ADE141261
Installation Instructions – Junction Box Structure Interface
(Connection at Ceiling) Aircraft Cable Mounting AC-_-ST
Instructions d’installation - Montage sur câble d’aéronef AC-_-ST
de l’interface de structure de la boîte de jonction (connexion au
plafond)
Instrucciones de instalación de la interfaz de la estructura de la caja
de derivación (conexión en el techo) Montaje de cable aeronáutico
AC-_-ST
Installation Instructions – Junction Box Structure Interface (Connection at Ceiling) Aircraft Cable
Mounting - AC-_-ST
WARNING
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION
Before starting any work ensure that all sources of power are turned OFF. All work must meet local/national electrical
codes and be performed by a certified electrician.
Follow product label information and instructions before installing fixture. Retain installation instructions for future
reference.
Risk of fire,
electrical shock, cuts and or other casualty hazards. This product must be installed in accordance with the
applicable installation code by a person familiar with the construction and operation of the product and the hazards
involved. Cooper Lighting Solutions assumes no responsibility for claims brought about by improper or careless
installation or handling of this product.
Risk of burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
Replace lamp only with correct wattage and type of lamp marked on label. DO NOT exceed the maximum wattage listed
on the fixture label.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
INSTRUCTIONS.
NOTICE
If supply wires
are located within 3 inches of driver/ballast, use wire rated for at least 90°C (194°F).
Note: Not all option available. Please consult your Cooper Lighting Solutions representative for availability.
Specification and dimension subject
to change without notice.
Installation Instructions – Junction Box Structure Interface (Connection at Ceiling) Aircraft Cable Mounting - AC-_-ST
2
ADE141261 www.cooperlighting.com
Installation Instructions – Junction Box Structure Interface (Connection at Ceiling) Aircraft Cable
INSTALLATION
Mount Details
1/4-20 Stud
to Structure
(By Others)
1/4-20
Coupler
Crossbar
Aircraft
Cable
5’’
Canopy
4’’ Octagonal J-Box
and Appropriate
Hardware to
Structure (By Others)
Crossbar with
1/4-20 Thread
Structure
2’’ Canopy
(Not Provided Standard)
Figure 2.
Non-Power
Mounting - AC-_-ST
1/4-20 Stud to
Structure (by Others)
1/4-20 Pan Head
Screw
Figure 1.
Strain
Relief
Power
Connection at Ceiling
1. Layout mounting locations. (Figure 1.)
2. Ensure that power feed is at the UL end of the fixture.
ote:N Power feed: to be installed to local/national
electrical codes by a Certified Electrician.
3. Secure junction box and 1/4-20 stud to structure.
4. Secure crossbar to junction box.
5. Feed power cables through canopy and install strain
relief.
6. Connect power cable in junction box, ensuring all
connections are properly matched.
7. Place canopy over junction box & fasten with 1/4-20
pan head screw.
8. Install 1/4-20 coupler with aircraft cable to 1/4-20 stud.
Figure 3.
Figure 5.
Figure 6.
Power (2-D)
Options
Figure 4.
Curly Cord (AK):
SJT - 18/3 or
SJT - 18/4
Curly Cord
Non-Power (2-D)
Power Mount
Option with AC48
Aircraft Cables Sit in .368’’ from the End of the Fixture
Mounting Points Equal Fixture
Lengths 4’, 8’ or 12’
Power Feed
First Section
Figure 7.
Mounts Locations
Installation Instructions – Junction Box Structure Interface (Connection at Ceiling) Aircraft Cable Mounting - AC-_-ST
ADE141261 www.
Mounting Points Equal Fixture
Lengths 4’, 8’ or 12’
*Consecutive Section
*For Continuous Rows See Joining Sheet
cooperlighting.com
3