Lens, Wireguard and
Door frame
POLY125=Polycarbonate Lens
and Door frame
(8) Refer to ambient ratings chart for
temperature requirements. (9) Not
available with narrow distribution
(11) Not available with 48SE or 60SE
configurations. (16) Integrated sensor
not compatible with door frame.
(8), (11), (16)
(8), (9), (11), (16)
(8), (11), (16)
(8), (11), (16)
(8), (9)
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
UNV=Universal
Voltage 120-277
UNC=Universal
Voltage 347/480
(8)
(1) Voltage must be
specified when ordered
with plugs or emergency
driver. (6) Not available
with dual switching.
(10) EM not available
with 36SE, 44SE or 54SE
configurations at 347V
or 480V).
(1)
CCTEmergencyNumber of Relays
(6), (10)
(6), (10)
(6)
70 CRI
L735=3500K
L740=4000K
L750=5000K
80 CRI
L835=3500K
L840=4000K
L850=5000K
EL7W=7-watt, 120V-277V
emergency battery pack
installed
EL14W=14-watt 120V-277V
emergency battery pack
installed
GTR=Bodine Generator
Transfer Device
ETRD=Iota Emergency
Transfer Relay with
dimming control
(4) With integral test switch/
indicator/laser test. For
approximate delivered lumens
multiply the lumens per watt of
the desired fixture by the wattage
of the emergency battery pack
(100 lm/W x 7=700 lumens).
IES-format photometry for
luminaire under emergency operation available. (5) EM options
available in 0°C - 40°C ambient.
(15) Used to transfer fixture to
secondary power during outage.
Must be used in conjunction
with UL 1008 device (provided by
others). These options require 2
relays on fixtures with dimming
drivers. ETRD option only
requires one relay when used on
a dimming fixture. A maximum of
two devices can be used on one
product. 3 or 4 driver products
cannot use GTR.
(5)
Number of Relays
(4)
(4)
(15)
(15)
1=1 relay per driver nondimming only
2=2 relays per driver for
dimming applications
Driver TypeNumber of DriversOptionsMotion SensorsPackagingAccessories
Driver TypeNumber of DriversOptionsMotion SensorsPackagingAccessories (order separately)
CD=0-10V Dimming
(7), (8)
Driver
ED=Electronic Fixed
Output Driver
5LTD=Fifth Light
DALI
(7), (8), (13)
(7)
Notes
(7) Lumen output will
vary depending on
dimming or fixed output
drivers. Refer to IES files
for delivered lumens. (8)
Refer to ambient ratings
chart for temperature
requirements. (13) 5LTD
available with 12, 18, 24,
36 lumen packages only.
1=1 Driver (12,000 and 15,000
lumen versions)
2=2 Drivers (18,000, 24,000
and 30,000 lumen versions)
3=3 Drivers (36,000 lumen CD
(19)
option)
4=4 Drivers (48,000 and 60,000
lumen versions)
(19)
Notes
(19) For 48,000 lumen package, CD
option requires three drivers, ED
option requires four.
MP=Modular Power
Receptacle (used for
all Cord or Cord and
Plug options)
(3)
Notes
(3) Requires use of MC or
MPC cord accessories,
specify voltage for plugs
(MP).
MS=360° or 180° Motion Sensor
Installed, (specify voltage)
SVPD3=Integrated occupancy and
daylight dimming sensor, 1200 sq. ft.
(2), (14), (16), (17)
coverage
LWR=Enlighted Wireless Sensor
(2)
system
ZW-SWPD3=Integrated Wavelinx
Wireless Sensor, 1200 sq ft.
coverage
ZW=WaveLinx Wireless Ready (does
not include sensor)
OEFP010VMV=Occupancy Sensor
with Integrated Photocell
FSP-211/L7-U=PIR Occupancy
Sensor with integral 0-10V dimming
(2)
Notes
(2) When ordering sensors, specify as
UNV (for 120 or 277V), 347 or 480V. (14)
Integrated sensor limited to 36,000 lumens.
(16) Integrated sensor not compatible with
door frame. (17) Integral sensor works only
with “CD” driver and is factory prewired to
the driver for stand-alone control.
HBAYC-CHAIN/SET/U=(2) V-Hook Hangers, 36" Chain Sets w/S-Hooks
MPC3=3' Modular Power Cord & Plug (Specify Voltage)
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify Voltage)
MMS=360° or 180° Aisle Motion Sensor with Modular Power Receptacle
(120-277V)
WG/HBL6-4FT-B=Field Installable, Wireguard for HBLED
ISHH-01=Programming Remote for Integrated Sensor
ISHH-02=Personal Control Remote for Integrated Sensor
SWPD3=WaveLinx Sensor (for field installation into WaveLinx enabled
fixture)
Notes
(10) Not available with lens insert options AI, CLI and FLI or door frame options A, CL and
POLY125. (12) Not available with lens insert options AI, CLI and FLI or doorframe options
A, CL and POLY125.
(12)
PS507030EN page 2
February 23, 2021 5:04 PM
Modular F-Bay Power Supply Option
into existing supply
ccupancy
Cooper
allows
power
all
Product Specications
Construction
• Constructed of channel and end plates with
stiffening brackets and side rails
• Side rails are standard on all HBLED products
Emergency Battery Options
• Optional 120-277V emergency battery available in
7W or 14W
• 90-minute backup period for code compliance
• Test switch with laser pointer and testing from oor
feature for ease of use
• EZ Key feature prevents accidental discharge during
construction
• Generator transfer options available
LED and Light Engine
• Drivers available in 120-277V and 347V
• Optional 0-10V dimming driver is available
Integrated Control Options
• Integral occupancy sensor available with coverage
from 600 sqft up to 1250 sqft
• Maximum mounting height of 30'
• Provides occupancy and closed loop daylight
harvesting
Finish
• Multistage, iron phosphate pretreatment
• Multistage cleaning cycle
Mounting
• Designed for suspension mounting
• Optional wire hook and chain set available
• Single monopoint mounting is available with SPM
tong hanger
HBLED SE
Frame/Shielding
• Optional door frame and lens assembly for added
protection
Compliance
• IC rated for insulation contact
• cULus listed for damp locations -40ºC to 55ºC
ambient environments
• RoHS compliant
• Tested to IESNA LM-79 and LM-80
• Stated life tested to TM21 standards
Warranty
• Five-year warranty standard.
Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply
external xture access for safe and easy servicing. There is no need to remove lamps or reectors to disconnect xture
with F-Bay Modular Power Supply. Access to the individual xture’s power supply allows servicing without turning off
the xtures, disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power.
12
1. Modular Power Supply Receptacle supplied
mounted into xture Access Plate
2. Modular Power Cord & Plugs in 120, 277, 347,
& 480V congurations for easy plug & power
No internal xture
access required for
installation or
disconnecting power
Modular Motion Sensor Option
suppliedwith Mounting Box and
Modular Power Supply Receptacle
Code Compliance
•UL/cUL Certied for Make/Break
under load (UL2549)
• Meets NEC requirements for
ballast disconnect (NEC 410.73G)
• Allows for addition of O
Sensor without hard connections
•Receptacles complete with
insulating/dust cap
PS507030EN page 3
February 23, 2021 5:04 PM
HBLED SE
0˚30˚
˚
˚
˚
˚
20˚
˚
˚
10˚
0˚30˚
˚
˚
˚
˚
20˚
˚
˚
10˚
Photometric Data
HBLED-LD5-24SE-N-UNV-L850-ED2-U
90
Electronic Drive
80
5472
10944
16416
21889
Linear LED 5000K
70
Spacing criterion: (II) 1.27 x mounting height,
(⊥) 0.62 x mounting height
60
Lumens: 23224
50
Input Watts: 154W
Ecacy: 150.8 lm/W
40
Test Report:
HBLED-LD5-24SE-N-UNV-L850-ED2-U. IES
Energy and Performance Data
Catalog Number
HBLED-LD5-12SE-W-UNV-L75012,62977165
HBLED-LD5-15SE-W-UNV-L75016,34295172
HBLED-LD5-18SE-W-UNV-L75019,587122161
HBLED-LD5-24SE-W-UNV-L75024,953154162
HBLED-LD5-30SE-W-UNV-L75032,291193167
HBLED-LD5-36SE-W-UNV-L75037,307232161
HBLED-LD5-48SE-W-UNV-L75051,058299171
HBLED-LD5-60SE-W-UNV-L75062,380386162
Catalog Number
HBLED-LD5-12SE-W-UNV-L85012,20677159
HBLED-LD5-15SE-W-UNV-L85015,79495166
HBLED-LD5-18SE-W-UNV-L85018,930122155
HBLED-LD5-24SE-W-UNV-L85024,116154157
HBLED-LD5-30SE-W-UNV-L85031,209193162
HBLED-LD5-36SE-W-UNV-L85036,057232155
HBLED-LD5-48SE-W-UNV-L85049,346299165
HBLED-LD5-60SE-W-UNV-L85060,289386156
5000K, 70CRI
Delivered
LumensWatts
5000K, 80CRI
Delivered
LumensWatts
Ecacy
(lm/W)
Ecacy
(lm/W)
2096
4193
6289
8386
HBLED-LD5-24SE-W-UNV-L850-ED2-U
90
Electronic Driver
80
Linear LED 5000K
70
Spacing criterion: (II) 1.28 x mounting height,
(⊥) 1.29 x mounting height
60
Lumens: 24116
50
Input Watts: 154W
Ecacy: 156.6 lm/W
40
Test Report:
HBLED-LD5-24SE-W-UNV-L850-ED2-U. IES
Lumen Maintenance
TM-21 Lumen
Ambient
Temperature
Maintenance
(60,000 hours)
55ºC> 84%> 142,000
Shipping Data
Catalog No.Wt.
HBLED-LD5-12SE19 lbs.
HBLED-LD5-15SE19 lbs.
HBLED-LD5-18SE22 lbs.
HBLED-LD5-24SE22 lbs.
HBLED-LD5-30SE22 lbs.
HBLED-LD5-36SE26 lbs.
HBLED-LD5-48SE26 lbs.
HBLED-LD5-60SE26 lbs.
View IES les
Theoretical
L70
(hours)
Ambient Ratings
Lumen Package
HBLED-LD5-12SE55ºC55ºC50ºC40ºC50ºC40ºC40ºC
HBLED-LD5-15SE55ºC55ºC50ºC40ºC50ºC40ºC40ºC
HBLED-LD5-18SE55ºC55ºC50ºC40ºC50ºC40ºC40ºC
HBLED-LD5-24SE55ºC55ºC50ºC40ºC50ºC40ºC40ºC
HBLED-LD5-30SE55ºC55ºC40ºC40ºC50ºC40ºC40ºC
HBLED-LD5-36SE55ºC55ºC40ºC40ºC40ºC40ºC40ºC
HBLED-LD5-48SE40ºC40ºC40ºC40ºC40ºCN/A35ºC
HBLED-LD5-60SE40ºC40ºC35ºC40ºC35ºCN/A35ºC
Ambient
Rated
DriversLensed
EMEDCD5LTDInsertsDoor frame
PS507030EN page 4
February 23, 2021 5:04 PM
Integrated Sensor
The HBLED with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally,
these types of energy savings required coordination between the luminaire and a lighting control system. The HBLED delivers
superior lighting with integrated occupancy and daylighting controls.
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new
construction or retrofit, the HBLED delivers automatic ON to an energy saving light level, while ensuring lighting is turned
OFF when the space is unoccupied.
The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically
adjust the light level based on reflected light beneath the sensor in a closed loop method.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor
programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number:
ISHH-02) provides code compliant manual raise, lower, ON, OFF control.
The HBLED with Integrated Sensor is easy to install with no special wiring and ensures energy savings
out-of-the-box with default control settings.
How it works:
• As the user enters the space controlled by the integral sensor, the lighting turns ON to
• Lighting will remain at that the daylight level until the space is unoccupied. This will start
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the
Energy Saver light level. This adjustable light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.
HBLED SE
100
Energy Savings
Opportunities
(DO)
Daylight Level
Light Level
(ES)
Energy Saver
Light Level
0
Timeout Value
(DU)
Unoccupied Level
Default daylight harvesting set using 36,000 lumen unit at 30 ft. mounting height, 20 ft. spacing for 50 footcandles.
SVPD3 Coverage Pattern
Side View
0
6.1m
[20 ft.]
9.1m
[30 ft.]
12.2m
[40 ft.]
9.1m
[30 ft.]
6.1m
[20 ft.]
3m
[10 ft.]
0
3m
[10 ft.]
6.1m
[20 ft.]
9.1m
[30 ft.]
12.2m
[40 ft.]
(DO)
Daylight Level
OccupiedUnoccupiedOccupiedUnoccupied
Optional Remote
Controls
2. To save press S
3. S
elect O
P
r
o
g
r
a
m
m
i
IS
n
g
H
R
e
H
m
o
-0
t
e
1
LO
HI
SET
ES
MIN
20
50
75
Occ
MAX
To
S
1. R
e
t
5 0, 75, M
aise, Low
Un
O
u
t
Occ
p
u
t
er or P
ax.
ress M
cc or U
E
in.
T
n O
cc
ISHH-01 Remote
R
a
i
L
s
o
e
w
/
e
r
Tim
e
O
u
t
5
10
15
Occ
To
S
Pre
elect
ss the SCEN
The lig h
S
stored li ght l
ting wi ll adju
E
evels..
Per
s
onal
IS
Remote
H
H
-0
2
Raise
Lower
/
S
C
E
N
E
MAX
75
50
MIN
ES
Un
Occ
c
e
nes
button.
st to
ISHH-02 Remote
Control Systems
• WaveLinx
• DLVP
• Enlighted
• iLumin Plus
• VividTune
Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com