Cooper Lighting Solutions EC-010V User Manual

Project Catalog # Type
[19mm]
[16mm]
Prepared by Notes Date
MWS
EC-010V
Extender Cable with 0-10V Dimming Modular Wiring System
Typical Applications
Flex cable with integral 0-10V
dimming cable
Oce • Education • Hospitality • Retail • Industrial • Manufacturing • Sports
Venues
Interactive Menu
Product Certication
Order Information page 2
Product Specications page 2
• System View page 2
• Product Warranty
Top Product Features
• UL Listed under Standard 183 for make or break under load
• Meets requirements of Article 604 of the National Electrical Code
• Rated at 20 amperes with full-size ground wire
• Galvanized steel exterior with integral keying for voltage
Dimensional and Mounting Details
Front
Front
1-7/8"
[47mm]
5/8"
4-3/8"
[112mm]
4-3/8"
[112mm]
To p
Side
3/4"
additional product diagrams
PS519313EN page 1
December 2, 2019 2:09 PM
EC-010V
Cooper Lighting Solutions
1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800
www.cooperlighting.com
© 2020 Cooper Lighting Solutions All
Rights Reserved.
Specifications and dimensions subject to change without notice.
Order Information
Starter Extender Cable
SAMPLE ORDER NUMBER: 27EC12/3G17-010V
Voltage
Voltage Component Conductors and Size Cable Length (Feet) Dimming
12=120V 27=277V 34=347V
Component Conductors and Size Cable Length (Feet) Dimming
EC=Extender Cable 10/2G=#10, 2 Conductors Plus Ground
12/2G=#12, 2 Conductors Plus Ground
Product Specications
• UL Listed under Standard 183 for make or break under load
• MWS components assembled with 12 AWG/10 AWG conductors rated at 20 amperes with full size ground wire
• 0-10V Dimming wires 16AWG
• Copper conductors are THHN insulated wire rated 90°C
• Galvanized steel exterior with integral keying for voltage and amperage
• Unique double-blade contact ensures proper mating of electrical components to prevent pushback or pullout
System View (not to scale)
Circuit T
Extender Cable
Drop SO Cord
Extender Cable (EC)
Supplies power between MWS components. Cables connect together without use of couplers.
Typical MWS Wiring System Application shown utilizing Extender Cable (EC).
Consult MWS Installation, Application and Specification Manual for additional comprehensive system information.
07=7' 11=11' 17=17' 21=21' 26=26' 31=31' 36=36' 41=41'
• Supplies power between MWS components without use of couplers
• All unused outlets require a MWS dust cover. MWS ST, SP, SD, CT and TC are shipped with one dust cover attached
• Copper power and control/signal conductors
• Meets the NEC and UL listing requirements for combining power/lighting circuits and class 2 or class 3 signal/control circuits in the same cable
Fixture CableSwitch Drop
Fixture
Extender Cable
Switch Drop
Fixture Cable
Fixture Cable
Cable
010V=0-10V Dimming
Shipping Data
Standard
Cable
Lengths Unit Wt.
5' 2.0 lbs. 12
7' 2.5 lbs. 10
9' 3.0 lbs. 9
11' 3.5 lbs. 8
13' 4.0 lbs. 7
15' 4.5 lbs. 6
17' 5.0 lbs. 6
19' 5.6 lbs. 5
21' 6.3 lbs. 5
26' 7.8 lbs. 4
31' 9.3 lbs. 4
36' 10.3 lbs. 4
41' 12.3 lbs. 4
MWS Autocad Drafting
Standard
Qty./Carton
Please reach out to your local representative for MWS layout design assistance.
All electrical boxes, conduit, connections and switches by others.
Install dust covers on unused open ends.
Scale is exaggerated on xtures and MWS
system applications.
PS519313EN page 2
December 2, 2019 2:09 PM
Loading...