DESCRIPTION
Catalog #
Project
Comments
Prepared by
Type
Date
Corelite
The next generation of lighting is here with the architecturally inspired Divide™ The next generation of lighting is here with the architecturally inspired Divide™
2-1/4”
[57mm]
23-3/4” [603mm]
series powered by WaveStream™ LED. The broad offering of efficient LED series powered by WaveStream™ LED. The broad offering of efficient LED products include a complete family of recessed, linear suspended, surface, and products include a complete family of recessed, linear suspended, surface, and wall mounted luminaires. The Divide’s modern, ultra-shallow design is comple-wall mounted luminaires. The Divide’s modern, ultra-shallow design is comple- mented with functionally engineered features for practical use. High perform-mented with functionally engineered features for practical use. High perform- ing Accu-Aim™ optics allow for maximum energy savings while achieving ing Accu-Aim™ optics allow for maximum energy savings while achieving desired light levels. Available in 1x4, 2x2 and 2x4 sizes, the Corelite Divide desired light levels. Available in 1x4, 2x2 and 2x4 sizes, the Corelite Divide Recessed Series is ideal for open offices, private offices, retail, healthcare and Recessed Series is ideal for open offices, private offices, retail, healthcare and educational facilities.educational facilities.
Construction
Flat panel construction measures Flat panel construction measures just 1” deep combined with integral just 1” deep combined with integral center gear tray for total fixture center gear tray for total fixture depth of 2-1/4”. Housing is extruded depth of 2-1/4”. Housing is extruded aluminum and die-formed 20 aluminum and die-formed 20 gauge cold rolled steel. Integral gauge cold rolled steel. Integral gear tray measures 3-3/8” wide and gear tray measures 3-3/8” wide and accommodates electronic driver and accommodates electronic driver and optional emergency devices. Fixture optional emergency devices. Fixture weight = 28.0 lbs.weight = 28.0 lbs.
Optics
Optical grade acrylic embedded with Optical grade acrylic embedded with patented Accu-Aim™ micro-optics patented Accu-Aim™ micro-optics for optimal distribution, low glare, for optimal distribution, low glare, and high performance. Specular and high performance. Specular (WS) or diffuse (WD) optical patterns (WS) or diffuse (WD) optical patterns are available to achieve the right are available to achieve the right
23-3/4”
[603mm]
47-3/4” [1213mm]
look for any application. See page look for any application. See page 3 Photometric data for optical 3 Photometric data for optical performance.performance.
Finish
Fixture housings and back reflector Fixture housings and back reflector are high reflectance white using are high reflectance white using electrostatically applied polyester electrostatically applied polyester powder coat paint. Optional powder coat paint. Optional antimicrobial paint (AM option) antimicrobial paint (AM option) resists bacterial growth on exposed resists bacterial growth on exposed painted surfaces.painted surfaces.
Electrical
LED light engines located on outer LED light engines located on outer edge of fixture for ideal thermal edge of fixture for ideal thermal management and increased product management and increased product life. Projected life is 100,000 hours life. Projected life is 100,000 hours at 87% lumen output. LED’s are at 87% lumen output. LED’s are
available in 3000K, 350 0K or 4000K available in 3000K, 350 0K or 4000K with CRI options of either ≥80CRI or with CRI options of either ≥80CRI or ≥90CRI. Standard drivers are 0-10 ≥90CRI. Standard drivers are 0-10 volt continuous dimming that work volt continuous dimming that work with any 0-10V control/dimmer. Or, with any 0-10V control/dimmer. Or, specify Digital Addressable Lighting specify Digital Addressable Lighting Interface (DALI) drivers; for use with Interface (DALI) drivers; for use with Fifth Light controls. See Ordering Fifth Light controls. See Ordering Information for details.Information for details.
Mounting
Universal flange design works with Universal flange design works with most lay-in ceiling types. Integral most lay-in ceiling types. Integral Pry-out tabs secure luminaire to Pry-out tabs secure luminaire to ceiling grid from above. Fixture ceiling grid from above. Fixture offers tie-in locations for tie-wire offers tie-in locations for tie-wire on all corners. Consult local on all corners. Consult local code for appropriate tie-wire code for appropriate tie-wire recommendations. See Technical recommendations. See Technical Notes section for drywall frame kit Notes section for drywall frame kit and surface mount kit options.and surface mount kit options.
Compliance
Components are UL recognized Components are UL recognized and luminaires are cULus listed for and luminaires are cULus listed for 25°C ambient environments , damp 25°C ambient environments , damp location listed, and RoHS compliant. location listed, and RoHS compliant. DesignLights Consortium™ Qualified DesignLights Consortium™ Qualified and classified for DLC Standard and classified for DLC Standard and DLC Premium, refer to and DLC Premium, refer to www.www. designlights.orgdesignlights.org for details. for details.
Warranty
Five-year warranty.Five-year warranty.
DIVIDE - DRI
WaveStream™ LED
2’ x 4’ Recessed
2-1/4” Depth
CERTIFICATION DATA
cULus - 1598
Damp Location Listed
DesignLights Consortium™Qualified
IC Rated
ROHS Compliant
ORDERING INFORMATION
Sample Number: DRI-WS-2L935-UNV-24-T1-STD-SVPD1-EL14W-AM
(1)(2)
Series
=
DRI
Divide Recessed WS = WaveStream Specular Optic
Ceiling Type Driver Type
=
T1
1” T-Bar, Slot Grid, and
9/16” Tegular
(4)
See page 2 for technical notes
Optics
=
WD
WaveStream Diffuse Optic
STD = Standard 0-10V (10%-100%)
=
HCD
0-10V (1%-100%)
STP = Step Dimming (Bi-Level, 50%) 5LT = Fifth Light DALI (10%-100%) 5LTHD = Fifth Light DALI (1%-100%) SR = Sensor Ready (5%-100%)
(6)
(5)(8)
(2x4 Nominal delivered lumens)
=
1
=
2
=
3
=
4
=
5
SVPD1
(7)
SWPD1 = WaveLinx Wireless Integral
(5)
LWIPD1 = Lumawatt Pro Wireless Inte-
Light Level
Light Level 1 (30 00 Lms, 23W) Light Level 2 (40 00 Lms, 31W) Light Level 3 (50 00 Lms, 40W) Light Level 4 (60 00 Lms, 49W) Light Level 5 (70 00 Lms, 62W)
Integral Sensor
=
Integrated Occupancy/Daylight
Sensor for Local Control
Sensor
gral Sensor
(Optional)
(10) (14)
(11) (14)
Color
Temperature
=
3000K, 80 CRI
L830
=
L835
3500K, 80 CRI
=
L840
4000K, 80 CRI
=
L930
3000K, 90 CRI
=
L935
3500K, 90 CRI
=
L940
4000K, 90 CRI
EL14W = 14-watt 120V-277V
(9) (14)
RRU = UL924 Bypass Relay
Input Voltage Size
=
UNV
Universal
(120V-277V)
=
347
347V
Emergency
(Optional)
Integral EM Battery Pack
(13)
24 = 2’ x 4’
(3)
Options
AM = Anti-microbial Coating
(12)
=
CP
Chicago Plenum
=
W6
6’ Whip Flex
=
W12
12’ Whip Flex
PS518004EN
04/22/2020
1 of 4
Speci
fications and dimensions
subject to change without notice.
Divide - DRI 2x4
TECHNICAL NOTES
1. DesignLights Consortium™ Qualified and classified for DLC Standard and DLC Premium, refer to www.designlights.org for details.
2. Dimming wires come standard in all LED fixtures but can be capped in the field for standard switched operation.
3. Integral 347V electronic driver with STD 0-10V option only. Factory supplied remote transformer for all other driver/dimming options.
4. “T1” ceiling type is compatible with Metalux DF Series Drywall Frame Kits and Metalux Univer sal Surface Mount Kits, ordered separately from
Metalux. For 2x4 drywall frame kit, order part #DF-24-W. For 2x4 surface mount kit, order part #SK-24-WS.
5. Must be used in conjunction with a DALI control system. For a complete listing of Fifth Light Tec hnology products and other solutions from Cooper Lighting Solutions, visit www
.cooperlighting.com
6. 2x4: Two HCD drivers required for Light Level 5.
7. 2x4: STP driver not available in Light Level 1.
8. 2x4: Two FLTHD drivers required for Light Levels 4 and 5.
9. SV sensor works only with 0-10V drivers and is factory prewired to the driver for stand-alone control. Order part #ISHH-01 for Programming
Remote and part #ISHH-02 for Personal Control Remote.
10. SW sensor works only with STD and HCD 0-10V drivers. Designed for use with the WaveLinx Wireless Connected Lighting system. F or complete WaveLinx wireless solutions, visit www.cooperlighting.com
11. LWI sensor option requires the use of the SR driver. Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt P ro wireless solutions, visit www.cooperlighting.com
12. Integral emergency battery pack is 14W maximum, 90 minute output. A test switch/indicator but ton can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. For approximate deli vered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 14=1400 lumens)
13. Used to bypass local control during outage. Must be used in conjunction with UL 1008 device (provided by others).
14. When luminaire is used on an emergency circuit, integrated sensors require the RRU Emergency Option to disable sensor control during emergency.
LUMEN MAINTENANCE
Ambient
Temperature
TM-21 Lumen
Maintenance
(100,000 hours)
25°C >87% 256,000
Theoretical
L70
(Hours)
ENERGY AND PERFORMANCE DATA
2x4 – Divide Light Level Outputs and Distributions (3500K)
Series
Light Level
Delivered
Lumens
Wattage
Efficacy
(LPW)
1 3078 23.1 133
2 4131 31.3 132
DRI-WS
3 5182 40.3 129
4 6238 49.9 125
5 7408 61.7 120
1 3 116 22.9 136
2 4182 31.3 133
DRI-WD
3 5246 40.3 130
4 6316 49.9 127
5 7500 61.7 122
Cooper Lighting Solutions
1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800
www.cooperlighting.com
PS518004EN
04/22/2020
2 of 4
Specifications and dimensions subject to change without notice.
90°
90°
PHOTOMETRICS
Divide - DRI 2x4
1194
1592
1270
1693
FILE NAME: DRI-WS-3L835-UNV-
0
398
796
30°
15°
0º (II)
-----
90º ( I ) --------------------------
75°
60°
45°
LUMENS: 5182 Lm
EFFICACY:
TEST NO.:
24-T1-STD.IES
LAMP: (LD2) LED 3500K
40.3 W
WATTS:
129 Lm/W
P189129
SC: (II) 1.35, ( l ) 1.37
FILE NAME: DRI-WD-3L835-UNV-
0
423
75°
24-T1-STD.IES
LAMP: (LD2) LED 3500K
LUMENS: 5246 Lm
847
30°
15°
0º (II)
90º ( I ) --------------------------
45°
-----
60°
EFFICACY:
TEST NO.:
WATTS:
SC:
40.3 W
130 Lm/W
P189097
(II) 1.29, ( l ) 1.29
ZONAL LUMENS SUMMARY
LUMINANCE DATA
(CD/M2)
Vertical
Zone Lumens% Fixture
Angle 45º 90º
0º-30º 1291 24.9 45º 2707 2676 2691
0º-40º 2163 41.7 55º 2734 2652 2656
0º-60º 3970 76.6 65º 2687 2555 2615
0º-90º 5182 100 75º 2458 2307 2458
85º 1728 1473 1505
ZONAL LUMENS SUMMARY
LUMINANCE DATA
(CD/M2)
Vertical
Zone Lumens% Fixture
Angle 45º 90º
0º-30º 1324 25.2 45º 2660 2656 2687
0º-40º 2190 41.7 55º 2661 2661 2715
0º-60º 3991 76.1 65º 2608 2615 2753
0º-90º 5246 100 75º 2448 2458 2728
85º 1728 1633 1665
WAVESTREAM ACCU-AIM OPTIC PATTERNS
WS - Specular
WD - Diffuse
Cooper Lighting Solutions
1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800
www.cooperlighting.com
PS518004EN
04/22/2020
3 of 4
Speci
fications and dimensions
subject to change without notice.
SVPD1 INTEGRATED SENSOR
Top View
Side View
[1
[12 ft.]
Major Motion
Recommended Mounting Height 8–12 ft.
Light Level
Ta rget light level default: 500 lux at 8 ft.
The Divide with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Divide delivers superior lighting with integrated occupancy and daylighting controls.
Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Divide delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied.
The integral daylight sensor reduces the need for special daylight zone planning. The luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method.
Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control.
The Divide with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings.
Divide - DRI 2x4
How it works:
• As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level.
• Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes).
• If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable
light level is typically half of the occupied daylight level.
• At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting.
100
Energy Savings
Opportunities
(DO) Daylight Level
(ES) Energy Saver Light Level
0
Timeout Value
(DU) Unoccupied Level
(DO) Daylight Level
OccupiedUnoccupiedOccupiedUnoccupied
Coverage
C
4m
2 ft.]
Coverage
L
3.3m
[10 ft.]
0m
[0 ft.]
4m
Optional Remote Controls
Raise/
Lower
LO
10
HI
SET
15
ES
MIN
20
50
75
Occ
MAX
To Set Output
1. Raise, Lower or Press Min.
50, 75, Max.
Un
2. To save press SET
Occ
3. Select Occ or Un Occ
Programming Remote
ISHH-01
ISHH-01 Programming Remote ISHH-02 Personal Control Remote
Cooper Lighting Solutions
1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800
www.cooperlighting.com
5
Time
Out
0m
[0 ft.]
4m
[12 ft.]
0m
[0 ft.]
4m
[12 ft.]
Person al Remo te
ISHH-02
Occ
To Select Scenes
Press the SCEN E but ton.
The lig htin g wi ll ad just to
stored li ght l evels ..
Raise/
Lower
SCENE
MAX
75
50
MIN
ES
Un
Occ
PS518004EN
04/22/2020
4 of 4
Loading...