ADE141891
INS #
Installation Instructions – Junction Box Interface (Connection at
Ceiling) Pendant Pipe Mounting PP-_-JB
Instructions d’installation – Montage sur tuyau suspendu PP-_-JB
de l’interface de la boîte de jonction (connexion au plafond)
Instrucciones de instalación de la interfaz de la caja de derivación
(conexión en el techo) Montaje de tubo de suspensión PP-_-JB

WARNING
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION
INSTRUCTIONS.
Installation Instructions – Junction Box Interface (Connection at Ceiling) Pendant Pipe Mounting PP-_-JBInstallation Instructions – Junction Box Interface (Connection at Ceiling) Pendant Pipe Mounting PP-_-JB
INSTALLATION
Mount Details
Before starting any work ensure that all sources of power are turned OFF. . All work must meet local/national electrical
codes and be performed by a certified electrician.
Follow product label information and instructions before installing fixture. Retain installation instructions for future
reference.
Risk of fire, electrical shock, cuts and or other casualty hazards. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction and operation of the product and the hazards
involved. Cooper Lighting Solutions assumes no responsibility for claims brought about by improper or careless
installation or handling of this product.
Risk of burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
Replace lamp only with correct wattage and type of lamp marked on label. DO NOT exceed the maximum wattage listed
on the fixture label.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
NOTICE
If supply wires are located within 3 inches of driver/ballast, use wire rated for at least 90°C (194°F).
Note:
Not all option available. Please consult your Cooper Lighting Solutions representative for availability. Specification
and dimension subject to change without
notice.
4” Octagonal
Box to Structure
(By Others)
Figure 1.
1/4 IPS Nut
1/2” Pendant
Power
Pendant Wire
(By Others)
Connection at Ceiling
1. Layout mounting locations.
2. Ensure that power feed is at the UL end of the fixture.
Power feed: to be installed to local/national electrical
codes by a Certified Electrician.
3. Secure junction boxes to structure.
4. Secure crossbar to junction box.
5. Attach pendant to crossbar using 1/4” IPS lock nut.
6. Feed wires through pendant to allow access in junction
box and connect wires ensuring all connections are
properly matched.
7. Slide canopy up pendant and tighten set screw.
ote:N Nominal ID for 1/4 IPS = 9.5 mm, 0.375 in.
ote:N Power wires can run through any pendant. (Refer to
local/national electrical codes).
ote:N Contact Corelite for connecting power at a joint for
Navigator II.
Figure 3.
Figure 4.
Power (2-D)
Non-Power (2-D)
Mounts Locations
Distances are Equal to Fixture Length Plus or
Fixture Family DIM “A” DIM “B” DIM “C” DIM “D”
Class A - 1 1/8” - 1 1/8” 0” 0”
Radius - 1 1/8” - 1 1/8” 0” 0”
Iridum - 1 1/8” - 1 1/8” 0” 0”
Stellar - 2 3/8” - 2 3/8” 0” 0”
RZL - 2 3/8” - 2 3/8” 0” 0”
Minigator - 1 1/8" - 1 1/8” 0” 0”
Navigator II + 5/8” - 5/16” 0” + 15/16”
Single Fixture
DIM “A“
Minus Dimensions Below
Installation Instructions – Junction Box Interface (Connection at Ceiling) Pendant Pipe Mounting PP-_-JB
ADE141891 www.cooperlighting.com
Figure 2.
5’’ Canopy
W/Slip Ring
Non-Power
Sample Row
DIM “B“
Crossbar
Installation Instructions – Junction Box Interface (Connection at Ceiling) Pendant Pipe Mounting PP-_-JB
ADE141891 www.cooperlighting.com
*For continuous rows see joining sheet
Figure 5.
Mounts Locations
DIM “C“ DIM “D“
32