation, replace the EZ Key. This
will prevent the battery from discharging when AC power
is removed. However, it will also prevent the battery
from charging when AC power is restored, so it must be
removed once the unit is ready for regular operation.
IB505006EN
OPERATION
Depress the test switch. The
charge LED will extinguish. LED heads will illuminate as long as
the button is pushed. Release the test switch. The charge LED
will illuminate and the LED heads will turn off.
LED heads will remain lit and the
MAINTENANCE
None required. Replace the batteries as needed according
to ambient conditions. However, we recommend that the
equipment be tested regularly in accordance with local codes.
NOTE: Servicing of any parts should be performed by qualified
personnel. Only use replacement parts supplied by Cooper
Lighting Solutions.
CAUTION: This equipment is furnished with a sophisticated low
voltage battery dropout circuit to protect the battery from over
discharge after its useful output has been used. Allow 24 hours
recharge time after installation or power failure for 90 minute
testing.
TROUBLE SHOOTING GUIDE
If LED heads or charge indicator LED does not illuminate, check
the following:
1. Check AC supply – verify that unit has 24 hour AC supply.
2.. Unit is shorted or battery is not connected.
3.. Battery discharged. Permit unit to charge for 24 hour s and
then re-test.
4.. If following the abo ve trouble shooting hints does not
solve your problem, contact your local Cooper Lighting
Solutions representative for assistance.
Figure 1
Slide snaps through holes
in housing for temporary
mount when wiring.
Warranties and Limitation of Liability
Please refer to www.cooperlighting.com for our terms and
conditions.
SCHEMATICS
Remote Heads if
Applicable
Battery
+
-
JK4
+
JK5
-
R5
JK3
D4
D3
R17
JK2
+
-
c
R2
+
R6
-
Q5
C2
R12
+
Q3
RMT
F2
U2
R18
R14
R7
R10
Q4
R15
R16
Q2
CN3
LAMPS
CN2
277120N
R4
R11
R3
R13
C3
+
MOV2
R9
C1
CN1
D2
BATT
U1
D8
J1
R8
MOV1
F1
JK1
CN4
D5
SW1
LED1
D1
D6
D7
Q1
LED/SW
D9
R1
Base Heads -
ORANGE - 277VAC
BLACK - 120VAC
WHITE - NEUTRAL
Mounted on Fixture
SEL with Remote Capacity and Base Heads
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
www.cooperlighting.com
Remote Heads if
Applicable
Battery
+
-
JK4
+
JK5
-
R5
JK3
D4
D3
R17
JK2
+
-
c
R2
+
R6
-
Q5
C2
R12
+
Q3
RMT
F2
U2
R18
R14
R7
R10
Q4
R15
R16
Q2
CN3
LAMPS
CN2
277120N
R4
R11
R3
R13
C3
+
MOV2
R9
C1
CN1
D2
BATT
U1
D8
J1
R8
MOV1
F1
JK1
CN4
D5
LED1
SW1
D1
D6
D7
Q1
LED/SW
D9
R1
Higher Power Heads
ORANGE - 277VAC
BLACK - 120VAC
WHITE - NEUTRAL
- Mounted on Fixture
SEL with Remote Capacity and Higher Power Heads
Cooper Lighting Solutions
© 2020
All Rights Reserved
Printed in USA
Publication No. IB505006EN
Cooper Lighting Solutions is
registered
All trademarks are
of their respective owners.
trademark.
a
property