Cooper Lighting VT3-232, VT3-354, VT3-132, VT3-254, VT3-154T5 User Manual

...
Catalog #
Project
Comments
Prepared by
Date
SPECIFICATION FEATURES
10/06/2008 11:40:01 AM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF071376
LAMP CONFIGURATIONS
INSTALLATION DATA
MOUNTING DATA
DESCRIPTION
The VT3 Series is a contemporary looking energy efficient industrial
Vaportite fixture that features rugged and durable construction. The VT3
incorporates a full metal clear tray inside a reinforced fiberglass housing
with a high impact diffuser. This Vaportite series is suitable for interior and
exterior applications and can be surface or chain mounted.
The VT3 Series has been designed for maximum operation in commercial
institutional and industrial environments where weathering, high
temperature, humidity and dust or corrosive fumes are present.
A ... Construction
Fiberglass housing is reinforced
polyester and self-extinguishing
(ASTM-D635-74) plastic of a
permanent pearl gray color. Top of
housing has five embossments (2'
unit), nine embossments (4' unit)
and thirteen embossments (8'
unit), providing mounting flexibi-
lity on uneven surfaces. A watertite
hub for 1/2" conduit entry is
provided at each end of housing
(standard) for continuous feed.
Polyurethane gasketing is formed
in the housing providing a
continuous seamless seal for the
diffuser. Six sturdy cam latches
clamp diffuser tightly for a positive
seal between housing, gasketing
and diffuser.
B ... Electrical*
Unit has full metal gear tray
secured by internal fasteners and
tethers providing maximum
protection and rigidity. Ballasts are
CBM/ETL Class "P" certified
suitable to 70°F. (Cold temperature
ballasts are available for less than
0°F starting with EHT (T5HO only),
EB/PLUS and ER/PLUS Ballasts).
Rotor lock lampholders. Electrical
components and fixtures are
UL/CUL listed for Wet Locations.**
IP65 approved with optional IP67
rating (4' only) with 8 latches.
C ... Shielding
New contemporary styled lens
clear acrylic w/impact resistant
additives and linear prisms.
"DR" - Clear low brightness pattern
acrylic with 15% high impact
additive.
"DR-100" - Clear low brightness
pattern acrylic with 100% high
impact additive. Example:
VT3-232DR-100
VT3
132 232
332 154T5 254T5
4' INDUSTRIAL
1, 2 OR 3 LAMP
Vaportite Industrial
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
EB Ballast & STD Lamps
132 (30) 232 (61) 154T5 (54) 254T5 (106)
Luminaire Efficacy Rating
LER = FI-73 Catalog Number: VT3-232DR
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.29
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
**Not Suitable for Wet Locations if EL4 Option is added. Consult Pre Sales Technical Support.
E N ER G Y D AT A
Input Watts:
4-13/16"
[123mm]
6-15/16"
[177mm]
A B C
4-13/16"
[123mm]
X
6-15/16"
[177mm]
X=1-13/32"
[36mm]
4-13/16"
[123mm]
X
6-15/16"
[177mm]
Y
Y=2-1/2" [64mm]
X=1-13/32"
[36mm]
4-13/16"
[123mm]
X
6-15/16"
[177mm]
Y=2-1/2" [64mm]
Y
X=1-13/32"
[36mm]
MOUNTING BRACKETS
Furnished Two per
4' Unit Four per
8' Unit
OPTIONAL CHAIN HANGING SET
(VT2-CHAIN/SET-U) Includes 6 ft. of chain, 4 large
S-Hooks and 4 small S-Hooks Order One (1) Kit for each 4' Fixture Two (2) Kits Recommended For
8' Fixture
Relative Light Output Factors
To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. The relative light output factor should be applied as an additional light loss factor component.
VT3 Series
-15°F (-26°C) 0°F (-18°C) 20°F (-6°C) 33°F (0°C) 50°F (10°C)
VT3-232 0.67 0.97 0.99
VT3-254 0.73 0.76 0.86 0.90 0.94
VT3-332 0.96 0.98 0.98
VT3-354 0.91 0.93
6-5/8"
[168mm]
49-13/16" [1265mm]
X
Y
X=5-3/8" [137mm]
Y=4-3/16"
[107mm]
41-1/2" [1054mm]
Optional Back Hub
Locations
38-3/4" [984mm]
1/4" x 28" Stud
(2 Places)
COOPER LIGHTIN G - ME TA LU X
®
Specifications and Dimensions subject to change without notice.
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
VT3
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180
Candela
Angle Along II 45° Across 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
VT3-232DR-UNV­EB81-WL-U
(1) Electronic Ballasts (2) 32W T8 lamps
2850 lumens Spacing criterion:
(II) 1.3 x mounting height, ( ) 1.5 x mounting height
Efficiency 77.4% Test Report:
LTL10864.IES LER =FL72 Yearly Cost of 1000
lumens, 3000 hrs at .08 KWH = $3.34
1103 1103 1103 1097 1108 1107 1083 1107 1106 1059 1091 1127 1025 1089 1113
983 1058 1098 932 1035 1088 870 991 1052 801 952 1024 725 892 971 640 831 920 548 753 878 451 683 814 352 611 771 251 550 698 155 471 592
77 367 513 28 290 427
6 217 342
91 91 91 91 89 89 89 89 84 84 84 79 79 79 75 75 75 73 82 78 74 70 79 75 72 69 71 68 66 67 65 63 64 62 60 58 74 67 61 56 71 65 60 55 61 57 53 58 54 51 55 52 49 47 67 58 52 46 65 57 51 46 54 49 44 51 47 43 49 45 42 40 61 51 44 39 59 50 43 38
48 42 37 45 40 36 43 39 35 33 56 45 38 32 54 44 37 32 42 36 31 40 34 30 38 33 30 28 51 40 33 28 49 39 32 27 37 31 27 36 30 26 34 29 26 24 47 36 29 24 45 35 28 23 33 27 23 32 27 23 30 26 22 20 43 32 25 20 42 31 25 20 30 24 20 29 23 19 27 23 19 17 40 29 22 17 38 28 22 17 27 21 17 26 20 17 25 20 16 15 37 26 20 15 36 26 19 15 24 19 15 23 18 15 22 18 14 13
899 15.8 20.4 1512 26.5 34.3 2847 49.9 64.5 4169 73.1 94.5 4413 77.4 100.0
Luminance D ata
Average Average Average Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm
45 5519 7213 7212 55 5083 6756 7098 65 4347 6377 7074 75 30 01 6097 6510 85 1349 5151 6092
Coefficients of Utilization
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
Luminance D ata
Average Average Average Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm
45 7704 10245 10279 55 7142 9700 9531 65 6126 8631 10102 75 4240 9114 10293 85 2265 7674 8760
Zonal Lumen Summary
Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180
Candela
Angle Along II 45° Across 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
VT3-254T5DR-UNV­EHT1-WL-U
(1) Electronic Ballasts (2) 54W T5 lamps
4400 lumens Spacing criterion:
(II) 1.2 x mounting height, ( ) 1.5 x mounting height
Efficiency 69.7% Test Report:
LTL10777.IES LER =FL59 Yearly Cost of 1000
lumens, 3000 hrs at .08 KWH = $4.05
1546 1546 1546 1540 1525 1533 1519 1548 1525 1483 1514 1546 1436 1509 1566 1375 1487 1530 1300 1446 1509 1215 1396 1502
1118 1315 1425
1012 1267 1384
896 1174 1308 770 1081 1179 634 954 1107 496 827 1101 352 771 1044 219 704 936
113 578 807
47 432 614 13 285 431
82 82 82 82 80 80 80 80 76 76 76 72 72 72 69 69 69 67 74 70 66 63 72 68 65 62 65 62 59 61 59 57 58 57 55 53 66 60 55 50 64 58 54 49 55 51 48 53 49 46 50 47 45 43 60 52 46 41 58 51 45 41 49 44 40 46
42 39 44 41 38 36 55 46 40 35 53 45 39 34 43 38 33 41 36 33 39 35 32 30 50 40 34 29 48 40 33 29 38 32 28 36 31 27 34 30 27 25 46 36 29 25 44 35 29 24 34 28 24 32 27 24 31 26 23 22 42 32 26 21 41 32 25 21 30 25 21 29 24 20 28 23 20 18 39 29 23 18 38 28 22 18 27 22 18 26 21 17 25 20 17 16 36 26 20 16 35 25 19 15 24 19 15 23 18 15 22 18 15 13 33 23 18 14 32 23 17 14 22 17 13 21 17 13 20 16 13 12
1253 14.2 20.4 2112 24.0 34.4 3985 45.3 64.9 5908 67.1 96.3 6137 69.7 100.0
SAMPLE NUMBER: VT3-232DR-UNV-EB81 -WL-U
Tandem Blank= 4' Length 8T=8' Length
Series VT3=Vaportite
Number of Lamps
(3)
1, 2 or 3 Lamps
(Not included)
Wattage (Length) 32=32W T8 (48") 28T5=28W T5 (48") 54T5=54W T5HO (48")
(5)
Lens DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-50=50% High Impact Additive (High Impact) DR-100=100% High Impact Additive (Extreme)
Voltage
(1)
120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal
Voltage 120/277
(2)
UNC=Universal
Voltage 347/480
WL=Wet Label
GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed
(3), (4)
Options 8L=8 Latches (IP67 Rating) M4=Miro 4 Interior Reflector RIF1=Radio Interference
Suppressor TH=(2) Top Watertite Hubs only, no End Hubs
(5)
TEH=(2) Top & (2) End
(5)
Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry)
SSL=Stainless Steel Latches
Packaging U=Unit Pack
Ballast Type
(1), (4)
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EBT
= T5 Linear Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EHT
= T5 Linear Electronic Start High Ambient.
Total Harmonic Distortion < 10%
No. of Ballast 1 or 2
No. of Ballast 1 or 2
No. of Ballast 1 or 2
No. of Ballast 1 or 2
No. of Ballast
(3)
1 or 2
NOTES:
(1)
Products also available in non-US voltages and frequencies for international
markets.
(2)
Not available when specifying emergencies, voltage must be specific.
(3)
3 Lamp 54W T5HO is recommended for ambient temperatures below 102°F (40°C) with EHT2 ballasts, and below 0°F (-18°C) with EHT1 ballast.
(4)
Emergency option in 3 lamp
version must use remote mount test switch.
(5)
Top Hub required when stem mounting.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Accessories (order separately) VT2-Chain/Set-U=Chain Hanging Set
Includes 6 ft. of chain, 4 large S-Hooks and 4 small S-Hooks
Order One (1) Kit for each 4' Fixture
Two (2) Kits Recommended For 8' Fixtures. VT2-SS-MBK=Stainless Steel Mounting
Bracket
VT3-132 DR-WL 16 lbs. VT3-232 DR-WL 16 lbs. VT3-154T5 16 lbs. VT3-254T5 16 lbs.
Catalog No. Wt.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
10/06/2008 11:40:01 AM
ADF071376
Loading...